ML20210K769
ML20210K769 | |
Person / Time | |
---|---|
Site: | 07000754 |
Issue date: | 04/25/1986 |
From: | Jonathan Montgomery NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
To: | Darmitzel R GENERAL ELECTRIC CO. |
Shared Package | |
ML20210K774 | List: |
References | |
NUDOCS 8604290050 | |
Download: ML20210K769 (1) | |
Similar Documents at 07000754 | |
---|---|
Category:CORRESPONDENCE-LETTERS
MONTHYEARML20212L9931999-10-0505 October 1999
[Table view]Forwards Fr Notice,Notice of Public Meeting & Agenda for Public Informational Meeting to Be Held on 991020 Re Safety of Periodic Shipments of Irradiated Nuclear Fuel for Post Irradiation Exam at GE Vallecitos Site ML20217F2071999-09-29029 September 1999 Provides Follow Up to Earlier Ltr Requesting Public Mtg to Hear from County Health Officials & Residents About Plan to Ship Spent Nuclear Fuel Rods Through Alameda County to GE Vallecitos Nuclear Center Near Pleasanton ML20211N7391999-09-0101 September 1999 Forwards Replacement Pages to Appendices to SNM-960, Submitted in Response to Rai,Dtd 990726.Editing Line in right-hand Margin of Revised Pages Indicates Changes ML20210T8531999-08-12012 August 1999 Forwards Notice to Fr Concerning GE-Vallecitos Nuclear Center Application for Renewal of License SNM-960 & Solicitation for Public Meeting If Needed ML20210E9361999-07-26026 July 1999 Informs That Staff Review of 990121 Application Requesting Renewal of License SNM-690,has Identified Addl Info Needed. Info Specified in Encl Should Be Provided within Thirty Days of Ltr ML20205Q4351999-04-15015 April 1999 Approves Route Described in Re Transport of Spent Fuel from Dundalk Marine Terminal Baltimore,Md,To Vallecitos Nuclear Ctr,Pleasant,Ca ML20204J2411999-03-24024 March 1999 Ack Receipt of Application for Renewal of License SNM-960, Transmitted by .Staff Has Conducted Preliminary Review of Renewal Application & Accepted Application for Formal Review.Review Schedule Will Be Provided in Future ML20210U0401999-02-0202 February 1999 Forwards Info Requesting Route Approval in Accordance with 10CFR73,for Shipment of Irradiated Test Fuel Rods ML20202G1091999-01-28028 January 1999 Submits Response to NRC Re Upcoming Licensing Actions Through Fiscal Yr 2000 ML20203B3901999-01-27027 January 1999 Forwards Amend 2 to License SNM-960,updating Technical, Organizational & Environ Action Level Changes.Safety License Condition Has Been Revised to Include Dates of 980709 & 1120.Safety Evaluation Rept Also Encl ML20198S8981999-01-0404 January 1999 Forwards Insp Rept 70-0754/98-02 on 981116-19.Major Activities Reviewed Included,Radiation Protection,Environ Protection,Emergency Preparedness,Radwaste Mgt, Transportation & Maint.No Violations Were Noted ML20196A4021998-11-20020 November 1998 Submits Response to NRC 981022 RAI Re Licensee Requested Changes to Appendices a & B of License SNM-960.Revised Pages of Subject License,Encl ML20155G5601998-10-30030 October 1998 Responds to Requesting Approval of Route to Be Used for Transport of Spent Fuel from Limerick Nuclear Power Station,Pottstown,Pa to Vallecitos Nuclear Ctr,Pleasanton, CA ML20155A5381998-10-22022 October 1998 Requests Addl Info Re 980709 Application for Amend to License SNM-960,revising Apps a & B.Addl Info,Specified in Encl,Should Be Provided within Thirty Days of Ltr ML20155F4231998-10-0202 October 1998 Advises of Shipment Completion of Two BWR Reactor Fuel Rods from DAEC Under Provisions of SNM-1270 License.Shipment Was Moved Entirely by Tri-State Motor Transport from Palo,Iowa on 980919 to Pleasanton,California on 980920 ML20151X1041998-09-11011 September 1998 Approves 980827 Request to Amend Spent Fuel Shipment Route Approved,Per Sf Shankman to M Kirkland, Designating Use of Interstate 215 Around Salt Lake City,Ut ML20151W6621998-08-18018 August 1998 Forwards Info NRC