Jebraska Public Power District

"(({iff5b sfh5h^ '""

LQA8200035 December 2, 1982 Mr. Domenic B. Vassallo, Chief Operating Reactors Branch #2 Division of Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

Response to Request for Further Information on Previous Response to Generic Letter 81-04

Reference:

1) Letter, D. B. Vassallo to J. M. Pflant, dated November 8, 1982

Dear Mr. Vassallo:

This letter is in response to Reference 1.

Further information in addition to our previous response to Generic Letter 81-04 is provided below, l.

Determining Coolant Inventory Changes Refer to Attachment A for information requested on determining coolant inventory changes.

2.

Augmented Inservice Inspection NUTECil has completed a study of welds in austenitic stainless steel primary coolant piping at CNS where the SRI is used in conjunction with carbon content of the base metals to determine relative susceptibility of the welds.

This report categorizes a majority of the welds (> 3" diameter) in the Core Spray, Reactor Water Cleanup, Residual Heat Removal and Reactor Recirculation Systems in a highly susceptible region.

However, because IGSCC is unconfirmed at CNS (pending the results of analyses being performed en two cracked RWCU samples removed during 1982 outage), the SRI has not been a significant factor in selecting welds for examination.

In view of recent cracking in recirculation systems at several operating BWRs, CNS will examine a selection of welds in a loop of large bore reactor recirculation piping during the 1983 refueling outage.

Welds from all ranges of SRI will be examined, with the majority of exams focusing on welds with a SRI > 1.20 without regard to carbon content.

Results will be compared to the findings of the NUTECH study for use in determining future examinations.

00l 8212100293 821202 PDR ADOCK 05000298 P

PDR

s Mr. Domenic B. V s ulio December 2, 1982 Page 2 3.

Augmented ISI of Nonconforming Nonservice Sensitive Piping CNS considers all nonconforming austenitic stainless steel primary coolant piping to be service sensitive. Therefore, the Augmented ISI of Nonconforming Nonservice Sensitive Pipin3 is not applicable.

4.

Augmented ISI of Nonconforming Service Sen. 'tive Piping a.

CNS currently uses an ultrasonic exauination procedure developed by General Electric for detecting IGSCC indications within the counter bore area, heat af fected zone, fusion zone, weld area and base material area within two thicknesses of the weld.

This procedure has been in use at CNS since 1980.

b.

General Electric procedure MIGSCC-S752 Rev. 2

" Ultrasonic Examination of Pipe Welds for ICSCC", is available onsite for your review.

Important features of this procedure are listed below.

1.

Use of miniature size (k",

") transducers.

2.

Use of calibration standards of the same nominal diameter, material type and schedule as pipe being examined.

3.

Use of " "V" sound path to examine weld and one inch of base material on each accessible side of weld.

4.

Angulated scan motion 45 in each direction when scanning both transverse and parallel to the weld.

5.

Grinding or machining to make weld crown flush with adjoining base metal surfaces is performed where necessary to aid in detection of axial cracks.

6.

Use of graphic evaluation of examination data to assist in determination of weld and base metal thickness variations.

7.

Training of UT operators and evaluators in specific application of technique, and providing understanding of IGSCC, is a requirement.

c.

The minimum requirements for those personnel qualified to GE procedure MIGSCC-S752 Rev. 2 are as follows:

1.

All personnel performing, interpreting or evaluating ultrasonic examinations shall be qualified and certified in accordance with SNT-TC-1A (1975 Edition) including Supplement C.

2.

All personnel performing ultrasonic examinations shall be certified to at least a Level IT (traince).

The level IT classification is used by I&SE for personnel who have satisfied all the education, training and examination requirements for

Mr. D:menic B. Vcz:cIlo December 2, 1982 Page 3 s

certification as a Level I, but have not yet completed all of the work experience requirements.

Level IT's shall work.only under the immediate technical direction and supervision of a Level II or III.

A Level IT shall not conduct independently any examination, interpret any results of an examination, or write a report or examination results. Level I's shall also be used to perform ultrasonic examinations and shall work under the general technical direction and supervision of a Level II or III.

3.

All personnel assigned to interpret and evaluate results with respect to applicable codes, standards, specifications and procedures shall be certified to at least Level II.

4.

All personnel must be trained on actual weld specimens that exhibit IGSCC.

d.

CNS is examining nonconforming service sensitive piping per the guidelines set forth in General Electric's Service Information Letter (SIL) No. 117, Revision 1, March 1976.

The extent of examinations recommended by SIL No. 117, Rev. 1 is as follows:

Piping System Extent of Examination l

Recirculation Bypass 100% of welds Core Spray System 100% of welds RHR Shutdown Cooling 100% of welds in one loop Recirculation System Select welds per ASME Section XI, 1974

Edition, Summer 1975 Addenda.

Welds selected to be examined should be completed during the first 80 month period.

For the balance of plant service

lifetime, examination shall revert to the schedule in ASME Section XI.

inservice inspection of These examinations should be austenitic stainless steel conducted in accordance with the pipe runs within the reactor schedule specified in ASME Code, coolant boundary that Section XI - Subsection IWB, as operate with full coolant required by the applicable flow (RWCU) during normal categories B-F and B-J, with the reactor operation.

exception that the required examinations be completed during the first 80 month period. After the first 80 month period the examinations shall revert back to the ASME Section schedule.

Mr. D:menic B. VI: allo e 3cember 2, 1982 9

'PAge 4 1s y The inspection intervals for nonconforming service sensitive piping e.

are presented in two parts:

Part 1:

Inspections performed to date.

Part 2:

Inspection schedule for future examinations in accordance with GE SIL 117, Rev. 1.

\\

Part 1:

Refer to Attachment B for inspections performed to date.

Part 2:

System Examinations Scheduled Recirculation Bypass 1984, 1987, 1997, 2007 Cores.9 pray System 1983, 1986, 1989, 1999 RHR Shutdown Cooling 1983, 1993, 2003, 2013 connection to recirculation loops A & B Recirculation Piping Selection of welds to be examined during 1983 refueling outage based on SRI numbers.

(These inspections are abcve and beyond minimum inspections recommended in GE SIL 117, Rev. 1, in view of recent cracking in recirculation systems at several operating BWRs.)

RWCU No examinations scheduled for 1983 refueling outage.

