MONTHYEARL-99-078, Special Rept:On 990326,seismic Monitoring Instruments Were Declared Inoperable.Caused by Resolution of Potential TS Compliance Issue & Work Scheduling Issue.Instrumentation Was Returned to Svc Following Calibr & Declared Operable1999-05-0303 May 1999 Special Rept:On 990326,seismic Monitoring Instruments Were Declared Inoperable.Caused by Resolution of Potential TS Compliance Issue & Work Scheduling Issue.Instrumentation Was Returned to Svc Following Calibr & Declared Operable L-99-054, Special Rept:On 990320,meteorological Tower Wind Speed Sensors Were Declared Inoperable.Caused by Calibration Completed by Vendor Did Not Adequately Cover Full Operating Range of Sensors.Removed Sensors & Sent Offsite1999-04-0505 April 1999 Special Rept:On 990320,meteorological Tower Wind Speed Sensors Were Declared Inoperable.Caused by Calibration Completed by Vendor Did Not Adequately Cover Full Operating Range of Sensors.Removed Sensors & Sent Offsite L-99-019, Special Rept:On 990120,meteorological Tower Wind Speed Sensors Declared Inoperable.Caused by Processor Card for Sensor Locked Up & Needed to Be Reset.Heater That Fit Around Shaft of Sensor Replaced1999-02-0505 February 1999 Special Rept:On 990120,meteorological Tower Wind Speed Sensors Declared Inoperable.Caused by Processor Card for Sensor Locked Up & Needed to Be Reset.Heater That Fit Around Shaft of Sensor Replaced L-98-188, Special Rept:During 1998,Unit 2 SG Eddy Current exam,26 Tubes Were Improperly Encoded in SG 2RCS-SG21C During Previous Outage.Use of Independent Databases to Track New Indications Being Implemented as Preventive Measure1998-09-21021 September 1998 Special Rept:During 1998,Unit 2 SG Eddy Current exam,26 Tubes Were Improperly Encoded in SG 2RCS-SG21C During Previous Outage.Use of Independent Databases to Track New Indications Being Implemented as Preventive Measure L-98-157, Special Rept:On 980423,inoperability of Seismic Monitoring Instrument Noted.Caused by Obsolescence of Instrument & Inability to Obtain Necessary Spare Parts.Design Change Is Being Pursued to Obtain Replacement Product1998-07-29029 July 1998 Special Rept:On 980423,inoperability of Seismic Monitoring Instrument Noted.Caused by Obsolescence of Instrument & Inability to Obtain Necessary Spare Parts.Design Change Is Being Pursued to Obtain Replacement Product L-98-079, Special Rept:On 980423,noted That 2ERS-RRA-1,triaxial Time History Accelerograph Was Unable to Be Returned to Service within 30 Days.Caused by Obsolescence of Equipment & Failure to Obtain Spare Parts.Will Obtain Replacement Product1998-04-23023 April 1998 Special Rept:On 980423,noted That 2ERS-RRA-1,triaxial Time History Accelerograph Was Unable to Be Returned to Service within 30 Days.Caused by Obsolescence of Equipment & Failure to Obtain Spare Parts.Will Obtain Replacement Product ML20084U7461995-06-0808 June 1995 Special Rept:On 931210,suppl Info Re Unacceptable Recirculation Spray Sys Operation for Supporting Long Term Core Cooling Capability & Maintaining Containment Pressure Subatmospheric in Event of LOCA ML20069M0461994-06-10010 June 1994 Rev 1 to Special Rept,On 940202,notified That Five Moveable Incore Detectors Unacounted For.Subsequent to Original Rept Dtd 940304,defective non-irradiated Detector Located, Reducing Number of Unaccounted for Incore Detectors to Four ML20064G4001994-03-0404 March 1994 Special Rept:On 940202,notification Made Via ENS That Five Moveable Incore Detectors Could Not Be Traced from Receipt to Final Disposition.Unaccounted SNM in Detectors Not Considered to Be Hazard to Health & Safety of Public ML20059M9411993-11-15015 November 1993 Special Rept:On 930922,seismic Monitor 2ERS-RRA-1 Declared Inoperable.Caused by High Radiation Dose