Category:MONTHLY OPERATING ANALYSIS REPORT
MONTHYEARML20217K4591999-09-30030 September 1999 Monthly Operating Repts for Sept 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20216E5061999-08-31031 August 1999 Monthly Operating Repts for Aug 1999 for Vegp,Units 1 & 2. with ML20210P9841999-07-31031 July 1999 Monthly Operating Repts for July 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20209H1211999-06-30030 June 1999 Monthly Operating Repts for June 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20195G1731999-05-31031 May 1999 Monthly Operating Repts for May 1999 for VEGP Units 1 & 2. with ML20206N2141999-04-30030 April 1999 Monthly Operating Repts for Apr 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20205Q8081999-03-31031 March 1999 Monthly Operating Repts for Mar 1999 for Vegp,Units 1 & 2. with ML20206C2291999-03-31031 March 1999 Revised Monthly Operating Repts for Mar 1999 for Vogtle Electric Generating Plant,Units 1 & 2 ML20207K6051999-02-28028 February 1999 Monthly Operating Repts for Feb 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20199E7561998-12-31031 December 1998 Monthly Operating Repts for Dec 1998 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20198B8571998-11-30030 November 1998 Monthly Operating Repts for Nov 1998 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20195H2131998-10-31031 October 1998 Monthly Operating Repts for Oct 1998 for Vogtle Electric Generating Station,Units 1 & 2.With ML20154L5681998-09-30030 September 1998 Monthly Operating Repts for Sept 1998 for Vegp,Units 1 & 2 ML20151W3681998-08-31031 August 1998 Monthly Operating Repts for Aug 1998 for Vogtle Electric Generating Plant Units 1 & 2.With ML20154L5721998-08-31031 August 1998 Corrected Page from MOR for Aug 1998 for Vegp,Unit 2 ML20237D2051998-07-31031 July 1998 Monthly Operating Repts for July 1998 for Vogtle Electric Generating Plant Units 1 & 2 ML20236P6991998-06-30030 June 1998 Monthly Operating Repts for June 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20249A3911998-05-31031 May 1998 Monthly Operating Repts for May 1998 for Vogtle Electric Generating Plant ML20249A3931998-04-30030 April 1998 Revised MOR for Apr 1998 for Vogtle Electric Generating Plant Unit 1 ML20247F3841998-04-30030 April 1998 Monthly Operating Repts for Apr 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20216D6141998-03-31031 March 1998 Monthly Operating Repts for Mar 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20216E2421998-02-28028 February 1998 Monthly Operating Repts for Feb 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20202G5441998-01-31031 January 1998 Monthly Operating Repts for Jan 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20198L6471997-12-31031 December 1997 Monthly Operating Repts for Dec 1997 for Vogtle Electric Generating Plant,Units 1 & 2 ML20203H0601997-11-30030 November 1997 Monthly Operating Repts for Nov 1997 for Vegp,Units 1 & 2 ML20199B6301997-10-31031 October 1997 Monthly Operating Repts for Oct 1997 for Vogtle Electric Generating Plant,Units 1 & 2 ML20217H5991997-09-30030 September 1997 Monthly Operating Repts for Sept 1997 for Vogtle Electric Generating Plant,Units 1 & 2 ML20216H6071997-08-31031 August 1997 Monthly Operating Repts for Aug 1997 for Vogtle Electric Generating Plant ML20210K5081997-07-31031 July 1997 Monthly Operating Repts for July 1997 for VEGP ML20140D7301997-05-31031 May 1997 Monthly Operating Repts for May 1997 for Vogtle Electric Generating Plant ML20141D8531997-04-30030 April 1997 Monthly Operating