Future examinations in accordance with ASME Section XI, 1974 w/S75 Addenda requirements, f.

Refer to Attachment C for the SRI numbers of welded joints in nonconforming service sensitive pipe.

5.

Coolant Leakage The CNS Final Safety Analysis Repert (FSAR) establishes the allowable unidentified primary coolant Icakage rate at 15 gpm. This is based, with adequate margin for contingencies, on the calculated leakage from a crack large enough to propagate rapidly. However, CNS Technical Specifications limit unidentified primary coolant leakage to 5 gpm, which is a factor of three times,more conservattve than the allowabic limit set by the FSAR.

t

Mr. Domenic B. Vserallo December 2,~1982 Page 5 Plant operating experience has indicated that norril unidentified leakage is less than.5 gpm.

The District is confident that the current limit provides sufficient margin for corrective action in the. event of a significant primary coolant leak.

Should you have any further questions regarding this response, please contact me.

Sincerely, C?f: b-J. M. Pilant Division Manager of Licensing & Quality Assurance JMP:SSF:1b 4

i O

t wy-y

+-9

  • w w

a r

<-+w-w

_.y m.

--==u=

K b [?

4

\\

l p,'

Yi ATTACHMENT A

~

ig s

O ruroasArron RcotirSito or,n N

tzax ocrectror< SvSren (1)

(2)

(3)

(4)

Di (6)

(7)

(

Type of Is Leak Time Is Control Calibra tion bocumentation Sys tem System Rate Required System Room or Testing Reference -

Operable Sensitivity To Achieve Function,al Indications During for (1)

(yes/no)

(gpm)

Sensi tivi ty After SSE (alarms)

Operation Thru (6)

(hours)

(yes/no)

(recorders)

(yes/no)

Dryvell equip.

~

and' floor integrator alarms S.P. 6.2.3.1 drain sump yes accuracy 0

yes and ye's,

S.P. 6.2.3.2.

flow 12% to 10.5% up to 22.5gpm recorders

~

recorders 10.5% for 22.5gpm to 50gpm I

Drywell equip.

3 sump indication temperature yes of leakage NA yes alarms yes M.P. 7.5.5.3 indicator only I

3 torus water 1cvel indication alarms indicators yes of leakage FA yes and yes S.P. 6.2.2.8.6 and one only recorders recorder W internal temperature indication alarms M.P. 7.5.5.2 and torus yes of leakage NA yes and yes S.P. 6.2.2.8.4 temperature only recorders S.P. 6.2.2.8.5 3 DW and one torus indication alarms S.P. 6.2.2.8.3 pressure yes of leakage NA yes and yes S.P. 6.2.2.8.7 indicator only recorders S.P. 6.2.2.8.9 Dryvell process indication radiation yes of leakage NA yes alarms yes S.P. 6.2.3.3 mon.itor only

ATTACHMENT B INSPECTIONS PERFORMED ON NONCONFORMING SERVICE SENSITIVE PIPING RWCU 21 - 6" Welds (Circum.)

1975 2/21 2 for AISI 1976 0/21 0 for AISI 1977 0/21 0 for AISI 1978 3/21 0 for AISI 1979 1/21 1 for AISI 1980 0/21 0 for AISI 1981 0/21 0 for AISI 1982 21/21 21 for AISI Core Spray 16 - 10" Welds (Circum.)

1975 16/16 0 for AISI 1976 16/16 0 for AISI 1977 0/16 0 for AISI 1978 13/16 12 for AISI 1979 0/16 0 for AISI 1980 14/16 14 for AISI 1981 1/16 1 for AISI 1982 0/16 0 for AISI Recire. 24 - 4" Welds (circum.)

1974 24/24 0 for AISI 1975 4/24 0 for AISI 1976 24/24 4 for AISI 1977 20/24 20 for AISI 1978 20/24 20 for AISI 1979 0/24 0 for AISI 1980 18/24 18 for AISI 1981 20/24 20 for AISI 1982 0/24 0 for AISI Recire.

10 - 24" Welds (Circum.)

1975 1/10 0 for AISI 1976 0/10 0 for AISI 1977 0/10 0 for AISI 1978 0/10 0 for AISI 1979 0/10 0 for AISI 1980 1/10 1 for AISI 1981 0/10 0 for AISI 1982 0/10 0 for AISI ATTACHMENT B INSPECTIONS PERFORMED ON NONCONFORMING SERVICE SENSITIVE PIPING Recirc. 50 - 12" Welds (circum.) - Safe Ends Included 1975 4/50 0 for AISI 1976 4/50 0 for AISI 197/

6/50 6 for AISI 1978 13/50 0 for AISI 1979 0/50 0 for AISI 1980 14/50 9 for AISI 1981 0/50 0 for AISI 1982 0/50 0 for AISI Recire. 30 --12" Welds (Long Seam) 1975-0/30 0 for AISI 1976 0/30 0 for AISI 1977 4/30 4 for AISI 1978 11/30 0 for AISI 1979 0/30 0 for AISI 1980 2/30 2 for AISI 1981 0/30 0 for AISI 1982 0/30 0 for AISI Recire.

38 - 28" Welds (Circum.)

1975 5/38 0 for AISI 1976 0/38 0 for AISI 1977 0/38 0 for AISI 1978 0/38 0 for AISI 1979 0/38 0 for AISI 1980 5/38 1 for AISI 1981 0/38 0 for AISI 1982 0/38 0 for AISI RHR Supply and Return - 7 Welds (20"-24") - Safe Ends Included 1975 6/7 0 for AISI 1976 3/7 0 for AISI 1977 0/7 0 for AISI i

1978 0/7 0 for AISI 1979 0/7 0 for AISI 1980 6/7 6 for AISI 1981 0/7 0 for AISI 1982 0/7 0 for AISI e -

4 ATTAC11 MENT C STRESS RULE INDEX NUMBERS FOR NONCONFORMING SERVICE SENSITIVE PIPE f

j

i I

I I

I Appendix A Stress Rule Index Evaluation Summary 8

1 8

1 1

8 1

i NEB-01-001 A.0

b

.....................................................................................................e.......................e...

