Monthly Operating Repts for Feb 1993 for Vogtle Electric Generating Plant,Unit 1 & 2.W/930309 Ltr
ML20044C037
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 02/28/1993
From: Hooper G, Mccoy C
GEORGIA POWER CO.
To:
NRC
References
ELV-05236, ELV-5236, NUDOCS 9303170032
Download: ML20044C037 (13)


Text

._

t Georgia Power Cornpany ,

  • 40 inverness Center Parkway
  • l Post Office Box 1295 i

. Bdningham, Alabama 3S201 Telepnone 205 B77 7122 ,

C. K. McCoy . GeorgiaPower E$t No$eY March 9, 1993 ### ***'"

ELV-05236 7 003045 Docket Nos. 50-424 50-425  ;

Director, Office of Resource Management U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Gentlemen:

V0GTLE ELECTRIC GENERATING PLANT MONTHLY OPERATING REPORTS Enclosed are the February 1993 monthly operating reports for Vogtle Units 1 and

2. These reports are submitted in accordance with Technical Specification 6.8.1.5.

Sincerely, C. K. McCoy CKM/JLL/gmb /

f

Enclosures:

1. Monthly Operating Report - VEGP Unit 1
2. Monthly Operating Report - VEGP Unit 2
3. Challenges to PORV or Safety Valves - VEGP Units 1 and 2 l

xc: Georaia Power ComojLgy

Mr. W. B. Shipman l Mr. M. Sheibani l NORMS U. S. Nuclear Reculatory Commission Mr. S. D. Ebneter, Regional Administrator Mr. D. S. Hood, Licensing Project Manager, NRR Mr. B. R. Bonser, Senior Resident Inspector, Vogtle

. Document Co'ntrol: Desk'd

, 9303170032 930228 t

, PDR ADOCK 05000424 '

i R PDR

. . . _ _ ~ _ . _._. . . . _ _

1 l

. i ENCLOSURE 1 l V0GTLE ELECTRIC GENERATING PLANT - UNIT 1  ;

MONTHLY OPERATING REPORT FOR FEBRUARY-1993 ,

TABLE OF CONTENTS l

NARRATIVE REPORT Page V1-1 OPERATING DATA REPORT Page VI-2 AVERAGE DAILY POWER LEVEL Page VI-3 i

UNIT SHUTDOWNS AND POWER REDUCTIONS Page VI-4 t

)

i 1

1 i

, , - . , - - . , ,, , .,,,~na__n+,. , , . , _

}

, -1 4

)_

5 NARRATIVE REPORT DOCKET NO. 50-424 l- .

MARCH 1,1993

UNIT 1 DATE:

' COMPLETED BY:G.L HOOPER TELEPHONE: (706)8264104 l l

l . .

f ,

FEBRUARY 01 00
00 UNIT 1 AT 100% POWER WITH NO OPERATIONAL PROBLEMS. -j FEBRUARY 23 01:40 UNIT 1 BEGAN COASTDOWN.

I

! FEBRUARY 28 23:59 UNIT 1 AT 93% POWER IN COASTDOWN WITH NO OPERATIONAL PROBLEMS, I $

i i

.E r

l r

i 6

i

-i i

L f

P r

V1-1 ,

m- e ve.s ew, ww- , ~-e, --

? .

I l.

OPERATING DATA REPORT DOCKET NO. 50-424  ;

I DATE: MARCH 1,1993 COMPLETED BY: G. L. HOOPER TELEPHONE: . .('06) 826-4104 OPERATING STATUS .

1. UNIT NAME: VEGP UNIT 1
2. REPORT PERIOD: FEBRUARY 1993
3. LICENSED THERMAL POWER (MWt): 3411
4. NAMEPLATE RATING (GROSS MWe): 1215
5. DESIGN ELECTRICAL RATING (NET MWe): 1101 l

i 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWe): 1162

7. MAXIMUM DEPENDABLE CAPACITY (NET MWe): 1108
8. lF CHANGES OCCUR IN CAPACITY RATINGS N/A (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWe): NO RESTRICTIONS
10. REASONS FOR RESTRICTION,IF ANY: N/A THIS MONTH YR. TO DATE CUMULATIVE
11. HOURS IN REPORTING PERIOD: 672 1416 50401
12. NUMBER OF HOURS REACTOR WAS CRITICAL: 672.0 1416.0 43617.9 l
13. REACTOR RESERVE SHUTDOWN HOURS: 0.0 0.0 0.0 l 14. HOURS GENERATOR ON-LINE: 672.0 1416.0 42710.9
15. UNIT RESERVE SHUTDOWN HOURS
0.0 0.0 0.0 l
16. GROSS THERMAL ENERGY GENERATED (MWH): 2273143 4809873 142179276
17. GROSS ELEC. ENERGY GENERATED (MWH): 785300 1660180 47641165  ;
18. NET ELEC. ENERGY GENERATED (MWH): 752270 1590580 45231545
19. REACTOR SERVICE FACTOR , 100.0% 100.0% 86.5 %
20. REACTOR AVAILABILITY FACTOR 100.0 % 100.0 % 86.5 %
21. UNIT SERVICE FACTOR: 100.0 % 100.0 % 84.7 % ,
22. UNIT AVAILABILITY FACTOR: 100.0 % 100.0 % 84.7 %
33. UNIT CAPACITY FACTOR (USING MDC NET): 101.0 % 101.4 % 82.4 %
24. UNIT CAPACITY FACTOR (USING DER NET): 101.7 % 102.0 % 81.5 %
35. UNIT FORCED OUTAGE RATE: 0.0% 0.0% 6.1%
26. SHUTDOWNS SCHEDULED OVER THE NEXT S MONTHS (TYPE, DATE, AND DURATION OF EACH):

