OClober 27,1993 Shippmgport. PA 150774X N ND3MNO:3497 Beaver Valley Power Station, Unit No.2 Docket No. 50-412, License No. NPF-73 Revision To Special Renort (Reference Letter No. ND3MNO:3494, dated 10/25/93)
United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:
l In accordance with Appendix A, Beaver Valley Technical Specifications 4.4.5.5.a, i
" Steam Generators," the following revised Special Report is submitted. This revision is being l
issued to correct a duplication in the table. The number of tubes plugged as a precautionary t
measu. was in error, which resulted in an incorrect total. This report is required to document l
the results of the Inservice Inspection of the steam generator tubes, performed during the Fourth Refueling Outage.
On October 14, 1993, the inservice inspection of the tubing in steam generators 2RCS-SG21A (S/G A), 2RCS-SG21B (S/G B), and 2RCS-SG21C (S/G C) was completed. The number of tubes inspected is documented below.
l I
One hundred percent (100%) of all inservice tubes in the three steam generators were I
inspected during the outage. Two tubes were removed from service due to tube degradation in excess of the Technical Specification limit of 40 percent through wall. Two additional tubes
{
were removed from service due to dentmg.
l t
Six Babcock & Wilcox (B&W) rolled plugs on the cold leg side of S/G 21C were replaced with Babcock & Wilcox Inconel 690 plugs, completing the replacement of all Inconel 600 B&W plugs at Unit 2.
A review of the inspection data, coupled with related industry experience, resulted in the
}
precautionary plugging of thirty-four (34) tubes in 2RCS-SG21A, twenty-three (23) tubes in l
2RCS-SG21B, and twenty-nine (29) tubes in 2RCS-SG21C. The tubes were plugged based on.
the indications received at the following locations: U-Bend, Support Plate, Free Span, and Top of Tubesheet. Eght (8) tubes in 2RCS-SG21B were plugged following stabilization due to loose part indications received during steam generator secondary side foreign object inspections.
9311010148 931027 il PDR-ADOCK 05000412 01
"/
s Poa v
010041 l
i October 27,1993 ND3MNO:3497
.Page 2 The following table documents the number of tubes plugged (>40% through wall) this outage in each steam generator, the number of tubes plugged as a precautionary measure due to the indications received at the locations specified above, the number of tubes previously plugged, and the total number of tubes plugged:
S/G S/G S/G 21A 21B 21C f
Tubes plugged this outage 0
2 0
oor indications >40 percent)
Number of tubes plugged as 34 23 29 precautionary Tubes previously plugged 11 7
15 Total tubes plugged 45 32 44
(% of tubes)
(1.33%)
(0.95 %)
(1.30%)
k L. R. Freeland General Manager Nuclear Operations JGT/ke Attachment i
I a
October 27,1993 ND3MNO:3497 Page 3 cc:
Mr. T. T. Martin, Regional Administrator United States Nuclear Regulatory Commission Region 1 475 AllendaleRoad King ofPmssia, PA 19406 Mr. G. E. Edison, BVPS Licensing Project Manager United States Nuclear Regulatory Commission Washington, DC 20555 Larry Rossbach, Nuclear Regulatory Commission, BVPS Senior Resident Inspector i
J. A. Holtz, Ohio Edison 76 S. Main Street Akron, OH 44308 Larry Beck Centerior Energy 6200 Oak Tree Blvd.
Independence, OH 44101-4661 INPO Records Center 700 Galleria Parkway I
Atlanta, GA 30339-5957 o
Mr. Robert Barkanic j
Department of Environmental Resources P.O. Box 2063 16th Floor, Fulton Building Harrisburg, PA 17120 I
Director, Safety Evaluation & Control Virginia Electric & Power Co.
P.O. Box 26666 i
One James River Plaza Richmond, VA 23261 W. Hartley Virginia Power Company 5000 Dominion Blvd.
2SW Glenn Allen, VA 23060 w-T"
~
October 27,1993 ND3MNO:3497 Page 4 J. M. Riddle Halliburton NUS
- Foster Plaza 7 661 Anderson Drive Pittsburgh, PA 15220 Bill Wegner, Consultant 23 Woodlawn Terrace Fredricksburg, VA 22405 1
}
I I
f