5 C0RE o

. NUTECH

-- VERSION 1.0.0 --

PAGE 34 e NPPD COOPER-IG5CC OF SECIRCULATION SYSTEM 10/12/81 e

.ee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee STRESS MULE INDEX EVALUAT!aN -

SUMMARY

e

.c..oeoooooooes.ooooooooooooooeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeoseeeee***eooe**e*******eeeeeeeeee**eoooooooooe***eoeooseeeeetooo

WELD IDj-RAF-8J-2 RAF_8J-3 RAF-8J-4 RAF-8J_6 RMA-BJ-2 151 WELD TYPE SE-P P-E E-P P-5W SW-HOR PIPE SIZE 12.00 12.00 12.00 12.00 22.00 NODE NO 8

11 13 14 15 COMP TYPE TRANS ELBOWLR EL80wLR TEE 7EE 81 / 82

.50/1.00 1.00/3.25 1.00/3.25 1.00/2.40 1 00/2.40 C1 / C2 1.59/1 94 1 25/4.33 1.25/4.33 1.50/3.20 1.50/3.20 K1 / K2 1.20/1.80 1.20/1 80 1 20/1.80 1.20/1.80.

1 20/1.80

$1tPRE51 13222.45 13222.45 13222.45 13222.45 13891.79 51 (OW) 438.93 138.80 278.97 899.88 83.07 SIITHER) 1778.38 1136.55 528.97 2078.59 378.56 PM +PB 7050.15 13673.23 14128.45 15379.17 14090.90 PMeP8eQeF 33032.11 29800.13 26156.94 40932.68 27660.56 0 e F 25981.96 16126.90 12028.49 25553.51 13569.67 r

RESI ST 32000.00 32000.00 32000.00 32000.00 28000.00 YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 I

N00. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 25666000.00

'l l.

SRI,PRI

.3779

.7329

.7573

.8244

.7553 a

l SRI.5EC

.8285

.6876

.6291

.8223

.5940 5RI TOTAL 1.2064 1.4206 1.3864 1.6467 1.3493 4

9

~

M M

M M

M M

M M

M M

c

.....................e.....................*.*e.........................o..........................................o.............

5C0RE o

.. NUTECH

-- VERSION 1.0.0 --

PAGE 35

  • hPPD COOPER-ICSCC OF kECIRCULATION SYSTEM 10/12/81 *

....e e e e e e e e e e e e e e o * *

  • e o v e e e e *
  • e e e e v e * * * *
  • e e e * * * * *
  • e e o * * *
  • e e * *
  • e e e *
  • e e e c o c o o e * * * * * * * * * * * * * * * *
  • e o o e * * * * * * * * * * *
  • e e e e e e e e e e e e e e e s e e e STRESS RULE INDEX EVALUATION -

SUMMARY

e

....eeeeeeeeeeeeeeeeeeeeeeeeeeeee******************************ee*************************e**********eoeooooeseeeeeeee eeeeeooose ISI RMA-8J-2 RRG-8J-2 RRG-8J-3 RRG-8J-4 RRG-8J-6 WELD ID WELD TYPE Sw-HOR SE-P P-E t-P P-5W PIPE SIZE 12.00 12.00 12.00 12.00 12.00 NODE NO 15 24 25 27 28 COMP TYPE TEE TRANS ELBOWLR ELBOWLR TEE 81 / 82 1.00/2.40

.50/1.00 1.00/3.25 1.00/3.25 1.00/2.40 C1 / C2 1.50/3.20 1.59/1.94 1 25/4.33 1.25/4.33 1.50/3.20 K1 / K2 1.20/1 80 1.20/1.80 1.20/1.80 1.20/1 80 1.20/1.80 SitPRESI 13222.45 13222 45 13222.45 13222.45 13222.45 SI (DWI 1011 07 317.59 76.77 510.59 972.89 SI(THERI 2368.89 3368.68 1534.38 334.59 2151.74 PM e P8 15645.6?

6928.81 13471.76 14880.69 15554.15 PM.P8+0+F 43242.01 38172.56 32417.46 26447.26 41773.41 Q *F 27596 34 31243.75 18945.70 11566.57 26219.26 RESI ST 32000.00 32000.00 32000.00 32000.00 32000.00 YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 M00. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 25666000.00 SRI.PRI

.8386

.3714

.7221

.7976

.8337 SRI,5EC

.8515

.9036

.7279

.6225

.8318 SRI TOTAL 1.6902 1.2750 1.4500 1.4201

~1.6656

M rum m den tW alan M

tems tasa ty

tuus O
aa a usue enum seus
m8ss
suns m

....e.e...eee.eeee..e.........................................................................................$.....

5CaxE PACE 36 *

-- WERSION 1.0.0 --

10/12/81 e

. NUTECH NPPD COOPER-IG5CC OF RECIRCULATION SYSTEM

....o o e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e * * * * * *

  • e e e *
  • STRESS AULE INDEX EVALUATION -

SUMMARY

....ooooooooooooooseeeeeeeee*****eeeeeeeoooo*****ee**eeee*oese***eceeeeetoeooooe**eooooooeeeceeeer' ****

ISI AMA-8J-5 R M A-8 J-5 R R H-8 J-2 RRH-8J-3 RRH-8J-4 WELO 10 t

WELD TYPE SW-HDR

$w-HOR SE-P P-E E-P PIPE SIZE 22.00 12.00 12.00 12.00 12.00 NODE NO 29 29 44 45 47 COMP TYPE TEE TEE TRANS EL80WLR ELB0wLR 81 / 82 1.00/2.40 1.06/2 40

.50/1.00 1.00/3 25 1.00/3.25 C1 / C2 1.50/3.20 1.50/3.20 1.59/1.94 1.25/4.33 1.25/4.33 K1 / k2 1.20/1 80 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 5!tPRE55 13891.79 13722.45 13222.45 13222.45 13222.45 51 (DW) 418.10 1118.95 209.15 181.91 444.19 SI(THER) 759.72 2454.17 3473.26 1677.21 622.49 PM e PS 19893.84 15904.21 6820.38 13813.24 19665.04 PMeP8eQeF 31780.07 44353.10 38159.05 34350.31 28173.71 3

0+F 16866.23 28448.89 31338.68 20537.07 13508.67 RESI ST 28000.00 32000.00 32000.00 32000.00 32000.00 YIELO ST 18656.00 18656.00 18656.00 18656.00 18656.00 s

M00. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 25666000.00

_J _ _

SRI,PRI

.7983

.8525

.3656

.7404

.7861 5RI,5EC

.6413

.8637

.9050

.7507

.6502

__.~ - _.____.. _ _ ______._ _ _

i SRI TOTAL 1.4397 1.7162 1.2706 1.4911 1 4363

ammma ammme '

m.-=

=

m===

ensma-asumes amamm amano ammes.