l REFUELING, MARCH 13,1993,41 DAYS l 27. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: N/A 1

l 8

V1-2

t

l

. UNIT 1 AVERAGE DA!LY DOCKET NO. 50-424 ,

POWER LEVEL DATE: MARCH 1,1993 9

COMPLETED BY: G. L. HOOPER 1 TELEPHONE: (706) 826-4104 5

DAY Net MW

1. . . . . . . - . . . . . . . 1128
  • 2 .. ... 1132
  • 3 .. ....... 1133
  • I
4. . . . . . . . . . .1131
  • 5.................. 1130
  • 6................ 1129
  • 7 . . .. . 1129 *  !

8.......... 1130 * ,

9... 1127 * ,

10 _ . . . 1130 *  ;

11.. . .... 1124

  • 12 . . . . . . . . 1119
  • 13 - . .. 1127
  • 14 . . . . . . . . . . . . . . . 1130 *  !

15= ..... 1131

  • 16 . . . . . . . . . _ . . . . . 1124
  • 17 . . . . . . . . . . . . . 1131
  • 18 . 1128 * ,

19 . .. . . . . . 1133 * ,

2 0 . . . . .... .. .. .

~

1132

  • 21................. 1123
  • 22................. 1122
  • j 23 .. .. . . . . . . 1121
  • 24...................... 1105' l 2 5 ... ... ..... 1094 j i

26............... 1080  !

i 27................... 1070 28 .. .. 1052

  • MDC CAN BE EXCEEDED UNDER OPTIMAL CONDITIONS l

1 V1-3

. UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50424 *

~

DATE: MARCH 1,1993 UNIT NAME: VEGP UNIT 1 COMPLETED BY: G. L. HOOPER TELEPHONE: (706) 826-4104 REPORT MONTH FEBRUARY 1993 -

R M S E E Y T A T LICENSEE SC Y S H EVENT TO COMPONENT CAUSE & CORRECTIVE I P DURATION O O REPORT ED CODE ACTION TO '

NO. DATE E (HOURS) N D NUMBER ME (SUBCODE) PREVENT RECURRENCE NA NA NA NA NA NA NA NA NA NA F: FORCED REASON: METHOD: EVENTS REPORTED INVOLVE S: SCHEDULED A-EQUIPMENT FAILURE (EXPLAIN) 1 - MANUAL A GREATER THAN 20%

B-MAINTENANCE OR TEST 2- MANUAL SCRAM REDUCTION IN AVERAGE C-REFUELING 3 - AUTO. SCRAM DA!LY POWER LEVEL FOR l

D-REGULATORY RESTRICTION 4- CONTINUATIONS THE PRECEDING 24 HOURS.

E-OPERATOR TRAINING & LICENSE 5-LOAD REDUCTION F-ADMINISTRATIVE 9 - OTHER (EXPLAIN)

G-OPERATIONAL ERROR (EXPLAIN)

H-OTHER (EXPLAIN) e V1-4

4 3

ENCLOSURE 2 ,.

V0GTLE ELECTRIC GENERATING PLANT - UNIT 2 -

MONTHLY OPERATING REPORT FOR FEBRUARY 1993 TABLE OF CONTENTS i

NARRATIVE REPORT Page V2-1  !

OPERATING DATA REPORT Page V2-2 AVERAGE DAILY POWER LEVEL Page V2-3 UNIT SHUTDOWNS AND POWER REDUCTIONS Page V2-4 r

e e

P s

l l

l

'i NARRATIVE REPORT DOCKET NO. 50-425 ,

UNIT 2 DATE: MARCH 1,1'493 COMPLETED BY:G. L. HOOPER

  • TELEPHONE: (706) 826-4104 i-

.. i l

l i l l

l FEBRUARY 01 00:00 UNIT 2 AT 100% POWER WITH NO OPERATIONAL PROBLEMS. -

l FEBRUARY 28 23:59 UNIT 2 AT 100% POWER WITH NO OPERATIONAL PROBLEMS.