Repts for Apr 1997 for Vogtle Electric Generating Plant Units 1 & 2 ML20137T6191997-03-31031 March 1997 Monthly Operating Repts for Mar 1997 for Vogtle Electric Generating Plant ML20136G3471997-02-28028 February 1997 Monthly Operating Repts for Feb 1997 for Vogtle Electric Generating Plant Units 1 & 2 ML20134H3481997-01-31031 January 1997 Monthly Operating Repts for Jan 1997 for Vogtle Electric Generating Plant,Units 1 & 2 ML20133F6551996-12-31031 December 1996 Monthly Operating Repts for Dec 1996 for Vogtle Electric Generating Plant,Unit 1 & 2 ML20132B9671996-11-30030 November 1996 Monthly Operating Repts for Nov 1996 for Vogtle Electric Generating Plant Units 1 & 2 ML20134K7361996-10-31031 October 1996 Monthly Operating Repts for Oct 1996 for Vogtle Electric Generating Plant,Units 1 & 2 ML20128N1541996-09-30030 September 1996 Monthly Operating Repts for Sept 1996 for Vogtle Electric Generating Plant,Units 1 & 2 ML20117N1731996-08-31031 August 1996 Monthly Operating Repts for Aug 1996 for Vogtle Electric Generating Plant Units 1 & 2 ML20116J3461996-07-31031 July 1996 Monthly Operating Repts for Jul 1996 for Vogtle Electric Generating Plant Units 1 & 2 ML20115E9821996-06-30030 June 1996 Monthly Operating Repts for June 1996 for Vogtle Electric Generating Plant ML20112H6411996-05-31031 May 1996 Monthly Operating Repts for May 1996 for Vogtle Electric Generating Plant Units 1 & 2 ML20111B2461996-04-30030 April 1996 Monthly Operating Repts for Apr 1996 for Vogtle Electric Generating Plant Units 1 & 2 ML20101R0251996-03-31031 March 1996 Monthly Operating Repts for Mar 1996 for Vogtle Electric Generating Plant ML20100R2701996-02-29029 February 1996 Monthly Operating Repts for Feb 1995 for Vogtle Electric Generating Plant ML20100F2071996-01-31031 January 1996 Monthly Operating Repts for Jan 1996 for Vogtle Electric Generating Plant Units 1 & 2 ML20096C3051995-12-31031 December 1995 Monthly Operating Repts for Dec 1995 for Vogtle Electric Generating Plant,Units 1 & 2 ML20095E0201995-11-30030 November 1995 Monthly Operating Repts for Nov 1995 for Vogtle Electric Generating Plant ML20094J0741995-10-31031 October 1995 Monthly Operating Repts for Oct 1995 for Vogtle Electric Generating Plant Units 1 & 2 ML20093F5031995-09-30030 September 1995 Monthly Operating Repts for Sept 1995 for Vogtle Electric Generating Plant 1999-09-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217K4591999-09-30030 September 1999 Monthly Operating Repts for Sept 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20217K8041999-09-30030 September 1999 Rev 1 to Vegp,Unit 2 Cycle 7 Colr ML20217K7741999-09-30030 September 1999 Rev 1 to Vegp,Unit 1 Cycle 9 Colr ML20216E5061999-08-31031 August 1999 Monthly Operating Repts for Aug 1999 for Vegp,Units 1 & 2. with ML20210P9841999-07-31031 July 1999 Monthly Operating Repts for July 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20209H1211999-06-30030 June 1999 Monthly Operating Repts for June 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20196F9711999-05-31031 May 1999 Owner Rept for ISI for Vogtle Electric Generating Plant, Unit 1 Eighth Maint/Refueling Outage ML20195G1731999-05-31031 May 1999 Monthly Operating Repts for May 1999 for VEGP Units 1 & 2. with ML20206N2141999-04-30030 April 1999 Monthly Operating Repts for Apr 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20206A6561999-04-21021 April 1999 Safety Evaluation Authorizing Licensee Re Rev 9 to First 10-year ISI Interval Program Plan & Associated Requests for Relief (RR) 65 from ASME Boiler & Pressure