Classifies as Safeguards Info.Contents Requested to Be Handled & Dispersed Only on need-to-know Basis,Per 10CFR73.21.Without Encl ML20236Q2481998-05-29029 May 1998 Forwards Info Requesting Route Approval IAW 10CFR73 for Shipment of Irradiated Test Fuel Rods from Duane Arnold Energy Ctr to GE Vallecitos Nuclear Ctr.Shipment Will Be Made by GE Nuclear Energy ML20236Q2551998-05-29029 May 1998 Forwards Info Requesting Route Approval IAW 10CFR73 for Shipment of Irradiated Test Fuel Rods from Philadelphia Electric Co,Limerick Nuclear Power Station to Vallecitos Nuclear Ctr.Shipment Will Be Made by GE ML20247B8371998-04-29029 April 1998 Responds to Violations Noted in Insp Repts 70-0754/97-02 & 70-0754/98-01.Corrective Actions:Concluded That Any Measured Gross Alpha or Beta Radioactivity in Contents of Imhoff Tank Resulted from Naturally Occurring Radioisotopes ML20212H3001998-03-25025 March 1998 Forwards GE 1997 Annual Rept, Which Provided Updated GE Corporate & Financial Info ML20217D5851998-03-24024 March 1998 Forwards Insp Rept 70-0754/98-01 on 980224-26 & 0305.No Violations Noted.Conduct of Activities Was Characterized by Implementation of Effective Programs in Areas of Mgt Organization & Controls & Operational Event Review ML20217Q0361998-02-12012 February 1998 Forwards Amend 1 to Licensee SNM-960,updating License to Reflect Organizational Changes & Changes to Environ Action Levels.Safety License Condition S-1 Revised to Include Date of 970604.Corrected Ltr ML20203B9241998-02-12012 February 1998 Forwards Amend 1 to License SNM-960,updating License to Include Organizational Changes & Changes to Environ Action Levels & Safety Evaluation ML20202D5941998-02-0505 February 1998 Advises That Inbound Shipment from Empresa Nacional Del Uranio,S.A.(Enusa) of U Scrap Being Returned for re-cycle Consisting of UO2 Packed in 1 USA/4986/AF & 59 USA/0220/AF Packages Has Been Completed on Schedule ML20202D6141998-01-19019 January 1998 Provides Advance Notice of Inbound Shipment of UO2 Packed in 1 USA/4986/AF & 50 USA/0220/AF Packages to GE Wilmington, Delaware on 980130 ML20198B7631997-12-17017 December 1997 Forwards Partially Withheld Insp Rept 70-0754/97-201 on 971117-18.No Violations Noted.Rept Details Withheld (Ref 10CFR73.21) ML20197A8121997-12-16016 December 1997 Forwards Insp Rept 70-0754/97-02 on 971201-09.No Violations Noted.Conduct of Activities at Facility Characterized by Implementation of Effective Programs in Areas of Radiation Safety,Radioactive Effluents,Environ Protection & EP ML20198Q6411997-11-0404 November 1997 Responds to Ieb 97-002, Puncture Testing of Shipping Packages Under 10CFR71. Requested Actions of Item 1 Conducted for Three Certified Type B & Fissile Matl Shipping Packages.Items 2 & 3 Not Applicable ML20212E9921997-10-30030 October 1997 Submits 30-day follow-up Rept Re Failure of Criticality Detector Sys Alarm to Sound on 971001 & 1002 When Ambe Neutron Check Source Was Placed to Detector ML20217C3131997-10-29029 October 1997 Forwards Corrected Pages to Approval Dtd 971017.Pages Reflect Typo in Iowa Portion of Route Whereby I-235 Replaced w/I-35 ML20211A0191997-08-15015 August 1997 Forwards Info Requesting Route Approval IAW 10CFR73,for Shipment of Irradiated Test Fuel Rods ML20141B7881997-06-0404 June 1997 Forwards Replacement Pages to App a, License Conditions for Vallecitos Nuclear Ctr, & App B, Demonstration for SNM License Renewal for Vallecitos Nuclear Ctr to Current License SNM-960 ML20141J3091997-05-20020 May 1997 Second Final Response,For Dockets 5000231,7000754 & 7001066, to FOIA Request for Documents.Records in App B Encl & Will Be Available in Pdr.Forwards Computer Printout of Records Available in PDR ML20141C1351997-05-14014 May 1997 Discusses 970225 Request for Approval of Route to Be Used for Transport of Spent Fuel from TMI Nuclear Power Station