Rate in SG Support Cubicle Elevation 718'6.Monitor Repaired & Returned to Operable Status on 931014 ML20059C4181993-10-27027 October 1993 Rev to Special Rept,Documenting Results of ISI of SG Tubes Performed During Fourth Refueling Outage Completed on 931014.Rev Issued to Correct Duplication in Table,W/Regard to Number of Tubes Plugged as Precautionary Measure ML20059B3751993-10-25025 October 1993 Special Rept:On 931014,inservice Insp of Tubes in Steam Generator Completed.Two Tubes Removed from Svc Due to Tube Degradation in Excess of TS Limit of 40 Percent Through Wall ML20058N7951993-10-15015 October 1993 Special Rept:On 930907,seismic Accelerometer Located on Operating Deck of Containment XT-ER-105B Failed Monthly Operating Surveillance Test & Declared Inoperable.Cause of Malfunction Cannot Be Determined.Accelerometer Replaced ML20128G3741993-02-0909 February 1993 Special Rept:On 930111,discovered That 80 of 90 Nozzles in Train B Charcoal Filter Bank Fire Suppression Sys Clogged W/ White Scale Matl.Caused by Use of Undersize Strainer.Nozzles Removed & Cleaned & New Strainers Installed ML20086U5121991-12-23023 December 1991 Special Rept Re Failure to Test ultra-violet Flame Detectors Via Separate Procedures W/Different Frequencies than Smoke Detector 6-month Procedures.Caused by Inadequate Review of NFPA Code Changes.Hads Provide CR Indication of Fire ML20065Q3851990-12-14014 December 1990 Special Rept Re Potentially Overstressed Feedwater Supports Due to Postulated Monoball Binding Discovered During 1989 Feedwater Line Monitoring Program.Administrative Controls Implemented.Possibly Reportable Per Part 21 ML20065G9511990-10-15015 October 1990 Special Rept:On 900830,alert Declaration Received Following Inadvertent Carbon Dioxide Discharge.Normal & Emergency Portable Ventilation Established to Purge Affected Areas. Repairs on Valve Scheduled ML20059C2041990-08-23023 August 1990 Special Rept:On 900531,automatic Overpower Turbine Runback Alarm Occurred.Caused by Failure of Electrolytic Capacitor in Governor Valve Servo Card.Governor Valve Closed & Isolated Unit Control Problem Corrected ML20247J7731989-09-15015 September 1989 Special Rept:On 890815,dampers Failed to Comply W/Ul Requirements of Std 555-1968.Caused by Improper Fabrication. All Applicable Fire Dampers in Affected Areas W/Combustible Loading Exceeding 1 H Per 10CFR50,App R Will Be Replaced ML20247E9731989-05-16016 May 1989 Special Rept Re Pressurizer Surge Line Displacement Phenomenon Noted at Facility.In Late 1986,rotation of Trapeze for Snubbers Located on Pressurizer Surge Line Noted.On 870728,thermal Gradient of 100 F Noted ML20236E4751989-05-16016 May 1989 Special Rept Re Hydrogen Gas Accumulation in Charging (High Head Safety Injection) Pump Suction Piping.Caused by Diverse Set of Hydrogen Accumulation Situations Between Two Units Due to Difference in Piping Design.Design Change Initiated ML20246N7681989-05-0909 May 1989 Special Rept:On 890401,seismic Instrumentation Central Control Cabinet 2ERS-CCC-1 Not Returned to Svc within 30 Days & Trigger Card Output Could Not Be Reset Correctly. Replacement Accelerograph Expected by 890605 ML20147D7231988-02-29029 February 1988 Special Rept:On 880122,electrical motor-driven Fire Pump Declared Out of Svc for Corrective Maint Due to Packing Leak.Repair Activities Will Not Be Completed within 7 Days. Temporary Diesel Fire Pump Added to Supply Suppression Sys ML20195H1951988-01-13013 January 1988 Special Rept:Seven Fire Dampers Failed to Fully Close During Operational Testing & Not Restored within 7 Days.Cause Undertermined.Dampers Adjusted & Returned to Svc After Retesting Except VS-D-260 & 285.Fire Watch Established ML20235V2071987-10-0909 October 1987 Special Rept:On 