Approves Encl Sanitized Spent Fuel Route Survey for Transport of Spent Reactor Fuel from Morris,Il to Lynchburg,Va,Per 870202 Request.Assurance of Highway Safety Discussed
ML20212E573
Person / Time
Site: 07000754
Issue date: 02/19/1987
From: Mccorkle G
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Kirkland M
GENERAL ELECTRIC CO.
References
NUDOCS 8703040379
Download: ML20212E573 (14)


Text

_ _ _ _ _ _ _ _ - - _ - - - - _ - _ - _ - - _ _ _ - - - - -. - - - -

a ELA084HWR Or

,4 Es%a taben JG.,

FEB 191987 y/

g W * [ #

n


j SGRT:CRH 07000754050R

,e $)~$$

General Electric Company ATTN: Mr. M. W. Kirkland (Mail Code 512)

Hazardous Material Transportation Specialist 175 Curtner Avenue San Jose, Californit. 95125 Gentlemen:

This is in regard to your request for approval of a route to be used for transport of spent reactor fuel as contained in your lotter of February 2,1987.

The route requested in your letter of February 2,1987 is judged to neet the regulatory requirements in accordance with 10 CFR 73.37 for shipments of l

spent fuel from Morris, Illinois to Lynchburg, Virointa and is approved.

l In the event your carrier is required to deviate from the approved route, please call the contact listed on page two of this letter as soon as possible providing the details.

l

'Jrrangements with law enforcement agencies along the route have been completed by the flRC staff. Data relating to these arrangenents and a copy of the approved route are enclosed.

This information is to be incorporated into your shipnent plans and provided to your carrier along with instructions regarding its use.

Please note that assuring highway safety is the responsibility of the licensee and carrier and our approval is not intended to provide relief in this regard.

6 During seasonal periods when inclement weather with accompanying hazardous road conditions can occur with short notice, the appropriate state police should be contacted with regard to road conditions before a shipnent connences.

Please note that the notification requirements of 10 CFR 73.37(f) and 73.72 for each shipment still apply. When making a notification to a governor or his designee, it should be very specific especially with regard to notification of series shipments. Written notification must designate exactly how many individual shipnents are to be included.

In the event the number of shipaents in a series is revised, the change notification should indicate that it is (Me

/m. /up,"

UPONRIMOVALMAfbHfENTftGJEL u wd Docu idnsmit (fewith b de _

d nfmMgf

~

Copt sSafe d nformation y

......................................MEMp. ?$.....{ g{

A j"..................

= cr>

~

d

~

~

d V

L cucums) "g030$0379670219oocn07000y54 g N;m M 2'aiio,soinacu o24o OFFICIAL RECORD COPY

  • u.s.apo ma-4eo-aw p
qw.

AL__"*~

" ~

-m

. m

w 7

g

(

y Mr. M. W. Kirkland FEB 191987 a revision of the original notification and an increase or decrease in the number of shipments.

In addition, the change notification should specify that the information for any of the shipments in the revised series may not be decontrolled until ten days after the arrival at the destination of the last shipment in that series.

Should you require additional information or have questions concerning this matter, please contact Charles Hillman of my staff at (301) 427-4220.

Sincerely, f

George W. McCorkle, Chief Safeguards Reactor and Transportation Licensing Branch Division of Safeguards, NMSS

Enclosures:

As stated Morris /Lynchburg(81A) 07000754Q50R DISTRIBUTION:

w/ enclosure w/o enclosure Docket File 70-754 NMSSi/f Case File 70-754 SGRT r/f Region I RFonner Region II LCRouse Region III DWeiss CHillman RRentschler RBurnett PDR (Sanitized)

Route only SGagner, PA 9/ ll, SGRT SG b

F/.f../..W...............

o cap..SGRT

................... P. h r............,..(

........g.......g.y

'I..WF14 d.: pag...........O I.l ma 1.............. RRe o ch 9,C.....

o r k1 e,,,,,,,,,,,

................g. h. /B7 02/ 1 /8 787 OC/

...../......./.8 7 res) 02 A v.s.GPO 1983-400 nac ronw 3 e no,.o.uncu o2' OFFICIAL RECORD COPY

.,,, _._, _ 247 h

r i

+

e

-81A

-e T !fi _.