Near Middletown,Pa,To Vallecitos Nuclear Ctr,Pleasanton,Ca. Arrangements W/Law Enforcement Agencies,Completed ML20137X8951997-04-16016 April 1997 Forwards Insp Rept 70-0754/97-01 on 970331-0403.No Violations Noted.Lack of Timeliness in Responding to Internal Insp Findings & Issuance of Safety Insp Repts Indicate Need for Mgt Attention in Subj Area ML20137L3381997-04-0303 April 1997 Responds to 970224 Request for Approval of Route to Be Used for Transport of Spent Fuel from Dundalk Marine Terminal, Baltimore,Md to Vallecitos Nuclear Ctr,Pleasanton,Ca ML20135F8551997-02-25025 February 1997 Forwards Info Re Request for Route Approval IAW 10CFR73,for Shipment of Irradiated Test Fuel Rods ML20135F8601997-02-24024 February 1997 Forwards Info Re Request for Route Approval IAW 10CFR73, for Shipment of Irradiated Test Fuel Rods ML20135F7611996-12-10010 December 1996 Informs That Mf Weber Branch Chief for Fuel Cycle Licensing Branch,Effective 961118 ML20135D4471996-12-0202 December 1996 Forwards Insp Rept 70-0754/96-02 on 961112-15 & 18.No Violations Noted ML20129H3231996-09-17017 September 1996 Submits Advance Notice of Import Shipment of SNM Consisting of 1,488 Nuclear Fuel Rods in Form of UO2,to Ge,Wilmington, Nc ML20128N5911996-08-27027 August 1996 Submits Advance Notification of Inbound Shipment of Special Nuclear Matl of Low Strategic Significance from Hanover, Germany to San Jose,Ca ML20058J1721993-12-0808 December 1993 Forwards Revised Pages to App a Re Proposed License Conditions & App B Re Demonstration Section to Licensee Current Application for Renewal of License SNM-690 ML20056H6211993-09-0808 September 1993 Notification of 931005-08 Meetings in Pleasanton,Ca to Discuss License Renewal ML20045F8081993-07-0101 July 1993 Discusses 930616 Request Re Approval of Highway Route for Transporting Irradiated Reactor Fuel from Quad Cities Nuclear Power Station,Cordova,Il,To GE Vallecitos Nuclear Ctr,Pleasanton,Ca.Document Contains Safeguard Info ML20045E0771993-06-24024 June 1993 Responds to Licensee 930423 Request for Approval of Route to Be Used for Transport of Spent Fuel from Hope Creek Nuclear Station,Salem,Nj to GE Vallecitos Nuclear Ctr,Pleasanton,Ca ML20035B8181993-03-26026 March 1993 Notifies That within NRC Ofc of Nuclear Matl Safety & Safeguards,Responsibility for Licensing of Facility Has Been Transferred from Fuel Cycle Safety Branch to Division of Fuel Cycle Safety Safeguards ML20126F3831992-12-17017 December 1992 Grants 921007 Request for Approval of Route to Be Used for Transportation of Spent Fuel from Duane Arnold Energy Ctr, Palo,Iowa to GE Company Facility,Pleasanton,Ca.Listed Encls Constitute Approval of Route ML20029B5531991-03-0606 March 1991 Forwards Updated Page A-4-5 to App a of License SNM-960, Reflecting Changes to Vendor Nuclear Energy Organization 1999-09-29 Category:NRC TO VENDOR/MANUFACTURER MONTHYEARML20059F6501990-08-27027 August 1990
[Table view]Advises That 900820 Request for Petition for Reconsideration of Denial of Specific Exemption from Financial Assurance Instrument Requirements of 10CFR50 & 70 Under Review.Request for Temporary Extension of 900831 Filing Deadline Granted ML20043H8451990-06-15015 June 1990 Forwards Insp Rept 70-0754/90-01 on 900521-24 & Notice of Violation ML20006A8851990-01-26026 January 1990 Ack Receipt of 890421 Application for Renewal of License SNM-960.License Will Not Expire Until Application Finally Determined by Commission ML20246L1191989-08-31031 August 1989 Advises That 890404 Request for Approval of Route to Transport Spent Reactor Fuel Meets 10CFR73.37 & Approved. NRC Has Completed Arrangements W/Law Enforcement Agencies Along Route ML20246F3241989-08-23023 August 1989 Forwards Insp Rept 70-0754/89-03 on 890809-11 & 14.No Violations Noted ML20247D6411989-07-18018 July 1989 Advises That 890511 Request for