ML20086F42616 June 1977Environ RO 77-14:on 770606 & 08,ph for Settling Basin Effluent Exceeded ETS Limit.Cause Not Identified.Settling Basin Isolated & Neutralized.Ph Checked & Sys Returned to Normal OperationGrab sample
ML20086F47027 January 1976Ro:On 760117,gaseous Activity Release Rate Exceeded 4% of Tech Spec 3.8.C.1 for More than 48 H.Caused by Increase in Offgas Activity Due to Fuel Cladding PerforationsFuel cladding
Power change
ML20086F47323 December 1975Ro:On 751123,during Insp of Upper Portions of Drywell,Two of Eight Reactor Vessel Stabilizers Appeared to Have Been Slightly Deformed.Caused by Stabilizer Bindup & Cyclic Loading During Vessel Heatup or Cooldown
ML20086F81525 February 1977Environ RO 77-8:on 770217,total Suspended Solids for Sewage Plant Effluent Exceeded ETS Limit.Caused by Sys Upset Brought About by Reduced Bacterial Action within Activated Sludge Aeration Tank
ML20086F81818 February 1977Environ RO 77-6:on 770208,total Suspended Solids for Sewage Plant Effluent Exceeded ETS Limit.Caused by High Flow Carrying Solids Over from Aeration Tank.Chlorine Contact Tank Cleaned & Solids Removed
ML20086F82628 January 1977Environ RO 77-4:on 770118,total Suspended Solids for Sewage Plant Effluent Exceeded Environ Tech Spec Limit.Caused by High Flow Period Carrying Solids Over Aeration Tank Into Chlorine Contact Tank
ML20086F82827 January 1977Environ RO 77-3:on 770117,pH for Sewage Plant Effluent Exceeded ETS Limit.Caused by Influent W/Ph Slightly Lower than Normal.Sewage Plant Neutralized & Returned to Normal Operation
ML20086F82919 January 1977Environ 77-2:on 770109,total Suspended Solids for Settling Basin Effluent Exceeded ETS Limit.Caused by Excessive Flow Combined W/Solids from Clarifier.Settling Basin Isolated & Pumped Out to Reduce Solid Inventory
ML20086F83017 January 1977Environ RO 77-1:on 770107,total Suspended Solids for Sewage Plant Effluent Exceeded ETS Limit.Caused by High Flow Carrying Solids Over from Aeration Tank Into Chlorine Contact Tank & Info Effluent
ML20086F83326 October 1976Environ 76-41:on 761016,total Suspended Solids for Settling Basin Effluent Exceeded ETS Limit.Caused by Excessive Flow Combined W/Abnormal Solid Input from River Water.Settling Basin Isolated & Pumped Out
ML20086F8358 October 1976Environ RO 76-40:on 761001,pH for Settling Basin Effluent Exceeded ETS Limits.Caused by Neutralizing Tank B Overflowing Into Neutralizing Tank A.Settling Basin Isolated & NeutralizedGrab sample
ML20086G0908 October 1976Environ RO 76-39:on 760929,pH for Settling Basin Effluent Exceeded ETS Limit.Caused by Soda Ash Solution Mix Tank Overflowing Into Raw Water Sump When Suction Line Plugged. Settling Basin Isolated & NeutralizedGrab sample
ML20086G0981 October 1976Environ RO 76-38:on 760922,pH for Settling Basin Effluent Exceeded ETS Limit.Cause Not Determined.Settling Basin Isolated & Neutralized.Ph Checked & Normal Operation ResumedGrab sample
ML20086G10127 September 1976Environ RO 76-37:on 760917,total Suspended Solids for Sewage Plant Effluent Exceeded ETS Limit.Caused by High Flow Carrying Solids Over from Aeration Tank Into Chlorine Contact Tank & Effluent
ML20086G10424 September 1976Environ RO 76-36:on 760915,pH for Sewage Plant Effluent Exceeded ETS Limit.Caused by Cleaning Solution Containing 30% Hydrochloric Acid Flushed Into Sewage Plant.Sewage Plant Neutralized & Instructions IssuedGrab sample
ML20086G10623 September 1976Environ RO 76-35:on 760913,pH for Settling Basin Effluent Exceeded ETS Limit.Caused by Valving Error During Regeneration of Cation Demineralizer.Valving Error Found & Corrected & Basin Isolated & NeutralizedGrab sample