2+

.~ +e SPENT NUCLEAR FUEL ROUTE SURVEY DRESDEN NUCLEAR POWER PLANT

.h MORRIS,. ILLINOIS T

TO BABC0CK AND WILC0X COMPANY FACILITY LYNCHBURG, VIRGINIA MARCH 1987 l,.

81A S

'~

ROAD TRANSPORTATION ROUTE Morris, Illinois to Lynchburg, Virginia TOTAL MILES 1,063 ILLINOIS

1. Dresden Reactor Site to Lorenzo Road east to I-55*

5 miles

2. I-55 south to I-74 77 miles
3. I-74 east to Indiana line 93 miles Subtotal 175 miles INDIANA
4. I-74 east to I-465 71 miles 3
5. 1-465 south / east / north to I-70 25 miles y
6. I-70 east to Ohio line 67 miles Subtotal 163 miles OHIO
7. I-70 east to I-270 93 miles
8. 1-270 south / east to I-70 18 miles
9. I-70 east to West Virginia line 120 miles Subtotal 231 miles WEST VIRGINIA
10. I-70 east to Pennsylvania line Subtotal 14 miles PENNSYLVANIA
11. I-70 east to I-79 19 miles
12. I-79 south to West Virginia line 34 miles Subtotal 53 miles WEST VIRGINIA
13. I-79 sou'th to 0S-48**

11 miles

14. US-48 east to Maryland line**

33 miles Subtotal 44 miles MARYLAND 1

15. US-48 east to 05-40***

43 miles

16. 05-40 east to I-70***

39 miles

17. I-70 east to I-81 24 miles
18. !-81 south to West Virointa line 5 miles Subtotal 111 miles l

! March 1987 i

81A p '.

_ ROAD TRANSPORTATION ROUTE (Cont'd)

-x'Ehi Morris, Illinois to Lynchburg, Virginia t4

+:

WEST VIRGINIA

19. I-81 south to Virginia line Subtotal 25 miles VIRGINIA
20. I-81 :: nth to US-11*

182 miles

21. US-11 south to VA-220 Alt.*

3 miles

22. VA-220 Alt. south to US-460*

6 miles

23. US-460 east to Mt. Athos Rd. (VA-767)*

53 miles

24. Mt. Athos Rd. (VA-767) north to Facility
  • 3 miles Subtotal 247 miles TOTAL MILES 1,063 miles

't Access to or exit from Interstate System.

State Preferred Route, West Virginia, Jan. 4, 1984.

      • State Preferred Route, Maryland Dec.1981. March 1987

81A r

F000 AND FUEL STOPS The businesses and locations listed below were identified by the NRC route analysis teams as possible food and fuel stops. All possible stops along the route are not listed. Only a few of the locations were visited by the NRC teams.

In order to be listed, food and fuel stops were required to be close to the route.

ILLINOIS 1.

Union 76 Auto / Truck'Stop.

I-74, Exit 160, Bloomington/ Normal, McLean County.

2.

Amoco and Skelly Truck Stops.

I-74, Exit 206, Oakwood, Vermilion County.

IN0!ANA 1.

Sunoco Blue / White Truck Stop.

I-74, Exit 61, Pittsboro, Hendricks County.

2.

" Bud's" Marathon Truck Stop.

I-465, Exit 4, Marion County.

3.

TC Truck Plaza.

I-70. Exit to SR-3, New Castle, Henry County.

4.

Union 76 Truck Stop.

I-70, Exit 1568, Richmond, Wayne County.

,y OHIO Y

1.

Sonio Truck Stop "Stop 127".

I-70, Exit 10, Eaton, Preble County.

2.

Texaco Truck Stop of America.

I-70, Exit 36, Montgomery County.

3.

Union 76 Truck Stop.

I-70, Exit 79, Lafayette, Madison County.

4.