Approval of Route for Transport of Spent Fuel Consistent w/10CFR73.37 & Approved. Deviation from Route Requires Notification as Soon as Possible ML20245A2651989-06-13013 June 1989 Advises of Approval of Route for Transport of Spent Reactor Fuel Per 890224 Request.W/Sanitized Safeguards Info Encl ML20244C8911989-06-0505 June 1989 Ack Receipt of 890424 Application for Renewal of License SNM-960.License Shall Not Expire Until Application for Renewal Has Been Finally Determined by Commission ML20244C8581989-06-0202 June 1989 Issues Amend 4 to License SNM-960,per Encl Pages 1 & 4 to License,Amending Condition 12 to Incorporate Changes for Radiological Contingency Plan Submitted by ML20247D1651989-05-0909 May 1989 Forwards Safety Insp Rept 70-0754/89-02 on 890403-11.No Violations Noted ML20205T0511988-11-0303 November 1988 Notifies of 890110 Meeting W/Region V in San Francisco,Ca Re NRC Reactor Operator Licensing Program ML20154G6511988-09-13013 September 1988 Forwards Safety Insp Rept 70-0754/88-02 on 880801-05 & 0825. No Violations Noted ML20151X8381988-08-16016 August 1988 Forwards Announcement of Criticality Alarm Sys Workshop Sponsored by Doe.W/O Stated Encl ML20151U7071988-08-11011 August 1988 Informs of NRC Interpretation of Section 10CFR50.74(a) Re Changes in Operator or Senior Operator Status.When Operator Goes from Licensed to Nonlicensed Position W/Possibility of Reassignment to Licensed position,50.74 Does Not Apply ML20155B6331988-06-0606 June 1988 Forwards Revised Pages 1 & 4 of License SNM-960 (Identifying as Amend 3 on Page 1 & Revising Condition 12 on Page 4), Safety Evaluation & Determination of Eligibility for Categorical Exclusion for Radiological Contingency Plan ML20155D2781988-06-0303 June 1988 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 70-0754/88-01 ML20153E4481988-05-0303 May 1988 Forwards Safety Insp Rept 70-0754/88-01 on 880322-30 & 0411 & Notice of Violation ML20151L3371988-04-15015 April 1988 Confirms That License Condition 7.2.4 of License SNM-960 Covers Blending Activities as Proposed in ML20234F0041987-12-30030 December 1987 Forwards Safety Insp Rept 70-0754/87-04 on 871202-14.No Violations Noted ML20235C6841987-09-16016 September 1987 Notifies of 871027-28 Nuclear Fuel Cycle Licensee Workshop in Atlanta,Ga to Bring Together NRC Officials & Fuel Cycle Licensee Representatives to Discuss Various NRC Programs & Policies ML20237G4921987-08-28028 August 1987 Forwards Safety Insp Rept 70-0754/87-03 on 870728-30.No Violations Identified ML20234C6231987-06-30030 June 1987 Forwards Pages 1 & 4 to Amend 2 to License SNM-960,changing Condition 12 to Incorporate 870406 Changes to Radiological Contingency Plan ML20215H6151987-06-16016 June 1987 Forwards Safeguards Insp Rept 70-0754/87-02 on 870602-04.No Violations or Deviations Identified ML20213G2301987-05-11011 May 1987 Forwards Safety Insp Rept 70-0754/87-01 on 870407-10 & 21.No Violations Noted ML20207T8881987-03-20020 March 1987 Approves Encl Sanitized Spent Fuel Route Survey for Transport of Spent Reactor Fuel from Lynchburg,Va to Pleasanton,Ca,Per 870202 Request ML20212E5731987-02-19019 February 1987 Approves Encl Sanitized Spent Fuel Route Survey for Transport of Spent Reactor Fuel from Morris,Il to Lynchburg,Va,Per 870202 Request.Assurance of Highway Safety Discussed ML20210D9311987-02-0303 February 1987 Forwards Revised Page 1 to License SNM-960,identified as Amend 1 & Revised Annex A,Clarifying Responsibilities of Criticality Safety Manager & Vallecitos Technological Safety Council.Safety Evaluation Also Encl ML20207N0401987-01-0909 January 1987 Forwards Safety Insp Rept 70-0754/86-03 on 861031,1114,21 & 24.Insp Consisted of Confirmatory Radiological Surveys Performed Following Decontamination.Radwaste Storage Area Meets Guidelines for Unrestricted Use ML20214E3561986-11-19019 November 