870928,train a Upper Range Static Reactor Vessel Level Indication Declared Inoperable Based on Input Failures from Transmitter & Hydraulic Isolator.Transmitter Under Investigation ML20237J0141987-08-0303 August 1987 Special Rept:On 870726,main Steam Effluent Monitor Declared out-of-svc.Caused by Sample Line Steam Leakage.Alternate Preplanned Monitoring Methods in Effect Until Channels Placed Back in Svc ML20237J0301987-08-0303 August 1987 Special Rept:On 870728,in Containment high-range Monitor Declared out-of-svc Due to Loss of Detector Signal & Repeated Check Source Failure.Caused by Overheating pico- Ampmeter Board.No Potential for Radiation Levels Noted ML20236M3021987-07-29029 July 1987 Special Rept:On 870723,auxiliary Feed Pump Turbine Exhaust Monitor Declared Out of Svc Due to Receipt of High & hi-hi Alarms W/Normal Background Radioactivity Present.Replacement Detector Will Be Procured from Vendor ML20215F8581987-06-12012 June 1987 Special Rept:On 870508,triaxial Time History Accelerometer in Primary Auxiliary Bldg Removed from Svc for More than 30 Days to Replace Acceloremeter in Containment Bldg,Removed for Recalibr.Vendor Return Shipment Scheduled for 870629 ML20207S8541987-03-16016 March 1987 Ro:On 870305,w/both Units 1 & 2 Fire Suppression Sys High Pressure Pumps Inoperable,Diesel Driven Fire Pump FP-P-2 Repeatedly Attempted to auto-start.Caused by Clogged Lines Between Fire Suppression Sys Header & Hydropneumatic Tank ML20212J6481987-03-0505 March 1987 Ro:On 870305,both Fire Suppression Sys High Pressure Pumps Inoperable.Caused by Diesel Driven Fire Pump FP-P-2 Repeatedly Attempting to Autostart When Pump FP-P-1 Removed from Svc.Pump FP-P-1 Returned to Svc.Rept Will Be Submitted ML20215B0841986-12-0505 December 1986 Special Rept:On 861027,triaxial Time History Accelerometer Declared Out of Svc.Accelerometer Removed & Partially Decontaminated.Components Corroded Due to Inadvertent Refueling Cavity Overflow.Replacement Components Ordered ML20203F9911986-07-17017 July 1986 Special Rept Per Tech Specs 6.9.2, Special Repts & 3.12.1, Land Use Census, Re Comparison of Dose Calculations.Change to Offsite Dose Commitment Manual Unnecessary Based on Listed Reasons ML20207C9761986-07-0909 July 1986 Special Rept:On 860616,fire Dampers VS-D-93,95A & 95B Declared Inoperable After Not Fully Closing During Testing. Caused by Damper Binding.After Mechanical Adjustments, Lubrication & Testing,Dampers Returned to Svc on 860707 ML20203G2431986-04-22022 April 1986 Ro:On 860410,SPING Radiation Monitor RM-VS-109 Taken Out of Svc Due to Complete Unit Failure.Caused by Failure on Memory Board.Unit Software Replaced W/Updated Version.Unit Will Be Returned to Svc on Completion of Maint Surveillance ML20137R3421986-01-21021 January 1986 Special Rept:On 860109,main Steam Monitor RM-MS-100A Declared Out of Svc to Perform Troubleshooting.Caused by Bad Discriminator Board & Failed Detector.Both Components Replaced & Monitor Returned to Svc ML20141H9111985-11-29029 November 1985 Special Rept:On 851031,contaminated Water Emptying from Open End of Uncompleted cross-connecting Pipe Discharged Into Sump in Condensate Polishing Bldg & Sump Discharged to River.Caused by Personnel Error.Barrier Installed ML20137C7601985-11-12012 November 1985 Rev 1 to Special Rept ND1SS1:2506:on 850720,main Steam Monitor RM-MS-100B Declared Out of Svc Due to Receipt of High Alarm W/Normal Background Radioactivity Present.Caused by Loose Triaxial Connector.Replacement Parts Installed ML20132A7571985-07-29029 July 1985 Special Rept:On 850720,maint Steam Monitor RM-MS-100B Declared Out of Svc Due to Receipt of High Alarm W/Normal Background Radioactivity Present.Cause Undetermined. Alternate Monitoring Planned Until Channel Returned