.bmus,

mama, sumuL
mamma, mas, mmma.

summe.

mumma.

ammes O

Q

)

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee***eoeoooeseeeeeeeeeooe*****eooeeeeee***eeeeeeeeeeeeeeeeeeeeeeoo.seeeeoeoooooooooooese e

5C0RE e'

s e NUTECH

-- VERSION 1.0.0 --

PAGE 37

  • NPPD COOPER-IC5CC OF RECIRCULATION SYSTEM 10/12/81
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeev eeeeeeeeeeeeeeeeeeeee e

1 o

STRESS RULF INDEX EVALUATION -

SUMMARY

s seeeeeeeeeeeeeeeeeeeooseeeeeeeee**o*********o*****o****s e**o****eseeeeeeeeeoeooo*****eooeeeeeeeeeeeeeeeeeeeeogeeeeeeeeeeeeosoeee

')

I5I RRH-8J-6 RMA-BJ-7 RRJ-BJ-2 RRJ-8J-3 RR J-8 J-4 MELD ID s

WELD TYPE P-RED RED-CR SE-P P-E E-P 1

PIPE SIZE 12.00 28.00 12.00 12.00 12.00 NODE NO 48 49 64 65 67

. )

COMP TYPE REDUCER REDUCER TRAN5 ELBOWLR EL80WLR y

81 / B2 1.00/1.00 1.00/1.00

.50/1.00 1.00/3.25 1.00/3.25

)

C1 / C2 2 47/4.00 2.47/4.00 1.59/1.94 1.25/4.33 1.25/4.33

)

K1 / K2 1.20/1.80 1 20/1.23 1.20/1.80 1.20/1.80 1.20/1.80 SitPRES) 13222.45 19177.12 13222.45 13222.45 13222.45 o

SI (DWI 391.20 26.54 711.58 398.60 96.71

)

SItTHERI 4040.95 465.62 2098.76 1104.99 877.36 PM +PB 13613.65 14203.65 7322.81 14516.99 13543.03 s

PM+P8*Q+F 71127.47 45573.32 35107.37 31579.20 27467.38 Qo F 57513.83 31369.67 27784.57 17062.22 13924.36 RESI ST 32000.00 27000.00 32000.00 32000.00 32000.00 YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 M00. ELA.

25666000.00 25666000.00 25666000.00 4 25666000.00 25666000.00 5AlePRI

.7297

.7613

.3925

.7781

.7259 SRI,5EC 1.2790

.8340

.8542

.7010

.6562 j

=.- ----

.._.._____.3_

SRI TOTAL 2.0087 1.5953

  • 1.2467 1.4791 1.3821

,s

a.amme samme, unums wmmens unsuus I.muni s miend Lammad sammma tammes amma

.amma

amma, w

w

. sus m m===

a.-=

c

...................................o........................................o.................................*......e...........

e 500RE o

. NUTECH

-- VERSION 1.0.0 --

PAGE 38 o'

NPPD COOPER-IGSCC OF RECIRCULATION SYSTEM 10/12/81 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee***eoe**eeeeeeeee****************eeee***************eoeooooooseeooooooeseeeooseeeeeeeeeooes STRES$ RULE INDEX EVALUATION -

SUMMARY

.ee ee ee ee ee ee eee e ee *** * * *e o co c oos ee ** *e c es e ** ** ****

  • e * * *
  • e o** ** *e ceo e ooo oo o o o o s ee ee ee e* * ** eoo o o** ** eooo se ese co sec oo oo o oo o o oooose e ISI RRJ-8J-6 RMA-8J-10 RNA-8J-10 RMA-8J-10 RRK-8J-2 WELD ID e

WELD TYPE P-5W SW-HDR SW-HDR SW-HLR SE-P PIPE SIZE 12.00 12.00 22.00 22.00 12.00 NODE NO 68 69 91 91 84 COMP TYPE TEE TEE 1EE TEE TRANS 81 / 82 1.00/2.40 1 00/2.40 1.00/2.90 1.00/2 40

.50/1.00

.i C1 / C2 1.50/3.20 1.50/3.20 1.50/3.20 1.50/3.20 1.59/1.94 e

K1 / K2 1 20/1.80 1.20/1.80 1.20/1.80 1.20/1 80 1.20/1.80 5!(PRES) 13222.45 13222.45 13891.79 13891.79 13222.45 f

SI (OWI 36.33 68.06 74.57 189.04 162.85 I

SitTHER) 2610.91 2999.35 792.28 348.72 1510.47 l'

PM e PS 13309.52 13385.57 14070.52 14344.87 6774.07 i

PMoP8eceF 39027.43 41444.31 29991.39 28098.46 31128.50 Q e F 25717.91 28058.74 15920.87 13753.59 24354.43 RESI ST 32000.00 32000.00 28000.00 28000.00 32000.00 YIELD ST 18656.00 18656.00 18656.00 1865'6.00 18656.00 M00. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 25666000.00 e.

SRIePRI

.7134

.7175

.7542

.7689

.3631 SRI,5EC

.8247

.8581

.6275

.5966

.8052 SRI TOTAL 1 5381 1.5756 1.3818 1.3655 1.1683 4

I-M W

M M

Y Y

Y Y

Y Y

Y Y

Y, 5

5 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeveeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeoeoooooooooeve.oooveeeeeeeeeeee, 5C0RE o

3 e NUTECH

-- VERSION 1.0.0 --

PAGE 39

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9

STRESS RULE INDEX EVALUATION -

SUMMARY

e eeeeeeeeeeeeeeeeeeeeeeeeeee****e*****eeeeeeeee**e**eeeeeeeeeeeeeeeeeeooe***eoosseeeeee***eeeeeeeeeeeeeeeeeeoooseeeeeeeseeeeeeeoso I9 l