1986 Approves Route,Contained in ,To Transport Spent Reactor Fuel from West Jefferson,Oh to Morris,Il. Appropriate State Officials Should Be Contacted During Seasonal Periods W/Inclement Weather.Route Encl ML20215N8381986-10-31031 October 1986 Forwards Safety Insp Rept 70-0754/86-02 on 860908-18.No Violations Noted.Rept Reflects in-ofc Insp Activities & Info Developed by Telcon,Through 861016 ML20211D3341986-10-14014 October 1986 Approves 860822 & 29 Requests for Encl Route for Transport of Spent Reactor Fuel from Monticello,Mn to Morris,Il. Route Meets Requirements of 10CFR73.37 & Acceptable ML20210K7691986-04-25025 April 1986 Forwards Safety Insp Rept 70-0754/86-01 on 860228-0307.No Violation Noted ML20210K4871986-04-23023 April 1986 Approves 860321 Proposed Route for Transport of Spent Reactor Fuel from Cordova,Il to Pleasanton,Ca.Sanitized Approved Route Encl ML20198H0731986-01-27027 January 1986 Approves 851115 Request for Route for Transport of Spent Reactor Fuel from Morris,Il to Richland,Wa.Route Meets Regulatory Requirements in Accordance w/10CFR73.37 for Shipments of Spent Fuel.Approved Route Encl ML20138B3531985-10-0808 October 1985 Forwards Insp Rept 70-0754/85-02 on 850904-19.No Violations Noted ML20135C9241985-09-0909 September 1985 Approves Encl Spent Fuel Route from Monticello,Mn to Pleasanton,Ca in Response to ML20024B8871983-01-13013 January 1983 Clarifies Safeguards Licensing Policy Re Inventory Requirements of SNM Contained in Liquid & Solid Waste Matls Stored at Site.Request for Exception from 10CFR70.51 Should Be Submitted for Storage of Holding Account Waste Discards ML20054L4181982-06-25025 June 1982 Requests Integrated site-wide Emergency Preparedness Plan by 821103 ML20053B6381982-05-24024 May 1982 Informs of 10CFR170,Category 13 Fee Requirement for 820128 Request for Approval of Route to Be Used for Shipment of Spent Fuel ML20052E5331982-04-30030 April 1982 Advises That Invoice Will Be Issued Re Review of 820128 Request for Approval of Route for Shipment of Irradiated Reactor Fuel ML20052C1051982-04-27027 April 1982 Notifies of Telephone Number Change for NRC Operations Ctr as of 820601.Facility Procedures Should Be Revised ML20040F9411982-01-22022 January 1982 Responds to .Period for GE to Prepare & Submit Supplemental Data Requested in NRC Extended. Extension Granted So That Radiological Contingency Plan Can Be Incorporated Into site-wide Emergency Plan NUREG-0810, Advises That Radiological Contingency Plan Submitted on 811030 Is Incomplete & Fails to Conform to Guidance in Std Format Included w/810211 Order.Addl Info Should Be Sent by 820127.NUREG-0810 Encl.W/O Encl1981-12-28028 December 1981 Advises That Radiological Contingency Plan Submitted on 811030 Is Incomplete & Fails to Conform to Guidance in Std Format Included w/810211 Order.Addl Info Should Be Sent by 820127.NUREG-0810 Encl.W/O Encl ML20040D5601981-12-22022 December 1981 Forwards Effects of Natural Phenomena on GE Vallecitos Nuclear Ctr - Bldg 102 at Pleasanton,Ca. Rept Is Summary of All Increments of Subj Analysis.Nrc Endorsed Summary in Support of Renewal of License SNM-960.W/o Encl ML20039B9931981-12-11011 December 1981 Informs That No Addl Fee Required for 810814 Application for Amend to License SNM-9160 ML20039A3731981-12-0101 December 1981 Advises That Invoice for Shipping Route Approval Review Fee Is Forthcoming ML20033A1361981-10-30030 October 1981 Informs That License SNM-960 Is Amended Authorizing Recovery of 150 G U-235 to Achieve Enrichment of 4% or Less ML20005C0251981-10-30030 October 1981 Forwards IE Insp Rept 70-0754/81-02 on 810915-18.No Noncompliance Noted.Failure to Follow Internal Procedures in Loading Nuclear Matl Vault Not Cited as Noncompliance ML20032B7231981-10-23023 October 1981 Requests Info Re Decommissioning Plan Needed for Renewal of License by 811130.Info Re Decontamination & Decommissioning at End of Plant Life,Decontamination to Unrestricted Use Levels & Financial Responsibility Required ML20032B1251981-10-20020 October 1981 Notifies That Ofc of Controller Will Be Billing Company for Review of 810828 Request for Use of Route for Shipment of Irradiated Reactor Fuel 1990-08-27 Category:OUTGOING CORRESPONDENCE MONTHYEARML20212L9931999-10-0505 October 1999