ML20086G1083 September 1976Environ RO 76-34:on 760827,total Suspended Solids for Sewage Plant Effluent Exceeded ETS Limit.Caused by High Flow That Carried Solids from Aeration Tank Into Chlorine Contact Tank & Effluent.Tank CleanedTemporary Modification
ML20086G11023 August 1976Environ RO 76-33:on 760813,pH for Settling Basin Effluent Exceeded ETS Limit.Caused by Alum Feeder to Clarifier Overflowing to Raw Water Sump.Settling Basin Isolated & Raw Water Sump Pump StoppedGrab sample
ML20086G11423 August 1976Environ RO 76-32:on 760811,pH for Settling Basin Effluent Exceeded ETS Limit.Caused by Faulty Ph Meter on Neutralizing Tank Discharge to Settling Basin.Settling Basin Isolated & Neutralized
ML20086G12313 August 1976Environ RO 76-31:on 760804,pH for Settling Basin Effluent Exceeded Range Allowable by Ets.Caused by Faulty Ph Meter on Neutralizing Tank Discharge to Settling Basin.Settling Basin Isolated & NeutralizedGrab sample
ML20086G13616 July 1976Environ RO 76-30:on 760707,pH for Settling Basin Effluent Exceeded Range Allowable by Ets.Cause Unknown.Memo Clearly Describing Proper Action During Clarifier Malfunction Sent to Operators & SupervisorsGrab sample
ML20086G14318 June 1976Environ RO 76-29:on 760610,radioactivity in Critical Pathway Exceeded Tech Spec Limit.Caused by Presence of I-131.Surveillance of Roof Vent Iodine Release Rate Increased & Visual Insp & Air Sampling Program Initiated
ML20086G15817 June 1976Environ RO 76-28:on 760607,sewage Plant Effluent Suspended Solids Exceeded ETS Limit.Caused by Inoperability of Sludge Return Pump.Sludge Removed from Chlorine Contact Tank & Return Pump Returned to Svc
ML20086G16917 May 1976Environ RO 76-27:on 760507,three Cooling Towers Became Simultaneously Inoperable.Caused by Bolts Holding Impeller Housing to Pump Diffuser Section Failing.Investigation Continuing to Determine Corrective Action
ML20086G19414 May 1976Environ RO 76-26:on 760505,sewage Plant Effluent Suspended Solids Exceeded ETS Limit.Caused by Inoperability of Sludge Return Pump.Obstruction in Pump Removed & Sludge Removed from Settling Zone
ML20086G21314 May 1976Environ RO 76-25:on 760504,three Cooling Towers Became Simultaneously Inoperable.Caused by Tower Lift Pump C Inadvertently Tripping During Bus Switching.Lubricating Water Lines Flushed & Lift Pump C & Tower Returned to Svc
ML20086G23712 May 1976Environ RO 76-24:on 760502,two Cooling Towers Became Simultaneously Inoperable.Caused by Failure of Bolts Holding Suction Bell Housing to Pump Casing.Investigation Continuing to Determine Course of Action
ML20086G2417 May 1976Environ RO 76-23:on 760429,two Cooling Towers Became Simultaneously Inoperable.Caused by Shaft Line Bearing Housing Thrown Free & Falling Through Structure.Tower C Returned to SvcScaffolding
ML20086G2437 May 1976Environ RO 76-22:on 760428,two Cooling Towers Became Simultaneously Inoperable.Caused by Accumulation of Silt in Lubricating Water Lines.Lines Flushed & Lift Pump C & Cooling Tower Returned to Svc
ML20086G24529 April 1976Environ RO 76-21:on 760419,two Cooling Towers Became Simultaneously Inoperable.Caused by Broken Gear Reducer Bracket Resulting in Fan Trip Due to High Vibration.Fans E&F Returned to Svc
ML20086G24819 November 1975AO 75-72:on 751109,crack in 3/4-inch Vent Line on RHR Piping Observed.Caused by Throttle of MO-2-10-1548 Valve Resulting in Crack.Repairs Completed in Accordance W/Approved Procedures
ML20086G2505 March 1976Environ RO 76-14:on 760224,three Cooling Towers Became Simultaneously Inoperative.Caused by Mechanical Failure. Valve Repaired & Tower Returned to Svc
ML20086G2535 March 1976Environ RO 76-13:on 760224,two Cooling Towers Simultaneously Inoperable.Caused by Mechanical Failure.Leaking Section of Distribution Header Repaired