to Svc ML20116C7631985-04-0202 April 1985 Special Rept:On 840912 - 850116,fire Protection Audit Revealed Lack of Suitable Fire Barriers in Duct Work Between Control Room HVAC Equipment Room,Cable Tray Mezzanine & Process Instrument/Rod Position Room ML20090D8681984-06-20020 June 1984 Rev 1 to Special Rept:On 840215,Channels 7 & 9 of Special Particulate,Iodine Noble Gas Monitor for Radiation Monitor RM-VS-110 Declared Out of Svc.Cause Undetermined.Bubble Memory Manipulated & Parameter Files re-edited ML20091N8681984-05-25025 May 1984 Ro:On 840429,diesel Engine Driven Fire Pump FP-P-2 Failed to Complete Surveillance Test & Declared Inoperable.Cause Unknown.Fuel Shutoff Valve Assembly,Voltage Regulator, Generator & Indicating Lamp Bulb & Socket Replaced ML20084K4911984-04-13013 April 1984 Rev to 840224 Special Rept:On 840215,Channels 7 & 9 of Particulate Iodine,Noble Gas Monitor Declared out-of-svc Due to Constant Receipt of High Radiation Alarms.Complete Spare Parts Kit for Monitors Will Be Acquired ML20086T1021984-02-29029 February 1984 Ro:On 840215,high Radiation Alarms W/Normal Activity Present Received Constantly for Channels 7 & 9 of Special Particulate Iodine,Noble Gas Monitor.Cause Could Not Be Determined.Vendor Will Assist in Investigation ML20072N3171983-03-0202 March 1983 Ro:On 830225,Discharge 302 (Sewage Treatment Plant Effluent) Discovered Out of Spec in Fecal Coliform.Caused by Abnormally High Amount of Solids Floating on Chlorine Contact Tank.Effluent Will Be hand-chlorinated ML20054E1231982-04-16016 April 1982 RO 82-011/01P & 82-012/01P:on 820416,overstress Conditions Identified at Four Locations in Safety Injection Sys & Three Locations in Main Steam Sys.Required Mods to Bring Supports within Acceptable Limits Will Be Made ML20126H3451981-03-26026 March 1981 RO 81-029/01P:on 810325,reported Discrepancy Between Plant Mod Manual & Tech Specs Found During 810312 Review of Inservice Insp Requirements for Mods Recently Completed on RCS & Safety Injection Sys ML20126F2771981-03-0606 March 1981 RO 81-019/01P:on 810305,RHR Low Flow Alarm Actuated W/Low Running Current on Pump 1 B During Reactor Shutdown at 100 F & Atmospheric Pressure.Cause Not Stated.Sys Vented & Reactor Coolant Piping Refilled to Approx 65% ML20064K3991980-11-21021 November 1980 RO Followup on 800403 Rept:On 800225,two Frequencies on Peak Shock Annunciator Sys Actuated Visual Alarms W/O Occurrence of Seismic Event.Problem Traced to Reed Switches in Containment Transmitter.Sys Checked & Recalibr ML20064K3691980-11-17017 November 1980 RO 80-77/01P:on 801114,evaluation Per IE Bulletin 79-14 Indicated That Support on a Main Steam Header Line Was Less Conservative than Assumed in Tech Specs.Support Mods Were Complete on 801115 1999-05-03
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARL-99-154, Monthly Operating Repts for Sept 199 for Bvps,Units 1 & 2. with1999-09-30030 September 1999 Monthly Operating Repts for Sept 199 for Bvps,Units 1 & 2. with L-99-139, LER 99-S01-00:on 990813,uncompensated Loss of Ability to Detect within Single Intrusion Security Detection Zone Occurred.Caused by Procedure non-compliance.Involved Personnel Received Counseling Re Event.With1999-09-0202 September 1999 LER 99-S01-00:on 990813,uncompensated Loss of Ability to Detect within Single Intrusion Security Detection Zone Occurred.Caused by Procedure non-compliance.Involved Personnel Received Counseling Re Event.With L-99-140, Monthly Operating Repts for Aug 1999 for Bvps,Units 1 & 2. with1999-08-31031 August 1999 Monthly Operating Repts for Aug 1999 for Bvps,Units 1 & 2. with L-99-126, Monthly Operating Repts for Jul 1999 for Beaver Valley Power Station,Units 1 & 2.With1999-07-31031 July 1999 Monthly Operating Repts for Jul 