[Table view]Forwards Fr Notice,Notice of Public Meeting & Agenda for Public Informational Meeting to Be Held on 991020 Re Safety of Periodic Shipments of Irradiated Nuclear Fuel for Post Irradiation Exam at GE Vallecitos Site ML20210T8531999-08-12012 August 1999 Forwards Notice to Fr Concerning GE-Vallecitos Nuclear Center Application for Renewal of License SNM-960 & Solicitation for Public Meeting If Needed ML20210E9361999-07-26026 July 1999 Informs That Staff Review of 990121 Application Requesting Renewal of License SNM-690,has Identified Addl Info Needed. Info Specified in Encl Should Be Provided within Thirty Days of Ltr ML20205Q4351999-04-15015 April 1999 Approves Route Described in Re Transport of Spent Fuel from Dundalk Marine Terminal Baltimore,Md,To Vallecitos Nuclear Ctr,Pleasant,Ca ML20204J2411999-03-24024 March 1999 Ack Receipt of Application for Renewal of License SNM-960, Transmitted by .Staff Has Conducted Preliminary Review of Renewal Application & Accepted Application for Formal Review.Review Schedule Will Be Provided in Future ML20203B3901999-01-27027 January 1999 Forwards Amend 2 to License SNM-960,updating Technical, Organizational & Environ Action Level Changes.Safety License Condition Has Been Revised to Include Dates of 980709 & 1120.Safety Evaluation Rept Also Encl ML20198S8981999-01-0404 January 1999 Forwards Insp Rept 70-0754/98-02 on 981116-19.Major Activities Reviewed Included,Radiation Protection,Environ Protection,Emergency Preparedness,Radwaste Mgt, Transportation & Maint.No Violations Were Noted ML20155G5601998-10-30030 October 1998 Responds to Requesting Approval of Route to Be Used for Transport of Spent Fuel from Limerick Nuclear Power Station,Pottstown,Pa to Vallecitos Nuclear Ctr,Pleasanton, CA ML20155A5381998-10-22022 October 1998 Requests Addl Info Re 980709 Application for Amend to License SNM-960,revising Apps a & B.Addl Info,Specified in Encl,Should Be Provided within Thirty Days of Ltr ML20151X1041998-09-11011 September 1998 Approves 980827 Request to Amend Spent Fuel Shipment Route Approved,Per Sf Shankman to M Kirkland, Designating Use of Interstate 215 Around Salt Lake City,Ut ML20217D5851998-03-24024 March 1998 Forwards Insp Rept 70-0754/98-01 on 980224-26 & 0305.No Violations Noted.Conduct of Activities Was Characterized by Implementation of Effective Programs in Areas of Mgt Organization & Controls & Operational Event Review ML20217Q0361998-02-12012 February 1998 Forwards Amend 1 to Licensee SNM-960,updating License to Reflect Organizational Changes & Changes to Environ Action Levels.Safety License Condition S-1 Revised to Include Date of 970604.Corrected Ltr ML20203B9241998-02-12012 February 1998 Forwards Amend 1 to License SNM-960,updating License to Include Organizational Changes & Changes to Environ Action Levels & Safety Evaluation ML20198B7631997-12-17017 December 1997 Forwards Partially Withheld Insp Rept 70-0754/97-201 on 971117-18.No Violations Noted.Rept Details Withheld (Ref 10CFR73.21) ML20197A8121997-12-16016 December 1997 Forwards Insp Rept 70-0754/97-02 on 971201-09.No Violations Noted.Conduct of Activities at Facility Characterized by Implementation of Effective Programs in Areas of Radiation Safety,Radioactive Effluents,Environ Protection & EP ML20217C3131997-10-29029 October 1997 Forwards Corrected Pages to Approval Dtd 971017.Pages Reflect Typo in Iowa Portion of Route Whereby I-235 Replaced