ML20086G25612 April 1976Environ RO 76-19:on 760402,two Cooling Towers Became Simultaneously Inoperable.Caused by Worn Motor Bearings & Seized Line Bearing Box.Fan L Returned to Svc,Restoring Cooling Tower to Operable Status
ML20086G25824 March 1976Environ RO 76-17:on 760314,two Cooling Towers Become Simultaneously Inoperable.Caused by Plugging of Lubricating Water Lines.Lubricating Water Lines Flushed.Investigation Continuing
ML20086G25930 January 1976Environ RO 76-6:on 760120,sewage Plant Effluent Suspended Solids Exceeded ETS Limit.Caused by Solids Carried Over from Settling Zone Into Chlorine Contact Zone & Effluent.Sludge Return Line Blown Back W/Svc Air
ML20086G26223 January 1976Environ RO 76-5:on 760114,settling Basin Ph Exceeded ETS Limit.Caused by Neutralizing Tank Discharging Into Settling Basin W/O Being Neutralized Due to Improper Valving Lineup. Settling Basin Isolated & Neutralized
ML20086G26519 January 1976Environ RO 76-3:on 760109,Unit 2 Operated Above 20% Power W/All Cooling Towers Inoperable.Caused by Cooling Water Intake Temp Too Low to Facilitate Tower Startup W/O Causing Damage.No Corrective Action Required
ML20086G26715 January 1976Environ RO 76-1:on 760105,two Cooling Towers Became Simultaneously Inoperative.Caused by Worn Motor Bearings on Fans K & E.Failure of Fan L Under Investigation.Motor to Fan K Replaced & Repairs to Fan E in Progress
ML20086G2813 October 1975Environ RO 75-20:on 750923,second Fan on Cooling Tower C Lost.Caused by Failed Coupling.Fan F Motor Replaced & Balanced.Awaiting Parts for Repair of Fan D
ML20086G30828 February 1976Environ RO 76-11:on 760218,settling Basin Effluent Suspended Solids Concentration Exceeded Environ Tech Spec Limit.Caused by High Suspended Solids Level in River Water.Settling Basin Contents Settled & Solids Pumped Out
ML20086G31323 January 1976Environ RO 76-5:on 760114,settling Basin Effluent Ph Exceeded Environ Tech Spec Limit.Caused by Neutralizing Tank Discharged to Settling Basin W/O Being Neutralized Due to Improper Valving Lineup.Basin Isolated & Neutralized
ML20086G31522 January 1976Environ RO 76-4:on 760112,sewage Plant Effluent Suspended Solids Exceeded Environ Tech Spec Limit.Caused by Solids Carried Over from Settling Zone Into Chlorine Contact Tank. Chlorine Contact Tank Pumped Out
ML20086G33619 January 1976Environ RO 76-3:on 760109,Unit 2 Operated Above 20% Power W/All Cooling Towers Inoperable.Caused by Cooling Water Intake Temp Too Low to Facilitate Tower Startup W/O Causing Damage.No Corrective Action Required
ML20086G34415 January 1976Environ RO 76-2:on 760105,sewage Plant Effluent Suspended Solids in Excess of Environ Tech Spec Limit.Caused by Inadequate Sludge Return.Chlorine Contact Tank Pumped Out & Sludge Return Line Cleaned
ML20086G35326 November 1975Environ RO 75-26:on 751116,two Towers Simultaneously Inoperable.Caused by Failure of Lubricating Water Pump Motor Bearings.Lubricating Water Pump Motor Bearings Replaced
ML20086G3557 November 1975Environ RO 75-25:on 751030,sewage Plant Effluent Suspended Solids Exceeded Environ Tech Spec Limit.Caused by Plugged Sludge Return Pump.Sludge Pump Cleared & Returned to Svc
ML20086G35729 October 1975RO 75-24:on 751019,all Cooling Towers Removed from Svc. Caused by High Mud Content in River Water.After Mud Content in River Decreased,Cooling Tower a Returned to Svc. Corrective Maint Performed on Cooling Tower C
ML20086G36524 October 1975RO 75-23:on 751015,cooling Tower C Removed from Svc for Maint.Caused by Excessive Nitrogen Leakage from Fire Detection Sys.Accessable Connections on Nitrogen Piping Repaired
ML20086G36810 October 1975Environ RO 75-22:on 750930,second Fan on Cooling Tower C Failed.Caused by Gear Reducer Pinion Shaft Bearings Failure Resulting in Trip Due to High Vibration.Fan Repaired & Returned to Svc