1999 for Beaver Valley Power Station,Units 1 & 2.With L-99-107, Monthly Operating Repts for June 1999 for Bvps,Units 1 & 2. with1999-06-30030 June 1999 Monthly Operating Repts for June 1999 for Bvps,Units 1 & 2. with ML20209D9531999-06-27027 June 1999 Inservice Insp Ninety-Day Rept Bvps,Unit 2 Outage 7,Year 1999 L-99-096, Monthly Operating Repts for May 1999 for BVPS Units 1 & 2. with1999-05-31031 May 1999 Monthly Operating Repts for May 1999 for BVPS Units 1 & 2. with L-99-078, Special Rept:On 990326,seismic Monitoring Instruments Were Declared Inoperable.Caused by Resolution of Potential TS Compliance Issue & Work Scheduling Issue.Instrumentation Was Returned to Svc Following Calibr & Declared Operable1999-05-0303 May 1999 Special Rept:On 990326,seismic Monitoring Instruments Were Declared Inoperable.Caused by Resolution of Potential TS Compliance Issue & Work Scheduling Issue.Instrumentation Was Returned to Svc Following Calibr & Declared Operable L-99-079, Monthly Operating Repts for Apr 1999 for Beaver Valley Power Station,Units 1 & 2.With1999-04-30030 April 1999 Monthly Operating Repts for Apr 1999 for Beaver Valley Power Station,Units 1 & 2.With ML20205L0401999-04-0909 April 1999 SER Accepting Util Relief Requests for Inservice Insp Second 10-year Interval for Beaver Valley Power Station, Unit 2 L-99-054, Special Rept:On 990320,meteorological Tower Wind Speed Sensors Were Declared Inoperable.Caused by Calibration Completed by Vendor Did Not Adequately Cover Full Operating Range of Sensors.Removed Sensors & Sent Offsite1999-04-0505 April 1999 Special Rept:On 990320,meteorological Tower Wind Speed Sensors Were Declared Inoperable.Caused by Calibration Completed by Vendor Did Not Adequately Cover Full Operating Range of Sensors.Removed Sensors & Sent Offsite L-99-058, Monthly Operating Repts for Mar 1999 for Bvps,Units 1 & 2. with1999-03-31031 March 1999 Monthly Operating Repts for Mar 1999 for Bvps,Units 1 & 2. with ML20196K7981999-03-25025 March 1999 Rev 4 to COLR, for Cycle 8 L-99-038, Monthly Operating Repts for Feb 1999 for Bvps,Units 1 & 2. with1999-02-28028 February 1999 Monthly Operating Repts for Feb 1999 for Bvps,Units 1 & 2. with ML20203E1181999-02-10010 February 1999 SER Accepting Proposed Revs to Plant,Units 1 & 2 Quality Assurance Program Description L-99-019, Special Rept:On 990120,meteorological Tower Wind Speed Sensors Declared Inoperable.Caused by Processor Card for Sensor Locked Up & Needed to Be Reset.Heater That Fit Around Shaft of Sensor Replaced1999-02-0505 February 1999 Special Rept:On 990120,meteorological Tower Wind Speed Sensors Declared Inoperable.Caused by Processor Card for Sensor Locked Up & Needed to Be Reset.Heater That Fit Around Shaft of Sensor Replaced ML20196F7011999-01-31031 January 1999 BVPS Unit 2 Heatup & Cooldown Limit Curves During Normal Operation at 15 EFPY Using Code Case N-626 ML20203D4811999-01-31031 January 1999 Monthly Operating Repts for Jan 1999 for Bvps,Units 1 & 2, in Accordance with NRC GL 97-02.With ML20207E6631999-01-28028 January 1999 Rev 0 to EMECH-0713-1, Operational Assessment of SG Tubing at Beaver Valley Unit 1,Cycle 13 ML20210G7041999-01-22022 January 1999 BVPS Unit 1 Facility Changes,Tests & Experiments for 980123-990122 ML20207E5861998-12-31031 December 1998 Annual Rept 1998 for Toledo Edison ML20207E5601998-12-31031 December 1998 Annual Rept 1998 for Pennpower ML20198B9021998-12-31031 December 1998 BVPS Unit 1 Simulator Four Yr Certification Rept for 1995-1998 ML20207E5901998-12-31031 December 1998 Dqe 1998 Annual Rept to Shareholders ML20199C9971998-12-31031 December 1998 Monthly Operating Repts for Dec 1998 for Bvps,Units 1 & 2. with ML20207E5521998-12-31031 December 1998 Annual Rept 1998 for Ohio Edison