ML20205B393

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept CDR-86-00-02 Re Ambient Temp Drift Problem W/Veritrak Pressurizer Pressure Transmitters. Initially Reported on 860307.Tobar Pressurizer Pressure Transmitters Installed
ML20205B393
Person / Time
Site: Seabrook  
Issue date: 06/30/1986
From: Devincentis J
PUBLIC SERVICE CO. OF NEW HAMPSHIRE
To: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
CDR-86--2, CDR-86-00-02, SBN-1148, NUDOCS 8608110581
Download: ML20205B393 (2)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _. _ _ _ _ _ _ _ _

o,

SEABROOK STATION Engineering Office Pub 5c SeMee of New Hampshko Now Hampshire Yonkee Divlelen June 30,1986 SBN-1148 T.F.

Q2.2.2 United States Nuclear Regulatory Commission

~ Region I 631 Park Avenue King of Prussia, PA 19406 Attention:

Mr. Richard W. Starostecki, Director Division of Project and Resident Programs

References:

(a) Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) Telecon of March 7, 1986, J. M. O'Connor, W. J. Daley, and A. B. Dubison (YNSD) to J. P. Rogers (Region 1)

(c) PSNH Letter, dated April 10, 1986, " Interim 10CFR50.55(e)

Report; Pressure Transmitters (CDR 86-00-02)"

Subject:

Final 10CFR50.55(e) Report; Pressure Transmitters (CDR 86-00-02)

Dear Sir:

In Reference (c), we described an ambient temperature drift problem with our Veritrak Pressurizer Pressure Transmitters. We committed in Reference (c) to inform you of Westinghouse's analysis and repair of the problem. At this time, Westinghouse has not completed their analysis of the problem. Since this analysis is not completed, we have resolved the issue by installing Tobar pressurizer pressure transmitters. We have performed ambient temperature compensation tests on the Tobar transmitter and determined their ambient temperature compensation shifts are withia our allowable Technical Specification limits.

This is our final report on this item.

l l

Very truly yours, 06081 hh John DeVincentis DR P

Director of Engineering cc: Atomic Safety and Licensing Board Service List P O Box 300. Seatycok. N'i 03874. Telephone (603) 474%21 rm

/

  1. "Y ticna Currsn, Erquira Pater J. Mathswa, Mayor Hermon & Weica City Hall 2001 S. Street, N.W.

Newburyport, MA 01950 Suite 430 Washington, D.C.

20009 Judith H. Mizner Silvergate, Gertner, Baker, Sherwin E. Turk, Esq.

Fine, Good & Mizner Office of the Executive Legal Director 88 Broad Street U.S. Nuclear Regulatory Commission Boston, MA 02110 Tenth Floor Washington, DC 20555 Calvin A. Canney City Manager Robert A. Backus, Esquire City Hall 116 Lowell Street 126 Daniel Street P.O. Box 516 Portsmouth, NH 03801 Manchester, NH 03105 Stephen E. Merrill, Esquire Philip Ahrens, Esquire Attorney General Assistant Attorney General George Dana Bisbee, Esquire Department of The Attorney General Assistant Attorney General Statehouse Station #6 Office of the Attorney General Augusta, ME 04333 25 Capitol Street Concord, NH 03301-6397 Mrs. Sandra Gavutis Chairman, Board of Selectmen Mr. J. P. Nadeau RFD 1 - Box 1154 Selectmen's Office Kennsington, NH 03827 10 Central Road Rye, NH 03870 Carol S. Sneider, Esquire Assistant Attorney General Mr. Angie Machiros Department of the Attorney General Chairman of the Board of Selectmen One Ashburton Place, 19th Floor Town of Newbury Boston, MA 02108 Newbury, MA 01950 Senator Gordon J. Humphrey Mr. William S. Lord U.S. Senate Board of Selectmen Washington, DC 20510 Town Hall - Friend Street (ATTN: Tom Burack)

Amesbury, MA 01913 Richard A. Hampe, Esq.

Senator Gordon J. Humphrey Hampe and McNicholas 1 Pillsbury Street 35 Pleasant Street Concord, NH 03301 Concord, NH 03301 (ATTN: Herb Boynton)

Thomas F. Powers, III H. Joseph Flynn, Esquire Town Manager Office of General Counsel Town of Exeter Federal Emergency Management Agency 10 Front Street 500 C Street, SW Exeter, NH 03833 Washington, DC 20472 Brentwood Board of Selectmen Paul McEachern, Esquire RFD Dalton Road Matthew T. Brock, Esquire Brentwood, NH 03833 Shaines & McEachern 25 Maplewood Avenue Gary W. Holmes, Esq.

P.O. Box 360 Holmes & Ells Portsmouth, NH 03801 47 Winnacunnet Road Hampton, NH 03842 Robert Carrigg Town Office Mr. Ed Thomas Atlantic Avenue FEMA Region 1 North Hampton, NH 03862 442 John W. McCormack PO & Courthouse Boston, MA 02109

.