151 RnK-8J-3 RRK-8J-4 RRK-8J-6 RMA-8J-13 RMA-BJ-13

{

WELD 10 M

uELD TYPE P-E E-P P-5W SW-HDR SW-HDR p

PIPE SIZE

.12.00 12.00 12.00 12.00 22.00 1

l NODE ha 85 87 88 89 89 R

COMP TYPE EL80wLR ELB0blR TEE TEE TEE

'o 81 / 82 1.00/3.25 1.00/3.25 1.00/2.40 1.00/2.40 1.00/2.40 0

C1 / C2 1.25/4.33 1.25/4.33 1 50/3.20 1.50/3.20 1 50/3.20

'Q~

K1 / K2 1.20/1.80 1.20/1.80 1 20/1.80 1.20/1 80 1.20/1.80 SilPRE58 13222.45 13222.45 13222.45 13222.45 13891.79

'O SI IDWI 277.60 186 49 82.95 125.53 51.68 SIITHERI 386.63 1361.26 2196.95 2538.25 468.53 4,O Il PM + P8 19124.01 13828.10 13421.26 13523.32 14015.e6 PM.P8*QeF 25036.80 31923.27 36914.49 39122.61 27997.50 i gp Qe F 10912.79 18095.18 23493.23 25599.29 13981.84 RESI ST 32000.00 32000.00 32000.00 32000.00 28000.00 e

YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00

y M00. ELA.

25666000.00 25666000.00 25666000.00 -

25666000.00 25666000.00

V SRI,PRI

.7571

.7412

.7194

.7249

.7513 SRI,5EC

.6131

.7158

.7929

.8230

.5998

.v SRI TOTAL 1.3702 1.4570 1.5123 1.5479 1.3511

~

M m

m M

M M

M m

ya m

m m

m m

m m

m e.*..*.......e++...................***..e.................*.....*.e.**.......**...***..****...****..*..***...**....*.e...*..**..*

5C0R E e NUTECH

-- VERSION 1.0.0 --

PAGE 40

  • e NPPD COOPER-IG5CC OF RECIRCULATION SYSTEM eseeeeeeeeeeeees.eeeeeeeeee******************************.*****.e**.e**************************************.***********10/12/81
      • seee***

STRESS RULE INDEX EVALUATION - $UMMARY eeeeeeee***eeeeeeee.eete*ee*****************************.*************************************e.*********************************

I5I RMA-BJ-6 RNA-BJ-9 RMA-8J-8 RPA-BJ-2 RPA-8J-3 i

WELD ID 8

HELD TYPE HDR-CR HDR-CR P-CR SE-P P-E PIPE SI2E 22.00 22.00 28.00 28.00 28.00 NCDE NO 37 94 96 143 144 COMP TYPE TEE TEE TEE TRANS EL80WLR 81 / B2 1.00/2.43 1.00/2.43 1.00/2.43

.50/1.00 1.00/3.55 C1 / C2 1.50/3.24 1 50/3.24 1.50/3.24 1.50/1.74 1.24/4.73 K1 / k2 1.20/1.80 1.20/1.80 1.20/1.80 o 1.20/1.80 1.20/1.80 511 PRES) 13891.79 13891.79 14177.12 14047.79 14047.79 51 IDW) 452.36 155.64 530.19 411.31 405.68 SIITHER) 233.02 1115.06 578.49 102.20 155.73 PM + PB 14991.48 14270.15 15466.00 7435.20 15486.86 PM.P B.Q.F 29004.00 32418.89 31987.26 26822.17 25633.38 0e F 14012.52 18148.74 16521.26 19386.97 10146.51 RESI ST 28000.00 28000.00 27000.00 27000.00 27000.00' YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 MOD. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 25666000.00 SRI.PRI

.8036

.7649

.8290

.3985

.8301 SRI.S.*

.6003

.6594

.6218

.6628

.5308

==_...._.___._....

SRI TOTAL 1.4039 1.4243 1.4508 1.0613 1.3609

th sm,a-samme umas iw tasme 5C0RE

-- VERSION 1.0.0 --

PACE 41.

e

. NUTECH NPPD COOPER-IGSCC OF RECIRCULATION SYSTEM 10/12/81

  • STRESS RULE INDEX EVALUATION -

SUMMARY

t ISI RPA-8J-4 RPA-8J-5 RPA-8J-7 RPA-8J-13 RPA-8J-15 WELD 10 WELD TYPE P-E P-T T-P P-E F-V PIPE SIZE 28.00 28.00 28.00 28.00 28.00 NODE h0 146 147 171 173 175 COMP TYPE EL80hLR TEE TEE EL80WLR EL80WLR 81 / B2 1 00/3 55 1.00/2.60 1.00/2.60 1.00/3.55 1.00/3.55 C1 / C2 1.24/4.73 1.50/3 46 1.50/3.46 1.24/4.73 1.24/4.73 K1 / K2 1 20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 5!! PRES) 14047.79 14047.79 14047.79 14047.79 14047.79 SI (OWI 433.94 245.56 153.99 160.36 100.33 5!(THER) 416.82 507.87 753.50 238.74 148.06 PM. P8 15587.13 19685.58 14447.74 14616.64 14403.69 i

PM.P8.Q.F 28096.83 29982.56 30942.86 24251.54 22968.46 e

I Q. F 12509.70 15296.98 16495.12 9634.91 8564.78 f

RESI ST 27000.00 27000.00 27000.00 27000.00 27000.00 YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 MOD. ELA.

25666000.00 25666000.00 25666000.00

,25666000.00 25666000.00 SRI PRI

.8355

.7872

.7744

.7835

.7721 SR1,5EC

.5645

.6043

.6215

.5234'

.5082 i

5RI TOTAL 1.4000 1.3915 1.3959 1.3069 1.2802

m p

tunsm8 theast h

M

... c.........e.ee......................................No..... M

.............e

. NUTECH

.'C 0 R E

-- VE45!0N 1.0.0 --

o NPPD COOPER-PAGE 42 +

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eveeooooooeeeeeeeeeeee*IGSCC OF RECIRCULATION SYSTEM 10/12/81- *

          • eeeeeeeeooeveeeeeeeeeeeeeeeetoooseeoeoooooooooseesteeeeeeeeeeooevo.