ML20207E5761998-12-31031 December 1998 Annual Rept 1998 for Illuminating Co ML20204J6751998-12-31031 December 1998 1998 Annual Rept for Dbnps,Unit 1,PNPP,Unit 1 & BVPS Units 1 & 2 ML20199F5341998-12-29029 December 1998 Safety Evaluation Granting Relief Requests 1-TYP-3-B3.140-1, 1-TYP-3-B5.70-1,1-TYP-3-RH-E-1-1,1-TYP-3-B-G-1, 1-TYP-3-APP-I-1,1-TYP-3-UT-1,1-TYP-3-N-509,1-TYP-3-N-521, 1-TYP-3-N-524,1-TYP-3-B3.120-1 & 1-TYP-3-C6.10-1 ML20198K8551998-12-21021 December 1998 SER Granting Relief Request PRR-5 for Third 10-year Inservice Testing for Beaver Valley Power Station,Unit 1 ML20198A1631998-12-0909 December 1998 SER Approving Implementation Program to Resolve USI A-46 at Facility That Has Adequately Addressed Purpose of 10CFR50.54(f) Request L-98-229, Monthly Operating Repts for Nov 1998 for Bvps,Units 1 & 2. with1998-11-30030 November 1998 Monthly Operating Repts for Nov 1998 for Bvps,Units 1 & 2. with ML20195J3131998-11-12012 November 1998 Safety Evaluation Granting First & Second 10-yr Interval Inservice Insp Request for Relief L-98-210, Monthly Operating Repts for Oct 1998 for Bvps,Units 1 & 2. with1998-10-31031 October 1998 Monthly Operating Repts for Oct 1998 for Bvps,Units 1 & 2. with ML20206G0291998-10-31031 October 1998 BVPS Unit 2 Facility Changes,Tests & Experiments for Period 971101-981031 ML20154R9121998-10-20020 October 1998 Safety Evaluation Accepting Proposed Changes to QA Program Description in Chapter 17.2 of BVPS-2 Ufsar.Proposed Changes Would Modify QA Organization to Allow Warehouse QC Inspectors to Report to Manager of Nuclear Procurement Dept ML20154P7491998-10-19019 October 1998 SE Accepting Second ten-year Interval Inservice Insp Request for Relief RR-1-TYP-2-B5.40-1,Rev 0,for Plant, Unit 1 ML20198F7611998-10-0606 October 1998 Duquesne Light Co,Beaver Valley Power Station 1998 Emergency Preparedness Ingestion Zone Exercise, Conducted on 981006 ML20154C6711998-10-0101 October 1998 Safety Evaluation Concluding That Revised Model Identified in Dl Submittal Was Appropriate for Analysis of Installed Conduit Ampacity Limits.Determined That There Are No Outstanding Safety Concerns with Respect to Ampacity ML20154D5001998-09-30030 September 1998 Special Rept on Overview of BVPS-1 & BVPS-2 TS Compliance Issues & Corrective Action Taken L-98-197, Monthly Operating Repts for Sept 1998 for Beaver Valley Power Station,Units 1 & 2.With1998-09-30030 September 1998 Monthly Operating Repts for Sept 1998 for Beaver Valley Power Station,Units 1 & 2.With ML20154E2171998-09-28028 September 1998 Follow-up Part 21 Rept Re Defect with 1200AC & 1200BC Recorders Built Under Westronics 10CFR50 App B Program. Westronics Has Notified Bvps,Ano & RBS & Is Currently Making Arrangements to Implement Design Mods L-98-188, Special Rept:During 1998,Unit 2 SG Eddy Current exam,26 Tubes Were Improperly Encoded in SG 2RCS-SG21C During Previous Outage.Use of Independent Databases to Track New Indications Being Implemented as Preventive Measure1998-09-21021 September 1998 Special Rept:During 1998,Unit 2 SG Eddy Current exam,26 Tubes Were Improperly Encoded in SG 2RCS-SG21C During Previous Outage.Use of Independent Databases to Track New Indications Being Implemented as Preventive Measure L-98-178, Monthly Operating Repts for Aug 1998 for Bvps,Units 1 & 2. with1998-08-31031 August 1998 Monthly Operating Repts for Aug 1998 for Bvps,Units 1 & 2. with ML20155B5871998-08-28028 August 1998 Non-proprietary Rev 1 to 51-5001925-01, Risk Assessment for Installation of Electrosleeves at BVPS & Callaway Plant ML20236X2351998-08-0505 August 1998 Part 21 Rept Re Defect Associated W/Westronics 1200AC & 1200BC Recorders Built Under Westronics 10CFR50,App B Program.Beaver Valley,Arkansas Nuclear One & River Bend