MONTHYEARML20137N1591997-03-31031 March 1997 Informs That Licensee Facility Scheduled to Administer NRC GFE on 970409.Sonalsts,Inc Authorized Under Contract to Support NRC Administration of GFE Activities ML20058M0361993-04-12012 April 1993 Partial Response to FOIA Request for Documents.Forwards Records in App L Which Are Being Withheld Partially for Listed Reasons,(Ref FOIA Exemptions 5) ML20248D6521989-07-20020 July 1989 Forwards Response to Util Re Bills D0184 & D0185 for Plant OL Application Review Costs by Various Program Ofcs Through June 1984 ML20245D9621989-04-28028 April 1989 Forwards Addl Info Re Bunker Ramo Instrumentation Penetration Modules,Per 890131 Request.Util Believes That Modules Environmentally Qualified in Accordance w/10CFR50.49 & NUREG-0588,Category II ML20205C3521988-09-23023 September 1988 Final Response to FOIA Request for Documents Re Plant. Forwards App D Documents.App D Documents Also Available in PDR ML20155A7001988-06-0202 June 1988 Informs That Const on Conversion of Plant to gas-fired Facility Began on 880404 ML20155A7401988-05-18018 May 1988 FOIA Request for Documents on 850731 & 870312 Meetings Re Plant.Document Re 840314 Meeting Previously Obtained & Therefore Excluded from Request ML20237B4361987-12-14014 December 1987 Final Response to FOIA Request for Documents.App B Document, Board Notification 84-024,encl & Also Available in PDR ML20236X6141987-12-0808 December 1987 Final Response to FOIA Request All Documents.No Addl Records Subj to Request Located ML20236U2571987-11-0505 November 1987 FOIA Request for Documents Re Ball Type Main Steam Isolation Valves Used at Facilities ML20235B3081987-09-21021 September 1987 Responds to FOIA Request for Documents,Including AEC to ACRS Forwarding Safety Evaluation Re Zimmer.App a Documents Cannot Be Located.App B Documents in Pdr.App C & D Documents Withheld (Ref 10CFR2.790) ML20235M4251987-07-13013 July 1987 Partial Response to FOIA Request for Documents Re Acrs. Forwards Documents for Categories One & Three of FOIA Request.Review of 21 Addl ACRS Documents Continuing ML20235K1731987-07-0909 July 1987 Partial Response to FOIA Request for Info Re Certain Contracts Awarded by NRC for Reporting Svcs.Forwards App a & B Documents.Documents Also Available in PDR ML20234F0911987-06-26026 June 1987 Responds to Appeal Re Denial of FOIA Request for Documents. Forwards Document 5 in App F.Portions of Document 5 Withheld (Ref FOIA Exemptions 6 & 7).Other Requested Documents Withheld (Ref FOIA Exemption 6) ML20215K1981987-06-19019 June 1987 Final Response to FOIA Request for Documents Re Allegations Concerning Plant.Forwards App G & H Documents.Documents Also Available in Pdr.App H Documents Partially Withheld (Ref FOIA Exemption 6) ML20213F9351987-05-0808 May 1987 Partial Response to FOIA Request.Forwards App F Document & Weld Allegations.App G Documents Partially Withheld (Ref FOIA Exemption 6) ML20206H4951987-04-13013 April 1987 Partial Response to FOIA Request for Documents Re Bechtel Employment Discrimination.Forwards App E Documents.App D Documents Withheld (Ref FOIA Exemption 6) ML20235G2321987-04-0101 April 1987 FOIA Request for Documents Re Forged NDE Inspectors Certification Supplied by Barclay Intl for Use at Quad Cities Nuclear Station & Stated Investigations at Plants ML20211A9531987-02-13013 February 1987 Advises That Financial Info Submitted for 1987 in Util Satisfies Requirements of 10CFR140.21 That Each Licensee Maintain Guarantee of Payment of Deferred Premiums for Operating Reactors Over 100 Mwe ML20212M7651987-01-16016 January 1987 Informs That Due to Demands on Staff,Nrc Will Respond by 870430 to 850607 Request for Review of Invoices D0184 & D0185 Re OL Application Review Costs Through 840623 ML20207C0151986-12-19019 December 1986 Forwards Notice of Withdrawal of Application for OLs & Termination of Proceeding,Per Util 860711 Request & ASLB 861217 Memorandum & Order Granting Motion ML20207C1191986-12-18018 December 1986 Forwards Order Terminating CPPR-81 & CPPR-82 Based on Fact That Const of Facility Ceased,Units Inoperable & Site Environmentally Stable,Per Util 860701 Request to Withdraw Application to Amend CPs ML20215B9641986-12-0505 December 1986 Notifies Util of 870204-05 Early Emergency Responders Workshop in Chicago,Il to Discuss Lessons Learned & Current Problems in Coordination & Integration of Emergency Response Efforts.Meeting Agenda & Preregistration Form Encl ML20214Q0911986-11-24024 November 1986 Partial Response to FOIA Request for Documents Re Ofc of Inspector & Auditor Investigations.Forwards App B Documents. Documents Also Available in PDR ML20214A0761986-11-14014 November 1986 Forwards Insp & Evaluation of Plant for Adequacy of Stabilization Plan,Documenting 861015-16 Site Insp & Review & Insp of Site Stabilization Rept.Environ Stabilization Satisfactory ML20215N0241986-10-28028 October 1986 Forwards Order from DOE Economic Regulatory Admininstration Granting Exemption from Prohibitions of Power Plant & Industrial Fuel Act of 1978 & Puc of Mi Opinion & Order Granting Relief from Commission 850329 Rate Order ML20215M8851986-10-28028 October 1986 Forwards Insp Repts 50-329/86-01 & 50-330/86-01 on 861015-16.No Violations Identified ML20211B5401986-10-0909 October 1986 Further Response to FOIA Request for Eight Categories of Documents Re Ee Kent Allegations Concerning Facilities. Forwards Documents Listed in App K ML20210S9971986-10-0202 October 1986 Requests Change in Facility Svc List Address to Ref Address. Related Correspondence ML20210S4131986-09-26026 September 1986 Further Response to FOIA Request for 16 Categories of Records Re Facilities.Forwards App D & E Documents.Documents Also Available in PDR ML20214T7431986-09-24024 September 1986 Forwards Form 8-K Filed W/Securities & Exchange Commission. Util Believes Info Presented Bears No Issues Currently Before Aslb.Related Correspondence ML20214N4541986-09-0808 September 1986 Provides List of Activities Re Remedial Soils Work Being Modified Pending Final Disposition of Issues Described in Util 860701 & Counsel s Withdrawing Request for CP Extension.W/Svc List.Related Correspondence ML20209E6621986-09-0505 September 1986 Responds to FOIA Request for Documents Re Util Response to NRC 840112 Confirmatory Order.Documents Listed on App Available in PDR