wo PSEG Public Service Electric and Gas Company P.O. Box E Hancocks Bridge, New Jersey 08038 Salem Generating Station August 12, 1982 Mr. R. C. Haynes Regional Administrator USNRC Region 1 631 Park. Avenue King of Prussia, Pennsylvania 19406 Dear Mr. Haynes LICENSE NO. DPR-70 DOCKET NO. 50-272 REPORTABLE OCCURRENCE 81-53/03X-1 SUPPLEMENTAL REPORT Pursuant to the requirements of Salem Generating Station Unit No. 1 Technical Specifications, Section 6.9.1.9.b, we are submitting supplemental Licensee Event Report for Reportable Occurrence 81-53/03X-1.

Sincerely yours,

/ W .

H. J. Midura General Manager -

Salem Operations RH:ksplrf CC: Distribution 8208260148 820812 PDR ADOCK 05000 S ,{

The Energy People

% 218') DN) 1181

I s

R: port Number: 81-53/03X-1 Report Date: 08-12-82 Occurrence Date: 5/20/81 Facility: Salem Generating Station, Unit 1 Public Service Electric & Gas Company Hancocks Bridge, New Jersey 08038 1

l IDENTIFICATION OF OCCURRENCE: '

l 1B Diesel - Water Jacket Leak - Inoperable ]

l CONDITIONS PRIOR TO OCCURRENCE: i Mode 3 - Rx Power 0% - Unit Load MWe.

DESCRIPTION OF OCCURRENCE:

During routine operation, an operator making rounds discovered the 1B Diesel Water Jacket was leaking via a 1/4" pipe nipple.

Action Statement 3.8.1.1 was entered at 0545 hours0.00631 days <br />0.151 hours <br />9.011243e-4 weeks <br />2.073725e-4 months <br /> on May 20, 1981.

This occurrence constituted operation in a degraded mode in accordance with Technical Specification 6.9.1.9.b.

DESIGNATION OF APPARENT CAUSE-OF OCCURRENCE:

Personnel error. This occurrence was caused by apparent use of the nipple for support by an unknown person.

ANALYSIS OF OCCURRENCE:

Technical Specification 3.8.1.la requires that with either an offsite circuit or diesel generator inoperable demonstrate the operability of the remaining A.C. sources by performing Surveillance Requirements 4.8.1.1.la and 4.8.1.1.2.a.2 within one hour and at least once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />; thereafter, restore at least two offsite circuits and three diesel generators to operable status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least hot standby within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in cold shutdown within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

CORRECTIVE ACTION:

The 1/4 inch nipple was replaced in kind, and Diesel Generator 1B was tested satisfactorily. Action Statement 3.8.1.1 was terminated at 1650 hours0.0191 days <br />0.458 hours <br />0.00273 weeks <br />6.27825e-4 months <br /> on May 20, 1981. Discussion of the incident will be incorporated into the station training program as an example of the possible safety significance of damage caused by personnel standing on piping and conduit.

'LER 81-53/03X-1 4 L

FAILURE DATA:

1/4 inch' carbon steel nipple.

.i Prepared By: R. Heller . /

i [/ General ganager -

. Salem Operations'

, SORC Meeting No. 82-75 2