Station Notified.Design Mod Is Being Developed L-98-168, Monthly Operating Repts for July 1998 for Bvps,Units 1 & 21998-07-31031 July 1998 Monthly Operating Repts for July 1998 for Bvps,Units 1 & 2 L-98-157, Special Rept:On 980423,inoperability of Seismic Monitoring Instrument Noted.Caused by Obsolescence of Instrument & Inability to Obtain Necessary Spare Parts.Design Change Is Being Pursued to Obtain Replacement Product1998-07-29029 July 1998 Special Rept:On 980423,inoperability of Seismic Monitoring Instrument Noted.Caused by Obsolescence of Instrument & Inability to Obtain Necessary Spare Parts.Design Change Is Being Pursued to Obtain Replacement Product L-98-139, Monthly Operating Repts for June 1998 for Bvps,Units 1 & 21998-06-30030 June 1998 Monthly Operating Repts for June 1998 for Bvps,Units 1 & 2 L-98-119, Monthly Operating Repts for Bvps,Units 1 & 21998-05-31031 May 1998 Monthly Operating Repts for Bvps,Units 1 & 2 1999-09-30
[Table view] |
Text
'
e-Biav Valley Power Sta%on Shippingport. PA 15077 0004
^
!En*ENPl."sio.nt September 21,1998 Fax $$N8SE
%l*,Nr*Svi. ion L-98-188 U. S. Nuclear Regulatory Commission
[ Attention: Document Control Desk Washington, DC 20555-0001
Subject:
Beaver Valley Power Station, Unit No. 2 Docket No. 50-412, License No. NPF-73 Special Report In accordance with Appendix A, Beaver Valley Power Station Technical Specification 4.4.5.5.a, " Steam Generators," the following Special Report is submitted.
This information documents the number of tubes removed from service during the Unit 2, August 1998, steam generator eddy current examination. The final review and acceptance of the eddy current data was on September 2,1998.
One hundred percent (100%) of the inservice tubes in Steam Generators 2RCS-SG21A, -SG21B and -SG21C were examined full length with bobbin coil probes. A 3-Coil Zetec Plus Point probe (consisting of the Plus Point,0.115" and 0.080" coils) was [
used to examine 100% of the hot leg top-of-tubesheet region in each steam generator. A
. single coil Plus Point probe was used for low row U-bend examination. Tubes with [
crack-like indications identified in this area were removed from service. All circumferential indications were ibilized prior to removing the tube from service through plugging.
A Zetec 3-Coil Rotating Pancake Coil probe (consisting of a 0.115" diameter pancake coil, axial and circumferential detection coils) was used on indications that could not be resolved through standard bobbin coil testing. 100% of dents and free-span dings 2 2.00 volts, located between the top of the hot leg tubesheet and the third hot leg suppon plate, were examined with the 3 coil Plus Point probe. In addition,100% of the dents 2 5.00 volts, located at tube suppon plate intersections, were also exarained with the 3 coil Plus Point probe.
Examination of the steam generator preselected to meet the Technical Specification required sample,2RCS-SG21C, resulted in a total of three (3) tubes being removed from service. Attachment I lists the tubes removed from service for each steam generator.
, DEllVERING 9809290232 980921 PDR ADOCK 05000412f 0UAL1IY S PDR !
ENERGY L .. .
Beaver Valley Power Station, Unit No. 2 Special Report Page 2 During the August 1998 examination, it was discovered that several tubes in Generator 2RCS-SG21C were mis-encoded during the Unit 2 Sixth Refueling Outage (September 1996). Attachment 2 describes this discrepancy and the preventive measures which are currently in place and those which will be implemented to guard against further instances of mis-encoding the tubes.
Sincerely, Sushil C. Jain c: Mr. D. S. Brinkman, Sr. Project Manager Mr. D. M. Kern, Sr. Resident Inspector Mr. H. J. Miller, NRC Region I Administrator f
l l . .