IA-86-235, Responds to FOIA Request for Documents Re Util Response to NRC 840112 Confirmatory Order.Documents Listed on App Available in PDR1986-09-0505 September 1986 Responds to FOIA Request for Documents Re Util Response to NRC 840112 Confirmatory Order.Documents Listed on App Available in PDR ML20212K9061986-08-21021 August 1986 Forwards Request for Addl Info Re Environ Review of Util 860711 Request to Withdraw Applications for OL by 860828 ML20206M8311986-08-15015 August 1986 Forwards Util Response to ASLB 860716 Order.W/O Encl.Related Correspondence ML20212J1391986-07-25025 July 1986 Forwards ALAB-106 Monthly Rept for June 1986.Listed Nonconformance Repts & Addl Documents Closed During June Encl ML20207D7261986-07-11011 July 1986 Forwards Motion for Authorization to Withdraw OL Application & for Dismissal of OL & Order of Mod Proceedings & Motion for Termination of Aslab Jurisdiction.W/O Encl.Related Correspondence ML20202F9581986-07-11011 July 1986 Forwards Util Motion for Authorization to Withdraw OL Application & for Dismissal of OL & Order of Mod Proceedings & Motion for Termination of Appeal Board Jurisdiction,For Filing.W/O Encl ML20203B2351986-07-10010 July 1986 Informs That Review of 820622 Application to Receive Unirradiated Nuclear Fuel Assemblies Terminated,Per .Fission Chambers Should Be Disposed of & Licenses SNM-1904 & SNM-1905 Terminated,Per 10CFR70.38(b) ML20206T2401986-07-0101 July 1986 Advises That Since Facility Formally Abandoned as Nuclear Facility,Util Will Not Reply to Generic Ltr 86-05 Re TMI Action Item II.K.3.5 ML20202B1091986-07-0101 July 1986 Forwards Evaluation of 13 Specific Recommendations Contained in BNL Rept of Review of Surveillance & Maint Program,In Response to CE Norelius 860506 Request ML20206T4321986-07-0101 July 1986 Withdraws Application for Ols.Facility Will Be Converted to combined-cycle gas-fired Plant.Abandonment Actions & Equipment Sales Will Provide Assurance That Plant Cannot Be Used as Nuclear Facility ML20199J9181986-06-30030 June 1986 Submits ALAB-106 Quarterly Rept 51.No New Individuals Assigned quality-related Duties.Const Shut Down Since 840716 & No Const Activities Projected for Jul-Sept 1986 ML20211L0361986-06-25025 June 1986 Forwards Bechtel & B&W Nonconformance Repts for May 1986,per Memorandum & Order ALAB-106 ML20198E9051986-05-25025 May 1986 Forwards ALAB-106 Monthly Rept for Apr 1986,including Nonconformance Repts,Quality Action Requests,Equality Audit Finding,B&W Repts of Nonconformance & Audit Finding Repts. Only Nonconformance Repts Encl ML20205P9331986-05-23023 May 1986 Responds to Generic Ltr 86-10, Implementation of Fire Protection Requirements. Project in Surveillance & Maint Mode.Generic Ltr & FSAR Update Will Be Reviewed When Project Restarted ML20203Q2891986-05-0606 May 1986 Forwards BNL Technical Rept, Surveillance & Maint..., Based on NRC 851014-18 Insp.No Violations Noted.Items Identified Could Have Impact on Later Project Restart. Evaluation of Rept Recommendations Requested within 60 Days ML20203N3901986-05-0101 May 1986 Forwards Rev 2 to Tdi Owners Group App Ii:Generic Maint Matrix & Justifications. Rev Approved by Tdi Owners Group & Tdi ML20205N5861986-04-29029 April 1986 Forwards Corrected Page 1 to JW Cook to H Berkow Re Pipe Whip Restraint Design.Last Line Inadvertently Eliminated When Ltr Originally Issued 1997-03-31
[Table view] Category:INCOMING CORRESPONDENCE
MONTHYEARML20245D9621989-04-28028 April 1989 Forwards Addl Info Re Bunker Ramo Instrumentation Penetration Modules,Per 890131 Request.Util Believes That Modules Environmentally Qualified in Accordance w/10CFR50.49 & NUREG-0588,Category II ML20155A7001988-06-0202 June 1988 Informs That Const on Conversion of Plant to gas-fired Facility Began on 880404 ML20155A7401988-05-18018 May 1988 FOIA Request for Documents on 850731 & 870312 Meetings Re Plant.Document Re 840314 Meeting Previously Obtained & Therefore Excluded from Request ML20236U2571987-11-0505 November 1987 FOIA Request for Documents Re Ball Type Main Steam Isolation Valves Used at Facilities ML20216E4721987-05-28028 May 1987 Part 21 Rept 140 Re Potential Defect in Air Pressure Regulators Mfg by Bellofram.Dripwell Gasket May Fail Due to Mismachining of Gasket Seating Surface Causing Loss of Control Air & Starting Air Pressure ML20235G2321987-04-0101 April 1987 FOIA Request for Documents Re Forged NDE Inspectors Certification Supplied by Barclay Intl for Use at Quad Cities Nuclear Station & Stated Investigations at Plants ML20215N0241986-10-28028 October 1986 Forwards Order from DOE Economic Regulatory Admininstration Granting Exemption from Prohibitions of Power Plant & Industrial Fuel Act of 1978 & Puc of Mi Opinion & Order Granting Relief from Commission 850329 Rate Order ML20210S9971986-10-0202 October 1986 Requests Change in Facility Svc List Address to Ref Address. Related Correspondence ML20214T7431986-09-24024 September 1986 Forwards Form 8-K Filed W/Securities & Exchange Commission. Util Believes Info Presented Bears No Issues Currently Before Aslb.Related Correspondence ML20214N4541986-09-0808 September 1986 Provides List of Activities Re Remedial Soils Work Being Modified Pending Final Disposition of Issues Described in Util 860701 & Counsel s Withdrawing Request for CP Extension.W/Svc List.Related Correspondence ML20206M8311986-08-15015 August 1986 Forwards Util Response to ASLB 860716 Order.W/O Encl.Related Correspondence ML20212J1391986-07-25025 July 1986 Forwards ALAB-106 Monthly Rept for June 1986.Listed Nonconformance Repts & Addl Documents Closed During June Encl ML20207D7261986-07-11011 July 1986 Forwards Motion for Authorization to Withdraw OL Application & for Dismissal of OL & Order of Mod Proceedings & Motion for Termination of Aslab Jurisdiction.W/O Encl.Related Correspondence ML20202F9581986-07-11011 July 1986 Forwards Util Motion for Authorization to Withdraw OL Application & for Dismissal of OL & Order of Mod Proceedings & Motion for Termination of Appeal Board Jurisdiction,For Filing.W/O Encl ML20206T4321986-07-0101 July 1986 Withdraws Application for Ols.Facility Will Be Converted to combined-cycle gas-fired Plant.Abandonment Actions & Equipment Sales Will Provide Assurance That Plant Cannot Be Used as Nuclear Facility ML20202B1091986-07-0101 July 1986 Forwards Evaluation