Vessel Code ML18016A9011999-04-12012 April 1999 Part 21 Rept Re Defect in Component of DSRV-16-4,Enterprise DG Sys.Caused by Potential Problem with Connecting Rod Assemblies Built Since 1986,that Have Been Converted to Use Prestressed Fasteners.Affected Rods Should Be Inspected ML20206C2291999-03-31031 March 1999 Revised Monthly Operating Repts for Mar 1999 for Vogtle Electric Generating Plant,Units 1 & 2 ML20205Q8081999-03-31031 March 1999 Monthly Operating Repts for Mar 1999 for Vegp,Units 1 & 2. with ML20205A9581999-03-31031 March 1999 Rev 0 to VEGP Unit 1 Cycle 9 Colr ML20207K6051999-02-28028 February 1999 Monthly Operating Repts for Feb 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20209H3951999-02-15015 February 1999 Rev 2 to ISI Program Second 10-Year Interval Vogtle Electric Generating Plant Units 1 & 2 ML20209H4091999-02-15015 February 1999 Rev 1 to ISI Program Second 10-Year Interval Vogtle Electric Generating Plant Units 1 & 2 ML20202H9851999-01-29029 January 1999 Safety Evaluation Accepting Rev 8 to First 10-year Interval Inservice Insp Program & Associated Requests for Relief for Vogtle Electric Generating Plant,Unit 1 ML20199F8041999-01-13013 January 1999 Corrected Pages to VEGP-2 ISI Summary Rept for Spring 1998 Maint/Refueling Outage ML20199E7561998-12-31031 December 1998 Monthly Operating Repts for Dec 1998 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20198S1781998-12-31031 December 1998 SER Re Second 10-year Interval Inservice Insp Program Plan & Associated Requests for Relief for Southern Nuclear Operating Co,Inc Units 1 & 2 ML20196E5221998-12-0101 December 1998 Rev 8 to ISI-P-014, ISI Program for VEGP-2 ML20198B8571998-11-30030 November 1998 Monthly Operating Repts for Nov 1998 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20195H2131998-10-31031 October 1998 Monthly Operating Repts for Oct 1998 for Vogtle Electric Generating Station,Units 1 & 2.With ML20154L5681998-09-30030 September 1998 Monthly Operating Repts for Sept 1998 for Vegp,Units 1 & 2 ML20151W3681998-08-31031 August 1998 Monthly Operating Repts for Aug 1998 for Vogtle Electric Generating Plant Units 1 & 2.With ML20154L5721998-08-31031 August 1998 Corrected Page from MOR for Aug 1998 for Vegp,Unit 2 ML20237D2051998-07-31031 July 1998 Monthly Operating Repts for July 1998 for Vogtle Electric Generating Plant Units 1 & 2 ML20236V3121998-07-29029 July 1998 Final Part 21 Rept Re Enterprise DSR-4 & DSRV-4 Edgs.Short Term Instability Was Found During post-installation Testing & Setup as Part of Design mod/post-work Testing Process. Different Methods Were Developed to Correct Problem ML20236P6991998-06-30030 June 1998 Monthly Operating Repts for June 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20236Q3051998-06-30030 June 1998 Owner'S Rept for ISI for Sixth Maint/Refueling Outage of Vogtle Electric Generating Plant,Unit 2 ML20249A3911998-05-31031 May 1998 Monthly Operating Repts for May 1998 for Vogtle Electric Generating Plant ML20248A1671998-05-22022 May 1998 Interim Part 21 Re Enterprise DSR-4 & DSRV-4 Emergency diesel.Post-installation Testing Revealed,High Em/Rfi Levels Affected New Controllers,Whereas Original Controllers Were unaffected.Follow-up Will Be Provided No Later than 980731 ML20249A3931998-04-30030 April 1998 Revised MOR for Apr 1998 for Vogtle Electric Generating Plant Unit 1 ML20247F3841998-04-30030 April 1998 Monthly Operating Repts for Apr 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20154Q9721998-04-20020 April 1998 10CFR50.59(B) Rept of Facility