t Beaver Valley Power Station, Unit 2 l Docket No. 50-412, License No. NPF-73 Special Report ,
l l
ATTACHMENT 1 2RCS-SG21A 2RCS-SG21B 2RCS-SG21C Tubes previously removed from service prior to August 84 75 88 1998 Number of tubes removed from service August 1998:
Single Circumferential Indication @ Hot Leg Tubesheet 3 1 1 Single Axial Indication @ Hot Leg Tubesheet -
1 -
j PIT @ Hot Leg Tubesheet 1 - -
Single Volumetric Indication @ Cold Leg Tubesheet -
1 Single Volumetric Indication @ 8 th Hot Leg Support -
1 -
l
+ 11.32" l
Free-span Pitting (Betweenth6 &7thHot Leg Support) -
3 -
)
Single Volumetric Indication @ 2nd Hot Leg Support - -
1 Number of tubes removed from service afler August 1998 88 81 91 l
1 i
Beaver Valley Power Station, Unit 2 Docket No. 50-412, License No. NPF-73 Special Report ,
ATTACHMENT 2 1
Mis-encoded tubes During the Unit #2. September 1996 S/G Examination ,
\
During the 1998, Unit 2 steam generator eddy current examination, it was discovered that a total of tv/enty-six !
tubes were improperly encoded in steam generator 2RCS-SG21C during the previous outage (September 1996).
This discrepancy resulted in a total of nine tubes not being examined with bobbin coil. The reports submitted to
- the NRC dated October 9,1996, which document the results of the September 1996 examination, are in error.
The reports state a 100% bobbin coil examination was performed in all steam generators when in fact only 99.7%
of the inservice tubes in 2RCS-SG21C were examined.
There were two scenarios involving these discrepancies:
The first scenario involved twenty-five tubes being improperly encoded. This error occurred directly after a manipulator arm pivot move in which the manipulator must be relocated (tilted) away from the channelhead divider plate. This condition poses the greatest challenge for accurate re-positioning of the manipulator. It was during the re-calibration of the manipulator that an error occurred in locating the proper target tubes that are used for position verification (tubes used were one row ofl). Indications that were recorded in the mis-encoded tubes during the September 1996 examination, could not be verified in the 1998 examination. This led to an extensive search of all tubes affected by the error. One calibration group containing 25 tubes was identified. Each tube that was improperly encoded was " fingerprinted" to verify proper identification. The end result showed eight tubes not being examined with bobbin coil during the 1996 examination.
The second scenario involved the use of dual guide tubes and 1 tube being mis-encoded. Dual guide tubes consist of a " fixed" primary guide tube and a " moving" secondary guide tube. Earlier versions of the software (September 1996) used to control the guide tube movement allowed the recording of data prior to the secondary guide tube being "On Condition" "On Condition" is defined as the manipulator completing a desired movement, at which time the row and column values for a given tube location are passed from the fixture control software to the data acquisition software. In this case, data acquisition was started prior to the secondary guide tube being fully aligned with the center of the tube that was to be examined. Instead, the adjacent tube was inadvertently re-examined a second time. (The row and column number of the correct tube location was passed from the manipulator to the acquisition software as the manipulator completed its move). The end result was one (1) tube not examined with bobbin coil during the September examination.
The following are preventive measures that are currently in place to guard against instances of mis-encoding tubes:
o Data acquisition is required to provide a written message to each calibration group indicating each plug location observed during the examination. Data analysis verifies the message as being valid.
o The BVPS site analysis guidelines require a review of all previous history on indications. If an indication is not observed during the present outage, a detailed historical review is performed. In essence, this is a position verification for all tubes that have previous indications.
7 , , ..g ..
Beaver Valley Power Station, Unit 2 Docket No. 50-412, License No. NPF-73 l
Special Report l
ATTACHMENT 2 (cont.)
e The use ofindependent databases to track new and previous indications.
The following additional measures will be implemented to guard against further instances of mis-encoding the tubes:
- The issue involved with the 25 mis-encoded tubes is directly tied to the specific manipulator used (Zetec SM-22). Operator training will be enhanced to provide additional information in the operation of this manipulator and increased awareness of the problems associated with manipulator relocation. (NOTE: This manipulator was not used during the August 1998 examination at Unit 2. In fact, the SM-22 has not been used at BVPS since the Unit 2 September 1996 outage.)
o The issue of acquiring data before the secondary guide tube has stopped has been addressed in later versions of the dual guide tube software.
o The BVPS site analysis guidelines currently require the manipulator operator to perform a position verification ,
at the beginning and end of each calibration group. The location used for verification can be a tube, a plug or stay rod or any other location on the tubesheet. The next revision of the guidelines will require the location used to verify position to be a tube plug. Since tube plug locations are independently verified as part of the installation process, using known plug locations should provide added assurance the operator is using the proper location as a point of reference.
L