of 13 Specific Recommendations Contained in BNL Rept of Review of Surveillance & Maint Program,In Response to CE Norelius 860506 Request ML20206T2401986-07-0101 July 1986 Advises That Since Facility Formally Abandoned as Nuclear Facility,Util Will Not Reply to Generic Ltr 86-05 Re TMI Action Item II.K.3.5 ML20199J9181986-06-30030 June 1986 Submits ALAB-106 Quarterly Rept 51.No New Individuals Assigned quality-related Duties.Const Shut Down Since 840716 & No Const Activities Projected for Jul-Sept 1986 ML20211L0361986-06-25025 June 1986 Forwards Bechtel & B&W Nonconformance Repts for May 1986,per Memorandum & Order ALAB-106 ML20198E9051986-05-25025 May 1986 Forwards ALAB-106 Monthly Rept for Apr 1986,including Nonconformance Repts,Quality Action Requests,Equality Audit Finding,B&W Repts of Nonconformance & Audit Finding Repts. Only Nonconformance Repts Encl ML20205P9331986-05-23023 May 1986 Responds to Generic Ltr 86-10, Implementation of Fire Protection Requirements. Project in Surveillance & Maint Mode.Generic Ltr & FSAR Update Will Be Reviewed When Project Restarted ML20203N3901986-05-0101 May 1986 Forwards Rev 2 to Tdi Owners Group App Ii:Generic Maint Matrix & Justifications. Rev Approved by Tdi Owners Group & Tdi ML20205N5861986-04-29029 April 1986 Forwards Corrected Page 1 to JW Cook to H Berkow Re Pipe Whip Restraint Design.Last Line Inadvertently Eliminated When Ltr Originally Issued ML20197F8331986-04-28028 April 1986 Advises That Response to Generic Ltr 86-04 Re Engineering Expertise on Shift Inapproriate at Present Because Midland Not Currently Under Const.Commitment to Provide Info Will Be Added to Commitment Tracking Sys ML20210L2351986-04-25025 April 1986 Forwards ALAB-106 Monthly Rept for Mar 1986,including Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts & Quality Audit Findings ML20203K8531986-04-23023 April 1986 Responds to NRC Re Allegation Concerning Adequacy of Pipe Whip Restraint Design.Project Records Placed in Storage & Personnel Performing Work Dispersed.Specific Design Approach Would Require Check of Records at Bechtel ML20203P1661986-04-21021 April 1986 Discusses 860407 Study Considering Options for Facility. Options Range from Abandonment of Facility to Completion as Nuclear Plant.Conversion of Plant to Combined Cycle gas-fired Plant Chosen as Most Favorable Option ML20209E6531986-03-28028 March 1986 FOIA Request for Documents Re Util Response to NRC 840112 Confirmatory Order ML20140F8781986-03-25025 March 1986 Forwards ALAB-106 Monthly Rept for Feb 1986,including Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts & Quality Audit Findings ML20154H9651986-02-25025 February 1986 Forwards Nonconformance Repts Written or Closed During Jan 1986,per Memorandum & Order ALAB-106 ML20154D3581986-02-24024 February 1986 Confirms Items Agreed Upon in 860219 Telcon Re soil-related Issues.Util Will Discontinue Monitoring Dike Groundwater Wells During Shutdown & Site Maint.Authorization Given to Seal Weeping Wall Crack ML20198H2401986-01-24024 January 1986 Forwards ALAB-106 Monthly Rept for Dec 1985,including Bechtel Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts & Quality Audit Findings ML20136F4771985-12-31031 December 1985 Forwards PNL-5718, Review of Tdi Diesel Generator Owners Group Engine Requalification Program,Final Rept, Technical Evaluation Rept ML20138Q5531985-12-31031 December 1985 Submits ALAB-106 Quarterly Rept 50.No New Individuals Assigned quality-related Duties Since 850930 Rept & No Const Activities Projected for Jan-Mar 1986 ML20136C5711985-12-20020 December 1985 Forwards Monthly Rept for Nov 1985,including Bechtel Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts,Quality Audit Findings,B&W Repts of Nonconformity & Util Nonconformance Repts,Per ALAB-106 ML20138Q3871985-12-13013 December 1985 Ack Receipt of 851115 IE Bulletin 85-003, Motor-Operated Valve Common Mode Failures During Plant Transients Due to Improper Switch Settings. Valve Operability Program & Rept Scheduled to Be Completed Prior to OL Issuance ML20137Z1481985-11-27027 November 1985 Advises That Response to 851029 IE Bulletin 85-001, Steam Binding of Auxiliary Feedwater Pumps, Inappropriate at Present Since Plant in Surveillance & Maint Status.Schedule for Response Will Be Provided When Status Changes ML20137F2541985-11-25025 November 1985 Forwards ALAB-106 Monthly Rept for Oct 1985,including Bechtel Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts & Quality Audit Findings,Per 730323 Order ALAB-106 & Amend 1 to Cp.Svc List Encl ML20138J4431985-10-25025 October 1985 Forwards Monthly Rept for Sept 1985,per Memorandum & Order ALAB-106 & Amend 1 to Cp,Including Bechtel Nonconformance Rept,Quality Action Requests,Mgt Corrective Action Repts, Quality Audit Findings & B&W Repts of Nonconformity ML20138D0031985-10-14014 October 1985 Informs That Util Will Submit Schedule for Meeting Requirements of 10CFR50.62(d) Per Generic Ltr 85-06 Re QA Guidance for ATWS nonsafety-related Equipment When & If Project Reactivated ML20133F7581985-10-0808 October 1985 Informs of Plans to Physically Disable Equipment Installed in & About Evaporator Bldg to Serve Process Steam to Dow Chemical Co,Per 850925 Resolution.Equipment & Structures Abandoned Are non-Q.Related Correspondence ML20137Y7921985-09-30030 September 1985 Submits Quarterly Rept 49,per ALAB-106.No New Individuals Assigned to quality-related Duties.Const at Plant Shut Down on 840716.No Const Projected for Fourth Quarter 1985.Next Quarterly Rept Will Be Submitted by End of Dec 1985 ML20133A3141985-09-27027 September 1985 Forwards Review of Section 4.7 of Technical Evaluation Rept PNL-5600, Review of Resolution of Known Problems in Engine Components for Tdi Emergency Diesel Generators, Reflecting Views Re Crankshafts for 16-cylinder Engines ML20133H1261985-09-25025 September 1985 Forwards Bechtel Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts & Quality Audit Findings Written or Closed During Aug 1985,per Condition of Memorandum & Order ALAB-106 ML20138S0731985-09-17017 September 1985 Advises That Addl Excavation Between Tank Farm & Auxiliary Bldg Will Be Conducted Per NRC 850826 Authorization. Excavation Needed to Provide Supplemental Cathodic Protection.Svc List Encl.Related Correspondence ML20133H8841985-09-16016 September 1985 Discusses Ee Kent Allegations Re Plant,Per Encl . Decision Reflected in NRC Should Be Reconsidered. B Garde & T Devine of Gap Unwilling to Testify for Kent.Kent & Counsel Unable to Produce Expert Witnesses ML20140G8331985-08-23023 August 1985 FOIA Request for ACRS Documents Re Facility ML20137F7061985-08-12012 August 1985 Forwards Listed Documents Written or Closed During Jul 1985, in Accordance w/730323 Memorandum & Order ALAB-106 & Amend 1 to Cp.Only Nonconformance Repts Encl ML20133L8331985-08-0909 August 1985 Forwards Attachment 1 to Revised Exhibit D of Revised Compliance Filing & Application for Authorization to Issue Securities.Plan Is Requirement of Agreements W/Banks to Restructure Outstanding Debt.Related Correspondence ML20132B1841985-07-19019 July 1985 Forwards Monthly Repts for May & June 1985 Per Condition of 730323 Memorandum & Order ALAB-106 & Amend 1 to Cp.Related Correspondence 1989-04-28