Changes,Tests & Experiments for Vogtle Electric Generating Plant,Units 1 & 2 ML20217H7181998-04-0101 April 1998 Corrected Page 5 to 980324 SER Re Relief Requests Associated W/Second 10-year Interval Insp program.RR-21 in Error in That Component,Suction Damper Inadvertently Omitted. Corrected Page 7 of Technical Ltr Rept Also Encl ML20216D6141998-03-31031 March 1998 Monthly Operating Repts for Mar 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20217Q1301998-03-31031 March 1998 Rev 0 to Vepc Unit 2 Cycle 7,COLR ML20217B8831998-03-24024 March 1998 SER Accepting Relief Request RR-5,RR-19,RR-20,RR-21,RR-23 & RR-24 for Second 10-yr Interval ISI Program Plan ML20216E2421998-02-28028 February 1998 Monthly Operating Repts for Feb 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20203H9551998-02-23023 February 1998 SER Denying Quality Assurance Program Description Change for Vogtle Electric Generating Plant,Units 1 & 2 ML20203E4831998-02-11011 February 1998 Rev 1 to Vogtle Electric Generating Plant,Units 1 & 2 Second Ten-Yr Interval Pump Inservice Test Program ML20198T1211998-01-31031 January 1998 Owners Rept for Inservice Inspection for Seventh Maintenance/Refueling Outage ML20202G5441998-01-31031 January 1998 Monthly Operating Repts for Jan 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20199E5431998-01-31031 January 1998 Rev 3 to WCAP-14720, Vogtle Units 1 & 2 Spent Fuel Rack Criticality Analysis W/Credit for Soluble Boron ML20198L6471997-12-31031 December 1997 Monthly Operating Repts for Dec 1997 for Vogtle Electric Generating Plant,Units 1 & 2 ML20203C2811997-12-0909 December 1997 Safety Evaluation Authorizing Request for Relief of Second 10 Yr Interval Inservice Insp Program ML20202B7881997-12-0101 December 1997 Rev 8 to ISI-P-006, ISI Program for Gpc Vogtle Electric Generating Plant Unit 1 ML20203H0601997-11-30030 November 1997 Monthly Operating Repts for Nov 1997 for Vegp,Units 1 & 2 1999-09-30
[Table view] |
Text
._
t Georgia Power Cornpany ,
- 40 inverness Center Parkway
. Bdningham, Alabama 3S201 Telepnone 205 B77 7122 ,
C. K. McCoy . GeorgiaPower E$t No$eY March 9, 1993 ### ***'"
ELV-05236 7 003045 Docket Nos. 50-424 50-425 ;
Director, Office of Resource Management U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Gentlemen:
V0GTLE ELECTRIC GENERATING PLANT MONTHLY OPERATING REPORTS Enclosed are the February 1993 monthly operating reports for Vogtle Units 1 and
- 2. These reports are submitted in accordance with Technical Specification 6.8.1.5.
Sincerely, C. K. McCoy CKM/JLL/gmb /
f
Enclosures:
- 1. Monthly Operating Report - VEGP Unit 1
- 2. Monthly Operating Report - VEGP Unit 2
- 3. Challenges to PORV or Safety Valves - VEGP Units 1 and 2 l
xc: Georaia Power ComojLgy
- Mr. W. B. Shipman l Mr. M. Sheibani l NORMS U. S. Nuclear Reculatory Commission Mr. S. D. Ebneter, Regional Administrator Mr. D. S. Hood, Licensing Project Manager, NRR Mr. B. R. Bonser, Senior Resident Inspector, Vogtle
. Document Co'ntrol: Desk'd
, 9303170032 930228 t
, PDR ADOCK 05000424 '
i R PDR
. . . _ _ ~ _ . _._. . . . _ _
1 l
. i ENCLOSURE 1 l V0GTLE ELECTRIC GENERATING PLANT - UNIT 1 ;
MONTHLY OPERATING REPORT FOR FEBRUARY-1993 ,
TABLE OF CONTENTS l
NARRATIVE REPORT Page V1-1 OPERATING DATA REPORT Page VI-2 AVERAGE DAILY POWER LEVEL Page VI-3 i
UNIT SHUTDOWNS AND POWER REDUCTIONS Page VI-4 t
)
i 1
1 i
, , - . , - - . , ,, , .,,,~na__n+,. , , . , _
}
, -1 4
)_
5 NARRATIVE REPORT DOCKET NO. 50-424 l- .
MARCH 1,1993
- UNIT 1 DATE:
' COMPLETED BY:G.L HOOPER TELEPHONE: (706)8264104 l l
l . .