Shenandoah Truck Stop with sleep ** 1 accomodations.

I-70, Exit 187, Guernsey County.

WEST VIRGINIA 1.

Truck Stop of America.

I-70, Exit 11, 3 miles west of Pennsylvania border, Ohio County.

PENNSYLVANIA 1.

Union 76 Truck Stop.

I-70, Exit 2, 5 miles east of West Virginia Border, Washington County.

2.

I-81 Truck Stop.

I-79, Exit 1, I mile north of West Virginia Border, Greene County.;

WEST VIRGINIA,Monongalia and Preston Counties.

None.

MARYLAND _ Garrett, Allegany and 'ushington Counties.

None. March 1987

81A 5ja

~[

F000 AND FUEL STOPS (Cont'd)

WEST VIRGINIA

1. Union 76 Truck Stop.

1-81, Exit 20, Berkeley County.

VIRGINIA

1. The Virginia Truck Center (Texaco).

I-81, Exit 73, Toms Brook, Frederick County.

2. Interstate Shell Service Center.

I-81, Exit 64E, Rockingham County.

3. Gulf Truck Stops of America.

I-81, Exit 44, Botetourt County.

't w

l i

l March 1987

w l),

81A ILL ife0IS Statewi<se Imerierni y Naber: (217) 782-3617 PONTIAC PESOTUM WT8T5)a44-3131 9~[2T7) 867-2211 (iwet MI _ CH 9 MT _ CH 9

_ CH 19

_ CH 19. R aaA SP

$P 1*l wt h IL 1 11 i AC it!It It e Pesotun (off route)-

Pf T'2 I

I

~

e Pontiac E Champaten/urtena l

  • 3 I

I I

I-Grundy WI I, Grundy Li vingst on Mc Lean Dewitt Plat t Champaign Verellion g

Mitf 5 IN

! County County County County I

County g County County!

County i

County Juul5DICIl0N I 34 8 14 0

32 l

52 1 6 I

7 1

31 l

22 g

g I

I I

t i

10!At Mlll5 il 3

11 25 57 109 115 122 153 175 ROAD TRANSPORTATION ROUTE - Dresden hclear Power Station. Iqorris. Illinois g

to 8 & W Company Facility. Lynchtnerg. Virginia e

if A Response Center

  • l. Dresden Reactor Site to Lorenzo Road east to I-55 (5 elles);

HP/$P Highway Patrol / State Police

  • 2. I-55 south to I-74 (77 eties);

5 Shertif

  • 3. I-74 east to Indiana line (93 elles);

CP City Police C'P County Police C8 Radte Monitored (Base)

C8 Radio Nnitored (Car)

@MO.

Channel Monitored R

React Group gj.% ?g.

Mi m bile Telephone (useable)

E tscort Required hrch 1987

s-l l.I,

814 INDIANA Statewide Emergency Amber: (311) 232-8248 LATATEIII INDIANAP0tl$

PENDLE TON C WNER$vitLE SP (317)463-1515 SP(317)232 8250 SP(317}778-2121 6 15 umpt.

MT CH 9 MT _ CH 9. R MT _ CH 9 R NE CH 9 I

c==>

c==

c=:2 c==>

Li A; SP

$P SP SP IL IN 1 01 (DI stafayette e Pendleton e Cor.nersville (off route)

E e Indianapolis (off route)

(off route)

~

Vermillion Fountain l Muntgomery l County l County lBoone l Henricks ll 44 g

  • 5
  • 6 l

g g

% rton Hancock Henry Wayne County l County l County l

County County g County l County mites IN 17 23 1

16 33 19 18 24 I6 i

I i

1 I

I i

i JuaI5DICIIGN IOIAL MILES 115 181 198 221 22 8 244 27F 296 314 338 ROAD TRANSPORIAIION ROUTE - Dresden Nuclear Power Station, Morris. Illinois gt y to 8 & W Company Factitty, Lynchbur9, Virginia e

LEA Response Center

  • 4.1-14 west to I-465 (71 miles);

HP/57 Htqhway Patrol / State Police

  • 5.1-465 south / east / west to I-70 (25 miles);

Shertif

  • 6. I-70 east to Ohio (67 miles);

CP City Police C*P County Police CB Radio Monitored (Base)

C8 Radio Nattered (Car)

@No.

