LR-N990396, Forwards Ninety Day Rept for ISI Activities Conducted at Sgs,Unit 2 During Ninth Extended Outage & Tenth Refueling Outage.List of Encl,Provided

From kanterella
(Redirected from ML18107A518)
Jump to navigation Jump to search
Forwards Ninety Day Rept for ISI Activities Conducted at Sgs,Unit 2 During Ninth Extended Outage & Tenth Refueling Outage.List of Encl,Provided
ML18107A518
Person / Time
Site: Salem 
Issue date: 08/26/1999
From: Salamon G
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18107A519 List:
References
LR-N990396, NUDOCS 9909080211
Download: ML18107A518 (61)


Text


------- ---

OPS~G Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038-0236 Nuclear Business Unit AUG 2 6 1999 LR-N990396 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

INSERVICE INSPECTION ACTIVITIES - 90 DAY REPORT NINTH EXTENDED OUTAGE/TENTH REFUELING OUTAGE SALEM GENERATING STATION UNIT 2 DOCl<ET NO. 50-311 FACILITY OPERA TING LICENSE NO. DPR-75 This letter submits the Ninety (90) Day Report for lnservice Inspection (ISi) activities conducted at the Salem Generating Station Unit 2 during the ninth extended outage and the tenth refueling outage. This report is submitted in accordance with Section 4.0.5 of the Technical Specifications for the Salem Generating Station Unit 2 and Article IWA-6220(c) and IWA-6230 of Section XI of the ASME Boiler and Pressure Vessel

/

Code 1986 Edition.

The enclosures to this letter are as foHows: : Form NIS-1, "Owners Data Report for lnservice Inspection," : Exam results for the ninth extended outage, "ISi. RFO Exam Results (S2RF0#9, Rev. O)" : Exam results for the tenth refueling outage, "ISi RFO Exam Results (S2RF0#10, Rev. 2)" : Form NIS-2, "Owners Report for Repairs and Replacements."

--~ -- -

-- - --9909080211 99oa26 ----- - -----------,

PDR ADOCK 05000311 G

PDR The power is in your hands.

95-2168 REV. 6/94

re....

AUG 26 1999 I

I Document Control Desk LR-N990396 Should you have any questions regarding this request, please contact Mr. C. E.

Manges, Jr. at 856~339-3234.

Enclosures (4)

G. Salamon Manager - Licensing C

Mr. H. Miller, Administrator - Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. P. Milano, Licensing Project Manager-Salem U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Mail Stop 8B 1 Rockville, MD 20852 Mr. S. Morris (X24)

USNRC Senior Resident Inspector-Salem Mr. K. Tosch, Manager IV Bureau of Nuclear Engineering P. 0. Box415 Trenton, NJ 08625 Mr. Milton Washington, Chief Inspector NJ Department of Community Affairs Bureau of Boiler and Pressure Vessel Compliance P. 0. Box 814 Trenton, NJ 08625-0814 j

. 50-311 SALEM 2 PSE&G INSERVICE INSPECTION ACTMTIES -90 DAY REPORT NINTH EXTENDED OUTAGE I TENTH REFUELING OUTAGE REC'D. W/LTR. DTD.. 8/26/99... 9909080211

- NOTICE -

THE ATTACHED FILES ARE OFFICIAL RECORDS OF THE INFORMATION &

RECORDS MANAGEMENT BRANCH.

THEY HAVE BEEN CHARGED TO YOU FOR A LIMITED TIME PERIOD AND MUST BE RETURNED TO THE RECORDS & ARCHIVES SERVICES SECTION, T5 C3. PLEASE DO NOT SEND DOCUMENTS CHARGED OUT THROUGH THE MAIL. REMOVAL OF ANY PAGE(S) FROM DOCUMENT FOR REPRODUCTION MUST BE REFERRED TO FILE PERSONNEL.