[Table view] Category:UTILITY TO NRC
MONTHYEARML20245D9621989-04-28028 April 1989 Forwards Addl Info Re Bunker Ramo Instrumentation Penetration Modules,Per 890131 Request.Util Believes That Modules Environmentally Qualified in Accordance w/10CFR50.49 & NUREG-0588,Category II ML20155A7001988-06-0202 June 1988 Informs That Const on Conversion of Plant to gas-fired Facility Began on 880404 ML20155A7401988-05-18018 May 1988 FOIA Request for Documents on 850731 & 870312 Meetings Re Plant.Document Re 840314 Meeting Previously Obtained & Therefore Excluded from Request ML20215N0241986-10-28028 October 1986 Forwards Order from DOE Economic Regulatory Admininstration Granting Exemption from Prohibitions of Power Plant & Industrial Fuel Act of 1978 & Puc of Mi Opinion & Order Granting Relief from Commission 850329 Rate Order ML20214N4541986-09-0808 September 1986 Provides List of Activities Re Remedial Soils Work Being Modified Pending Final Disposition of Issues Described in Util 860701 & Counsel s Withdrawing Request for CP Extension.W/Svc List.Related Correspondence ML20212J1391986-07-25025 July 1986 Forwards ALAB-106 Monthly Rept for June 1986.Listed Nonconformance Repts & Addl Documents Closed During June Encl ML20206T2401986-07-0101 July 1986 Advises That Since Facility Formally Abandoned as Nuclear Facility,Util Will Not Reply to Generic Ltr 86-05 Re TMI Action Item II.K.3.5 ML20202B1091986-07-0101 July 1986 Forwards Evaluation of 13 Specific Recommendations Contained in BNL Rept of Review of Surveillance & Maint Program,In Response to CE Norelius 860506 Request ML20206T4321986-07-0101 July 1986 Withdraws Application for Ols.Facility Will Be Converted to combined-cycle gas-fired Plant.Abandonment Actions & Equipment Sales Will Provide Assurance That Plant Cannot Be Used as Nuclear Facility ML20199J9181986-06-30030 June 1986 Submits ALAB-106 Quarterly Rept 51.No New Individuals Assigned quality-related Duties.Const Shut Down Since 840716 & No Const Activities Projected for Jul-Sept 1986 ML20211L0361986-06-25025 June 1986 Forwards Bechtel & B&W Nonconformance Repts for May 1986,per Memorandum & Order ALAB-106 ML20198E9051986-05-25025 May 1986 Forwards ALAB-106 Monthly Rept for Apr 1986,including Nonconformance Repts,Quality Action Requests,Equality Audit Finding,B&W Repts of Nonconformance & Audit Finding Repts. Only Nonconformance Repts Encl ML20205P9331986-05-23023 May 1986 Responds to Generic Ltr 86-10, Implementation of Fire Protection Requirements. Project in Surveillance & Maint Mode.Generic Ltr & FSAR Update Will Be Reviewed When Project Restarted ML20203N3901986-05-0101 May 1986 Forwards Rev 2 to Tdi Owners Group App Ii:Generic Maint Matrix & Justifications. Rev Approved by Tdi Owners Group & Tdi ML20205N5861986-04-29029 April 1986 Forwards Corrected Page 1 to JW Cook to H Berkow Re Pipe Whip Restraint Design.Last Line Inadvertently Eliminated When Ltr Originally Issued ML20197F8331986-04-28028 April 1986 Advises That Response to Generic Ltr 86-04 Re Engineering Expertise on Shift Inapproriate at Present Because Midland Not Currently Under Const.Commitment to Provide Info Will Be Added to Commitment Tracking Sys ML20210L2351986-04-25025 April 1986 Forwards ALAB-106 Monthly Rept for Mar 1986,including Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts & Quality Audit Findings ML20203K8531986-04-23023 April 1986 Responds to NRC Re Allegation Concerning Adequacy of Pipe Whip Restraint Design.Project Records Placed in Storage & Personnel Performing Work Dispersed.Specific Design Approach Would Require Check of Records at Bechtel ML20203P1661986-04-21021 April 1986 Discusses 860407 Study Considering Options for Facility. Options Range from Abandonment of Facility to Completion as Nuclear Plant.Conversion of Plant to Combined Cycle gas-fired Plant Chosen as Most Favorable Option ML20140F8781986-03-25025 March 1986 Forwards ALAB-106 Monthly Rept for Feb 1986,including Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts & Quality Audit Findings ML20154H9651986-02-25025 February 1986 Forwards Nonconformance Repts Written or Closed During Jan 1986,per Memorandum & Order ALAB-106 ML20154D3581986-02-24024 February 1986 Confirms Items Agreed Upon in 860219 Telcon Re soil-related Issues.Util Will Discontinue Monitoring Dike Groundwater Wells During Shutdown & Site Maint.Authorization Given to Seal Weeping Wall Crack ML20198H2401986-01-24024 January 1986 Forwards ALAB-106 Monthly Rept for Dec 1985,including Bechtel Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts & Quality Audit Findings ML20138Q5531985-12-31031 December 1985 Submits ALAB-106 Quarterly Rept 50.No New Individuals Assigned quality-related Duties Since 850930 Rept & No Const Activities Projected for Jan-Mar 1986 ML20136C5711985-12-20020 December 1985 Forwards Monthly Rept for Nov 1985,including Bechtel Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts,Quality Audit Findings,B&W Repts of Nonconformity & Util Nonconformance Repts,Per ALAB-106 ML20138Q3871985-12-13013 December 1985 Ack Receipt of 851115 IE Bulletin 85-003, Motor-Operated Valve Common Mode Failures During Plant Transients Due to Improper Switch Settings. Valve Operability Program & Rept Scheduled to Be Completed Prior to OL Issuance ML20137Z1481985-11-27027 November 1985 Advises That Response to 851029 IE Bulletin 85-001, Steam Binding of Auxiliary Feedwater