ChanneI Monitored R

React Group W .

  • N MT ebelle Telephone (Useable)

E Escort Required k rch 1987

9 e

f i

ii c..

+

I' 81A OHIO P1004 SPRIIIGFIEtD COLINSUS IPT5T3)ii3-II31 e(5131373-9781 Wu-2sso ustm MT _ CH 9. R Mi CH 9. R Mi CN 9/19. R c=s c==:-

c=a itA:

HP HP 19 IN OH e Piqua (off route) e Springfield o Columines l

I l

l 9

9 l

Preble sbatgomery l

Clark hdison Franklin Mitts in County l

County I

County l

County l

County l

Justl50!Cilun 18 23 I

30 15 31 I

I I

i lotAL Mitf 5 338 3%

379 409

+4 455 ROAD TR AllSPORTATION R' KITE - Dresden belear Poues tacion, norris. Illinets gg y to B & W Company facility. Lynchburg Virginia e

LE A Response Center

  • F.1-10 east to I-270 (93 miles);

HPf5P lughuay Patrol / State Police

  • 8.1-270 south / east to 1-10 (18 miles);

5 Sheriff

CP City Police C*P County Police CS Radio Monitored (Base)

C8 Radio Isonttored (Car) kNO.

ChanneI nonitored R

React Grono Mi ebnile Telephone (useable)

E Escort Required N'M i re, fierch 1987

e s

I f

e 81A OHIO hfWARK ZANE 55Itt f CAseRIDGE ST. CLAlt5WILLE-W[6T41927-ooc 6 WIET4J4U-Os4:

IF[UI)US-13sa 6

usept MI CH 9. R

, CH 9. R

, CH 9 CM 9 c=2 c=3 c=2 a=:::a ttA.

If HP MP pp GN WW e hewark e lanesville Cambridge e St. Clairsville e r'

l I

'l ticking Ibskinque Guernsey teleont Mitt 5 15 l

County County g

County l

County JintItoICIIden 30 27 29 28 I

i i

i tolat P:Inf 5 4w an 512 541 569 ROAD TRAR5PORTATI01: RoulE - Dresden Ituclear Power Station Iterris, Illinois ag v to B & W Company Factitty. Lynchburg Virginia e

LE A Response Center

9. I-70 east to West Virginia (120 miles);

HP/W Highway Patrol / State Police 5

Sheriff CP City Police C*P County Police CS Radio Monitored (Sase)

CS Radio Monitored (Car)

ML Chaane1 Monitored R

React Grasp

,4 Mi abbtle Telephone (ttseable)

  • F' I

bcort Required 80erch 1987 W

9 s

a r

qg 81A IK51 VIRGINI A/Pf an5YLVANI A/ WEST VIRGINI A/ptRRYLAIS Whit t thG WASHlhGTDM STAR CITY Ctsg[RLAgg ggAGE85T01st

$P(M4l242-22s2 UTir2T121-5200 5PTT54I5D9-Il01 WI35T17N-2101 FINT17W-2101 O MM

_ (et 9/IT

_ CH 9/19 R. MT ti A sP SP SP SP

$P tas uw WV PA PA WV WV IG gg yy

~e Washington

_ e Star City Cumberland e Negerstenen e e Wheeling

~ ie

  • 11
  • If g

-*13

  • 14 g
  • ls

[

  • 16
  • l i l

Washington mitis In County County l

County County l County County County County Jukl5DICllum 14 29 g

24 26 g

18 31 1

42 I

38 i

I fu! At Mitt s

%9 Sit 3 612 6%

652 680 Til 753 791 ROAD TRANSPORIAIION ROUTE - Dresden leuclear Posser Statten. Starris. Illinois y

to 8 & W Company Factitty. Lynchburg. Virginia e

LEA Response Center

  • 10.