- NOTICE -

'1

~~~-

-~-

-~~~~~~~~~~~~~~~

l --

ENCLOSURE 1 FORM NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

. 1.

2.
3.
4.
5.
7.
9.

~o.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to*o5/28/9S.-

lnspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Component or Manufacturer or Installer Manufacturer or State or National Appurtenance Installer Province Board Serial No.

No.

No.

  1. 2 Reactor Combustion Engineering 67210 Head NIA 20765 Vessel 67101 Vessel
  1. 21 Steam Westinghouse Tampa Div. P.O.

1201 NIA 68-43 Generator Box 19218, Tampa, FL 33616

  1. 22 Steam Westinghouse Tampa Div. P.O.

1202 NIA 68-44 Generator Box 19218, Tampa, FL 33616

  1. 23 Steam Westinghouse Tampa Div. P.O.

1004 NIA 68-11 Generator Box 19218, Tampa, FL 33616

  1. 24 Steam Westinghouse Tampa Div. P.O.

1204 NIA 68-52 Generator Box 19218, Tampa, FL 33616 Pressurizer Delta Southern 1211 NIA 68-48 Reactor Coolant Pall Trinity Micro. Corp.

NIA NIA NIA Filter

  1. 21 & #22 Engineers & Fabricators Inc.
  1. 21 (S-15860-A)

NIA NIA Residual Heat

  1. 22 (S-15860-D)

Removal Heat Exchanger Boron Injection Westinghouse Electric Corp.

Ul2-70-07-30717-6 NIA NIA Tank

  1. 23 Head Tank Pullman Kelloge NIA NIA NIA Chemical and United Engineers & Constructors NIA NIA NIA Volume&

(UE&C) 30 South 17th St., Phila.

Control Piping PA 19101 System Page: 1 of 56

. 1.

2.
3.
4.
5.
7.
9.
10.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9g:-

l nspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Component or Manufacturer or Installer Manufacturer or State or National Appurtenance Installer Province Board Serial No.

No.

No.

Containment UE&C NIA NIA NIA Spray Piping

. System Main Steam UE&C NIA NIA NIA Piping System Pressurizer UE&C NIA NIA NIA Relief Piping System Pressurizer UE&C NIA NIA NIA Spray Piping System Reactor Coolant UE&C NIA NIA NIA Piping System Residual Heat UE&c*

NIA NIA NIA Removal Piping System Steam Generator UE&C NIA NIA NIA Feed Water Piping System Safety Injection UE&C-NIA NIA NIA Piping System Page: 2 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

  • 1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

a National Board Number for Unit N/A.

7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11.

Abstract of Examinations An inservice examination (ISi) of selected Class 1, Class 2, and Class 3 components of Public Service Electric and Gas Company's (PSEG) Salem Generating Station, Unit 2, was perfonned by PSEG, Magnaflux Quality Services (MQS), The Virginia Corporation of Richmond (VCR) and Framatome Technologies (FTI) personnel during the Ninth Extended Shutdown Outage (June 8, 1995 -August 29, 1997) and Tenth Refueling Outage (April 3, 1999 - May 28, 1999). These examinations constituted the Ninth Extended Outage (2nd Period, 1st Outage) and Tenth Refueling Outage (2nc:1 Period, 2nd Outage) at Salem 2 during

. the Second 10-year Inspection Interval of operation.

The Extended Shutdown Outage #9 was not a refueling outage, and as such shall be reported under Refueling Outage# 10's NIS-1, Ninety (90) Day Report.

Exams were perfonned in accordance with the 1986 Edition of ASME Section XI and the Salem Unit 2 lnservice Inspection Program Long Tenn Plan.

PSI and ISi was perfonned utilizing visual (VT), magnetic particle (MT), liquid penetrant (PT), manual ultrasonic (UT), and radiography (RT) nondestructive examination techniques.

This report also contains augmented examinations required by the Salem Technical Specifications, Regulatory Guides, Circulars and Bulletins issued by the United States Nuclear Regulatory Commission and Public Service Electric and Gas.

The following abstract infonnation is broken down into two sections. The first section (11A) describes the Extended Outage #9 and the second section (11 B) describes Refueling Outage #10.

Page: 3 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11A.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.0. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/99.

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Extended Outage #9:

11A.1 ISi Section XI Volumetric & Surface Examinations performed by VCR, and MQS The Virginia Corporation of Richmond (VCR), and Magnaflux Quality Services (MQS) under the direction of the PSEG ISi Group, conducted seven (7) manual ultrasonic, six (6) magnetic particle examinations.

Class 1 Vessels Piping Class 2 Piping Pressurizer Reactor Coolant Main Steam There were no unacceptable indications identified.

11A.2 ISi Section XI Visual Examinations on Valves and Bolting PSEG's ISi Group conducted five (5) Class 1 bolting exams and one (1) Class 1 valve internal exams.

The following was identified during the course of these examinations:

1. Valve 21SJ54 (WinlSI Sum# 164075) internal VT-3 examination revealed valve wedge cracks (Ref. AR# 951129066).

ISi Section XI examinations were conducted on the following systems:

Safety Injection Reactor Coolant There were no other indications identified.

Page: 4 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11A.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Extended Outage #9 (Cont'd):

11A.3 ISi Section XI System Leakage Examinations PSEG's ISi Group conducted fifty three (53) System Pressure Tests during a System Functional or lnservice Test, on Nuclear Class 1, 2, and 3, in accordance with ASME Section XI.

A system Leakage exam was performed in accordance with ASME Section XI on all Class 1 Systems. The system leakage test was performed with the Reactor Coolant System in Mode 3 (normal operating temperature and pressure) with the insulation installed. No pressure boundary leakage was detected.

Work requests were initiated to correct minor mechanical leakage that was not corrected during the system walkdowns.

Class 2 and 3 System Pressure Tests were conducted on the following systems:

Auxiliary FeedWater Component Cooling Containment Spray Chemical Volume & Control Demineralized Water Fire Protection Main Steam Reactor Coolant Page: 5 of 56 Station Air Spent Fuel Cooling Safety Injection Sampling Service Water Ventilation Control Waste Liquid

1.
2.
3.
4.
5.
7.
9.
10.

11A.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) NIA.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9""9.""""

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Extended Outage #9 (Cont'd):

11A.4 Augmented System Leakage tests per NUREG 0578 "TMI Lessons Learned" 11A.5 PSEG's ISi Group conducted twenty seven (27) System Leakage Tests in accordance with NUREG 0578 on the following systems:

Safety Injection Chemical and Volume Control Sampling Waste Gas Residual Heat Removal Containment Spray Boron Recovery Waste Liquid There were no unacceptable indications identified.

Augmented Exams per NRC Branch Technical Position MEB 3-1 Twenty one (21) welds were examined, to comply with the augmented requirements of NUREG 0800 Standard Review Plan, Section 3.6.2 Branch Technical Position MEB 3-1.

The examinations were performed by VCR with no unacceptable indications identified.

Page: 6 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11A.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant" Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9-g:-

lnspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Extended Outage #9 (Cont'd):

11A.6 Augmented Bolted Connection Exams per ISi Relief Request RR-B7 PSEG's ISi Group conducted eighty eight (88) Class 1 bolted connection Vf-2's in accordance with the ISi Long Term Plan Program Relief Request RR-B7.

The following was identified during the course of these examinations:

11A.6.

Augmented Bolted Connection Exams per ISi Relief Request RR-B7 (Confd)

ITEM Wini SI COMPONENT AR/PR#

DISCREPANT CONDITION NO.

Sum#

IDENTIFICATION DESCRIPTION

1.

051100 6-PR-1205-1 OFB 960628085 Two rejectable studs were identified during Vf-3.

2.

052300 6-PR-1204-1 OFB 960628083 Four rejectable studs were identified during Vf-3.

3.

053700 6-PR-1203-1 OFB 960628068 Two rejectable studs* were identified during VT-3.

4.

255150 2CV79 BOLTING 960321166 Valve bonnet-to-body was found leaking.

5.

257900 2RH2 BOLTING 960325114 Boron deposits found on the bolted connection.

6.

257950 2RH26 BOLTING 960321159 Boron deposits found on the bolted connection.

7.

258150 23SJ54 BOLTING 960322205 Boron deposits found on the bolted connection.

Page: 7 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.
7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02116/95 to 05/28/9-S.-
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.6.

Augmented Bolted Connection Exams per ISi Relief Request RR-B7 (Cont'd)

ITEM WinlSI COMPONENT AR/PR#

DISCREPANT CONDITION NO.

Sum#

IDENTIFICATION DESCRIPTION

8.

258300 22SJ54 BOLTING 960322203 Boron deposit is found on the Bolted connection.

9.

258450 21SJ54 BOLTING 960322200 Boron deposits found on the bolted connection.

10.

259150 21SJ156 BOLTING 960326120 Boron deposits found on the bolted connection.

11A.7 Preservice Examinations on Various Bolting Material Replacements Several bolting materials were replaced as identified below:

11A.7 Preservice Examinations on Various Bolting Material Replacements Cont'd)

ITEM Wini SI COMPONENT PSEG PSEG PSEG NO.

Sum#

DESCRIPTION DCP CJP W.0.#

NO.

NO.

1.

004800 2-RPVCH-STUDS 1-54 N/A N/A 960605016 (Examined six spare studs for future.

replacements)

2.

022800 24-STG-OMB (New 2EC-3384-4 FTl'S Program 951208186 replacement studs)

Page: 8 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

a National Board Number for Unit N/A.

7.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9g,-
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.7 Preservice Examinations on Various Bolting Material Replacements Cont'd)

ITEM Wini SI COMPONENT PSEG PSEG PSEG NO.

Sum#

DESCRIPTION DCP CJP W.0.#

NO.

NO.

3.

022900 23-STG-OMB (New 2EC-3384-3 FTl'S Program 951208184 replacement studs)

4.

023000 22-STG-OMB (New 2EC-3384-2 FTl'S Program 951208183 replacement studs)

5.

023100 21-STG-OMB (New 2EC-3384-1 FTl'S Program 951208181 replacement studs)

6.

023200 24-STG-IMB (New 2EC-3384-4 FTl'S Program 951208186 replacement studs)

7.

023300 23-STG-IMB (New 2EC-3384-3 FTl'S Program 951208184 replacement studs)

8.

023400 22-STG-IMB (New 2EC-3384-2 FTl'S Program 951208183 replacement studs)

9.

023500 21-STG-IMB (New 2EC-3384-1 FTl'S Program 951208181 replacement studs)

10.

051100 6-PR-1205-10FB N/A S-96-304 930803020 (Replaced all bolting after VT-1 indications were found on 2 studs)

11.

052300 6-PR-1204-10FB N/A S-96-303 930803018 (Replaced all bolting after VT-1 indications were found on 4 studs)

Page: 9 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.0. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.
7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9r
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.7 ITEM NO.

12.

13.

14.
15.
