Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML17309A62129 September 1997Part 21 Rept Re Final Disposition of Masterflow 713 & Embeco 636 Grout Nonconformance Reported by Master Builders,Inc. Licensee Continuing to Monitor shelf-life of Masterflow 713 & Embeco 636 Grouts Produced at Rancho Cucamonga
ML20133E8008 January 1997Deficiency Rept Re Nonconformance Related to Masterflow 713 Grout,Which Master Builders,Inc Has Supplied as Nuclear SR Product to 18 Npps.Cause Unknown.Requests That Listed Info Be Provided to Gain Insight as to Scope & Possible Cause
ML20125C7167 December 1992Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils EnclStroke time
Anchor Darling
ML20127P58623 November 1992Followup to 921005 Part 21 Rept Re Potential Defect in SB/SBD-1 Housing Cover Screws.Procedure Re Replacement of SBD-1 Spring Cover Bolts Encl.All Fasteners Should Be Loosened & Removed.List of Affected Utils Encl
ML20081F60923 April 1991Part 21 Rept Re Edward Controlled Closure Check Valves & Testable Piston Check Valves Dashplate Bolt Failures Due to Rapid Valve Opening or Impulsive Differential Pressure Surge Across Dashplate.Design Changes Recommended
ML20246C08821 June 1989Potential Significant Deficiency Rept Re Possibility That Atmospheric Dump Valves May Fail to Open.Caused by High Bonnet Pressure Not Permitting Actuator to Open Valve.Plug Should Be Reworked to Enlarge Pilot Flow Area
ML20246K74026 April 1989Part 21 Rept Re Incorrectly Stamped Name Plates on Certain Asco Nuclear Qualified Valves.Vendor Will Contact Each Affected Facility & Furnish Correctly Stamped Plates & in Near Future Discontinue Sale of Rebuild Kits for Valves
ML20204H14814 October 1988Final Deficiencty Rept CDR 84-00-13 Re Portions of Control Circuits Not Considered When Evaluating Total Circuit Length for Voltage Drop Calculations.Initially Reported on 840830. Independent Review Confirms Corrective Actions Completed
ML20235Y2909 October 1987Part 21 Rept Re Potential Hazard That Magnet in Class J Industrial Control Relays May Jam When Called to de-energize & Control Circuits May Not Open.Special 120-volt Coil Removed & New Relay Installed
ML20214A13612 May 1987Part 21 Rept Re Capacity of Thermal Compensating Accumulator Being Insufficient to Compensate for Thermal Expansions of Hydraulic Fluid During Full Ambient Temp Transient Required by Customer Specs.Interim & Permanent Mods Identified
ML20211P72123 February 1987Part 21 Rept Re Rockbestos Coaxial Cable Used in Sorrento Electronics Digital & Analog high-range Radiation Monitor. Insulation Resistance at High Temp Not High Enough for Ion Chamber & Associated Electronics to Operate Properly
ML20207J21126 November 1986Final Deficiency Rept CDR-86-00-09 Re Ambient Temp Compensation Calibr Shifts in Veritrak Group a Transmitters. Initially Reported on 860912.Existing Transmitters Will Be Replaced W/Rosemount Transmitters
ML20214R89818 September 1986Supplemental Final Deficiency Rept CDR 85-00-13 Re Lining Defects in Svc Water Sys.Piping Spool Insp Will Be Performed Immediately Due to Exceeding Originally Anticipated Insp Interval
ML20214Q86616 September 1986Final Deficiency Rept CDR 85-00-20 Re Failure of Fire Damper to Close Under Design Airflow Conditions.Initially Reported on 851206.Calculations to Determine Which Fire Dampers Could Fail Under Dynamic Flow Conditions TakenSafe Shutdown
Fire Barrier
ML20210F47416 September 1986Part 21 Rept Re Possible Sticking in Closed or Partially Open Position on Dresser 3050 Diaphragm Valves.Initially Reported on 850118.Disc Caps,Including Chamfers on Outside Diameter,Will Be Modified
ML20210F40812 September 1986Interim Deficiency Rept (CDR 86-00-09) Re Excessive Calibr in Veritrak/Tobar Transmitters.Initially Reported on 860805. Destructive Exam Testing Underway.Nrc Will Be Informed of Status Upon Completion of Tests
