IR 05000298/1998009

From kanterella
Jump to navigation Jump to search
Refers to Insp Rept 50-298/98-09 Conducted Between 981227-990130.During Insp,Apparent Violation of 10CFR50.50 Identified & Being Treated as non-cited
ML20206R983
Person / Time
Site: Cooper, Crane 
Issue date: 05/12/1999
From: Crlenjak R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Langenbach J
GENERAL PUBLIC UTILITIES CORP.
References
50-298-98-09, 50-298-98-9, EA-98-432, NUDOCS 9905210023
Download: ML20206R983 (3)


Text

SUBJECT:

NON-CITED VIOLATION - NRC INSPECTION REPORT NO. 50-289/98-09

Dear Mr. Langenbach:

This letter refers to the subject inspection conducted between December 27,1998, and January 30,1999, at the Three Mile Island Nuclear Station in Middletown Pennsylvania. We discussed

.the findings with members of your staff on February 12,1999, and forwarded the subject report to you on March 5,1999. During the inspection we identified an apparent violation of 10 CFR 50.59 related to changes you made in November 1997 to the loss of feedwater (LOFW) accident analysis and emergency feedwater (EFW) system testing acceptance criteria used to ensure system capability to meet the analysis requirements. We found that you lowered the minimum required EFW flowrate through the new LOFW analysis from 500 gpm to 480 gpm. Further, you made this change without conducting an evaluation to determine that it did not involve an unreviewed safety question (USQ). We questioned whether this reduction in flow changed the design basis of the EFW system with respect to the ability of the turbine driven pump to supply 100 percent of the required flow, as discussed in the TS bases. If the safety margin were reduced,10 CFR 50.59 would require that you obtain prior NRC approval through a license amendment prior to implementing the lower flow rate. On April 23,1999, we conducted a predecisional enforcement conference with you and members of your staff to discuss the k

apparent violation, its causes, and your corrective actions.

The NRC staff has determined that the reduction in the LOFW accident EFW flowrate requirement from 500 gpm to 480 gpm did not involve a USQ and therefore did not require NRC review prior to implementation. We based this determination on a review of the information you provided at the conference, and NRC and GPUN documentation from 1979 through 1986.

Specifically, your restart report and letter dated April 29,1985, provided information indicating that the turbine driven pump was never credited as 100 percent capacity for the design basis LOFW accident and that, following the 6R refueling outage, the system was single failure proof, allowing any two of the three EFW pumps to supply the required LOFW flow. Therefore, the change did not reduce the margin of safety defined in the TS bases.

However, we did find that you failed to conduct a safety evaluation as required by 10 CFR 50.59 prior to implementing changes to LOFW calculations and EFW testing acceptance criteria.

Further, we note that you have documented this NRC identified, non-willful failure to conduct h '.O '

9905210023 990512 i

PDR ADOCK 05000289

G PM j

i

]

.

.

.

Mr. this safety evaluation in your corrective action program under CAP 1999-0311, dated April 2, 1999. There was low safety consequence to the issue, as we noted in inspection Report 50-298/98-03, in that your testing demonstrated that the EFW system could provide necessary LOFW flow with any two of the three pumps and no operability questions existed.

In accordance with the " General Statement of Policy and Procedure for NRC Enforcement Actions" ( Enforcement Policy,) NUREG-1600, we determined that a Severity Level IV violation of NRC requirements occurred. This violation is being treated as a Non-Cited Violation (NCV),

consistent with Appendix C of the Enforcement Policy. The NCV is described above and in the subject inspection report. If you contest the violation or severity level of the NCV, you should provide a response within 30 days of the date of this letter, with the basis for your denial, to the Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001; with a copies to the Regional Administrator, Region 1; the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001; and the NRC Resident inspector at the TMl facility.

.!

Further, at the conference you acknowledged that the UFSAR and TS bases were unclear relative to how the EFW system met the design basis flow and pump capability requirements.

This letter confirms your commitments made at the conference to rewrite the EFW TS bases and system description in UFSAR Chapter 10, and to provide training to clarify the intent that any two of the three installed pumps have the capability to supply either or both OTSGs with water at greater than the total flow requirements as defined in your UFSAR Chapter 14 LOFW analysis.

In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter and any subsequent response from you will be placed in the NRC Public Document Room.

Sincerely, Original Signed By:

Richard V. Crienjak, Deputy Director Division of Reactor Projects

,

Docket Nos.: 50-289; 50-320 cc w/ encl:

M. J. Ross, Director, Operations and Maintenance D. Smith, PDMS Manager M. Laggart, Manager, Licensing and Vendor Audits J. Wetmore, Manager, Nuclear Safety and Licensing

=

E. L. Blake, Shaw, Pittman, Potts and Trowbridge (Legal Counsel for GPUN)

TMI-Alert (TMIA)

Commonwealth of Pennsylvania

)

Mr. Distribution w/ encl:

Region l Docket Room (with concurrences)

Nuclear Safety information Center (NSIC)

PUBLIC NRC Resident inspector H. Miller, RA/J. Wiggins, DRA P. Eselgroth, DRP N. Perry, DRP C. O'Daniell, DRP D. Holody, EO, RI T. Walker, ORA Distribution w/enci(VIA E-MAIL):

M. Tschiltz, OEDO E. Adensam, PD1, NRR T. Colburn, PD1, NRR H. Pastis, PD1, NRR S. Weiss, NRR L. Thonus, NRR R. Correia, NRR G. Hubbard, NRR W. Kane, NRR B. Sheron, NRR D. Dambly, OGC J. Lieberman, OE D. Holody, EO, RI T. Walker, ORA, RI DOCDESK Inspection Program Branch, NRR (IPAS)

DOCUMENT NAME: G:\\ BRANCH 7\\TMi\\TMINCV.WPD i

Ta receive a copy cef this document. Indicate in the box: "c" = Co n without attachment / enclosure

"E" = Cop 9 with attachment / enclosure

"N" = No copy

)

OFFICE Rl/DRP L/

Rl/DRf lC/Rl/ORM NRR/DSSA [/ NRR/PD1 l

Rl/DRP/L l NAME WSchmidt#/y7s Pl5lp$oth TWalkdr'

GHubbard#F EAdensam3 RCrlenSkG

'

DATE 05/11/99 05/II /99 05/ /l/99 05////99 m/L 05/IS/99 j'

05//2/99 OFFICIAL RECORD COPY c c.,drreA by fW'

(sA{t>

y$