Pumps, Inappropriate at Present Since Plant in Surveillance & Maint Status.Schedule for Response Will Be Provided When Status Changes ML20137F2541985-11-25025 November 1985 Forwards ALAB-106 Monthly Rept for Oct 1985,including Bechtel Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts & Quality Audit Findings,Per 730323 Order ALAB-106 & Amend 1 to Cp.Svc List Encl ML20138J4431985-10-25025 October 1985 Forwards Monthly Rept for Sept 1985,per Memorandum & Order ALAB-106 & Amend 1 to Cp,Including Bechtel Nonconformance Rept,Quality Action Requests,Mgt Corrective Action Repts, Quality Audit Findings & B&W Repts of Nonconformity ML20138D0031985-10-14014 October 1985 Informs That Util Will Submit Schedule for Meeting Requirements of 10CFR50.62(d) Per Generic Ltr 85-06 Re QA Guidance for ATWS nonsafety-related Equipment When & If Project Reactivated ML20137Y7921985-09-30030 September 1985 Submits Quarterly Rept 49,per ALAB-106.No New Individuals Assigned to quality-related Duties.Const at Plant Shut Down on 840716.No Const Projected for Fourth Quarter 1985.Next Quarterly Rept Will Be Submitted by End of Dec 1985 ML20133H1261985-09-25025 September 1985 Forwards Bechtel Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts & Quality Audit Findings Written or Closed During Aug 1985,per Condition of Memorandum & Order ALAB-106 ML20138S0731985-09-17017 September 1985 Advises That Addl Excavation Between Tank Farm & Auxiliary Bldg Will Be Conducted Per NRC 850826 Authorization. Excavation Needed to Provide Supplemental Cathodic Protection.Svc List Encl.Related Correspondence ML20140G8331985-08-23023 August 1985 FOIA Request for ACRS Documents Re Facility ML20137F7061985-08-12012 August 1985 Forwards Listed Documents Written or Closed During Jul 1985, in Accordance w/730323 Memorandum & Order ALAB-106 & Amend 1 to Cp.Only Nonconformance Repts Encl ML20132B1841985-07-19019 July 1985 Forwards Monthly Repts for May & June 1985 Per Condition of 730323 Memorandum & Order ALAB-106 & Amend 1 to Cp.Related Correspondence ML20128M1471985-07-19019 July 1985 Forwards Nonconformance Repts for May & June 1985,per 730323 Memorandum & Order ALAB-106 & Amend 1 to Facility CP ML20140G3691985-06-28028 June 1985 Responds to Generic Ltr 85-07,dtd 850502,re Implementation of Integrated Schedules for Plant Mods.Util Will Initiate Participation in Integrated Living Schedule If Project Reactivated.Survey Form Encl ML20127P1951985-06-28028 June 1985 Submits Quarterly Rept 48 Per ALAB-106.Const Shut Down Since 840716.No Const Activities Projected for Jul-Oct 1985.Next Rept Will Be Sent by End of Sept 1985 ML20128B8131985-06-20020 June 1985 Confirms 850610 Telcon W/D Hood Re Detailed Schedule for Shunt Trip Mods & Tech Spec Rev Established Per Generic Ltr 83-28,Items 4.3 & 4.4 (Generic Ltr 85-10).Schedule Commitment Entered Into Commitment Tracking Sys ML20127A9901985-06-17017 June 1985 Responds to Generic Ltr 85-02 Re Recommended Actions to Assure Steam Generator Tube Integrity & Rupture Mitigation. Facility Steam Generators in long-term Dry Layup Since Project Shut Down in Jul 1984 ML20126K2871985-06-0707 June 1985 Requests Extension of Due Date for Payment of Bill to Facilitate Resolution of Contested Fees.Conference to Discuss Billing Procedures Also Requested.Review of Info Re Bills Do 184 & Do 185 Encl ML20129B7261985-05-25025 May 1985 Forwards Bechtel Nonconformance Repts,Quality Audit Findings,B&W Repts of Nonconformity,Util Nonconformance Repts,Audit Finding Repts & Quality Action Requests for Apr 1985,per ALAB-106 ML20133C3771985-05-24024 May 1985 Responds to Request for Info on Item 13 in BNL Rept Re Exposure Time of Low Hydrogen Electrodes to Environ After Removal from Hermetically Sealed Containers or Drying/ Storage Ovens.Related Correspondence ML20133D9421985-05-0707 May 1985 Confirms 850426 Telcon Re Backfilling Number of Excavations of Site.Excavations Left Open Due to Removal of Temporary Freezewall Apparatus Last Fall.M Sinclair Response to Aslab 850423 Order & Svc List Encl ML20117J6761985-05-0707 May 1985 Submits ALAB-106 Quarterly Rept 47.No New Individuals Assigned quality-related Duties Since Last Rept.No Const Activities Projected for Apr-June 1985.Next Rept Will Be Sent in June 1985 ML20117G0641985-04-29029 April 1985 Responds to 850425 Request for Addl Info Re Recent Organizational Changes,Per 850425 Telcon.Announcement Involves Resolution of Legal Proceeding Surrounding Project & Possible Sale of Facilities ML20116E8611985-04-25025 April 1985 Forwards Bechtel & Util Nonconformance Repts,Quality Action Requests,Mgt Corrective Action Repts,Quality Audit Findings & B&W Repts of Nonconformity for Jan & Feb 1985,per Memorandum & Order ALAB-106 ML20117G0831985-04-22022 April 1985 Informs of Reorganization Changes to Increase Efficiency of Energy Supply & Assimilate Certain Portions of Projects, Engineering & Const Organization ML20116D3371985-04-19019 April 1985 Ack Receipt of Jan 1985 BNL Rept Re Welding Allegations Encl w/850322 Ltr.Portion of Issues Closed.Remaining Open Issues Impracticable to Close Due to Lack of Resources. Investigation May Resume in Event of Restart 1989-04-28
[Table view] |
Text
. ,
9- e
@ Consumels Power James W Cook f Vice President - Projects, Engineering and Construction i General officos: 1945 West arnell Road, Jackson, MI 49201 * (517) 788 0453 April 15, 1983 Harold R Denton, Director Office of Nuclear Reactor Regulation Division of Licensing US Nuclear Regulatory Commission Washington, DC 20555 MIDLAND ENERGY CENTER PROJECT MIDLAND DOCKET NOS S0-329, 50-330 FOLLOWUP INFORMATION FOR RESPONSE TO NRC EVALUATION OF PART I SUBMITTAL FOR THE CONTROL OF HEAVY LOADS - NUREG-0612 FILE 0963 SERIAL 22008 Reference (A) J W Cook Letter to H R Denton, Serial 19377, Dated 2/17/83 Enclosure (1) Followup Information for Heavy Load Handling Devices i (2) Followup Information for Bechtel Supplied Special Lift Device (3) Followup Information for B&W Supplied Special Lift Devices Keference (A) submitted CP Co responses to the NRC/EG&G draft Technical Evaluation Report (TER) of the Midland Part I Heavy Load Study. The enclosure to Reference (A) committed CP Co to provide followup information on heavy load handling systems and special lift devices. Enclosures (1), (2) and (3) contain this followup information.