f ,
- FEBRUARY 01 00
- 00 UNIT 1 AT 100% POWER WITH NO OPERATIONAL PROBLEMS. -j FEBRUARY 23 01:40 UNIT 1 BEGAN COASTDOWN.
I
! FEBRUARY 28 23:59 UNIT 1 AT 93% POWER IN COASTDOWN WITH NO OPERATIONAL PROBLEMS, I $
i i
.E r
l r
i 6
i
- -i i
L f
P r
V1-1 ,
m- e ve.s ew, ww- , ~-e, --
? .
I l.
OPERATING DATA REPORT DOCKET NO. 50-424 ;
I DATE: MARCH 1,1993 COMPLETED BY: G. L. HOOPER TELEPHONE: . .('06) 826-4104 OPERATING STATUS .
- 1. UNIT NAME: VEGP UNIT 1
- 2. REPORT PERIOD: FEBRUARY 1993
- 3. LICENSED THERMAL POWER (MWt): 3411
- 4. NAMEPLATE RATING (GROSS MWe): 1215
- 5. DESIGN ELECTRICAL RATING (NET MWe): 1101 l
i 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWe): 1162
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWe): 1108
- 8. lF CHANGES OCCUR IN CAPACITY RATINGS N/A (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWe): NO RESTRICTIONS
- 10. REASONS FOR RESTRICTION,IF ANY: N/A THIS MONTH YR. TO DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD: 672 1416 50401
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL: 672.0 1416.0 43617.9 l
- 13. REACTOR RESERVE SHUTDOWN HOURS: 0.0 0.0 0.0 l 14. HOURS GENERATOR ON-LINE: 672.0 1416.0 42710.9
- 15. UNIT RESERVE SHUTDOWN HOURS
- 0.0 0.0 0.0 l
- 16. GROSS THERMAL ENERGY GENERATED (MWH): 2273143 4809873 142179276
- 17. GROSS ELEC. ENERGY GENERATED (MWH): 785300 1660180 47641165 ;
- 18. NET ELEC. ENERGY GENERATED (MWH): 752270 1590580 45231545
- 19. REACTOR SERVICE FACTOR , 100.0% 100.0% 86.5 %
- 20. REACTOR AVAILABILITY FACTOR 100.0 % 100.0 % 86.5 %
- 21. UNIT SERVICE FACTOR: 100.0 % 100.0 % 84.7 % ,
- 22. UNIT AVAILABILITY FACTOR: 100.0 % 100.0 % 84.7 %
- 33. UNIT CAPACITY FACTOR (USING MDC NET): 101.0 % 101.4 % 82.4 %
- 24. UNIT CAPACITY FACTOR (USING DER NET): 101.7 % 102.0 % 81.5 %
- 35. UNIT FORCED OUTAGE RATE: 0.0% 0.0% 6.1%
- 26. SHUTDOWNS SCHEDULED OVER THE NEXT S MONTHS (TYPE, DATE, AND DURATION OF EACH):
l REFUELING, MARCH 13,1993,41 DAYS l 27. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: N/A 1
l 8
V1-2
t
- l
. UNIT 1 AVERAGE DA!LY DOCKET NO. 50-424 ,
POWER LEVEL DATE: MARCH 1,1993 9
COMPLETED BY: G. L. HOOPER 1 TELEPHONE: (706) 826-4104 5
DAY Net MW
- 1. . . . . . . - . . . . . . . 1128
- 4. . . . . . . . . . .1131
8.......... 1130 * ,
9... 1127 * ,
10 _ . . . 1130 * ;
11.. . .... 1124
- 14 . . . . . . . . . . . . . . . 1130 * !