ML20214M3184 September 1986Potential Part 21 Rept Re Contromatics Actuator W/Jackscrew/ Handwheel Emergency Override Operator.Jackscrew/Handwheel Should Be Used for Emergency Manual Operation Only.Encl Ltr Also Sent to Listed Utils/Ae Firms
ML20206U14821 August 1986Final Deficiency Rept (CDR 81-00-10) Re Inconsistency in Electrical Cable Tray Support Bolts Design.Initially Reported on 810727.Required Mods to Conduit & Cable Tray Support Connections Installed & InspectedDesign basis earthquake
ML20203M02714 August 1986Final Deficiency Rept (CDR 86-00-08) Re Failure to Ensure Adequate Torquing of Cable Tray hold-down Clamps.Initially Reported on 860716.Clamps Retorqued & Installation & Insp Criteria Revised
ML20212N06525 July 1986Final Deficiency Rept CDR 84-00-06 Re Components & Component Supports Spanning Expansion Joints.Initially Reported on 840405.Field Walkdown of All Bldgs Performed & Design Changes Issued to Assure Sys & Structure Integrity
ML20204J31318 July 1986Final Deficiency Rept (CDR-86-00-07) Re Valve Alignment of ECCS During Cold Leg Recirculation Phase of post-LOCA ECCS Operation.Initially Reported on 860606.Low Head Safety Injection Sys Valve Alignment Will Be Used & FSAR Updated
ML20212C75018 July 1986Interim Deficiency Rept CDR 86-00-08 Re Cable Tray Hold Down Clamps.Initially Reported on 860716.Program to Retorque All Cable Tray Hold Down Clamps in safety-related Areas Implemented.Next Rept by 860815
ML20206S08430 June 1986Part 21 Rept Re Possible Cut Wires in Wire Harness of Bbc Brown Boveri K600/K800 Circuit Breakers.Initially Reported on 860509.Safety Implications Listed.Gear Guard Designed to Prevent Cut Wires
ML20205B39330 June 1986Final Deficiency Rept CDR-86-00-02 Re Ambient Temp Drift Problem W/Veritrak Pressurizer Pressure Transmitters. Initially Reported on 860307.Tobar Pressurizer Pressure Transmitters Installed
ML20212D51924 June 1986Final Deficiency Rept CDR 86-00-06 Re Westinghouse W-24 Operational Amplifiers.Initially Reported on 860605. Westinghouse Nal Cards Having W-24 Operational Amplifiers W/Dated Code 8101 Replaced
ML20211Q27316 June 1986Final Deficiency Rept CDR 84-00-17 Re Insufficient Fillet Weld Size in Coped Area of Structural Steel I-beams Supplied by Cives Steel.Initially Reported on 841026.Mods Issued & Completed to Ensure Integrity of Structural Member
ML20207H47713 June 1986Final Deficiency Rept CDR-79-00-04 Re Potential Undetectable Failure in P-4 Interlock Circuit of Esfas.Installation of Test Switches & Meters as Recommended by Westinghouse & Procedures for Performing Periodic Testing Completed
ML20207H49910 June 1986Final Deficiency Rept CDR-85-00-18 Re Possible Malfunction of Figure 3050 Diaphragm Valves Supplied by Dresser Industries.Initially Reported on 851023.Caused by Valve Disc Cap Not Allowing Disc to Move.Mods to Disc Guides Complete
ML20206F0746 June 1986Final Deficiency Rept (CDR 86-00-03) Re Potential Malfunction of P-10 Permissive.Initially Reported on 860324. Verification That P-10 Permissive Properly Changes State Will Be Made by Observing Bistable Status Lights
ML20211H4076 June 1986Final Deficiency Rept (CDR 85-00-07) Re HVAC Design Defect. Initially Reported on 850409.Fifteen-ton Chiller Unit Added in Equipment Vault Stairways & Electrical Area Above
ML20211H3986 June 1986Final Deficiency Rept (CDR 85-00-16) Re Gauled Threads on Manual Handwheel Operators on safety-related Dampers Causing Operator & Damper to Seize.Initially Reported on 851017.Mods Recommended by Pacific Air Products Completed
ML20211H3845 June 1986Final Deficiency Rept (CDR 83-00-14) Re Supports for Svc Air Sys & Other Sys Carring non-nuclear Safety Designation. Initially Reported on 830714.Affected Lines Reviewed to Determine If Supports Should Be non-nuclear Seismic (NNS-1)
ML20199F5045 June 1986Interim Deficiency Rept (CDR 86-00-06) Re Excessive Shift of Calibr Trip Setpoints on Westinghouse W-24 Operational Amplifiers.Initially Reported on 860501.Amplifiers Will Be Replaced
