Public Service Electric and Gas Company Thomas M. Crimmins, Jr.
Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-4700 Vice President - Nuclear Engineering JUL s o rnso NLR-N90157 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:
STATION BLACKOUT SCHEDULE COMMITMENT SALEM AND HOPE CREEK GENERATING STATIONS DOCKET NOS. 50-272, 50-311 AND 50~354 As coinmitted to in the Public Service Electric and Gas (PSE&G)
Station Blackout Supplemental Response forwarded to you on April 30, 1990, PSE&G hereby submits the schedule for completion of activities required to resolve the third party audit findings identified in that submittal.
Resolution of the audit findings may require consideration of additional variance from NUMARC 87-00 than originally anticipated and detailed in PSE&G submittals dated April 17, 1989 and April 30, 1990.
The NRC will be provided a detailed description of these variances if they are necessary.
A completion date of February 28, 1991 has been established to resolve the audit findings.
If additional modification is determined to be necessary, a proposed schedule will be forwarded to you at that time.
If you have any questions regarding this submittal, please do not hesitate to call.
Attachment 90080~0~70 900730
~o~ -~6~~~ osooo2-1~-~
p PDC
Document Control Desk NLR-N90157 2
c Mr. J. c. stone Licensing Project Manager - Salem Mr. c. Y. Shiraki Licensing Project Manager -
Hope Creek Mr. T. Johnson Senior Resident Inspector Mr. T. Martin, Administrator Region I Mr. Kent Tosch, Chief New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 JUL 3' f1' 1qgo-
SBO MAJOR AUDIT ITEMS RESOLUTION SCOPE SALEM GENERATING STATION
- 1.
Loss of Ventilation Analyses
- 2.
Decay Heat Removal Capability
- a.
Leakage
- b.
Natural Circulation Affects
- c.
Compressed Air Options 3
- Procedures HOPE CREEK GENERATING STATION
- 1.
Loss of Ventilation Analyses
- 2.
Drywell Suppression Pool Heatup
- a.
Mark I Specific
- b.
Condensate Inventory 3.
Procedures