16.
17.

Preservice Examinations on Various Bolting Material Replacements Cont'd)

WinlSI Sum#

053700 256000 257950 258050 258450 259150 COMPONENT PSEG PSEG PSEG DESCRIPTION DCP CJP W.0.#

NO.

NO.

6-PR-1203-1 OFB N/A S-96-302 970301001 (Replaced all bolting after VT-1 indications were found on 2 studs) 2PS25 BOLTING N/A S-97-002 961212037 (Replacement of galled bonnet stud & nut during valve re-assembly) 2RH26 BOLTING NIA S-96-125 960126075 (Replaced all bolting materials) 24SJ55 BOLTING N/A S-96-218 960316014 (Replaced all bolting) 21SJ54 BOLTING N/A S-96-203 940704.079 (Replaced 1 stud) 21SJ156 BOLTING 2E0-2430 S-96-215 960429239 (Valve was replaced)

The applicable (PSI) examinations were performed with no unacceptable indications identified.

Page: 1 O of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.
7.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02116/95 to 05/28/9-S.-
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

1.1A. Abstract of Examinations for Extended Outage #9 (Cont'd):

11A.8 ITEM NO.

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.

14.

15.

11A.8 Preservice Examinations on Various Component Supports and their Associated Integral Attachments due to Repair/ Replacement I Modifications Several component supports and their associated integral attachments were replaced I repaired or modified as identified below:

Preservice Examinations on Various Component Supports and their Associated Integral Attachments due to Repair/ Replacement I Modifications (Cont'd)

Wini SI COMPONENT PSEG PSEG PSEG Sum#

SUPPORT DCP CJP W.0.#

IDENTIFICATION NO.

NO.

160310 2C-23-RHH-2 2EC-3373-1 PS-95-039 960222051 167125 2C-22-SIG-11 2EC-3373-1 PS-95-039 960222051 169950 2C-24-RHG-5 2EC-3373-1 PS-95-039 960222051 178450 2P-21-SIS-21 2EE-0256-1 PS-96-081 960625066 178725 2P-21-SIS-23 N/A S-96-226 950919272 184575 2C-21-SIH-186 2EC-3461-1 PS-96-063 960223211 186975 2C-24-SIH-701 2EC-3461-1 PS-96-063 960223211 187425 2C-24-SIH-700 2EC-3461-1 PS-96-063 960223211 188360 2C-21-SIH-190 2EC-3461-1 PS-96-063 960223211 190420 2C-23-SIH-703 2EC-3461-1 PS-96-063 960223211 193770 2C-22-SIG-733 2EC-3461-1 PS-96-069 960223211 194090 2C-22-SIH-734 2EC-3461-1 PS-96-063 960223211 196870 2C-21-SIH-181 2EC-3461-1 PS-96-063 960223211 198770 2C-23-SIH-886 2EC-3461-1 PS-96-063 960223211 204270 2C-22-SIS-806 2EC-3549-1 PS-96-071 960426256 Page: 11 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.
  • Plant Unit: Unit 2 (Facility Operating License DPR-75)
4.

Owner's Certificate of Authorization (if required) NIA.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.
7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/99.
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.8 Preservice Examinations on Various Component Supports and their Associated Integral Attachments due to Repair/ Replacement I Modifications (Cont'd)

ITEM Wini SI COMPONENT PSEG PSEG PSEG NO.

Sum#

SUPPORT DCP CJP W.0.#

IDENTIFICATION NO.

NO.

16.

204470 2C-22-SIH-807 2EC-3549-1 PS-96-071 960426256

17.

206770 2C-21-SIS-803 2EC-3549-1 PS-96-071 960426256

18.

500845 2-PRG-29 2EC-3466-1 PS-96-066 960213355

19.

500891 2-PRG-30 2EC-3466-1 PS-96-066 960213355

20.

706200 2A-CVCG-401 2EC-3478-1 PS-96-055 960301206

21.

706260 2A-CVCH-403 2EC-3478-1 PS-96-055 960301206

22.

722370 2-AFSA-24 2EC-3373-4 PS-96-036 960219255

23.

722540 SWPS-28 2EC-3288-1 PS-95-076 951201194

24.

722545 SWPS-28 IA 2EC-3288-1 PS-95-076 951201194

25.

722570 SWPH-59 2EC-3288-1 PS-95-076 951201194

26.

722575 SWPH-59 IA 2EC-3288-1 PS-95-076 951201194

27.

722580 SWPH-60 2EC-3288-1 PS-95-076 951201194

28.

722585 SWPH-60 IA 2EC-3288-1 PS-95-076 951201194

29.

722590 SWPG-20 2EC-3288-1 PS-95-076 951201194.

30.

722595 SWPG-20 IA 2EC-3288-1 PS-95-076 951201194

31.

722610 SWPG-50 2EC-3288-2 PS-95-092 960228238 960229198

32.

722620 SWPG-21 2EC-3288-1 PS-95-076 951201194

33.

722630 SWPG-21 IA 2EC-3288-1 PS-95-076 951201194 34.

722650 SWPG-49B 2EC-3288-2 PS-95-092 960228238 960229198.

Page: 12 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.
7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28199."°
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.8 Preservice Examinations on Various Component Supports and their Associated Integral Attachments due to Repair/ Replacement I Modifications (Cont'd)

ITEM Wini SI COMPONENT PSEG PSEG PSEG NO.

Sum#

SUPPORT DCP CJP W.0.#

IDENTIFICATION NO.

NO.

35.

722660 SWPS-17 2EC-3288-1 PS-95-076 951201194

36.

722665 SWPS-17 IA 2EC-3288-1 PS-95-076 951201194

37.

722710 SWPG-39 2EC-3288-2 PS-95-092 960228238 960229198

38.

722730 SWPS-34 2EC-3288-2 PS-95-092 960228238 960229198

39.

722735 SWPS-34 IA 2EC-3288-2 PS-95-092 960228238 960229198

40.

722740 SWPS-33 2EC-3288-2 PS-95-092 960228238 960229198

41.

722745 SWPS-33 IA 2EC-3288-2 PS-95-092 960228238 960229198

42.

722750 SWPG-40 2EC-3288-2 PS-95-092 960228238 960229198

43.

722770 SWPH-62 2EC-3288-2 PS-95-092 960228238 960229198

44.

722775 SWPH-62 IA 2EC-3288-2 PS-95-092 960228238 960229198 45.

722780 SWPH-61 2EC-3288-2 PS-95-092 960228238 960229198 Page: 13 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.
7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/99.
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.8 Preservice Examinations on Various Component Supports and their Associated Integral Attachments due to Repair/ Replacement I Modifications (Cont'd)

ITEM Wini SI COMPONENT PSEG PSEG PSEG NO.

Sum#

SUPPORT DCP CJP W.0.#

IDENTIFICATION NO.

NO.

46.

722785 SWPH-61 IA 2EC-3288-2 PS-95-092 960228238 960229198

47.

722800 SWPS-37 2EC-3288-2 PS-95-092 960228238 960229198

48.

722805 SWPS-37 IA 2EC-3288-2 PS-95-092 960228238 960229198

49.

722830 SWPS-54 2EC-3288-2 PS-95-092 960228238 960229198

50.

722835 SWPS-54 IA 2EC-3288-2 PS-95-092 960228238 960229198

51.

722870 MSWG-41A N/A S-96-340 950821233

52.

722910 MSWG-38 2EC-3288-1 PS-95-076 951201194

53.

722920 MSWH-31 2EC-3288-1 PS-95-076 951201194

54.

722930 MSWH-26 2EC-3288-1 PS-95-076 951201194

55.

723000 MSWH-29 2EC-3288-2 PS-95-092 960228238 960229198

56.

723010 MSWH-28 2EC-3288-2 PS-95-092 960228238 960229198

57.

723120 2P-22SWS-1 2EC-3287-2 PS-95-074 951201179 58.

723930 2P-21SWS-1 2EC-3590-4 PS-97-031 961227217 Page: 14 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

a National Board Number for Unit NIA.

7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9g,-
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.8 Preservice Examinations on Various Component Supports and their Associated Integral Attachments due to Repair/ Replacement I Modifications (Cont'd)

ITEM Wini SI COMPONENT PSEG PSEG PSEG NO.

Sum#

SUPPORT DCP CJP W.0.#

IDENTIFICATION NO.

NO.

59.

723940 2P-21SWS-4 2EC-3287-1 PS-95-075 951130320 S-96-014 960606010

60.

723950 2P-SWA-WS04 2EC-3287-1 PS-95-075 951130320

61.

723955 2P-SWA-WS04 IA 2EC-3287-1 PS-95-075 951130320

62.

723960 2P-SWA-WS02 2EC-3287-1 PS-95-075 951130320

63.

723965 2P-SWA-WS02 IA 2EC-3287-1 PS-95-075 951130320

64.

724190 2P-SWA-WS10 2EC-3287-2 PS-95-074 951201179

65.

724195 2P-SWA-WS10 IA 2EC-3287-2 PS-95-074 951201179

66.

724230 2P-22SWG-8 2EC-3590-9 PS-97-030 961231103

67.

724410 2C-23SWG-3C 2EC-3590-15 PS-97-027 970104100

68.

714450 2C-23SWG-15C 2EC-3590-15 PS-97-027 970104100

69.

724580 2C-24SWG-3 2EC-3590-15 PS-97-027 970104100

70.

724630 2C-23SWG-3D 2EC-3590-15 PS-97-027 970104100

71.

724820 2C-22SWG-16 2EC-3590-15 PS-97-027 970104100

72.

725130 2P-21SWG-6 2EC-3287-1 PS-95-075 951130320

73.

725150 2P-22SWS-30 2EC-3590-9 PS-97-030 961231103

74.

725220 2-SWG-405 2EC-3468-1 PS-96-035 960220226

75.

725340 A2-SWG-42 2EC-3287-2 PS-95-074 951201179

76.

725360 A2-SWG-39 2EC-3287-2 PS-95-074 951201179 77.

726300 A2-SWR-84 NIA S-96-018 960514007

78.

726340 A2-SWH-49 2EC-3590-5 PS-97-032 961227218 Page: 15 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.
7.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.8 Preservice Examinations on Various Component Supports and their Associated Integral Attachments due to Repair/ Replacement I Modifications (Cont'd)

ITEM Wini SI COMPONENT PSEG PSEG PSEG NO.

Sum#

SUPPORT DCP CJP W.0.#

IDENTIFICATION NO.

NO.

79.

726370 A2-SWH-46 2EC-3590-4 PS-97-031 961227217

80.

726380 2A-SWG-47 2EC-3287-1 PS-95-075 951130320

81.

726400 2A-SWR-85 N/A S-95-014 960606010 S-96-055

82.

726410 2A-SWH-50 2EC-3287-1 PS-95-075 951130320 S-96-345 960903138

83.

726420 2P-21SWH-3 2EC-3287-1 PS-95-075 951130320

84.

727120 2-AFA-189 2EC-3191-1 PS-93-090 940119115

85.

727400 2-AFSG-10 1EC-3396-4 PS-95-070 951114131

86.

732250 2-AFG-253 2EC-3191-1 PS-93-090 940119115

87.

732930 2-AFG-294 2EC-3191-1 PS-93-090 940119115

88.

732970 2-AFG-298 N/A S-96-199 950922363

89.

733530 24-AFWA-31 2EC-3373-4 PS-96-036 960219255

90.

800005 2-SWG-417 2EC-3468-1 PS-96-035 960220226

91.

800008 2-MSWG-21 N/A S-96-399 961203250

92.

800100 2P-SWA-WS 102 2EC-3287-2 PS-95-074 951201179

93.

800105 2P-SWA-WS102 IA 2EC-3287-2 PS-95-074 951201179

94.

800130 2-MSWG-2922 2EE-0213-1 PS-96-076 960320187

95.

800150 2P-21SWA-3166 2EC-3590-4 PS-97-031 961227217 96.

800155 2P-22SWA-3166 IA 2EC-3590-4 PS-97-031 961227217

97.

800160 2P-21 SWG-3167 2EC-3590-4 PS-97-031 961227217 Page: 16 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) NIA.

5.

Commercial Service Date 10/13/81.

a National Board Number for Unit NIA.

7.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9R
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.8 Preservice Examinations on Various Component Supports and their Associated Integral Attachments due to Repair/ Replacement I Modifications (Cont'd)

ITEM Wini SI COMPONENT PSEG PSEG PSEG NO.

Sum#

SUPPORT DCP CJP W.0.#

IDENTIFICATION NO.

NO.

98.

800170 2P-21SWG-3168 2EC-3590-4 PS-97-031 961227217

99.

800175 2P-21SWG-3168 IA 2EC-3590-4 PS-97-031 961227217 100.

800180 2P-21 SWG-3169 2EC-3590-4 PS-97-031 961227217 101.

800190 2P-21 SWG-3170 2EC-3590-4 PS-97-031 961227217 102.

800200 2P-21SWG-3171 2EC-3590-4 PS-97--031 961227217 103.

800210 2P-21SWS-3172 2EC-3590-4 PS-97-031 961227217 104.

800220 2P-21SWG-3173 2EC-3590-4 PS-97-031 961227217 105.

800230 2P-21 SWS-3200 2EC-3590-4 PS-97-031 961227217 106.

800240 2P-22SWA-317 4 2EC-3590-5 PS-97-032 961227218 107.

800245 2P-22SWA-3174 IA 2EC-3590-5 PS-97-032 961227218 108.

800250 2P-22SWG-3175 2EC-3590-5 PS-97-032 961227218 109.

800260 2P-22SWG-3176 2EC-3590-5 PS-97-032 961227218 110.

800270 2P-22SWG-3177 2EC-3590-5 PS-97-032 961227218 111.

800280 2P-22SWG-3178 2EC-3590-5 PS-97-032 961227218 112.

800290 2P-22SWG-3179 2EC-3590-5 PS-97-032 961227218 113.

800300 2P-22SWG-3180 2EC-3590-5 PS-97-032 961227218 114.

800310 2P-22SWG-3201 2EC-3590-5 PS-97-032 961227218 115.

800320 2Y-21 SWG-3203 2EC-3590-3 PS-97-042 961227214 116.