l i

r i

6 i

V2-1 ll

OPERATING DATA REPORT DOCKET NO. 50-425 DATE: MARCH 1,1992

) COMPLETED BY: G. L. HOOPER TELEPHONE: ; ,(706) 826-4104 OPERATING STATUS

1. UNIT NAME: VEGP UNIT 2
2. REPORT PERIOD: FEBRUARY 1993
3. LICENSED THERMAL POWER (MWt): 3411
4. NAMEPLATE RATING (GROSS MWe): 1215
5. DESIGN ELECTRICAL RATING (NET MWe): 1101
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWe): 1161
7. MAXIMUM DEPENDABLE CAPACITY (NET MWe): 1107 B. IF CHANGES OCCUR IN CAPACITY RATINGS N/A i (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
9. POWER LEVEL TO WHICH RESTRICTED,IF ANY (NET MWe): NO RESTRICTIONS
10. REASONS FOR RESTRICTION,IF ANY: N/A THIS MONTH YR.TO DATE CUMULATIVE
11. HOURS IN REPORTING PERIOD: 672 1416 33145
12. NUMBER OF HOURS REACTOR WAS CRITICAL: 672.0 1416.0 29661.9
13. REACTOR RESERVE SHUTDOWN HOURS: 0.0 0.0 0.0
14. HOURS GENERATOR ON-LINE: 672.0 1416.0 29203.6
15. UNIT RESERVE SHUTDOWN HOURS: 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH): 2291024 4827217 953155S5
17. GROSS ELEC. ENERGY GENERATED (MWH): 794313 1672760 32258036
18. NET ELEC. ENERGY GENERATED (MWH): 758993 1598280 30664856
19. REACTOR SERVICE FACTOR 100.0 % 100.0 % 89.5%  ;
20. REACTOR AVAILABILITY FACTOR 100.0% 100.0 % 89.5%
21. UNIT SERVICE FACTOR: 100.0% 100.0% 88.1 %
22. UNIT AVAILABILITY FACTOR: 100.0% 100.0 % 88.1%
23. UNIT CAPACITY FACTOR (USING MDC NET): 102.0 % 102.0 % 84.0 %
24. UNIT CAPACITY FACTOR (USING DER NET): 102.6 % 102.5 % 84.0 %
25. UNIT FORCED OUTAGE RATE: 0.0% 0.0% 1.8%
26. SHUTDOWNS SCHEDULED OVER THE NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):

NONE

27. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: NA V2-2

UNIT 2 AVERAGE DAILY DOCKET NO. 50-425 POWER LEVEL DATE: MARCH 1,1993 COMPLETED BY: G. L. HOOPER TELEPHONE: (706) 826-4104 DAY Net MW

1. . 1128 *
2. 1132 *
3. 1132 *
4. 1132
  • 5= 1131 *
6. . 1129
  • 7 1130*
8. 1129
  • 9 1128 *
10. 1129
  • 11 . 1125
  • 12 . 1125
  • 13 . 1128
  • 14 . . 1131 *
15. 1131
  • 16 . 1125
  • 17 . 1130 *
18. 1132
  • 19 . 1132
  • 20 . 1132
  • 21 . 1125
  • 22 . 1124
  • 23 . . 1129
  • 24 . . 1131
  • 25 . 1132
  • 26 . 1131
  • 27 . 1131*
28. . . . 1131 *
  • MDC CAN BE EXCEEDED UNDER OPTIM/d. CONDITIONS V2-3
  • UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-425 DATE: MARCH 1,1993 UNIT NAME: VEGP UNIT 2 COMPLETED BY:G. L. HOOPER TELEPHONE: (706) 8264104 REPORT MONTH FEBRUARY 1993 R M S E E Y T A T LICENSEE SC Y S H EVENT TO COMPONENT CAUSE & CORRECTIVE P DURATION O O REPORT ED CODE ACTION TO NO. DATE E (HOURS) N D NUMBER ME (SUBCODE) PREVENT RECURRENCE NA NA NA NA NA NA NA NA NA NA 4

F: FORCED REASON: METHOD: EVENTS REPORTEDINVOLVE l S: SCHEDULED A-EQUIPMENT FAILURE (EXPLAIN) 1 - MANUAL A GREATER THAN 20%

B-MAINTENANCE OR TEST 2-MANUAL SCRAM REDUCTION IN AVERAGE C-REFUELING 3 - AUTO. SCRAM DAILY POWER LEVEL FOR -

D-REGULATORY RESTRICTION 4 - CONTINUATIONS THE PRECEDING 24 HOURS.

E-OPERATOR TRAINING & LICENSE 5-LOAD REDUCTION F-ADMINISTRATIVE 9- OTHER (EXPLAIN)

G-OPERATIONAL ERROR (EXPLAIN)

H-OTHER (EXPLAIN) 4 V24

9 O

9 9

O ENCLOSURE 3 V0GTLE ELECTRIC GENERATING PLANT - UNITS 1 AND 2 MONTHLY OPERATING REPORT FOR FEBRUARY 1993 CHALLENGES TO PORV OR SAFETY VALVES l

(ENCLOSURE 3) ,

DOCKET NOS. 50-424,50*(25 ,

VEGP UNITS 1 & 2 DATE: MARCH 1,1993 COMPLETED BY: G. L. HOOPER TELEPHONE: 9 06) 826-4104 i i

i

[

l EVENT '

DATE TAG NO. TYPE DESCRIPTION i l

NO EVENTS FOR FEBRUARY I

l 4

- - . . . _ _