w/I-35 ML20141J3091997-05-20020 May 1997 Second Final Response,For Dockets 5000231,7000754 & 7001066, to FOIA Request for Documents.Records in App B Encl & Will Be Available in Pdr.Forwards Computer Printout of Records Available in PDR ML20141C1351997-05-14014 May 1997 Discusses 970225 Request for Approval of Route to Be Used for Transport of Spent Fuel from TMI Nuclear Power Station Near Middletown,Pa,To Vallecitos Nuclear Ctr,Pleasanton,Ca. Arrangements W/Law Enforcement Agencies,Completed ML20137X8951997-04-16016 April 1997 Forwards Insp Rept 70-0754/97-01 on 970331-0403.No Violations Noted.Lack of Timeliness in Responding to Internal Insp Findings & Issuance of Safety Insp Repts Indicate Need for Mgt Attention in Subj Area ML20137L3381997-04-0303 April 1997 Responds to 970224 Request for Approval of Route to Be Used for Transport of Spent Fuel from Dundalk Marine Terminal, Baltimore,Md to Vallecitos Nuclear Ctr,Pleasanton,Ca ML20135F7611996-12-10010 December 1996 Informs That Mf Weber Branch Chief for Fuel Cycle Licensing Branch,Effective 961118 ML20135D4471996-12-0202 December 1996 Forwards Insp Rept 70-0754/96-02 on 961112-15 & 18.No Violations Noted ML20056H6211993-09-0808 September 1993 Notification of 931005-08 Meetings in Pleasanton,Ca to Discuss License Renewal ML20045F8081993-07-0101 July 1993 Discusses 930616 Request Re Approval of Highway Route for Transporting Irradiated Reactor Fuel from Quad Cities Nuclear Power Station,Cordova,Il,To GE Vallecitos Nuclear Ctr,Pleasanton,Ca.Document Contains Safeguard Info ML20045E0771993-06-24024 June 1993 Responds to Licensee 930423 Request for Approval of Route to Be Used for Transport of Spent Fuel from Hope Creek Nuclear Station,Salem,Nj to GE Vallecitos Nuclear Ctr,Pleasanton,Ca ML20035B8181993-03-26026 March 1993 Notifies That within NRC Ofc of Nuclear Matl Safety & Safeguards,Responsibility for Licensing of Facility Has Been Transferred from Fuel Cycle Safety Branch to Division of Fuel Cycle Safety Safeguards ML20126F3831992-12-17017 December 1992 Grants 921007 Request for Approval of Route to Be Used for Transportation of Spent Fuel from Duane Arnold Energy Ctr, Palo,Iowa to GE Company Facility,Pleasanton,Ca.Listed Encls Constitute Approval of Route ML20065S7731990-12-20020 December 1990 Forwards Amend 5 to License SNM-960,SER & 901220 Memo Granting Categorical Exclusion.Amend Deletes License Condition 12 Re Requirements for Radiological Contingency Plan ML20058C3291990-10-24024 October 1990 Forwards Insp Rept 70-0754/90-02 on 900904-07,24-25 & 1005. No Violations or Deviations Noted ML20059F6501990-08-27027 August 1990 Advises That 900820 Request for Petition for Reconsideration of Denial of Specific Exemption from Financial Assurance Instrument Requirements of 10CFR50 & 70 Under Review.Request for Temporary Extension of 900831 Filing Deadline Granted ML20043H8451990-06-15015 June 1990 Forwards Insp Rept 70-0754/90-01 on 900521-24 & Notice of Violation ML20055C9401990-05-0707 May 1990 Forwards Response to Questions Re Decommissioning of Pu Facilities ML20006A8851990-01-26026 January 1990 Ack Receipt of 890421 Application for Renewal of License SNM-960.License Will Not Expire Until Application Finally Determined by Commission ML20246L1191989-08-31031 August 1989 Advises That 890404 Request for Approval of Route to Transport Spent Reactor Fuel Meets 10CFR73.37 & Approved. NRC Has Completed Arrangements W/Law Enforcement Agencies Along Route ML20246F3241989-08-23023 August 1989 Forwards Insp Rept 70-0754/89-03 on 890809-11 & 14.No Violations Noted ML20247D6411989-07-18018 July 1989 Advises That 890511 Request for Approval of Route for Transport of Spent Fuel Consistent w/10CFR73.37 & Approved. Deviation from Route Requires Notification as Soon as Possible ML19327B4071989-06-28028 June 1989 Advises That NRC Form 327s