800330 2Y-22SWG-3204 2EC-3590-3 PS-97-042 961227214 Page: 17 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park-Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

a National Board Number for Unit N/A.

7.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02116/95 to 05/28/9~
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.8 ITEM NO.

117.

118.

119.

120.

Preservice Examinations on Various Component Supports and their Associated Integral Attachments due to Repair/ Replacement I Modifications (Cont'd)

Wini SI Sum#

800340 800345 800350 800355 COMPONENT PSEG PSEG PSEG SUPPORT DCP CJP W.0.#

IDENTIFICATION NO.

NO.

21 SW-ACCUM-VES-2EC-3590-3 PS-97-042 961227214 SUP

&7 PS-97-060 970605285 PS-97-105 961227221 21 SW-ACCUM-VES-2EC-3590-3 PS-97-042 961227214 SUPIA PS-97-060 970605285 22SW-ACCUM-VES-2EC-3590-3 PS-97-042 961227214 SUP

&7 PS-97-060 970605285 PS-97-105 961227221 22SW-ACCUM-VES-2EC-3590-3 PS-97-042 961227214 SUPIA PS-97-060 970605285 The applicable (PSI) examinations were performed with no unacceptable indications identified.

Page: 18 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS

. As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.
7.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9S.--
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A. Abstract of Examinations for Extended Outage #9 (Cont'd):

11A.9 ITEM NO.

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.

11A.9 Preservice Examinations on Various Piping welds due to Repair/ Replacement I Modifications Several piping welds were repaired I replaced or modified as identified below:

Preservice Examinations on Various Piping welds due to Repair/ Replacement I Modifications (Cont'd)

Wini SI COMPONENT PSEG PSEG PSEG Sum#

DESCRIPTION DCP CJP W.0.#

NO.

NO.

176350 6-SJ-1211-1 R1 N/A S-96-215 930327069 176400 6-SJ-1211-2R1 N/A S-96-215 930327069 184652 2-SJ-1249-11A 2EC-3461-1 PS-96-063 960223211 184653 2-SJ-1249-11 B 2EC-3461-1 PS-96-063 960223211 184654 2-SJ-1249-11C 2EC-3461-1 PS-96-063 960223211 184655 2-SJ-1249-11 D 2EC-3461-1 PS-96-063 960223211 184656 2-SJ-1249-11 E 2EC-3461-1 PS-96-063 960223211 184657 2-SJ-1249-11 F 2EC-3461-1 PS-96-063 960223211 184658 2-SJ-1249-11 G 2EC-3461-1 PS-96-063 960223211 184659 2-SJ-1249-11 H 2EC-3461-1 PS-96-063 960223211 184660 2-SJ-1249-111 2EC-3461-1 PS-96-063 960223211 184661 2-SJ-1249-11J 2EC-3461-1 PS-96-063 960223211 184662 2-SJ-1249-11 K 2EC-3461-1 PS-96-063 960223211 184663 2-SJ-1249-11 L 2EC-3461-1 PS-96-063 960223211 187100 2-SJ-1247-12R1 2EC-3461-1 PS-96-063 960223211 187110 2-SJ-1247-12A 2EC-3461-1 PS-96-063 960223211 Page: 19 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.
7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9g,-
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.9 Preservice Examinations on Various Piping welds due to Repair/ Replacement I Modifications (Cont'd)

ITEM Win IS I COMPONENT PSEG PSEG PSEG NO.

Sum#

DESCRIPTION DCP CJP W.0.#

NO.

NO.

17.

187112 2-SJ-1247-12B 2EC-3461-1 PS-96-063 960223211

18.

187114 2-SJ-1247-12C 2EC-3461-1 PS-96-063 960223211

19.

187116 2-SJ-1247-12D 2EC-3461-1 PS-96-063 960223211

20.

187118 2-SJ-1247-12E 2EC-3461-1 PS-96-063 960223211

21.

187120 2-SJ-1247-12F 2EC-3461-1 PS-96-063 960223211

22.

187150 2-SJ-1247-13R1 2EC-3461-1 PS-96-063 960223211

23.

187200 2-SJ-1247-14R1 2EC-3461-1 PS-96-063 960223211

24.

187210 2-SJ-1247-14A 2EC-3461-1 PS-96-063 960223211

25.

187212 2-SJ-1247-14B 2EC-3461-1 PS-96-063 960223211

26.

187214 2-SJ-1247-14C 2EC-3461-1 PS-96-063 960223211

27.

187216 2-SJ-1247-14D 2EC-3461-1 PS-96-063 960223211

28.

188452 2-SJ-1239-11A 2EC-3461-1 PS-96-063 960223211

29.

188453 2-SJ-1239-11 B 2EC-3461-1 PS-96-063 960223211

30.

188454 2-SJ-1239-11 C 2EC-3461-1 PS-96-063 960223211

31.

188455 2-SJ-1239-11 D 2EC-3461-1 PS-96-063 960223211

32.

188456 2-SJ-1239-11 E 2EC-3461-1 PS-96-063 960223211

33.

188457 2-SJ-1239-11 F 2EC-3461-1 PS-96-063 960223211

34.

188458 2-SJ-1239-11 G 2EC-3461-1 PS-96-063 960223211

35.

188459 2-SJ-1239-11 H 2EC-3461-1 PS-96-063 960223211 36.

188460 2-SJ-1239-111 2EC-3461-1 PS-96-063 960223211

37.

188461 2-SJ-1239-11 J 2EC-3461-1 PS-96-063 960223211 Page: 20 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner:. Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.
7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9R
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.9 Preservice Examinations on Various Piping welds due to Repair/ Replacement I Modifications (Cont'd)

ITEM Wini SI COMPONENT PSEG PSEG PSEG NO.

Sum#

DESCRIPTION DCP CJP W.0.#

NO.

NO.

38.

188462 2-SJ-1239-11 K 2EC-3461-1 PS-96-063 960223211

39.

188463 2-SJ-1239-11 L 2EC-3461-1 PS-96-063 960223211

40.

190310 2-SJ-1237-17A 2EC-3461-1 PS-96-063 960223211

41.

190312 2-SJ-1237-17B 2EC-3461-1 PS-96-063 960223211

42.

190314 2-SJ-1237-17C 2EC-3461-1 PS-96-063 960223211

43.

~90316 2-SJ-1237".'17D 2EC-3461-1 PS-96-063 960223211

44.

190318 2-SJ-1237-17E 2EC-3461-1 PS-96-063 960223211

45.

190320 2-SJ-1237-17F 2EC-3461-1 PS-96-063 960223211

46.

190322 2-SJ-1237-17G 2EC-3461-1 PS-96-063 960223211

47.

190324 2-SJ-1237-17H 2EC-3461-1 PS-96-063 960223211

48.

190326 2-SJ-1237-171 2EC-3461-1 PS-96-063 960223211

49.

190328 2-SJ-1237-17J 2EC-3461-1 PS-96-063 960223211

50.

191452 2-SJ-1229-11A 2EC-3461-1 PS-96-063 960223211

51.

191453 2-SJ-1229-11 B 2EC-3461-1 PS-96-063 960223211

52.

191454 2-SJ-1229-11C 2EC-3461-1 PS-96-063 960223211

53.

191455 2-SJ-1229-11 D 2EC-3461-1 PS-96-063 960223211

54.

191456 2-SJ-1229-11 E 2EC-3461-1 PS-96-063 960223211

55.

191457 2-SJ-1229-11 F 2EC-3461-1 PS-96-063 960223211

56.

191458 2-SJ-1229-11G 2EC-3461-1 PS-96-063 960223211 57.

191459 2-SJ-1229-11 H 2EC-3461-1 PS-96-063 960223211

58.

191460 2-SJ-1229-111 2EC-3461-1 PS-96-063 960223211 Page: 21 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.0. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.
7.

Components inspected : (See pages 1 & 2}

8. Exam Dates 02/16/95 to 05/2819°"9.""""
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.9 Preservice Examinations on Various Piping welds due to Repair/ Replacement I Modifications (Cont'd)

ITEM Win IS I COMPONENT PSEG PSEG PSEG NO.

Sum#

DESCRIPTION DCP CJP W.0.#

NO.

NO.

59.

191461 2-SJ-1229-11 J 2EC-3461-1 PS-96-063 960223211

60.

191462 2-SJ-1229-11 K 2EC-3461-1 PS-96-063 960223211

61.

191463 2-SJ-1229-11L 2EC-3461-1 PS-96-063 960223211

62.

193605 2-SJ-1228-7A 2EC-3461-1 PS-96-063 960223211

63.

193610 2-SJ-1228-7B 2EC-3461-1.PS-96-063 960223211

64.

196952 2-SJ-1219-11A 2EC-3461-1 PS-96-063 960223211

65.

196953 2-SJ-1219-11 B 2EC-3461-1 PS-96-063 960223211

66.

196954 2-SJ-1219-11C 2EC-3461-1 PS-96-063 960223211

67.

196955 2-SJ-1219-11D 2EC-3461-1 PS-96-063 960223211

68.

196956 2-SJ-1219-11 E 2EC-3461-1 PS-96-063 960223211

69.

196957 2-SJ-1219-11 F 2EC-3461-1 PS-96-063 960223211

70.

196958 2-SJ-1219-11G.

2EC-3461-1 PS-96-063 960223211

71.

196959 2-SJ-1219-11 H 2EC-3461-1 PS-96-063 960223211

72.

196960 2-SJ-1219-111 2EC-3461-1 PS-96-063 960223211

73.

196961 2-SJ-1219-11J 2EC-3461-1 PS-96-063 960223211

74.

196962 2-SJ-1219-11 K 2EC-3461-1 PS-96-063 960223211

75.

196963 2-SJ-1219-11L 2EC-3461-1 PS-96-063 960223211

76.

198602 2-SJ-1218-10A 2EC-3461-1 PS-96-063 960223211

77.

198604 2-SJ-1218-10B 2EC-3461-1 PS-96-063 960223211 78.

198606 2-SJ-1218-10C 2EC-3461-1 PS-96-063 960223211

79.

198608 2-SJ-1218-10D 2EC-3461-1 PS-96-063 960223211 Page: 22 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) NIA.

5.

Commercial Service Date 10/13/81.

a National Board Number for Unit N/A.

7.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.9 Preservice Examinations on Various Piping welds due to Repair/ Replacement I Modifications (Cont'd)

ITEM WinlSI COMPONENT PSEG PSEG PSEG NO.

Sum#

DESCRIPTION DCP CJP W.0.#

NO.

NO.

80.

200000 2-SJ-1218-38R1 N/A S-96-215 930327069

81.

200155 1.5-SJ-1242-3A 2EC-3549-1 PS-96-071 960702260

82.

200160 1.5-SJ-1242-38 2EC-3549-1 PS-96-071 960702260

83.

200165 1.5-SJ-1242-3C 2EC-3549-1 PS-96-071 960702260

84.

200170 1.5-SJ-1242-3D 2EC-3549-1 PS-96-071 960702260

85.

200175 1.5-SJ-1242-3E 2EC-3549-1 PS-96-071 960702260

86.

200180 1.5-SJ-1242-3F 2EC-3549-1 PS-96-071 960702260

87.

201950 1.5-SJ-1242-38R1 2ER-0018-1 S-96-150 960311137

88.

202000 1.5-SJ-1242-39R1 2ER-0018-1 S-96-150 960311137

89.

202050 1.5-SJ-1242-40R1 2ER-0018-1 S-96-150 960311137

90.

202405 1.5-SJ-1232-5A 2EC-3549-1 PS-96-071 960702260

91.

202410 1.5-SJ-1232-58 2EC-3549-1 PS-96-071 960702260

92.

202415 1.5-SJ-1232-5C 2EC-3549-1 PS-96-071 960702260

93.

202420 1.5-SJ-1232-50 2EC-3549-1 PS-96-071 960702260

94.

202425 1.5-SJ-1232-5E 2EC-3549-1 PS-96-071 960702260

95.

202430 1.5-SJ-1232-5F 2EC-3549-1 PS-96-071 960702260

96.

203750 1.5-SJ-1232-31R1 2ER-0018-1 S-96-149 960311134

97.

203800 1.5-SJ-1232-32R1 2ER-0018-1 S-96-149 960311134

98.

203850 1.5-SJ-1232-33R1 2ER-0018-1 S-96-149 960311134 99.

203900 1.5-SJ-1232-34R1 2ER-0018-1 S-96-149 960311134 100.

204255 1.5-SJ-1222-5A 2EC-3549-1 PS-96-071 960426256 Page: 23 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) NIA.

5.

Commercial Service Date 10/13/81.

a National Board Number for Unit N/A.

7.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.9 Preservice Examinations on Various Piping welds due to Repair/ Replacement I Modifications (Cont'd)

ITEM Wini SI COMPONENT PSEG PSEG PSEG NO.

Sum#

DESCRIPTION DCP CJP W.0.#

NO.

NO.

101.

204260 1.5-SJ-1222-58 2EC-3549-1 PS-96-071 960426256 102.

204265 1.5-SJ-1222-5C 2EC-3549-1 PS-96-071 960426256 103.

204275 1.5-SJ-1222-5D 2EC-3549-1 PS-96-071 960426256 104.

204280 1.5-SJ-1222-5E 2EC-3549-1 PS-96-071 961013064 105.

204285 1.5-SJ-1222-5F 2EC-3549-1 PS-96-071 961013064 106.

206300 1.5-SJ-1222-45R1 2ER-0018-1 S-96-148 960311131 107.

206350 1.5-SJ-1222-46R1 2ER-0018-1 S-96-148 960311131 108.

206400 1.5-SJ-1222-47R1 2ER-0018-1 S-96-148 960311131 109.

206755 1.5-SJ-1212-5A 2EC-3549-1 PS-96-071 960426256 110.

206760 1.5-SJ-1212-58 2EC-3549-1 PS-96-071 960426256 111.

206765 1.5-SJ-1212-5C 2EC-3549-1 PS-96-071 960426256 112.

206775 1.5-SJ-1212-5D 2EC-3549-1 PS-96-071 960426256 113.

206780 1.5-SJ-1212-5E 2EC-3549-1 PS-96-071 960426256 114.

206785 1.5-SJ-1212-5F 2EC-3549-1 PS-96-071 960426256 115.

208650 1.5-SJ-1212-42R2 2ER-0018-1 S-96-147 940801144 116.

208700 1.5-SJ-1212-43R2 2ER-0018-1 S-96-147 940801144 117.

208750 1.5-SJ-1212-44R2 2ER-0018-1 S-96-147 940801144 118.

503340 8-RH-2216-4R 1 N/A S-96-232 960507154 119.

503350 8-RH-2216-5R1 N/A S-96-232 960507154 120.

706170 3-CV-2258-3R 1 2EC-3478-1 PS-96-055 960301206 121.

706190 3-CV-2258-5R 1 2EC-3478-1 PS-96-055 960301206 Page: 24 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

  • 1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

T National Board Number for Unit NIA.

7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/99.