15= ..... 1131
- 16 . . . . . . . . . _ . . . . . 1124
- 17 . . . . . . . . . . . . . 1131
19 . .. . . . . . 1133 * ,
2 0 . . . . .... .. .. .
~
1132
- j 23 .. .. . . . . . . 1121
- 24...................... 1105' l 2 5 ... ... ..... 1094 j i
26............... 1080 !
i 27................... 1070 28 .. .. 1052
- MDC CAN BE EXCEEDED UNDER OPTIMAL CONDITIONS l
1 V1-3
. UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50424 *
~
DATE: MARCH 1,1993 UNIT NAME: VEGP UNIT 1 COMPLETED BY: G. L. HOOPER TELEPHONE: (706) 826-4104 REPORT MONTH FEBRUARY 1993 -
R M S E E Y T A T LICENSEE SC Y S H EVENT TO COMPONENT CAUSE & CORRECTIVE I P DURATION O O REPORT ED CODE ACTION TO '
NO. DATE E (HOURS) N D NUMBER ME (SUBCODE) PREVENT RECURRENCE NA NA NA NA NA NA NA NA NA NA F: FORCED REASON: METHOD: EVENTS REPORTED INVOLVE S: SCHEDULED A-EQUIPMENT FAILURE (EXPLAIN) 1 - MANUAL A GREATER THAN 20%
B-MAINTENANCE OR TEST 2- MANUAL SCRAM REDUCTION IN AVERAGE C-REFUELING 3 - AUTO. SCRAM DA!LY POWER LEVEL FOR l
D-REGULATORY RESTRICTION 4- CONTINUATIONS THE PRECEDING 24 HOURS.
E-OPERATOR TRAINING & LICENSE 5-LOAD REDUCTION F-ADMINISTRATIVE 9 - OTHER (EXPLAIN)
G-OPERATIONAL ERROR (EXPLAIN)
H-OTHER (EXPLAIN) e V1-4
4 3
ENCLOSURE 2 ,.
V0GTLE ELECTRIC GENERATING PLANT - UNIT 2 -
MONTHLY OPERATING REPORT FOR FEBRUARY 1993 TABLE OF CONTENTS i
NARRATIVE REPORT Page V2-1 !
OPERATING DATA REPORT Page V2-2 AVERAGE DAILY POWER LEVEL Page V2-3 UNIT SHUTDOWNS AND POWER REDUCTIONS Page V2-4 r
e e
P s
l l
l
'i NARRATIVE REPORT DOCKET NO. 50-425 ,
UNIT 2 DATE: MARCH 1,1'493 COMPLETED BY:G. L. HOOPER
- TELEPHONE: (706) 826-4104 i-
.. i l
l i l l
l FEBRUARY 01 00:00 UNIT 2 AT 100% POWER WITH NO OPERATIONAL PROBLEMS. -
l FEBRUARY 28 23:59 UNIT 2 AT 100% POWER WITH NO OPERATIONAL PROBLEMS.