With this information, CP Co believes that the TER open items have been satisfactorily addressed and the Staff can complete their review and issue a final TER and a final safety evaluation on this subject.
JWC/ PEP /fms CC RJCook, Midland Resident Inspector RHernan, US NRC g30 D
LSRubenstein, US NRC DBMiller,_ Midland Construction (3)
RWHu-ton, Washington oc0483-1720a131 8304190453 830415 PDR ADOCK 05000329 A PDR
o .
2 4
CONSUMERS POWER COMPANY Midland Units 1 and 2 Docket No 50-329, 50-330 Letter Serial 22008 Dated April 15, 1983 At the request of the Commission and pursuant to the Atomic Energy Act of 1954, and the Energy Reorganization Act of 1974, as amended and the Commission's Rules and Regulation's thereunder, Consumers Power Company submits the followup response to the NRC/EG&G draft technical evaluation of the Midland Part I Heavy Load Submittal.
- - CONSUMERS POWER COMPANY By JWC k,.Vice Pres ~ident Proj ects agineering and Construction Sworn and subscribed before me this /f" day of [C ///_S.
t yt d/ Mv, -
f Notary Ppfflic - Severly A. Avery l 5
Jackson County, Michigan MyCommissionExpireshwsof// /MI I
r p '
l l
l l.
oc0483-1720a131
.- , Enclosure 1 JWC to HRD Serial 22008 HEAVY LOAD HAhTLING DEVICE DESIGN INFORMATION
- 1. The heavy load TER requested more information on the design of some of the handling systems capable of lifting heavy loads (greater than 1700 lbs).
These systems are:
- a. Filter Plug Hoist
- b. Portable Crane
- c. Rigging Beam - Snubbers
- d. Rigging Beam - Reactor Vessel Head Studs
- e. Rigging Beam - Miscellaneous Equipment (Unit 2 Containment)
- f. Rigging Beam - Letdown Coolers
- g. Rigging Beam - Shield Plugs The filter plug hoist has a 1 ton capacity and is used to lift a shield plug weighing 1050 lbs. The plug is not a heavy load and therefore not a NUREG-0612 concern. The hoist is designed to the requirements of ANSI B30.16-1973.
The portable crane listed in Table 4 of the Midland Part I heavy load response does not exist.
The snubber rigging beams are installed in Unit 1 containment and the plans to install them in Unit 2 containment have been changed. They have not and will not be used.
The remainder of the handling devices listed above are designed to withstand the loads and forces imposed as specified in ANSI B.30.2-1976, Section 2.1.3.2.a.1. The materials used conform to the requirements of CMAA Specification 70-1975, Section 3.1. The general construction of the rigging beams is also in conformance with the applicable portions of Section 11-1.3 of ANSI B30.11-1980 and Section 1.3 of the AISC Manual of Steel Construction, Seventh Edition.
oc0483-1720b131
Enclosure 2 JWC to HRD Serial 22008 COMPARIS0N OF BECHTEL SUPPLIED SPECIAL LIFT DEVICE DESIGN TO SPECIFIC ANSI N14.6-1978 REQUIREMENTS Spreader Beam Type IB 3.1.1 Spreader Beam Type IB and the loads to be lifted in a designated area are specified on the Bechtel drawings. Materials, heat treatment, fabrication practices, inspection and testing, quality assurance, documentation, records retention, and limitations regarding temperature, corrosive environments, etc, are covered in ASTM A 36-77a, A 307-80, AWS DI.1, AISC Manual of Steel Construction (Seventh Edition), and on the drawing notes.
3.1.2 Critical items for a safe lift include all structural components specified on the Bechtel drawing for spreader beam Type IB. Component material identification, qualification, control, and fabrication practices are covered in Section 3.1.1.
. 3.1.3 Signed stress analysis for spreader beam Type IB is included in the Bechtel calculations.
3.1.4 Component replacement would be made if repair. is required.
3.2.1 Spreader lifting beam Type IB is capable of lifting three times the maximum load without exceeding the yield strength, and five times the maximum load without exceeding the ultimate strength of the materials.
These safety factors include allowance for 15% dynamic loading. The yield strength is less than 80 percent of the ultimate strength.
3.2.4 The response to Section 3.2.1 is applicable.
3.2.5 The wire ropes conform to ANSI B30.9-1971.
3.2.6 Charpy impact tests on the materials are required by Specification 7220-C-233 to be in accordance with ASTM A 370.
3.3.1 Spreader beam Type IB is used in the controlled environment within the auxiliary building. The spreader beam is designed so that galling and lamellar tearing are of no concern.
3.3.4 Spreader beam Type IB is designed to ensure equal distribution of the load to all load-bearing attachment points.
3.3.5 Positive locking means cre provided on spreader beam Type IB to ensure load retention for load-carrying components subject to inadvertent
3.3.6 Remote actuating mechanisms are not used in spreader beam Type IB.
oc0483-1720c131
Enclosure 2 JWC to HRD Serial 22008 2
4.1.3 The structural material conforms to the technical standards of ASTM A 36-77a. Other materials provided for parts are proportioned to give comparable design factors.
4.1.4 Fabrication procedures are in accordance with accepted standard practices of AISC and AWS for good workmanship within the industry.
4.1.5 Welding procedures, welders, and welding operators are qualified in keeping with the requirements of the AWS Structural Welding Code, AWS D1.1-72.
4.1.6 The quality cf workmanship is in accordance with the standard practices of the AISC and AWS.
4.1.7 A certificate of conformance is required for identification and certification of materials in accordance with the design drawing.
4.1.9 Certified materials are used by the fabricator.
5.1.3 Periodic testing of this device will be incorporated into our Periodic Activity Control System (PACS).
5.1.4 Use of this device will be covered by the procedure for the heavy load it handles.
5.1.5 This special lift device will be assigned a special tool number and will become part of our tool list. The methodology to be used for identifying limitations has not been finalized.
5.1.6 A full record history of this device will be maintained by the PAC and Maintenance Order Systems. The PACS will have scheduled inspection records while the Maintenance Order will document any repair work and retesting required.
5.1.7 The requirements for removal of this device from service will be specified in the Administrative Control of Heavy Loads Procedure -
Station 1053.1.