STRESS RULE e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e o o o * * * * *

  • e e e e e e e e e e e e e e e e e * *I h0 E X E%ALUATION -

SUMMARY

  • * * * * * * * *
  • e o o o s e s e e o o o s e e o o o o o e s e e e e ISI RPA-8J-17 RPA-8J-23 RPA-8J-24 RPA-8J-25 RPA-BJ-27A WELD ID i

WELD TYPE Y-P P-E E-PUMP P-PUMP kOL-P i

g PIPE SIZE 28.00 28.00 28.00 28.00 4.00 h00E NO 176 178 180 181 139 O

COMP TYPE TRANS EL80WSR EL80W5R TRANS TEE p

81 / 82

.50/1.00 1.00/4.65 1.00/4.65

.50/1.00 1.00/2.43 O

C1 / C2 1.50/1.74 1.47/6.20 1.47/6.20 1.48/1.71 1.50/3.24

()

K1 / K2 1.20/1.80 1.20/1.80 1 20/1.80 1.20/1.80 1.20/1.80 SItPRESI 14047.79 14047.79 14047.79 14177.12 8505.93 C

SI (OWS 213.24 251.98 163.23 2566.42 1655.05 qs SIITHER) 139.26 216.83 71.58 332.71 8593.50 PM e PB 7237.14 15219.21 14806.64 9654.98 12529.31 O

PMeP B +QeF 26317.26 29945.58 27334.75 34045.34 75104.15 g

0+F 19080~12 19726 37 12528 11 24390.36 62574.85 RESI ST 27000.00 27000.00 27000.00 27000.00 45000.00 V

VIELO ST 18656.00 18656.00 18656.00 18656.00 27500.00 gj M00. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 27931000.00

%s SRI.PRI

.3879

.8158

.7937

.5175

.4556

,v SRIoSEC .6584

.5962

.5648

.7343 1.2905 v

SRI TOTAL 1 0463 1.412O 1.3585 1.2518 1.7961 v

'e e'

Um E M

M M

M IM

d M

M g

g g

g g

g

............................................................................e......................ee............................e 5 C0RE PAGE 43 e VERSION 1.0.0 --

. NuTECH NPPD COOPER-IGSCC OF RECIRCULATION SYSTEM '

10/12/81 *

..e ee ee ee ee e e ee e e ee e e ee ee e eeee ee e e e ee ee eo oo oe ee ee e *

  • e e e ee e * * * ** e* *** *
  • e et e e ** *o ** ** *
  • ese*
  • e e**es e ov eeee e e ee e e o ooo e

STRESS RULE INDEX EVALUATION -

SUMMARY

eeeeeeooooooese

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeoooo**eooe**eeeeee******ese*********************************o**eoeooooooseeeeee ISI RPA-8J-27 RPA-BJ-27 RPA-8J-28 RPA-8J-29 RPA-BJ-30 WELD 10 t

HELD TYPE SPC BPC P-V V-E E-P PIPE SI2E 28.00 28.00 28.00 28.00 28.00 NODE ha 129 192 124 123 121 COMP TYPE TEE TEE TRANS ELBOWLR EL80mLR 81 / 82 1.00/2.43 1 00/2.43

.50/1.00 1.00/3.33 1.00/3.33 C1 / C2 1.50/3.24 1.5C/3.24 1.48/1.71 1.24/4.44 1.24/4.44 K1 / K2 1.20/1 80 1.20/1.80 1.20/1.50 1.20/1.80 1.20/1.80 SItPRESI 14177.12 14177.12 14177.12 14177.12 14177.12 t'

5I (DW) 138.12 132.15 133.08 136.03 69.13 SI(THER) 277.70 335.75 290.18 386.18 178.21 PM + PB 14512.89 14498.37 7221.64 19630.15 14407.36 PMeP8eQeF 27944.85 28248.71 26427.86 25247.62 23050.61 0e F 13431.96 13750.34 19206.23 10617.47 8643.25 RESI ST 27000.00 27000.00 27000.00 27000.00 27000.00 YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 M00. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 25666000.00 g

__.1__.....,._..___.__..

SRI.PRI

.7779

.7771

.3871

.7842

.7723 SRI 5EC

.5777

.5822

.6602

.5375

.5093 SRI TOTAL 1.3556 1.3594 1.0473 1.3217 1.2815

'O

LM L K JWG LF14 LM M

M M

M M

M M

M M

M M

M eseeeeeeeeeeeeeeeoeooooooeeeeeeeeeece*******eceoce****eeeeee940*eoooe0000eocoooooseeeeeeeeeeeeeeeeeeeeeeeeeeooeeeeeeeeeoeoooossee e

5C0RE e

o NUTECH

-- VERSION 1.0.0 --

PAGE 44

  • e NPPD C00PER-!G5CC OF RECIRCULATION SYSTEM 10 eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee*****eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee/12/81 eeeeeees e

STRESS RULE INDEX EVALUATION -

SUMMARY

e oceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee***eseeooseeeeeeeeeeeeeeeee****eoeoseeeveeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeoesee 1

ISI RPA-8J-27L RPA-8J-27L RPA-8J-36 RPA-8J-38 RPA-8J-27K WELD ID

.3 e

kELD TYPE BPC tPC P-T P-T WOL-P 4.

PIPE SIZE 28.00 23.00 28.00 24.00 4.00 NODE NO 119 119 115 111 119 COMP TYPE TEE TEE TEE TEE TEE

=.

_=. _.- __.__.

81 / B2 1.00/2.43 1.00/2.43 1.00/2.43 1.00/2.43 1.00/2.43 C1 / C2 1.50/3.24 1.50/3.24 1.50/3.24 1.50/3.24 1.50/3.24 K1 / K2 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1 80 1.20/1.80 SitPRE51 14177.12 19177.12 14177.12 13153.72 8505.93 SI (Dwl 106.73 115.43 369.68 0.00 2208.11 SitTJER3 159.68 110.99 259.77 1550.42 8798.25 PM + PB 19436.58 14457.71 15075.81 13753.72 13873.79 PMeP8e0*F 27073.12 26839.78 29191.29 33802.39 79525.47 0*F 12636.54 12382.07 14115.48 20048.67 65651.68 RESI ST 27000.00 27000.00 27000.00 27500.00 45000.00 YIELD ST 18656.00 18656.00 18656.00 18656.00 27500.00 M00. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 27931000.00 SRI,PRI

.7738

.7750

.8081

.7372

.5045

$RI,$EC

.5663

.5627

.5875

.6794 1.3274 r

SRI TOTAL 1.3402 1.3377 1.3956 1.4166 1.8319

tm m __..sme tsee LWund M

M

'm M

3sE M

M Amt 235.

