Confirms That 10 Anchor/Darling Model S350W Swing Check Valves Installed at Plant,Per NRC Bulletin 89-002.All 18 Valves Inspected & Retaining Block Studs Replaced W/Upgraded Matl.No Crack Noted on Any Studs Which Were Replaced
ML20059B661
Person / Time
Site: Salem 
Issue date: 08/22/1990
From: Labruna S
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
IEB-89-002, IEB-89-2, NLR-N90162, NUDOCS 9008290218
Download: ML20059B661 (2)


Text

7;

~

1 f<

s e[

'e Public Service Electrk: and Gn Company o

. Stinley LaBruna Public Service Electnc and Gas Jompany P.O. Box 236. Hancocks Bridge, NJ 08038 609 339-4800 Vre PresdeN + Nelear Opesers L

AUG 2 21990 NLR-N90162 United States Nuclear' Regulatory Commission Document Control-Desk Washington, DC 20555 Gentlemen:

CONFIRMATORY LETTER j

BULLI:' PIN 89-02 FACILITY OPERA' PING LICENSE DPR-75

1 SALEM GENERATING STATION UNIT 2
l DOCKET NO. 50-311 l

Public-Service Electric &. Gas Company (PSE&G) has performed a review of-our engineering documentation regarding the types and 1

conposition of swing check valves in use at Salem Unit 2 1

Generating Station in'accordance with Bulletin 89-02.

We hereby confirm that Salem Unit 2 has ten Anchor Darling Model S350W swing check valves.

In-addition, eight Velan swing _

i check valves using'the same type bolting were identified.

During the just completed fifth refueling outage, all eighteen l

~4 valves 5ere inspected and the retaining block studs ~were replaced-with an upgraded' material.

No cracks were noted on any of the studs which were replaced.

1

[.-

A summary of our research is available on site for your review.

[

Should you have any questions regarding this transmittal, please feel free to contact us.

i i

Sincerely, l

g2gg@ Mi$ {

p

$9 p

t

,3y Document Control' Desk 2

AUO. 22 1990 NLR-N90162 C

Mr. J.

C.

Stone Licensing Project Manager Mr.,T. Johnson Senior Resident Inspector L

Mr. T. Martin, Administrator

- Region I i

Mr. Kent Tosch, Chief New Jersey. Department of Environmental Protection Division of Environmental Quality

[

Bureau of Nuclear Engineering Li CN'415 Trenton, NJ 08625 ii T

==

E M

E-mis-vuma-um a rmi am