5.1.8 At this time we have no plans to employ others to use this special lift device. If such a case arises, the user will be required to operate the device in accordance with our established procedures.
5.2.1 A load test for spreader beam Type IB of 150% of the maximum static plus dynamic load is planned prior to use.
5.2.2 Qualification of replacement parts shall be the same as the original parts.
oc0483-1720c131
Enclosure 2 JWC to HRD Serial 22008 3
5.3.1 This special lift device will 'oe subjected to the periodic testing in accordance with 5.3.1(2). The test interval will depend on how frequent the device is used.
5.3.2 The requirements for load testing after major repairs / alterations will be addressed if and when the need arises.
5.3.4 This device does not have non-load bearing functional parts, therefore, this section is not applicable.
5.3.6 This device will be visually inspected by operating personnel for indications of damage prior to each use.
5.3.7 This device will be visually inspected by maintenance personnel for indications of damage or deformation. The inspection schedule will be based on how frequent this device is used.
6.1-6.3 As noted in our Part II IIeavy Load Response, lifts of some of the degasifier or demineralizer plugs could present a problem. We have no planned maintenance requiring lifts of these plugs, therefore, there are no planned lifts of critical loads for this special Irft device.
oc0483-1720c131
Enclosure 3 JWC to HRD Serial 22008 COMPARISON OF B&W SUPPLIED SPECIAL LIFT DEVICE DESIGN TO SPECIFIC ANSI N14.6-1978 REQUIREMENil These devices are:
A. Reactor Vessel Head and Internals Handling Fixture B. Internals Handling Extension C. Internals Handling Adapter D. Stud Tensioner Sling E. New Fuel Handling Tool and Sling F. Turnbuckle Pendant and Sling 3.1.1 Devices A,B - Materials, fabrication practices, inspection and testing requirements, as applicable, are specified on drawings.
Devices A,B - Have metal tag reflecting test load.
Devices C,D,F - Materials are specified on drawings.
3.1.2 Devices A,B,C,D,E,F - Most of the members which make up these devices will be loaded or perform a locking function, therefore, most members are considered critical.
3.1.3 Devices A,B,C - B&W has sizing calculations for these devices. They have been marked up to include dynamic load factors and the new safety margins.
Devices D,F - B&W has general calculations which include dynamic load factors and revised safety margins.
Device E - B&W has stress report which includes dynamic load factors and revised safety margins.
3.1.4 Devices A,B,C,D,E,F - There is neither a list of permissible repair procedures nor any established criteria for acceptable repair procedures or post repair testing. If repairs become necessary, appropriate actions will be taken.
3.2.1 Devices A,B - These devices are capable of lifting three times the maximum load without exceeding the yield strength, and five times the maximum load without exceeding the ultimate strength of the materials.
The safety margins include a dynamic load allowance of 15% although 2.5% would be sufficient since the only crane capable of handling the loads lifted with these devices is the main boist of the polar crane which has a hoist speed of 5 ft/ min. The safety margins are based on the maximum load of the reactor vessel head plus control rod drive mechanism service structure, approximately 165 tons.
oc0483-1720d131
Enclosure 3 JWC to HRD Serial 22008 2
Device B - Th'e three pins of this device are made of material whose yield strength is greather than 80% of the ultimate strength (87-90%).
Using.a 2.5% dynamic load factor, the safety factors to ultimate range from 8.5 to 10.2.'
Device C.-.This device is capable of lifting 2.4 times the maximum load without exceeding the~ yield strength, and 4.8 times the maximum load without. exceeding the ultimate strength of the materials. The safety margins include a dynamic' load allowance of 15% although 2.5% would be sufficient s.ince the only. crane capable of handling the loads lifted with this device. is the main hoist of. the polar crane which has a hoist speed of 5 ft/ min.' The safety margins are based on the maximum load of the core support assembly (CSA), approximately 130 tons. The limiting part for the 2.4 safety factor to yield are the turnbuckles and the limiting part for the 4.8 safety factor to ultimate are the rods. In addition, the-rod material yield strength is-82% of the ultimate strength and the ultimate strength of the pins used with this device is unknown. Using a 2.5% dynamic load factor, the safety factor to yield
- of the turnbuckles is 2.7 -and the safety factor' to ultimate of the rods is:5.4. -Assuming a yield strength for the pins of 90% of ultimate, the safety factor of the pins to ultimate-is 7.5.
Devices D,E,F - These devices are capable of lifting three times the maximus Joad without exceeding the yield strength, and five times the maximum. load.without'erceeding the ultimate strength of the materials.
The safety. margins include a dynamic load allowance of 15% for devices D & F and 18.5% for Device E.
3.2.4 JDevices A,B,C,D,E,F - See the responses given in.3.2.1 above.
3.2.5 -Devices A,B,C - This~section is not applicable to these devices.
Devices D,F -' Slings used with these devices conform to ANSI B30.9-1971
. requirements.
Device E - Sling was purchased to lift the required load and tested to 3 times the load.
'3.2.6 Devices A,B,C,D,F -No drop weight or Charpy impact tests were performed for the materials-.used in the fabrication of these devices.
Device E - This section-is not applicable since paragraph AM 218 of the ASME Boiler'and Pressure Vessel Code,Section VIII, Division 2 does not address impact testing of stainless steel.
3.3.1 Devices ' A,B,C,D,F -- There are no lamellar tearing problems.
Device E - Lamellar tearing does not apply to this device.
.. oc0483-1720'd131
~
Enclosure 3 JWC to HRD Serial 22008 3
3.3.4~ Devices A,B,C,D,F - These devices are' designed to ensure equal
' distribution of the load to all load-bearing attachment points.
~
Device E - Symmetry of load being lifted assures compliance.
- 3.3.5 ~ Devices A,B,C,D,F - Positive-locking means are provided on these
. devices to ensure load retention for load-carrying components subject to.inadvertant disengagement.
Device E - Projections on grapples prevent opening before load is relaxed._
3.3.6 Devices A,B,D,F - No actuating mechanisms are used to engage or disengage these devices.
Devices C (Latch Block),E Actuating mechanisms are used to engage or disengage these devices.
4.1.3 -Devices A,B,C,E,F - Certificates of conformance are available which
~
state that the materials used in fabrication are in accordance with the device drawings and stress reports.
Device D - A certificate of conformance for material is not available.
4.1.4 Devices A,B,C,F - Certificates of conformance'are available which state that these devices were fabricated in accordance with the detail
. drawings and fabricator quality assurance specifications.
~
Devices D,E - Certificates of conformance for fabrication are not 1
available.
4.1.5 Devices A,B,C - telding procedures,Lwelders'and welding operators were qualified in accordance with ASME Boiler and Pressure Vessel Code -
'Section IX.
Device E - Welding qualification standard was MIL-Q.9858A.