350 Annt m

m eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee***eeeeeeeeee****ee***eeeee**eeeeeeeeeeeeoooseee**eeeeeeeeeeeeeeeeeeeeeeeooeeeeoooooo 5C0R E e

7 e NUTECH

-- VERSION 1 0.0 --

PACE 45

  • NPPD COOPER-ICSCC OF RECIRCULATION SYSTEM 10/12/81 e e ee ee ee ee ee ee eee e e e e e ee e e e e eee ee eee ee ee e e e e ee e* **e e e e e e ee eee e ee ee e e e e e eee e e e e eeee ee e e ee eee eee eeee ee eeee ee eeee e eeeee eeeee e eeeeeeee 3

e STRESS RULE INDEX EVALUATION -

SUMMARY

e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeooe*********eeeeeo**ee++eeeeeeeeeeeeeee**eeeeeeeooooe**eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 7

ISI RP A-B J-2 7 8 RPA-8J-271 RPA-SJ-27H RPA-8J-27F RPA-BJ-27E WELD 10 e

7 wELO TYPE E-P P-E P-v P-T P-T 3

PIPE SIZE 4.00 4.00 4.00 4.00 4.00 l

h0DE ha 1321 132 133 134 1361 D

COMP TYPE ELBOWLR ELB0hLR TRANS TEE TEE 9

81 / 82 1.00/2.43 1.00/2.43

.50/1.00 1.00/1.'69 1.00/1.69

  • ,a C1 / C2 1.27/3.24 1.27/3.24 1.76/2.10 1.50/2.26 1.50/2.26
)

K1 / K2 1 20/1.80 1.20/1.80 1.20/1.80 1.20/1 80 1.20/1.80 51(PRE 55 8535.93 8505.93 8505.93 8505.93 8505.93 0

51 (DWB 331.01

'331 01 2340.59 943 29 0.00 g

51(THERI 740.16 4498.18 6352.91 10316.00 0.00 PM + P8 0310.75 9310.75 6593.56 10102.58 8505.93 f.J PMeP8eQeF 19168.74 41098.02 50798.86 61049.65 15310.68 oe F 9658.00 31767.27 44205.31 50947.07 6804.75 NESI ST 45000.00 45000.00 45000.00 45000.00 45000.00

.)

YIELD ST 27500.00 27500.00 27500.00 27500.00 27500.00 "f

MOD. ELA.

27931000.00 27931000.00 27931000.00,, 27931000.00 27931000.00 SRI.PRI

.3186

.3386

.2398

.3674

.3093 l

SRI,5EC

.6581

.9211 1 0701 1.1510

.6214 SRI TOTAL 9966 1.2597 1.3099 1.5183

.9307

N

'M M

'M

'M Y

5 Y

Y Y

EY Y

5 5

u eeeeeeeeeeeeee**eoeeeeeeeeee*****ee************e***eee******************************o****************eeeeeeeee*****eeeo*eeeeoo**e.

$C0R E 3

  • NUTECH

-- VERSION 1.0.0 --

PAGE 46 e e

NPPD COOPER-IG5CC OF RECIRCULATION SYSTEM 10 e

e e e ee ee e e ee e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e ee e e e e e e e e e e e e e e e e e e e eeeeeeees

)

e STRESS RULE INDEX EVALUATION.

SUMMARY

o e ee ee ee ee eeee eee eeeeeeeeeeeeeeeee* ***** ** eooooo **ee e** ******* ** *e eeee eeee e**eeeee eeeeee eoo oooeeeeeeeeoeooooooee seeo eooooeeeeeeeee ISI RPA-BJ-270 RPA-BJ-27C RPA-8J-278 RMB-BJ-1 RMB-BJ-14 WELD ID

'I WELD TYPE P-T P-E E-P C-CAP C-CAP

.)

PIPE SIZE 4.00 4.00 4.00 22.00 22.00 NODE NO 136 138 1381

's COMP TYPE TEE ELB0hLR EL80WLR CPIPE CPIPE 81 / 82 1.00/1 69 1.00/2.43 1.00/2.43 1.00/1 13 1.00/1.13 n

CL / C2 1.50/2.26 1.27/3.24 1.2T/3.24 1.03/1.50 1.03/1.50

's K1 / K2 1.20/1.80 1.20/1.80 1.20/1 80 1.20/1.80 1.20/1.80 SIIPRESI 8505.93 8505.93 8505.93 13891.79 13891.79

)

SI (DW) 7.05 468.12 468.12 0.00 0.00

' s

$ltTHERI 11289.85 3367.23 3510.88 0.00 0.00 PM

  • PB 8517.88 9644 11 9644.11 13891.79 13891.79 i n PMePB+Q+F 61202.43 35298.66 36136.90 17172.87 17172.87 l

0+ F 52684.56 25654.55 26492.79 3281 08 3281.08 RESI ST 45000.00 45000.00 45000.00 28000.00 28000.00 YIELD ST 27500.00 27500.00 18656.00 18656.00 18656.00 M00. ELA.

27931000.00 27911000.00 25666000.00 "25666000.00 25666000.00 j

SRI PRI

.3097

.3507

.5169

.7446

.7446 SRI,$EC 1 1718

.8476 1.0215

.4469

.4469 SRI TOTAL 1.4816 1.1983 1.5384 1.1916 1.1916 4,

e

M

.BMa m

m M

M M

M 4

m M

M m

M M

M M

e 5C0RE

  1. NUTECH

-- VER$10N 1.0.0 --

PACE 47.

e NPPO COOPER-IGSCC OF RECIRCULATION SYSTEM 10/12/81.

e STRESS RULE INDEX EVALUATION -

SUMMARY

ec.........................................***...*......*.....................................................................'...

