ML20079L793

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Westinghouse-mfg Gate Valve Position Indicators.Initially Reported on 830110.Detailed Analysis & Corrective Actions Will Be Provided by 830430
ML20079L793
Person / Time
Site: Seabrook  NextEra Energy icon.png
Issue date: 02/11/1983
From: Devincentis J
PUBLIC SERVICE CO. OF NEW HAMPSHIRE, YANKEE ATOMIC ELECTRIC CO.
To: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
10CFR-050.55E, 10CFR-50.55E, SBN-466, NUDOCS 8302230449
Download: ML20079L793 (2)


Text

.

. ,p su a swim

..i. = N m ic.:

I Companyof AUEBUC SERVICE NewHampshir e 1671 Worcester Road Framingham, Massachusetts 01701 (617) - 872- 8100 February 11, 1983 SBN-466 T.F. B7.1.2

'Jnfted States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention: Mr. Richard W. Starostecki, Director Division of Resident and Project inspection

References:

(a) Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) Telecon of January 10, 1983, H. E. Wingate (YAEC) to Eugene Kelly (NRC Region I)

Subject:

Interim 10CFR50.55(e) Report; Westinghouse EMD Cate Valve Position Indication

Dear Sir:

On January 10, 1983, a potentially reportable 10CFR50.55(e) item was reported [ Reference (b)] regarding the potential for certain Westinghouse-manufactured gate valves to indicate they are closed prior to the valve disc fully isolating flow. Should the valve stall or bind following the premature indication, the operator would have an inaccurate indication of true valve position. The reportability of this potential 10CFR50.55(e) item is still under investigation. A detailed description of this deficiency, analysis of safety implications and the corrective action taken will be reported by April 30, 1983.

This letter is being filed pursuant to the interim reporting provision of 10CFR50.55(e)(3).

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY 8302230449 83021i PDR ADOCK 05000443 ad.

S PDR John DeVincentis Project Manager AL/dsm cc: Atomic Safety and Licensing Board Service List Director of Inspection and Enforcement US Nuclear Regulatory Commission Washington, D.C. 20555 O

w ASLB SERVICE ~ LIST Philip Ahrens, Esquire Assistant Attorney General Department of the Attorney General Augusta, ME 04333 Representative Beverly Hollingworth Coastal Chamber of Commerce 209 Wir.aacunnet Road Hampton, NH 03842 William S. Jordan, III, Esquire Harmon & Weiss 1725 I Street, N.W.

Suite 506 Washing ton, DC 20006 E. Tupper Kinder, Esquire Assistant Attorney General Office of the Attorney General 208 State House Annex Concord, NH 03301 Robert A. Backus, Esquire 116 Lowell Street P.O. Box 516 Manchester, NH 03105 Edward J. McDermott , Esquire Sanders and McDermott Professional Association 408 Lafayette Road Hampton, NH 03842 Jo Ana Shotwell, Esquire Assistant Attorney General Environmental Protection Bureau Department of the Attorney General One Ashburton Place, 19th Floor Boston, MA 02108

.. . - . . ,- .