ML20206B837
| ML20206B837 | |
| Person / Time | |
|---|---|
| Site: | Seabrook |
| Issue date: | 05/20/1986 |
| From: | Devincentis J PUBLIC SERVICE CO. OF NEW HAMPSHIRE |
| To: | Starostecki R NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| References | |
| (CDR-85--4), (CDR-85-00-04), SBN-1058, NUDOCS 8606190210 | |
| Download: ML20206B837 (2) | |
Text
.
- a
,A *,
SEABROOK STATION Enginaaring Offica (e I May 20, 1986 Put2c Sendce of New Hampshire S'IN-1058 T.F.
Q2.2.2 NEW HAMPSHIRE YANKEE DIVISION United States Nuclear Regulatory Commission Region 1 631 Park Avenue King of Prussia, PA 19406 Attention:
Mr. Richard W. Starostecki, Director Division of Project and Resident Programs
References:
(a) Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) Telecon of March 1,1985, V. L. Killpack, Jr. (YAEC) to Jane Grant (NRC - Region I)
(c) PSNH Letter (SBN-785), dated April 1,1985, " Interim 10CFR50.55(e) Report:
Blocked Air Hose in Vent Lines from Safety-Related Air-Operated Actuators",
J. Devincentis to R. W. Starostecki Subj ect :
Final 50.55(e) Report: Blocked Air Hose in Vent Lines from Safety-Related Air-Operated Actuators (CDR 85-00-04)
Dear Sir:
/
In Reference (b), we reported a 10CFR50.55(e) deficiency regarding blocked air hose in vent lines from safety-related air-operated actuators.
This deficiency was identified during testing of air-operated valves when the valves did not move or moved slowly in one direction or the other.
The worst case possible would have been the failure of redundant contain-ment isolation valves to close.
The corrective action, as specified in Reference (c), removal of all defective safety-related valve air hoses and replacement with hoses that were properly fabricated or with instrument tubing if the application did not require a hose, has been completed for Unit 1.
As such, this is con-sidered our final report on this item for Unit 1.
Unit 2 hoses have not yet been installed.
Very truly yours, P606190210 860520 w
PDR ADOCK 05000443 e-PDR John DeVincentis s
Director of Engineering cc: Atomic Safety and Licensing Board Service List Director, Office of Inspection and Enforcement f
United States Nuclear Regulatory Commission
,q Washington, DC 20555
/' L
- Q Seabrook Station Construction Field Office. P.O. Box 700. Seabrook, NH O3874 j
u
4 vo Dicno Curran, Esquire C0lvin A. Cann:g Normon & Weise City Manager 2001 S. Street, N.W.
City Hall j
Suite 430 126 Daniel Stredt Washington, D.C.
20009 Portsmouth, NH 03801 Sherwin E. Turk Esq.
Stephen E. Norrill, Esquire Office of the Executive Legal Director Attorney General U.S. Nuclear Regulatory Commission George Dana Bisbee, Esquire i
Tenth Floor Assistant Attorney General l
Washington, DC 20555 Office of the Attorney General 25 Capitol Street Robert A. Backus, Esquire Concord, M 03301-4397 i
114 Lowell Street P.O. Box 516 Mr. J. P. Nadeau Manchester, NH 03105 Selectmen's Office i
10 Central Road i
Philip Ahrens, Esquire Eye, NN 03870 Assistant Attorney General j
i Department of The Attorney General Mr. Angle Nachiros Statehouse Station M Chairman of the Board of Selectmen kugusta, NE 04333 Town of Newbury l
Newbury, MA 01950 l
Mrs. Sandra Gavutis Chairman, Board of Selectmen Mr. William S. Lord RFD 1 - Box 1154 Board of Selectmea Kennoington, NH 03827 Town Hall - Friend Street Amesbury, MA 01913 Carol S. Sneider, Esquire Assistant Attorney Geners!
Senator Gordon J. Humphrey Department of the Attorney General 1 Pillsbury Street One Ashburton Place, 19th Floor C'.. cord, EN 03301 Boston, MA 02108 (ATTN: Norb Boynton)
Senator Gordon J. Humphrey N. Joseph Flynn, Esquire U.S. Senate Offlee of General Counsel Washington, DC 20510 Federal meersency Management Agency g (ATTN: Tom Burack) 500 C Street, SW Washington, DC 20472 Richard A. Hampe. Esq.
Hampe and McNicholas Paul McEachern, Esquire 35 Pleasant Street Matthew T. Brock, Esquire Concord, NN 03301 Shaines & NcEachern 25 Maplewood Avenue Donald E. Chick P.O. Box 360 Town Manager Portsmouth, NN 03801 Town of Exeter 10 Front Street Cary W. Holmes, Esq.
Exeter, EN 03833 Holmes & Elle 47 Winnacunnet Road Brentwood Board of Selectmen Hampton, NH 03841 RfD Dalton Road Brentwood, NN 03833 Mr. Ed Thomas FEMA Region I Peter J. Mathews, Mayor 442 John W. McCormack PO & Courthouse City Hall Boston, MA 02109 Newburyport HA 01950 Stanley W. Knowles, Chairman Board of Selectmen P.O. Box 710 North Hampton, NH 03862 L