l i
r i
6 i
V2-1 ll
OPERATING DATA REPORT DOCKET NO. 50-425 DATE: MARCH 1,1992
) COMPLETED BY: G. L. HOOPER TELEPHONE: ; ,(706) 826-4104 OPERATING STATUS
- 1. UNIT NAME: VEGP UNIT 2
- 2. REPORT PERIOD: FEBRUARY 1993
- 3. LICENSED THERMAL POWER (MWt): 3411
- 4. NAMEPLATE RATING (GROSS MWe): 1215
- 5. DESIGN ELECTRICAL RATING (NET MWe): 1101
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWe): 1161
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWe): 1107 B. IF CHANGES OCCUR IN CAPACITY RATINGS N/A i (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED,IF ANY (NET MWe): NO RESTRICTIONS
- 10. REASONS FOR RESTRICTION,IF ANY: N/A THIS MONTH YR.TO DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD: 672 1416 33145
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL: 672.0 1416.0 29661.9
- 13. REACTOR RESERVE SHUTDOWN HOURS: 0.0 0.0 0.0
- 14. HOURS GENERATOR ON-LINE: 672.0 1416.0 29203.6
- 15. UNIT RESERVE SHUTDOWN HOURS: 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH): 2291024 4827217 953155S5
- 17. GROSS ELEC. ENERGY GENERATED (MWH): 794313 1672760 32258036
- 18. NET ELEC. ENERGY GENERATED (MWH): 758993 1598280 30664856
- 19. REACTOR SERVICE FACTOR 100.0 % 100.0 % 89.5% ;
- 20. REACTOR AVAILABILITY FACTOR 100.0% 100.0 % 89.5%
- 21. UNIT SERVICE FACTOR: 100.0% 100.0% 88.1 %
- 22. UNIT AVAILABILITY FACTOR: 100.0% 100.0 % 88.1%
- 23. UNIT CAPACITY FACTOR (USING MDC NET): 102.0 % 102.0 % 84.0 %
- 24. UNIT CAPACITY FACTOR (USING DER NET): 102.6 % 102.5 % 84.0 %
- 25. UNIT FORCED OUTAGE RATE: 0.0% 0.0% 1.8%
- 26. SHUTDOWNS SCHEDULED OVER THE NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):
NONE
- 27. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: NA V2-2
UNIT 2 AVERAGE DAILY DOCKET NO. 50-425 POWER LEVEL DATE: MARCH 1,1993 COMPLETED BY: G. L. HOOPER TELEPHONE: (706) 826-4104 DAY Net MW
- 1. . 1128 *
- 2. 1132 *
- 3. 1132 *
- 4. 1132
- 6. . 1129
- 8. 1129
- 10. 1129
- 15. 1131
- 18. 1132
- 28. . . . 1131 *
- MDC CAN BE EXCEEDED UNDER OPTIM/d. CONDITIONS V2-3
- UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-425 DATE: MARCH 1,1993 UNIT NAME: VEGP UNIT 2 COMPLETED BY:G. L. HOOPER TELEPHONE: (706) 8264104 REPORT MONTH FEBRUARY 1993 R M S E E Y T A T LICENSEE SC Y S H EVENT TO COMPONENT CAUSE & CORRECTIVE P DURATION O O REPORT ED CODE ACTION TO NO. DATE E (HOURS) N D NUMBER ME (SUBCODE) PREVENT RECURRENCE NA NA NA NA NA NA NA NA NA NA 4
F: FORCED REASON: METHOD: EVENTS REPORTEDINVOLVE l S: SCHEDULED A-EQUIPMENT FAILURE (EXPLAIN) 1 - MANUAL A GREATER THAN 20%
B-MAINTENANCE OR TEST 2-MANUAL SCRAM REDUCTION IN AVERAGE C-REFUELING 3 - AUTO. SCRAM DAILY POWER LEVEL FOR -
D-REGULATORY RESTRICTION 4 - CONTINUATIONS THE PRECEDING 24 HOURS.
E-OPERATOR TRAINING & LICENSE 5-LOAD REDUCTION F-ADMINISTRATIVE 9- OTHER (EXPLAIN)
G-OPERATIONAL ERROR (EXPLAIN)
H-OTHER (EXPLAIN) 4 V24
9 O
9 9
O ENCLOSURE 3 V0GTLE ELECTRIC GENERATING PLANT - UNITS 1 AND 2 MONTHLY OPERATING REPORT FOR FEBRUARY 1993 CHALLENGES TO PORV OR SAFETY VALVES l
(ENCLOSURE 3) ,
DOCKET NOS. 50-424,50*(25 ,
VEGP UNITS 1 & 2 DATE: MARCH 1,1993 COMPLETED BY: G. L. HOOPER TELEPHONE: 9 06) 826-4104 i i
i
[
l EVENT '
DATE TAG NO. TYPE DESCRIPTION i l
NO EVENTS FOR FEBRUARY I
l 4
- - . . . _ _