Forwarded to NMSS or Region II Ofc to Be Marked as 10CFR2.790(d) or Natl Security Info ML20245A2651989-06-13013 June 1989 Advises of Approval of Route for Transport of Spent Reactor Fuel Per 890224 Request.W/Sanitized Safeguards Info Encl ML20244C8911989-06-0505 June 1989 Ack Receipt of 890424 Application for Renewal of License SNM-960.License Shall Not Expire Until Application for Renewal Has Been Finally Determined by Commission ML20244C8581989-06-0202 June 1989 Issues Amend 4 to License SNM-960,per Encl Pages 1 & 4 to License,Amending Condition 12 to Incorporate Changes for Radiological Contingency Plan Submitted by ML20247D1651989-05-0909 May 1989 Forwards Safety Insp Rept 70-0754/89-02 on 890403-11.No Violations Noted ML20205T0511988-11-0303 November 1988 Notifies of 890110 Meeting W/Region V in San Francisco,Ca Re NRC Reactor Operator Licensing Program ML20154G6511988-09-13013 September 1988 Forwards Safety Insp Rept 70-0754/88-02 on 880801-05 & 0825. No Violations Noted ML20151X8381988-08-16016 August 1988 Forwards Announcement of Criticality Alarm Sys Workshop Sponsored by Doe.W/O Stated Encl ML20151U7071988-08-11011 August 1988 Informs of NRC Interpretation of Section 10CFR50.74(a) Re Changes in Operator or Senior Operator Status.When Operator Goes from Licensed to Nonlicensed Position W/Possibility of Reassignment to Licensed position,50.74 Does Not Apply ML20155B6331988-06-0606 June 1988 Forwards Revised Pages 1 & 4 of License SNM-960 (Identifying as Amend 3 on Page 1 & Revising Condition 12 on Page 4), Safety Evaluation & Determination of Eligibility for Categorical Exclusion for Radiological Contingency Plan ML20155D2781988-06-0303 June 1988 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 70-0754/88-01 ML20153E4481988-05-0303 May 1988 Forwards Safety Insp Rept 70-0754/88-01 on 880322-30 & 0411 & Notice of Violation ML20151L3371988-04-15015 April 1988 Confirms That License Condition 7.2.4 of License SNM-960 Covers Blending Activities as Proposed in ML20234F0041987-12-30030 December 1987 Forwards Safety Insp Rept 70-0754/87-04 on 871202-14.No Violations Noted 1999-08-12 |
Text
,;
-a p7 ]v%
f 7,
. Docket No.70-754 APR 251986 h*
General Electric Company Vallec'itos Nuclear Center-
'P. O. Box 460.
94566
.-Pleasanton, California Attent[ ion:
Mr. R.;W. Darmitzel, Manager Irradiation Processing Operation Gentlemen:
Subj ect:. Inspection at:Vallecitos Nuclear Center This-refers to a routine safety inspection conducted by Mr. B. L. Brock of this office between February 28 and March 7,1986, of activities authorized under NRC License No. SNM-960 and to the discussion of our findings held-with you and Mr. G. E. Cunningham at -the conclusion of the inspection. This report also : reflects the in-office inspection activities and information developed by
. telephone through April 9,-1986.
- Areas examined during this inspection are described in the enclosed inspection report.. Within these areas, the inspection consisted of selective
. examinations of procedures and representative records,- interviews with personnel, and observations by the inspectors.
-No violEtions of NRC requirements were identified within the scope of this inspection.
In accordance with 10,CFR 2.790(a), a copy of this letter and the enclosure will be placed.in the NRC Public Document Room.
Should you have any questions concerning this inspection, we will be glad to discuss-them with you.
7-Sincerely, j
James'[. Montgomery,Cief
~ Nuclear Materials Safety and Safeguards Branch Enclosu're: Inspection Report No. 70-754/86-01 cc w/ enclosure:
rL. C. Rouse, NMSS:HQ; State of CA bec w/ enclosure:
1RSB/Docume'npControlDesk(RIDS);G. Cook;B.Faulkenberry;J. Martin
}
bec w/o enclosure: LFMB Region V dot, g
Brock Thomaj Mostgomery
>4/N/86 4
//86 4/ 6/86 2
Bbo4290050860 54 PDR ADOCK O 0
~' '
PDR.
/
(-
1
\\
_