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11A.9 ITEM NO.

122.

123.

124.

125.

126.

127.

128.

129.

130.

Preservice Examinations on Various Piping welds due to Repair/ Replacement I Modifications (Cont'd)

Wini SI COMPONENT PSEG PSEG PSEG Sum#

DESCRIPTION DCP CJP W.0.#

NO.

NO.

706270 3-CV-2258-1 OR2 2EC-3478-1 PS-96-055 960301206 706272 3-CV-2258-1OA(R1) 2EC-3478-1 PS-96-055 960301206 706274 3-CV-2258-10B 2EC-3478-1 PS-96-055 960301206 706276 3-CV-2258-1 OC 2EC-3478-1 PS-96-055 960301206 707602 3-CV-2259-12A 2EE-0147 PS-96-056 960222178 707610 3-CV-2259-13R1 2EE-0147 PS-96-056 960222178 707620 3-CV-2259-14R1 2EE-0147 PS-96-056 960222178 707622 3-CV-2259-14A 2EE-0147 PS-96-056 960222178 707780 4-CV-2258-1 R1 2EC-3593-1 S-96-349 960921087 The applicable (PSI) examinations were performed with no unacceptable indications identified.

Page: 25 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11A.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

T National Board Number for Unit NIA.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Extended Outage #9 (Cont'd):

11A.10 Erosion I Corrosion UT Thickness Program In response to NRC Bulletin 87-01 and Engineering Directive MEC-94-1071, and keeping with our commitment to NRC GL 89-08, fifty nine (59) components were scheduled for UT thickness examinations.

The following Components were replaced, due to the results of the erosion/corrosion UT examinations performed.

11A.10 Erosion I Corrosion UT Thickness Program (Cont'd)

ITEM NO.

1.
2.
3.

SYSTEM COMPONENT ID COMPONENT MSR MSR MSR DESCRIPTION 2S-MSR-518A-T1 8" X 3" TEE 2S-MSR-518A-T2 8" X 3" TEE 2S-MSR-377-V1 4" PIPE IMMEDIATELY DOWNSTREAM OF VALVE 22RD19 As a result of these repairs I replacements, PSEG Engineering judgement, and procedural requirements for readings less than 70% of nominal wall, an examination expansion of sixty seven (67) components was performed. This increased the total number of examinations to one hundred and twenty six (126) components. The following is a break down of these examinations.

a. Three (3) components were replaced.
b. One hundred and twenty three (123) were acceptable for continued service, based on minimum wall design requirements
c. No components required a weld build-up.

There were no other unacceptable indications identified.

Page: 26 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11A.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

a National Board Number for Unit NIA.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Extended Outage #9 (Cont'd):

11A.11 Functional Testing of Selected Hydraulic and Mechanical Snubbers per Technical Specification 4.7.9 (c) 11A.11.1 HYDRAULIC SNUBBERS (FIRST TEST SAMPLE)

Hydraulic snubbers were tested using the Technical Specification 4.7.9(c), 10%

sample plan by Wyle Laboratories using the API in-place snubber test machine and the Wyle Laboratories model 150 snubber test machine as follows:

Two (2) S/G 1,000 Kip Rexnords One (1) MSIV 200 Kip Paul Monroe

  • One (1) S/G 1,000 Kip Rexnords failed its functional test.

11A.11.2 MECHANICAL SNUBBERS (FIRST TEST SAMPLE)

Mechanical snubbers were tested using the Technical Specification 4.7.9(c),

10% sample plan using the Wyle Laboratories model 150 snubber test machine as follows:

One (1) Lisega small snubber Nine (9) mechanical medium (PSA-1, 3 and 10)

Twenty one (21) mechanical small (PSA-1/4 and 1/2) 100% sample All mechanical snubbers were tested satisfactorily.

11A.11.3 HYDRAULIC AND MECHANICAL EXPANDED SNUBBER TEST SAMPLES Due to Hydraulic snubber test failures the following expanded snubber test samples were tested using the Wyle Laboratories model API snubber test machine.

One (1) expanded sample, totaling two (2) S/G 1,000 Kip Rexnords PSEG Engineering performed a stress evaluation on the failed snubber locations and concluded that the piping and components to which the snubbers were attached were not impaired due to in-operability of the snubbers.

Page: 27 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11A.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza; Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Extended Outage #9 (Cont'd):

11A.11 Functional Testing of Selected Hydraulic and Mechanical Snubbers per Technical Specification 4.7.9 (c) (Cont'd) 11A.12 11A.11.4 OUTAGE DURATION TESTING Due to the length and extent of the outage an additional sample was pulled as follows:

Mechanical Snubbers (Extended Outage):

One (1) Lisega small Snubber Nine (9) Mechanical medium Snubbers (PSA-1, 3, & 10) 100% of mechanical small snubbers were tested during the first sample, therefore three (3) mechanical small Snubbers (PSA-1/4 &

1/2) were tested.

Steam Generator Tube Eddy Current Inspection per Technical Specification 4.4.6.0 Over 143,000 inspections were performed to assess the overall condition of the Unit 2 steam generators. The examinations were performed by Framatome Technologies, Inc. (FTI) in accordance with their safety related QA program and as required by:

Salem Unit 2 Technical Specifications,Section XI, 1986 Edition, of ASME Boiler and Pressure Vessel Code, PSEG site specific data analysis guidelines.

A bobbin coil examination was performed on 100% of the in-service tubes in each steam generator. The bobbin coil exam was first attempted with a 0. 720" diameter probe for all tubes. If the 0. 720" probe was not successful in traversing the full length of the tube, the tube was reexamined using a 0. 700" or 0.680" diameter probe.

Page: 28 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11A.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

T National Board Number for Unit N/A.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/99.

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Extended Outage #9 (Cont'd):

11A.12 Steam Generator Tube Eddy Current Inspection per Technical Specification 4.4.6.0 (Cont'd)

Motorized Rotating Pancake Coils (MRPC) were used to examine all hot leg tubesheet transitions and all hot leg tube support plates. This examination was expanded to include all of the cold leg tubesheet transitions and tube support locations in one steam generator (SIG 22). The MRPC inspections utilized a 3-coil probe that included a plus point coil, a 0.115" mid-range frequency coil and a 0.080" high frequency coil. Special interest MRPC examinations were performed on tube locations with a bobbin percent throughwall indication of 40% or greater or with I-code indications. Single coil plus point probes were used for row 2 LI-bends.

All examination techniques, except the low row L)-bend plus point MRPC examination, were qualified under the EPRI "PWR Steam Generator Examination Guidelines," document NP-6201, Appendix H at the time of the examination. Since the examination, a plus point technique for examination of the U-bend regions was qualified and approved for Appendix H. The approved variables were similar to those used for examination of U-bend regions at Salem Unit 2.

A number of cold leg support plate intersections were identified as having volumetric indications. Both the bobbin coil and MRPC examination reported this damage mechanism. Those tubes remaining in-service are below the required plugging limit as sized by the bobbin coil examination. This is an approved EPRI Appendix H qualified sizing technique for cold leg thinning.

Page: 29 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11A.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) NIA.

Commercial Service Date 10113181.

a National Board Number for Unit NIA.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16195 to 0512819-S.--

lnspection Interval from 05110192 to 01103105 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Extended Outage #9 (Cont'd):

11A.12 Steam Generator Tube Eddy Current Inspection per Technical Specification 4.4.6.0 (Cont'd)

Based on both the bobbin and MRPC exams, 220 tubes were plugged. 41 tubes in 21 SIG 21, 52 tubes in 22 SIG, 22 tubes in 23 SIG and 105 tubes in 24 SIG. The indications were classified into seven categories:

Outer diameter intergranular attack/stress corrosion cracking (ODSCC) at tube support plates, ODSCC at the hot leg top-of-tubesheet sludge pile, Primary side stress corrosion cracking (PWSCC) at the hot leg tubesheet expansion region, Corrosion assisted wastage at cold leg tube support plates, Wear at the anti-vibration bars, Possible loose part damage, Indications at tube support plates other than ODSCC (plugged as a preventative measure).

All tube exceeding the technical specification criteria or having crack like indications were plugged. The categorization of each Steam Generator is listed below and takes into consideration both bobbin coil and MRPC inspection results:

SIG 21 - C3 Category SIG 22 - C3 Category SIG 23 - C2 Category SIG 24 - C3 Category Page: 30 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11B.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/99.

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10:

11 B.1 ISi Section XI Volumetric & Surface Examinations performed by FTI, and MQS Framatome Technologies and Magnaflux Quality Services under the direction of the PSEG ISi Group, conducted fifty one (51) manual ultrasonic, one hundred and one (101) liquid penetrant, six (6) magnetic particle examinations.

Class 1 Vessels Piping Class 2 Vessels Piping Rx Vessel Head Pressurizer Reactor Coolant Safety Injection Residual Heat Removal Chemical and Volume Control Pressurizer Relief & Spray Steam Generator Reactor Coolant Filter Residual Heat removal Heat Exchanger Boron Injection Tank Feed Water Main Steam Containment Spray

1.

. 2.

3.
4.
5.
7.
9.
10.

11B.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.0. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #1 O:

11 B.1 ISi Section XI Volumetric & Surface Examinations performed by FTI, and MQS (Cont'd)

The following was identified during the course of these examinations:

3" branch connection 31-RC-1240-4BC (WinlSI Sum# 071500) was found with a PT indication (Ref. AR# 990420214). After surface buffing to determine indication relevancy, the indication was found to be non recordable.

Valve 24SJ138 to pipe weld 2-SJ-1247-7 (WinlSI Sum# 186850) was found with a PT indication (Ref. AR# 990414184). After surface buffing to determine indication relevancy, the indication was found to be non recordable.

There were no other indications identified.

11 B.2 ISi Section XI Visual examinations on valves and bolting PSEG's ISi Group conducted ten (10) Class 1 bolting and no Class 1 valve internal exams.

The following was identified during the course of these examinations:

Valve 2RH1's bolting (WinlSI Sum# 257850) was VT-1 examined in-place. The bolting was found with boron residue. The bolt nearest the leak was removed and was satisfactorily VT-3 examined. The boron residue was removed and the bolt torque was re-verified as required (Ref. AR# 990414183)