ML20206F0773 June 1986Final Deficiency Rept (CDR 86-00-04) Re Potential Malfunction in 25 Kva Inverters Mfg by Elgar Corp Due to Improper Stacking of Cable Lugs.Initially Reported on 860509.Actions Complete for Unit 1
ML20206B72928 May 1986Final Deficiency & Part 21 Rept (CDR 85-00-17) Re Potential for Gould-supplied Motor Control Starters to Bind or Seize Contact Carrier Assembly.Reinsp Conducted to Ensure That Washers Installed Under Contact Carrier
ML20206B87028 May 1986Final Deficiency Rept (CDR 84-00-13) Re Control Circuit Cable Lengths.Corrective Actions as Specified in Completed.Solutions Involved Rewiring W/Larger Conductors & Reconfiguration of Some Circuits
ML20206B83720 May 1986Final Deficiency Rept (CDR 85-00-04) Re Blocked Air Hose in Vent Lines from safety-related air-operated Actuators. Initially Reported on 850301.Unit 1 Air Hoses Replaced.Unit 2 Hoses Not Yet Installed
ML20198N16420 May 1986Final Deficiency Rept CDR 84-00-05 Re Overstressed Welds That Join Expansion Joint Assemblies to Fuel Transfer Tube. Initially Reported on 840427.Welds Reworked Per ASME III, Code Class 2 Criteria
ML20198P35020 May 1986Final Deficiency Rept CDR 84-00-08 Re Weld Deficiencies on Fisher Controls Valve Operator Bracket Welds.Initially Reported on 840419.Corrective Actions,Including Insp & Repair of Brackets,Completed
ML20205R85710 May 1986Final Deficiency Rept Re Emergency Feedwater Sys Design Flow Requirements.Initially Reported on 860425.Emergency Feedwater Pump Constant Flow Recirculation Line Replaced W/ New Safety Class 3 Recirculation Line for Each PumpSafe Shutdown
ML20215M7189 May 1986Interim Deficiency Rept (CDR 86-00-04) Re Improper Cable Lug Connections in 25 Kva Inverter.Initially Reported on 860401. Cable Lugs for Dc & Ac Power Supply Connections Will Be Determinated & Properly Reterminated
ML20206C2677 May 1986Interim Deficiency Rept (CDR 86-00-03) Re Potential Malfunction of Reactor Protection Sys Permissive P-10 Function Under Stated Circumstances.Initially Reported on 860324.Corrective Action in Incorporated
ML20141E43110 April 1986Final Deficiency Rept (CRD-85-00-13) Re Failure of Svc Water Sys Spool Linings,Piping Inserts & Valve Liner/Seats. Initially Reported on 850918.At Least One Piping Spool Will Be Removed for Insp of Coating During Each OutageUltimate heat sink
Coatings
ML20141H97910 April 1986Interim Deficiency Rept (CDR 86-00-02) Re Veritrak 76PH2 Pressure Transmitters Calibr Shifts.Initially Reported on 860307.Addl Rept Will Follow Upon Completion of Westinghouse Analysis
ML20155F3182 April 1986Final Deficiency Rept (CRD 85-00-11) Re Incorrect Short Time Delay Band Levers on Brown Boveri K-line Circuit Breaker W/ Overcurrent Trip Device.Initially Reported on 850731.Unit 1 Corrective Action Complete.Unit 2 Being Tracked
ML20199J83431 March 1986Final Deficiency Rept CDR 86-00-01 Re Design of Diesel Generator Air Start Sys.Initially Reported on 860220.Colt Industries Reset Electric Governor & Revised Starting Air Design to Vent Booster Air Via Pilot Air Connection
ML20199H17431 March 1986Interim Deficiency Rept CDR 85-00-19 Re Misapplication of Potter-Brumfield Type Mdr Relays.Initially Reported on 851216.Rectifier Assemblies Will Be Added to Circuitry to Convert Ac Back to Dc to Operate Dc Solenoid Valves
ML20199G45631 March 1986Interim Deficiency Rept (CDR 85-00-17) Re Binding of Contact Carrier Assembly in Gould Motor Control Starters.Initially Reported on 851118.Affected Starters Will Be Replaced or Modified
ML20210E5666 March 1986Interim Potential Deficiency Rept CDR 85-00-20 Re Failure of Fire Damper to Close Under Design Airflow Conditions. Initially Reported on 851206.Final Rept Will Be Submitted When Corrective Actions Completed
ML20141N6255 March 1986Final Deficiency Rept CDR-83-00-10 Re Westinghouse 7300 Process Protection Sys Ntc Card Relays.Initially Reported on 830617.Modified Ntc Printed Circuit Card Installed as Solution to Mercury Wetted Relay Contact Bounce Problem