Part 21/deficiency Rept Re Limitorque Motor Operators. Initially Reported on 840730.Corrective Action to Be Determined After Contact W/Vendor.Next Rept Anticipated by 850630
ML20099E477
Person / Time
Site: Seabrook  NextEra Energy icon.png
Issue date: 11/01/1984
From: Devincentis J
PUBLIC SERVICE CO. OF NEW HAMPSHIRE
To: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
REF-PT21-85-151-000 PT21-85-151, PT21-85-151-000, SBN-727, NUDOCS 8411210328
Download: ML20099E477 (3)


Text

?.

y n

-i -c SEABROOK STATION Squineedne Omes-.

1671 Worcester toed Fredacham. Mossoche 01701 (417) .E72 8100 Pub 5c Service of NewI4ompshire NEW HAMPSHIRE YANKEE DIVISION November 1, 1984 SBN- 727 T.F. Q2.2.2 United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention: Mr. Richard W. Starostecki, Director Division of Project and Resident Programs Re ferences: (a) Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) PSNH Letter, dated July 30,1984, " Interim 10CFR50.55(e)

Repo rt: Limitorque Motor Operators", J. DeVincentis to R. W. Starustecki (c) Telecon of August 20, 1984, A. L. Legendre, Jr. (YAEC) to Jene Grant (NRC ReF i on I)

Subject:

Interim 10CFr.50.55(e) Report: Limitorque Motor Operators

Dear Sir:

In Reference (b), we submitted a written report on four deficiencies regarding Limitorque motor operators. Two of the deficiencies were determined to be reportable per 10CFR50.55(e). The reportaLility of the two remaining deficiencies is still under evaluation.

On August 20, 1984, we reported, by telephone [ Reference (c)], an additional (Item 5) potential 10CFR50.55(e) deficiency regarding Limitorque motor operators. The reportabili y of this item is under evaluation. The following information is provided for the additional Item (5):

Description of Deficiency Item 5 During Startup Testing, three Limitorque motor operators, Model SMB-00/SHB-000, were found to have inoperative torque switches. The problem was traced to a sheared tab on tne phenolic cam of the torque switch. This tab acts as a locking key and when sheared off permits rotation of the torque switch cam without operation of the torque switch electrical contacts.

1000ElmSt..P.O Box 330.Monchester.NH03105 Telephone (603)669 4000

  • TWX7102207595 8411210328 841101 PDRADOCK05000g S IO ,g.ay

p-. _

- ( ,3 ---+= ~

7_

,e .

_o

s l 1

. SBN-727' United States :Nuclesr Regulatory Corumission - November .1,' .1984_.

Attention: . ,Mr. < Richard W.f Starostecki, Directorc . Page.2.

Safety Implications

, . Item 5 . The . motor operator may fail .to operate And could preventfa '

safety-related valve from performing its safety function.

L Corrective Action Item 5~ ' Corrective action to be. determined after' contact with vendor..

We are proceeding to obtain ~ additional information from the vendor for

' those items on which we have not completely . assessed the reportability- and our -

corrective action.. We will submit. an additional report to Region I, ~ by June 30, 1985.

This letter is being filed pursuant to the interim reporting provisions-of 10CFR50.55(e)(3).

- Very truly yours, '

J. DeVincentis, Director.

. Engineering and Licensing cc: Atomic Safety and Licensing Board Service List Director, Office of Inspection and Enforcement _

U.S. Nuclear Regulatory Commission Washington, DC 20555 1

d 6

9 1

T 1

k t

u

g. p .,-c.- .g.3 .enw ,*.yet,_,,v. eeew -sp,is.,,y y- ep- , -+ . - - ,.es. ,> - - , pg--,-. we au9,. ,y%-9-,p,- p 9 s T+

(! . . ' e,

  • I tilliam S.' Jordan, III Diane Curran -

Harmon, Weiss & Jordan ,

20001 S Street N.W. Brentwood Board of Selectmen Suite 430 RED Dalton Road  ;

Washington, D.C. 20009 Brentwood, New Hampshire 03833 j i

l Robert G..Perlis

  • Office of the Executive Legal Director Edward F. Meany U.S. Nuclear Regulatory Commission Designated Representative of Washington, DC 20555 the Town of Rye 155 Washington Road Robert A. Backus, Esquire Rye, NH 03870 116 Lowell Street P.O. Box 516 -

Calvin A._Canney Mancehster, NH 03105 City Manager City Hall Philip Ahrens, Esquire 126 Daniel Street Assistant Attorney General Portsmouth, NH 03801 Department of the Attorney General Augusta, ME 04333 Dana Bisbee, Esquire Assistant Attorney General Mr. John B. Tanzer Office of the Attorney General Designated Representative of 208 State House 'nnex the Town of Hampton Concord, NH 03301 5 Morningside Drive Hampton, NH 03842 Anne Verge, Chairperson Board of Selectmen Poberta C. Pevear Town Hall Designated Representative of South Hampton, NH 03842 the Town of Hampton Falls Drinkwater Road Patrick J. McKeon Hampton Talls, NH 03844 Selectmen's Office 10 Central Road Mrs. Sandra Cavutis Rye, NH 03870 Designated Representative of the Town of Kensington Carole F. Kagan, Esq.

RFD 1 East Kingston, NH 03B27 Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Jo Ann Shotwell, Esquire '

Assistant Attorney General Mr. Angie Machiros Environmental Protection Bureau Chairman of the Board of Selectmen Department of the Attorney General Town of Newbury One Ashburton Place, 19th Floor Newbury, MA 01950 Boston, MA 02108 Town Manager's Office Senator Gordon J. Humphrey Town Hall - Friend ftreet U.S. Senate Amesbury, Ma. 01913 Washington, DC 20510 (Attn Tom Burack) Senator Gordon J. Humphrey 1 Pillsbury Street Diana P. Randall Concord, NH 03301 70 Collins Street (Attn: Herb Boynton)

SEabrook, NH 03874 Richard E. Sullivan, Mayor Donald E. Chick City Hall Town Manager Newburyport, MA 01950 Town of Exeter 10 Front Street Exeter, NH 03833

- - _ - . . - - - . . _