Page: 32 of 56

1.
2.
3.
4.
5.
7.
9.
10.

118.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02116/95 to 05/28/9-e.-

lnspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

11 B.2 ISi Section XI Visual examinations on valves and bolting (Cont'd) 11B.3 ISi Section XI examinations were conducted on the following systems:

Safety Injection Residual Heat Removal Chemical and Volume Control Reactor Coolant There were no other unacceptable indications identified.

ISi Section XI Visual examination of components supports (Code Case N-491)

PSEG conducted one hundred and fifty seven (157) Class 1, 2, & 3 component support and associated integral attachment visual VT-3 examinations.

ISi Section XI examinations were conducted on the following systems:

Feed Water Safety Injection Reactor Coolant Chemical and Volume Control Service Water Residual Heat Removal Component Cooling Auxiliary Feed Water Containment Spray Page: 33 of 56

1.
2.
3.
4.
5.
7.
9.
10.

118.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02116/95 to 05/28/9r Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

11 B.3 ISi Section XI Visual examination of components supports (Code Case N-491) (Cont'd)

The following was identified during the course of these examinations:

1. Component support 2-FWH-23-17 (WinlSI Sum# 330275) was VT-3 examined, and was found with the spring can setting out of tolerance (Ref.

AR# 990414195). The component supports on either side of2-FWH-23-17 and an additional sample was satisfactorily VT-3 examined. Component support 2-FWH-23-17 was satisfactorily re-adjusted by Mechanical Maintenance in accordance with W.0.# 990510253.

There were no other unacceptable conditions identified.

11 B.4 ISi Section XI System Leakage Examinations PSEG's ISi Group conducted four (4) System Pressure Tests during a System Functional or lnservice Test, on Nuclear Class 1, 2, and 3, in accordance with ASME Section XI.

A system Leakage exam was performed in accordance with ASME Section XI on all Class 1 Systems. The system leakage test was performed with the Reactor Coolant System in Mode 3 (normal operating temperature and pressure) with the insulation installed. No pressure boundary leakage was detected.

Work requests were initiated to correct minor mechanical leakage that was not corrected during the system walkdowns.

Page: 34 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11B.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the AS:ME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9-g,-

lnspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #1 O (Cont'd):

11 B.4 ISi Section XI System Leakage Examinations (Cont'd) 11B.5 Class 2 and 3 System Pressure Tests were conducted on the following systems:

- Residual Heat Removal

- Chemical and Volume Control NRC Bulletin 88-08 "Thermal Stresses in Piping Connected to the Reactor Coolant System" Augmented Examinations Framatome Technologies under the direction of the PSEG ISi Group performed augmented ultrasonic and dye penetrant examinations on a total of nine (9) components, broken down as follows:

Two (2) 1.5 inch Safety Injection piping welds Two (2) 2 inch Chemical and Volume Control piping welds Five (5) 3 inch Chemical and Volume Control piping welds There are no unacceptable indications identified.

11 B.6 Augmented System Leakage tests per NUREG 0578 "TMI Lessons Lear~ed" PSEG's ISi Group conducted twenty seven (27) System Leakage Tests in accordance with NUREG 0578 on the following systems:

Safety Injection Chemical and Volume Control Sampling Waste Gas Residual Heat Removal Containment Spray Boron Recovery Waste Liquid There were no unacceptable indications identified.

Page: 35 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11B.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

a National Board Number for Unit NIA.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9--S.-

lnspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

11B.7 Augmented Bolted Connection Exams per ISi Relief Request RR-B7 PSEG's ISi Group conducted eighty seven (87) Class 1 bolted connection VT-2's in accordance with the ISi Long Term Plan Program Relief Request RR-B7.

The following was identified during the course of these examinations:

11 B.7 Augmented Baited Connection Exams per ISi Relief Request RR-B7 (Cont'd)

ITEM Wini SI COMPONENT AR/PR#

DISCREPANT CONDITION NO.

Sum#

IDENTIFICATION DESCRIPTION

1.

.184200 2-SJ-1249-2FB 990407172 Boron deposits found on bolted connection.

2.

255975 2PS1 BOLTING 990415263 Boron deposits found on bolted connection.

3.

258000 24SJ54 BOLTING 990414181 Boron deposits found on bolted connection.

4.

258650 21 SJ49 BOLTING 990417087 Boron deposits found on bolted connection.

5.

259600 23SJ388 BOLTING 990407171 Boron deposits found on bolted connection.

6.

259650 24SJ388 BOLTING 990407157 Boron deposits found on bolted connection.

Page: 36 of 56

1.
2.
3.
4.
5.
7.
9.
10.

118.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.0. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) NIA.

Commercial Service Date 10/13/81.

a National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9-S.-

l nspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

11 B.8 PSEG Supplemental Radiographic and Ultrasonic Examinations on the Steam Generator Feedwater Nozzle to Forging Expanders Framatome Technologies Ultrasonically and MQS Radiographically examined the four Steam Generator Feedwater Nozzle to Forging expanders in accordance with PSEG's supplemental examination requirements.

These examinations found the following:

1. Steam Generator #24's Radiographic examination found linear indications.

Ultrasonic examination investigation revealed a recordable indication.

In accordance with CJP# S-99-065 and W.0.# 980611219 the forging expander was replaced in kind.

2. Steam Generator #23's Radiographic examination found linear indications.

Ultrasonic examination investigation revealed a recordable indication.

In accordance with CJP# S-99-085 and W.0.# 980611217 the forging expander was replaced in kind.

There were no other unacceptable indications identified.

Page: 37 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11B.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13181.

6. National Board Number for Unit NIA.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16195 to 05128199.

Inspection Interval from 05110192 to 01103105 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

11 B.9 Preservice Examinations on Various Bolting Material Replacements Several bolted connections were replaced as identified below:

11 B.9 Preservice Examinations on Various Bolting Material Replacements (Cont'd)

ITEM Wini SI COMPONENT PSEG PSEG PSEG NO.

Sum#

DESCRIPTION DCP CJP W.0.#

NO.

NO.

1.

022900 23-STG-OMB (Replaced (4)

NIA FTI Process P.O.#

damaged studs on SIG # 23 Traveler 1010897 Out-Board Manway)

SLG-TRAV-2

2.

023000 22-STG-OMB (Replaced (3)

NIA FTI Process P.O.#

damaged studs on SIG #22 Traveler 1010897 Out-Board Manway)

SLG-TRAV-2

3.

023300 23-STG-IMB (Replaced (4)

NIA FTI Process P.O.#

damaged studs on SIG #23 Traveler 1010897 In-Board Manway)

SLG-TRAV-2

4.

051100 6-PR-1205-1 OFB (2PR5 2EC-3650-1 PS-98-005 980407197 flange bolting replacement, due to a new block body valve)

5.

052300 6-PR-1204-1 OFB (2PR4 2EC-3650-1 PS-98-005 980407197 flange bolting replacement, due to a new block body valve)

6.

053700 6-PR-1203-1 OFB (2PR3 2EC-3650-1 PS-98-005 980407197 flange bolting replacement, due to a new block body valve)

Page: 38 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.
7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02116/95 to 05/28/99.
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

118.9 ITEM NO.

7.
8.
9.
10.
11.

Preservice Examinations on Various Bolting Material Replacements (Cont'd)

Win IS I Sum#

255350 255550 255600 255650 256000 COMPONENT P5EG PSEG PSEG DESCRIPTION DCP CJP W.0.#

NO.

NO.

Valve 2CV27 4 bolting N/A 5-99-121 990423159 replacement Valve 2PR5 bonnet-to-body 2EC-3650-1 P5-98-005 980407197 bolting replacement, due to a new block body valve.

Valve 2PR4 bonnet-to-body 2EC-3650-1 PS-98-005 980407197 bolting replacement, due to a new block body valve.

Valve 2PR3 bonnet-to-body 2EC-3650-1 PS-98-005 980407197 bolting replacement, due to a new block body valve.

Valve 2PS25 bolting N/A 5-99-106 990517044 replacement The applicable (PSI) examinations were performed with no unacceptable indications identified.

Page: 39 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.
7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9S.-
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11 B. Abstract of Examinations for Refueling Outage #1 O (Cont'd):

118.10 Preservice Examinations on Various Component Supports and their Associated Integral Attachments due to Repair/ Replacement I Modifications Several component supports and their associated integral attachments were replaced I replaced or modified as identified below:

11B.10 Preservice Examinations on Various Component Supports and their Associated Integral Attachments due to Repair/ Replacement I Modifications (Cont'd)

ITEM WinlSI COMPONENT PSEG PSEG PSEG NO.

Sum#

SUPPORT DCP CJP W.0.#

IDENTIFICATION NO.

NO.

1.

050950 2C-PRA-150A 2EC-3650-1 PS-98-006 980407197

2.

052150 2C-PRA-146A 2EC-3650-1 PS-98-006 980407197

3.

053450 2C-PRA-154A 2EC-3650-1 PS-98-006 980407197

4.

061500 2C-PRG-180 2EC-3646-1 PS-98-020 980831165

5.

330315 2-FWH-23-18 2EC-3646-5 PS-98-022 980831219

6.

330275 2-FWH-23-17 NIA NIA 990510253

7.

500412 2-PRG-52 2EC-3650-1 PS-98-006 980407197

8.

500612 2-PRG-40 2EC-3650-1 PS-98-006 980407197

9.

700440 2-CSG-110 2EC-3646-2 PS-98-025 980831211

10.

700460 2-CSG-108 2EC-3646-2 PS-98-025 980831211

11.

705890 2-CSG-109 2EC-3646-2 PS-98-025 980831211

12.

705910 2-CSG-107 2EC-3646-2 PS-98-025 980831211 13.

726410 2A-SWH-50 NIA S-99-105 990508118

14.

733920 21-AFWS-50 2EC-3646-5 PS-98-022 980831219 Page: 40 of 56

1.
2.
3.
4.
5.
7.
9.
10.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9--S.-

l nspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

11B.10 Preservice Examinations on Various Component Supports and their Associated ITEM NO.

15.
16.

Integral Attachments due to Repair/ Replacement I Modifications (Cont'd)

WinlSI Sum#

800340 800350 COMPONENT PSEG PSEG PSEG SUPPORT DCP CJP W.0.#

IDENTIFICATION NO.

NO.

21SW-ACCUM-2EC-3590-7 PS-97-105 961227221 VES-SUP 22SW-ACCUM-2EC-3590-7 PS-97-105 961227221 VES-SUP The applicable (PSI) examinations were performed with no unacceptable indications identified.

11 B.11 Preservice Examinations on Various Piping welds due to Repair/ Replacement I Modifications Several piping welds were repaired I replaced or modified as identified below:

11 B.11 Preservice Examinations on Various Piping welds due to Repair/ Replacement I Modifications (Cont'd)