I-70 east to Pennsylvanta (14 miles);

HP/$P Highuay Patrol / State Police

  • ll.

I-70 east to I-79 (19 miles);

5 wertif

  • 12.

I-79 south to West Virginia (34 miles);

CP City Police

  • 13.

I-79 south to US-48 (11 elles);

C'P County Police

CB Radio 8%nitored (Base)

  • 15.

US 48 east to US-40 (43 stles);

C8 Radio stonitered (Car)

  • 16.

t15-40 east to I-70 (39 miles);

Nh0.

Channel Monitored

  • 17.

1-70 east to I-81 (24 miles);

R React Group

  • 18.

1-81 seeth pgst Virginia (5 elles);

MT Mo64le Telephone E

Escort Required Ilarch 1987 1

l

.j

-~

o

.o 814 WEST vtacIntA/vtactnIA MARTthisueG WINCHESTf u WOODSTOCK HARRIS 048uRG STAuNTON LEIlhETON SP(304)297-8901 SP(703)869-2003 SP(703)459-4071 SP(103)434-8593 SP 703)585-2141 2548 (800)572-2260 (800)552-0962 800)552 0962 800 542-W 9 ta ao 7Dmi Cises:

MI. CH 19 MI _ CH 9. R

_ CH 19/9. R MT CH 9 MT _ CH 19 NT CM 9. 19 c==

=

tiA:

$P SP SP 5F SP SP WV l VA se WV skrt ansburg e eWinchester Woodstock e Harrisonburg e e Staesaten e Lenington "19

  • 2O

{

l l

l l

Serteley Frederick Shenandoah g Rockingham l

As9usta g

Rockbridge g

Mitts in County County I

County Comenty Conanty County

,I 33 34 I

JUR 858ICIION 25 25 1

37 I

30 e

I a

l l

TOTAL n!LES 791 816 841 878 908 941 975 '

ROAD TRANSPORTATION ROUTE - Dresden thsclear Pouer Station. 8brris. Illinois g

to B & W Company Factitty. Lynchburg. Virgtala e

LEA Response Center

  • 19. I-81 south to Vir91nta (25 miles);

etP/57 Nigheney PatroI/5 tate PollCe

  • 20. I-81 south to U5-11 (182 miles);

5 Shertif CP City Police C*P County Police CS Radio Monitored (Sase)

CB Radio Monttored (Car) h.

Channel monitored R

Aeact Group Mi mehile Telephone (Useable)

E Escort Ber,:stred March 1987 v.,

~ 1 e

a 1-i VIRClain I

S.

SIA LytEttes SEDFOBO

.e962 SALEM 9T5515425959 N)S28-M37 (404 5FTn00)s42-s*9 (703)380-2019 NT CH9,R 3G,Cet 19, R MT CH 9. R SP

$P COMM:

LVIICISURG SP FACILITY t(A:

a Lynchburg

. Roanonc/ sale.

. seaford a24 t

l CampbeiI g

  • zt *2f I ~91 l l

8edford g

County I

O Roanoke g otetour County l

19 B

Botetourt gCounty County 31 i

g County 3 4 I

6 1

i 1963 Mitts in I

22 I

I e

1944 JtscISD tCII0ss I

100) 10M 1013 i

1116 mots ROAD TRAL 5 PORT Ail 0Il ROUTC - Dresden nuclear Power Statten, s 101 AL Mitl$

915 20.1-81 south to US-II (182 miles);

ll!

  • 21. US-Il South to 14 220 Alt. (3 stles);
  • 22. VA-220 Alt. south to US 460 (6 miles);

IE A Response Center

  • 23. US 460 east to Ott. Athos Road (53 miles) and Highway Patrol / State Police e
  • 24. Mt. Athos 94. north to f acility (3 elles).

HPf5P Sheriff City Police CP County Poltce C*P monitored (Base)

CR Aedio CB Radio nonitored (Car) kNO.

Channel Monttored Itarch 1981 lieact Grcup mile Telephone (Useable)

R MI Escort Sequired E

t

.