Forwards Info Requested at 860923 SALP I Meeting,Including Clarification of Apps Listed in Table in Ref to 10CFR50 & Listing of Subjs of Amends 111-117 to License DPR-50
ML20210U443
Person / Time
Site: Three Mile Island Constellation icon.png
Issue date: 10/02/1986
From: Blough A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Corradi J
AFFILIATION NOT ASSIGNED
References
NUDOCS 8610090521
Download: ML20210U443 (3)


Text

i e-

~.

OCT 2 1986 Docket No. 50-289 Ms. Joyce Corradi 2 South Nissley Drive Middletown, Pennsylvania 17057

Dear Ms. Corradi:

Attached is the information that you requested at the "SALP I" public meeting of September 23, 1986, in reference to Systematic Assessment of Licensee Per-formance Table 7-1. Also, for clarification and as mentioned at the meeting, the " appendices" listed in that table are in reference to appendices of NRC Code of Federal Regulation 10 CFR 50. They are not appendices of the SALP report. I will try to make the table more useful and understandable in the next SALP report.

If you have any additional questions on this matter, please contact either Richard Conte (717-948-1167) or me (215-337-5146).

Sincerely, P

Original Signed By:

Allen R. Blough, Chief Reactor Projects Section 1A

Attachment:

As Stated cc: POR LPDR f RI:DRP RI:DRP 70e Conte Bo h

/o G

- Si l$ ^/ /CG

/- s 0FFICIAL RECORD COPY 374BLOUGH9/29/86 - 0001.0.0 10/01/86 IF//0 goo 0521 861002 I G DOCK 05000289 PDR ,

1 1

ATTACHMENT LICENS(_AMENDMENTSISSUED SALP TABLE 7 Amendment No. Subject 111 This amendment adds Technical Specifications (TS) on new fire detection instruments which were installed by the licensee.

112 This amendment adds the positions titled " Manager (s), Plant Engineering" which report to the Plant Engineering Director, and limits the number of managers in these positions to six. In addition, the amendment changes the " Chemistry Supervisor" block title to " Staff Chemist."

113 This amendment modifies Section 4.4.1.2.5 of the TMI-I Technical Specifications to state that local leak. rate detection tests shall be performed at a frequency as required by 10 CFR 50, Appendix J. The amendment also states that if an exemption from the test frequency as specified by 10 CFR 50, Appendix J is granted by the NRC, the frequency, as specified by the exemption, shall apply.

114 This amendment modifies the TS to allow defeating of two automatic reactor trips during low power physics testing. The specific reactor trips involved are the anticipatory reactor trips for main feedwater pump trip and main turbine trip.

115 This amendment modifies TS 3.13, Secondary Coolant System Activity, by (1) decreasing the specificaticn for I-131 activity from 1.0 uCi/cc to 0.1 uC1/ gram DOSE EQUIVALENT I-131, (2) describing actions to be taken if the limit is exceeded, (3) eliminating the weekly gross activity determination in favor of isotopic analysis for DOSE EQUIVALENT I-131 once per every seventy-two hours, and (4) deleting the requirement to determine the I-131 condenser partition factor if primary to secondary leakage develops. ,e 116 This amendment revises the repair limits for the steam generator tubes under a restrictive set of circumstances. The amendment is also only effective

4 f

i 2 until the next refueling outage at which time the steam generator tube repair criteria will be re-evaluated.

I

)

N