Devices D,F - No welding involved on these devices.
4.1.6 Devices A,B,C (Except Turnbuckles), F (Turnbuckle Pendants Except Turnbuckles) - The fabricator operated in accordance with quality assurance specifications which were written'in accordance with the ASME Boiler and Pressure Vessel Code - Section I and VIII.
Devices C (Turnbuckles Only), D,F (Wire Rope and Turnbuckles) - The
-parts.for these devices were standard stock items that are widely used for load handling operations. They were purchased from suppliers such
- as Roebling, Crosby-Laughlin, Cleveland. City. Forge, US Steel, etc.
Fabrication was under the quality assurance program followed by these oc0483-1720d131 4
Enclosure 3 JWC to HRD Serial 22008 4
suppliers. Suppliers were not requested to comply with 10 CFR 50, App i B.
Device E The Fabricator quality assurance standards were in accordance with MIL-Q.9858A. The Fabricator was not' requested to comply with 10 CFR 50,. App B.
4.1.7 Devices A,B,C,D,E,F - Material identification is provided by the detail
- drawings. Certification of materials is provided by the Certifications of Conformance except for device D. See 4.1.3 response'above.
14.1.9 ~ Devices'A,B,C,D,E,F - No special requirements were invoked on the
. suppliers. See 4.1.3 and 4.1.4 responses above.
. '5.1.3 ' Devices A,B,C,D,E,F - Periodic testing of these devices will be incorporated into our Periodic Activity Control System (PACS).
.5.1.4 Devices A,B,C,D,E,F - Use-of these devices will be covered by the procedures for the heavy loads they handle.
T 5.1.5 Devices A,B,C,D,E,F.- These devices will be assigned'a spccial tool number and will become part of our tool list. -The methodology to be
. used for identifying limitations has not been finalized.
5.16 LDevices A,B,C,D,E,F - A full record history of these devices will be maintained by the PAC and Maintenance Order Systems. The PACS will have sche ~duled inspection records while.the Maintenance Order will ;
- document any repair work and retesting required.
l - 5'.1.7 Devices'A,B,C,D,E,F - The requirements for removal of these devices from service will be specified in the Administrative Control of Heavy Loads Procedure - Station 1053.1. ,
p 5'.1.8-: Devices A,B,C,D,E,F - At this time we have no plans to employ others to use these special lift devices. If such a case arises, the user will be. required to operate'the' device in accordance with our established procedures.
5.:2.1 Devices A,B' C,F :- Initial load tests performed were 150% of the maximum
- static load.and test hold time'was 3-minutes. Static load for these devices was taken as CSA plus plenum, approximately 193' tons. There
_are no requirements or situations where the CSA and plenum will be lifted together, therefore, the maximum load for devices A,B,F is the
' head plus CRDM service structure, and for device C is the CSA. The actual-load tests were in excess of 150% of maximum load plus 15% . . l
- . dynamic load factor. NDT of critical areas, including all load bearing welds was performed. This NDT met the requirements of Section 5.5.1 of l ANSI N14.6-1978. NDT acceptance standards were those written by the fabricator.
oc0483-1720d131 1
. - , w r- .- , _ . - -,.w-,,-, ,_, , , , , .-e , , - .y.,. . - , . . , , , ,,,,., - , - , - , - , ,
I
.c . ~
Enclosure 3
, JWC to HRD Serial 22008 5.
1.
Device'D - No load test'was performed. Because of safety factors of
- 4.07 to yield and 10.19 to ultimate, with a 15% dynamic load allowance,
. no load test is considered necessary.
Device E - The tool was tested to 250% of maximum load and the sling to 300% of maximum load. Dye penetrant inspection was performed on the.
welds.
5.2.2 Devices'A,B,,C,D,E,F - This section does not apply to these devices.
~
5.3.1 Devices A,B,C,D,E,F - These devices will be subjected to periodic testing-in accordance.with 5.3.1(2). The test interval will depend on how frequent-the device is used.
4 5.3.2 Devices A,B,C,D,E,F - The. requirements for load testing after major repairs / alterations will be addressed if and when the need arises.
4 5.3.4 Devices'A,B,C (except latch box) D,E,F - These devices do not have non-
-load bearing functional parts therefore this section'is not applicable.
Device C (latch box) - The latch box is functionally checked by procedure prior to use.
T5.3.6 Devices A,B,C,D,E,F These devices will be visually inspected by
, operating personnel for indications of damage prior to each use.
5
. 3.7 Devices A,B,C,D,E,F - These devices will be visually inspected by maintenance personnel for indications of damage or deformation. The inspection schedule will be based on how aquent the device is used.
6.'l-6.3.2 Devices A,B,C,D,F - These devices do not' handle critical loads therefore the requirements of this-section do not apply.
Device E Handling of a loaded failed fuel container with this device
- is considered' extraordinary maintenance. There are no planned lifts of critical loads for this device.
b r
p
-oc0483-1720d121 l
3 w,m- .~, .- -._m. ,- -. ,.-r - , _ ., ,.r-, - _ - , , - . , , , . ,e- - . . , ,-o,- .,
~
l NRC LICENSING CORRESPONDENCE - RECORD SUhNARY DATE: April 15, 1983 DOCKET NUMBERS. 50-329, 50-330 MIDLAND UNITS 1 & 2
SUMMARY
- (State why letter is written)
This letter forwards te the NRC, CP Co followup information to the open item of the NRC/EG&G draft technical evaluation of the Midland Part I Heavy Load Submittal.
COMMITMENTS MADE: (LCP items will be made for.these items by Safety & Licensing; Site commitments will be identified separately).
- 1. Load test Bechtel supplied special lift device ~- Spreader Beam Assembly IB.
, 2. ' Breakdown of how two commitments from Part I heavy load response will be implemented. These commitments were to inspect, maintain and test special lift devices in accordance with the requirements of Sections 5.1 and 5.3 of ANSI N14.6-1978.
PREVIOUS NRC/CPC0 CORRESPONDENCE SPECIAL DISTRIBUTION (References)
JWC letters to HRD, Serials 14928, US Mail X 15979 and 19377 dtd 12/21/81, 2/26/82 & 2/17/83, respectively. Federal Express NRC ltr-TMN and to JWC dated 8/16/82 File /UFI No Telecopy 0963l To Whom:
INDIVIDUALS PROVIDING INFORMATION INDIVIDUALS ASSIGNED RESPONSIBILITY (Including Consultants) FGR IMPLEMENTING COMMITMENTS:
B&W 1. Bechtel Bechtel 2. GTPollard
^
GBiby CONCURRENCES (normally name of LCP item (s) this correspondence section or department head and name closes:
of any site personnel who' concurred)
LSGibson None.
-GTPollard/GBiby ORIGINATOR (Preparer) Attachments or Enclosures?
PEPapaioannou Yes X How Many? 3 oc0483-1720e131.
. . - . ,