ITEM WinlSI COMPONENT PSEG PSEG PSEG NO.

Sum#

DESCRIPTION DCP CJP W.0.#

NO.

NO.

1.

706270 Replaced spool piece at N/A S-98-051 980416312 706272 valve 2CV141

2.

330600 Replaced the #23 N/A S-99-085 980611217 330610 FeedWater Expander

3.

330260 Replaced the #24 N/A S-99-065 980611219 330250 FeedWater Expander Page: 41 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) N/A.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.
7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11 B.11 Preservice Examinations on Various Piping welds due to Repair/ Replacement I Modifications (Cont'd)

ITEM Wini SI COMPONENT PSEG PSEG PSEG NO.

Sum#

DESCRIPTION DCP CJP W.0.#

NO.

NO.

4.

710810 Replaced valve 2CV89 N/A S-99-061 990311201 710820 710830 710840 710850 710860

5.

711530 Replaced valve 2CV94 N/A S-99-062 990311237 711540 711550 711560 711570

6.

711080 Replaced valve 2CV83 N/A S-99-063 990224154 711090 711100 711110 711120 711130 Page: 42 of 56

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101

2.

Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038

3.

Plant Unit: Unit 2 (Facility Operating License DPR-75)

4.

Owner's Certificate of Authorization (if required) NIA.

5.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.
7.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/99.
9.

Inspection Interval from 05/10/92 to 01/03/05

10.

Applicable Edition of ASME Section XI 1986.

11 B.11 ITEM NO.

7.
8.

Preservice Examinations on Various Piping welds due to Repair/ Replacement I Modifications (Cont'd)

WinlSI Sum#

711400 711410 711420 711430 711440 208600 208650 208700 208750 COMPONENT PSEG PSEG PSEG DESCRIPTION DCP CJP W.0.#

NO.

NO.

Replaced valve 2CV88 NIA S-99-064 990224168 Replaced valve 21SJ17 2ER-0039 S-99-104 990501127 The applicable (PSI) examinations were performed with no unacceptable indications identified.

11B.12 Preservice Examinations per, CJP# S-99-103, Work Order# 990502141 Weld repairs to the 100' personnel airlock door seal knife edges.

The (PSI) examinations were performed with no unacceptable indications identified.

Page: 43 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11B.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

a National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #1 O (Cont'd):

11 B.13 Erosion I Corrosion UT Thickness Program In response to NRC Bulletin 87-01 and Engineering Directive MEC-94-1071, one hundred and seventy four (174) components were scheduled for UT thickness examinations.

The following Components were replaced, due to the results of the erosion/corrosion UT examinations performed.

11 B.13 Erosion I Corrosion UT Thickness Program (Cont'd)

ITEM SYSTEM COMPONENT ID COMPONENT NO.

1.
2.

DESCRIPTION Heater Vent 2S-HV-304-01 (H 34) 3" Orifice Aux.Feed 2S-AF-2069-01 (I 15) 3" Orifice As a result of these repairs I replacements, PSEG Engineering judgement, and procedural requirements for readings less than 70% of nominal wall, an examination expansion of eight (8) components was performed. This increased the total number of examinations to one hundred and eighty two (182) components. The following is a break down of these examinations.

a.

Two (2) components were replaced.

b.

One hundred and eighty (180) were acceptable for continued service, based on minimum wall design requirements

c.

No components required a weld build-up.

There were no other unacceptable indications identified.

Page: 44 of 56

1.
2.
3.
4.
5.
7.
9.
10.

118.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

T National Board Number for Unit N/A.

Components inspected: (See pages 1 &-2)

8. Exam Dates 02/16/95 to 05/28/9-S:-

lnspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

11 B.14 Functional Testing of Selected Hydraulic and Mechanical Snubbers per Technical Specification 4.7.9 (c) 11B.14.1 HYDRAULIC SNUBBERS (FIRST TEST SAMPLE)

Hydraulic snubbers were tested using the Technical Specification 4.7.9(c), 10%

sample plan by Wyle Laboratories using the API in-place snubber test machine and the Wyle Laboratories model 150 snubber test machine as follows:

Two (2) S/G 1,000 Kip Rexnords One (1) MSIV 200 Kip Paul Monroe Two (2) S/G 1,000 Kip Rexnords failed their functional test.

118.14.2 MECHANICAL SNUBBERS (FIRST TEST SAMPLE)

Mechanical snubbers were tested using the Technical Specification 4.7.9(c),

10% sample plan using the Wyle Laboratories model 150 snubber test machine as follows:

One (1) Lisega small snubber Twelve (12) mechanical medium (PSA-1, 3 and 10)

Four (4) mechanical small (PSA-1/4 and 1/2)

All mechanical snubbers were tested satisfactorily.

Page: 45 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11B.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

a National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

11 B.14 Functional Testing of Selected Hydraulic and Mechanical Snubbers per Technical Specification 4.7.9 (c) (Cont'd) 11B.14.3 HYDRAULIC AND MECHANICAL EXPANDED SNUBBER TEST SAMPLES Due to Hydraulic snubber test failures the following expanded snubber test samples were tested using the Wyle Laboratories model API snubber test machine.

Two expanded samples totaling six (6) S/G 1,000 Kip Rexnords PSEG Engineering performed a stress evaluation on all failed snubber locations and concluded that the piping and components to which the snubbers were attached were not impaired due to in-operability of the snubbers.

11B.14.4 DCP 2EC-3646 Six (6) PSA mechanical snubbers were replaced with Lisega type snubbers on the FeedWater system. Three (3) of these snubbers required re-testing, prior to installation, due to the last test being more than one year old.

Page: 46 of 56

1.
2.
3.
4.
5.
7.
9.
10.

118.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) NIA.

Commercial Service Date 10/13/81.

a National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9-S.-

l nspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #1 O (Cont'd):

118.15 Steam Generator Tube Eddy Current Inspection per Technical Specification 4.4.6.0 During the Salem Unit 2 10 111 Refueling Outage in April of 1999 Framatome Technologies Incorporated (FTI) conducted Eddy Current examinations on 21 through 24 steam generators. The inspections were performed after chemical cleaning. 22 and 23 were the first two steam generators to be inspected followed by 21 and 24. In general the bobbin coil inspections were performed from the cold leg and rotating coil (top of tubesheet and dented tube support plate intersections) inspections performed from the hot leg. The exception to this was SG 21 where the bobbin coil inspectio" was performed from the hot leg due to ongoing plug repair efforts in 23 SG HL.

The scope of the inspection was delineated in the 2R 10 SIG Tubing Degradation Assessment. This document identified the active and potential degradation mechanisms affecting the tubing in the Salem Unit 2 Steam Generators, identified the inspection scope and techniques to be used, and provided structural limits for each damage mechanism for assessing tube integrity requirements. The: base eddy current examination scope met Salem Unit 2 Technical Specification requirements. A summary of the base scope follows:

Full-length bobbin coil inspection of 100% of the in-service tubes in each steam generator.

Rotating Coil (+ Point) exam of a 20% sample of the row 2 short radius U-bends (07C-07H) in each steam generator.

Rotating Coil(+ Point) exam of 100% of the hot leg WEXTEX tubesheet transition regions in each steam generator.

Rotating Coil(+ Point) exam of 100% of the >2 volt dented tube support plate intersections, based on 2R9 bobbin coil data, in the defined "critical area" for each steam generator.

Page: 4 7 of 56

1.
2.
3.
4.
5.
7.
9.
10.

118.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) NIA Commercial Service Date 10/13/81.

a National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9R Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

11 B.15 Steam Generator Tube Eddy Current Inspection per Technical Specification 4.4.6.0 (Cont'd)

Rotating Coil (+ Point) exam of 100% of the >2 volt hot leg free span dings based on 2R9 bobbin coil data.

Rotating Coil (+ Point) exam of 20% of the >5 volt dented tube support plate intersections in 24 steam generator at 06H and 07H. The inspection plan was based on 2R9 bobbin coil data.

Rotating Coil(+ Point) examination of the 2R9 Shallow Outside Diameter (SOD) locations in each steam generator.

Rotating Coil (+ Point) examination of two FTI HL rolled plugs.

Rotating Coil(+ Point) examination of previous Suspect Ligament Indications identified from the 2R9 bobbin coil data.

Rotating Coil (+ Point) examination of 100% of the freespan HL >2 volt dings identified from the 2R9 bobbin coil data.

Special Interest Rotating Coil(+ Point) examinations as delineated in the 2R10 Steam Generator Tubing Degradation Assessment or as required.

To ensure the resolution process was properly performed and that field calls were properly reported PSE&G utilized an independent QDA Level Ill per the requirements of EPRI PWR Steam Generator Examination Guidelines, Rev. 5.

An experienced Level Ill QDA from Anatec Intl. performed this task during 2R10.

11B.15.1 Bobbin Coil The majority of the bobbin coil inspections were performed with a 0.720" diameter MULC probe. This resulted in a nominal fill factor of 86% for the examination of 0.875 OD X 0.050" nominal wall thickness tubing. A 0.700" SFRM diameter probe was used for the low row inspections as required. A 0.680" diameter probe was used to examine the low row LI-bend regions.

Page: 48 of 56

1.
2.
3.
4.
5.
7.
9.
10.

118.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

Ef"" National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #.10 (Cont'd):

11 B.15 Steam Generator Tube Eddy Current Inspection per Technical Specification 4.4.6.0 (Cont'd) 118.15.2 Rotating Coil (+Point)

A 0. 720" diameter 3-Coil +Point probe was utilized for the HL TTS, HL Dented TSP, HL Ding, and Special Interest RC inspections. This probe contained a 0.115" diameter mid range pancake coil, mid range +Point coil and a 0.080" high frequency pancake coil. A 0.680" diameter single coil magnetically biased

+Point probe was used for the low row u-bend inspections One 0.600" diameter single coil mag. biased +Point probe was used to examine two hot leg Framatome lnconel 690 rolled plugs.

118.15.3 Results The following table summarizes the number of tubes plugged by generator for the active degradation mechanisms found during 2R10.

Modes of Degradation SIG SIG SIG SIG TOTAL 21 22 23 24 PWSCC @ HL TTS (Circ) 0 1

2 1

4 PWSCC @ HL TTS (Axial) 6 11 2

20 39 AVBWEAR 1

0 1

0 2

PWSCC @ HL TSP (Axial) 1 0

0 0

1 PWSCC LOW ROW U-BENDS (Circ) 0 0

4 0

4 HL FREESPAN ODSCC 1

0 0

0 1

TOTAL INDICATIONS 51 TOTAL TUBES PLUGGED 9

10 8

20 47 Page: 49 of 56

1.
2.
3.
4.
5.
7.
9.
10.

11B.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9-S.-

lnspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #1 O (Cont'd):

11 B.15 Steam Generator Tube Eddy Current Inspection per Technical Specification 4.4.6.0 (Cont'd) 11B.15.4 PWSCC in Hot Leg Tubesheet and Tube Support Regions Axial and Circumferential PWSCC was identified in the hot leg tubesheet during 2R 10. All of the tubes with indications were subject to an historical review for detection, sizing, and growth rates for condition monitoring. No tube required stabilization during 2R10.

Steam generator 21, tube R15 C13 had the only axial PWSCC indication at a tube support elevation. This indication was located at 02H in a 2.41-volt dent.

The bobbin coil examination did not identify this tube support as distorted.

11B.15.5 AVBWear Wear was identified in the U-bend region of all steam generators. This mechanism has been attributed to vibration of the tube against the anti-vibration bars.

Recent eddy current examinations at other sites with Westinghouse Series 51 steam generators brought to light the need for an additional AVB standard with deeper flaws than the traditional 20% and 40% provided in Salem's inline guidetube standards. The deeper insitu flaws are of a voltage that exceeds the upper limit of the calibration curve, thereby raising doubt about the accuracy of indications that are close to the repairable limit of 40%. This standard was manufactured with AVB defects ranging from 30% to 80% through wall. The indications that exceeded the curve in S/G's 22 and 23 were run again with this standard, and a five-point curve was established using the-as-built dimensions. Based on this second run with the deeper standard flaws, the through wall depths of the original run were substantiated, and no addition tubes were plugged.

Page: 50 of 56

1.
2.
3.
4.
5.
7.
9.
10.

118.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/99.

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

118.15 Steam Generator Tube Eddy Current Inspection per Technical Specification 4.4.6.0 (Cont'd) 118.15.6 Low Row U-bend Indications During the 20% +Point examination of the row 2 LI-bends in steam generator 23, an inside diameter single circumferential indication was identified in the hot leg tangent of tube R2 C9. This forced an expansion to 100% of the row 2 U-bends, and a 20% sample of the row 3 u-bends in S/G 23. During the expansion three more row 2 tubes were identified as having similar SCI indications.

A review was performed on the 2R9-+point U-bend data for these tubes.

These indications were present in the 2R9 data, and do not exhibit any noticeable change in signal phase or amplitude from last outage.

118.15.7 Manufacturer's Burnish Marks MBM's were identified with the bobbin coil examination. All freespan indications indicative of an MBM type signal were compared to the 1983 data for historical comparison and to identify significant change in the signals between the two examinations. Any change based on the parameters of the freespan flow chart were identified as an "I" code and further examined with a

+Point probe. Indications not exhibiting change based on the parameters of the flow chart were left in the database with the code "MBH". None of the "MBI" indications were confirmed as crack-like when examined with the +Point probe.

Page: 51 of 56

1.
2.
3.
4.
5.
7.
9.
10.

118.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9-g,-

lnspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

118.15 Steam Generator Tube Eddy Current Inspection per Technical Specification 4.4.6.0 (Cont'd) 118.15.8 Freespan Differential Signals As compared to the M8M signal, freespan differential signals exhibit sharper signal characteristics, which could be indicative of damage mechanisms such as IGA/SCC or pitting. These signals were also compared to the 1983-outage data, as well as the 1996 data, to detect change in phase and voltage. If no change was noted the indication was left in the database as "FSH". Any "FSI" indication was put on the special interest program for +Point examination. All of these indications were NDD'd by +Point with the exception of one tube.

R18C9 in S/G 21 had eleven (11) bobbin indications that were not evident in the 1996 data. The +Point probe identified 18 axial indications along the same axial plane between the hot leg tubesheet and the first support. The mid frequency identifies what appears to be two axial scratches that run between this span, and these indications occur along the length of one of these scratches.

All of the tubes from the same heat lot as tube R 18 C9 were re-evaluated by the lead analyst in steam generator 21 from TSH to 01 H on the bobbin coil data looking for similar indications, and none were noted.

Page: 52 of 56

. 1.

2.
3.
4.
5.
7.
9.
10.

11B.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02116/95 to 05/28/9r Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

11 B.15 Steam Generator Tube Eddy Current Inspection per Technical Specification 4.4.6.0 (Cont'd) 11B.15.9 Suspect Ligament Cracking All bobbin data was analyzed for possible support indications with CDS. The indications identified during this analysis were RPC (+Point) examined to determine if a change had occurred on the previously identified tube support elevations, and as a baseline on the new indications identified during 2R10. No suspect ligament cracks (SLC's) were identified as having a >145 degree gap that would exceed to threshold for repair of these types of indications. New ligament indications were identified by the bobbin method during this examination, and this is attributable to the chemical cleaning of the steam generators. Comparison of the +point data between 2R10 and 2R9 confirms this, as these indications were evident during that examination as well.

In 1998, a study was performed on the 2R9 data to identify possible breached supports. One of the action items from this review was to run the bobbin data at 10 kHz for comparison to the historical low frequency, which was changed in the 2R9 outage to 20kHz. Upon direct comparison of historical indications to the 10 kHz data this outage, it was determined that the change in frequency from 10 kHz to 20 kHz had no influence on the signal formations from outage to outage.

From the 1998 review, one tube in S/G 23, tube R22 C75, was identified as having a missing section of tube support plate that measured 38° by eddy current. This indication was visually verified in that the tube support plate is mis-drilled, and the tube is physically breached into the flow hole.

Page: 53 of 56

. 1.

2.
3.
4.
5.
7.
9.
10.

11B.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) NIA.

Commercial Service Date 10113181.

6. National Board Number for Unit NIA.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16195 to 05128199.

Inspection Interval from 05110192 to 01103105 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

11 B.15 Steam Generator Tube Eddy Current Inspection per Technical Specification 4.4.6.0 (Cont'd) 118.15.10 Suspect Ligament Cracking (Cont'd)

Also from the 1998 review, one tube in SIG 24, tube R46 C41, was identified as having multiple indications indicating a possible breach. This tube was visually verified to be a single crack in the support plate immediately adjacent to the patch plate weld.

118.15.11 Loose Parts The eddy current data was manually analyzed for loose parts two tubes around the entire periphery and down the divider plate. There was one possible loose part confirmed with the +point coil during this examination in SIG 23, tube R28 C76.

After chemical cleaning a visual examination was performed in the areas of the steam: generators where loose parts were visually confirmed during 2R9. Two of the objects identified have been retrieved, and the balance was relocated during the chemical cleaning and sludge lancing processes.

There.were two tubes identified during the 2R7 that exhibited signs of loose part wear above the hot leg tubesheet in SIG 24. The part was removed and these tubes subsequently left in service. During 2R10, these indications were sized with the techniques available for the +Point coil using the AVB wear standard, which is indicative of the type of flaws produced by loose parts wearing into the outside diameter of steam generator tubing.

Page: 54 of 56

. 1.

2.
3.
4.
5.
7.
9.
10.

118.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) NIA.

Commercial Service Date 10/13/81.

6. National Board Number for Unit NIA.

Components inspected: (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/99.

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations for Refueling Outage #10 (Cont'd):

118.15 Steam Generator Tube Eddy Current Inspection per Technical Specification 4.4.6.0 (Cont'd) 118.15.12 Previous "SOD" Indications Results of the +Point examination from 2R9 categorized several tube supports with "shallow outside diameter" indications that were programmed to be ran with the +point probe again this outage. These indications either disappeared from the data due to chemical cleaning, or exhibited no change in signal characteristics from 2R9 to 2R10. All SOD indications are subsequently NDD'd or NDF'd, with no further action required during the next refueling Page: 55 of 56

. 1.

2.
3.
4.
5.
7.
9.
10.
11.
12.
13.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ 07101 Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 Plant Unit: Unit 2 (Facility Operating License DPR-75)

Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 10/13/81.

T National Board Number for Unit N/A.

Components inspected : (See pages 1 & 2)

8. Exam Dates 02/16/95 to 05/28/9~

Inspection Interval from 05/10/92 to 01/03/05 Applicable Edition of ASME Section XI 1986.

Abstract of Examinations.

Abstract of Conditions Noted.

Abstract of Corrective Measures Recommended and Taken.

Note: *See the following attached documents:

ISi RFO Exam Results (S2RF0#09, Rev. 0)

ISi RFO Exam Results (S2RF0#10, Rev. 2)

(See pages 2 - 55)

(See pages 2 - 55)

(See pages 2 - 55 *)

We certify that the statements made in this report are correct and the examinations And corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) __ P_S_L='.::..--=~---

( IL/ft Date

~/t) 19 if Signed __ {J.___5;-=£~G:'------

Owner I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of New Jersey and employed by Protection Mutual Insurance Company, OBA Factory Mutual Engineering Association, have inspected the components described in this Owner's Report during the period February 16, 1995 to May 28, 1999, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • ?£:2 -

Commissions N(:J./£&:2.7 :i:BN'4 * ;.l;f/o;;tD


tC....:::-::..::_-:-~:-:==:::::!:::=-£-t::=:::::r---

National Board, State, Province, and Endorsement Date I 8 l/1J usf=

19 qq Page: 56 of 56

\\,,

ENCLOSURE 2 EXAM RESULTS FOR NINTH EXTENDED OUTAGE S2RF0#9, REV. 0