ISI RRE-8J-2 RRE-8J-3 RRE-8J-4 RRE-8J-6 RMS-8J-13 WELD ID WELD TYPE SE-P P-E P-E P-5W SW-HDR PIPE SIZE 12.00 12.00 12.00 12.00 12.00 NODE NO 178 181 183 184 185 COMP TYPE TRAN5 ELBOWLR ELBOWLR TEE TEE 81 / 82

.50/1 00 1.00/3.25 1 00/3.25 1.00/2.40 1.00/2.40 C1 / C2 1 59/1.94 1.25/4.33 1.25/4.33 1.50/3.20 1.50/3.20 K1 / K2 1.20/1.80 1 20/1.80 1.20/1.80 1 20/1.80 1 20/1.80 51tPRE53 13222.45 13222.45 13222.45 13222.45 13222.45 51 (DWI 242.76 219.20 253.23 328.92 190.15

$!ITHERI 1640.15 943 86 495.31 T:150.44 2451.33 PM. P8 6853.98 13934.36 14044.86 13531.42 13678.17.

PM.P8.Q.F 31861.92 28924.93 25693.94 36911.34 38994.27 Q *F 25007.94 19990.57 11649.08 23379.92 25316.10 RESI ST 32000.00 32000.00 32000.00 32000.00 32000.00 YlELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 M00. ELA.

25666000.00 25666000.00 25666000.00

,,25666000.00 25666000.00 SR!,PRI

.3674

.7469

.7528

.7253

.7332 SRI 5EC

.8145

.6714

.6237

.7913

.8789 SRI TOTAL 1 1819 1.4183 1.3765 1.5166 1.5521

m e

amme Amam8 meue Amme man 6 M

M M

M M

......... e....................................................e.................................................................

5C0RE

  • NUTECH o

-- VERSION 1.0.0 --

PAGE 48.

NPPD COOP SYSTEM eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee************ER-IG5CC OF SECIRCULATIONeeee*****eee 10 e

o eeeeeeeee STRESS RutE INDEX EVALUATION

.eeeeeeeooeeeeeeeeeeeeeeeeeeeeee***ee******eeeeeeeeeeoseeeeeeeeeeeeeeeeeeeeee*$UMMARY e

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees ISI RM8-8J-13 RRD-8J-2 RRD-8J-3 RRD-8J-4 RRD-8J-6 WELD 10 t

WELD TYPE SW-HDR SE-P P-E P-E P-5W PIPE SilE 22.00 12.00 12.00 12.00 12.00 NODE NO 185 194 195 197 198 COMP TYPE TEE TAANS EL80WLR EL80WLR

' TEE i

4 I

81 / 82 1.00/2.40

.50/1 00 1.00/3.25 1.00/3.25 1.00/2.40 C1 / C2 1.50/3.20 1,59/1,94 1,25/i 31 lel)/is])

1 90/J 10 PI / Pt l e t ri/ l 9 tt

1. / ts/ 8.e s s e s u/ t. a tt 4.40/1,a0 1.20/1.00 51(PRE 51 13891.79 13222.45 13222.45 13222.45 13222.45 SI (DW) 54.43 537.36 443.04 84.43 79.73 5!!THERI 452.07 2561.43 1262.04 417.23 2219.40 PM e PS 14022.25 7148.59 14661.30 13496.64 13413.55 PM+P8*Qef 27918.63 36116.77 33149.59 23769.62 37025.15 0+F 13896.38 28968.19 18488.29 10272.98 23611.60 i

Rest ST 28000.00 32000.00 32000.00 32000.00 32000.00 I

YlELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 M00. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 25666000.00 SRioPRI

.7516

.3832

.7859

.7234

.7190 SRIe5EC

.5986

.8711

.7214

.6040

.7946 SRI TOTAL 1 3502 1.2543 1.5073 1.3275 1.5136

8m amme

>==

m amme ans&

Anna mum hast m

Jusst, amL M

Anang M

amW.

SauS SunO haud.

P O

O esseeeeeeeeeeeeeeeeeeeeoceeeeeeeeeeeeeeee***eoo**eeeeee**eceeeeoooeteeeoooooooseeeeeeoseeeeeeeeeeeeeooooooeeeeeeeeeeeeeeeeeeeeeee e

5C08 E o.

o NUTECH

-- VERSION 1.0.0 --

PAGE 49 e e

NPPD COOPER-ICSCC SYSTEM 10 e

eeeeeeeeeeeeeeeeee******eeeeeeeeeeeeeeeeeeee******eeeee**eeee*OF RECIRCULATION *

  • o * *
  • e s e e e e e e *
  • eeeeeeee e

STRE55 RULE INDEX EVALUATION -

SUMMARY

e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

!$1 RM8-BJ-10 RM8-8J-10 RAC-8J-2 RRC-8J-3 RRC-8J-4 WELD 10 e

HELD TYPE SW-HOR SW-HDR SE-P P-E E-P PIPE SIZE 12.00 22.00 12 00 12.00 12.00 N00E NO 199 199 214 215 217 COMP TYPE TEE TEE TRANS EL80WLR EL80mLR 81 / 82 1 00/2.40 1.00/2.40

.50/1.00 1.00/3.25 1.00/3.25 C1 / C2 1.50/3.20 1.50/3.20 1.59/1.94 1.25/4.33 1.25/4.33 K1 / K2 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 SI(PRESI 13222.45 13891 79 13222.45 13222.45 13222.45 SI (DWI 103.76 90.83 413.40 168.32 355.31 SI(THERI 2520.42 821.84 3310.14 1635.55 585.75 PM e P8 13471.13 14109.49 7024.62 13769.10 14376.39 PMeP8eQeF 38894.78 30254.94 38303.00 33919.69 27194.57 0+F 25423.65 16145.44 31278.37 20150.59 12818.18 RESI ST 32000.00 28000.00 32000.00 32000.00 32000.00 YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 i

M00. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 25666000.00 j-('

SRI PRI

.7221

.7563

.3765

.7381

.7706 SRI,$EC

.8205

.6308

.9041

.7451

.6404 3

SRI TOTAL 1.5426 1.3871 1.2807 i.4832 1.4110 4

M IM.

ISMS M

M M

M M

M

-M N

M M

M k

...*......*.*..*........**.**..*......**....**....*...*.....*.*.....*.**.e......+.......**......*..*......*.....*.e..........*...

e 5C0RE

  • NUTECH

-- VERSION 1.0.0 --

PACE 50

  • NPPD COOPER-IGSCC OF SEC SYSTEM e e e e e e e e e e e. * *
  • e e e e e e * * * * * * * * * * * * * * * * * * * *. * * * * * * * * *. * * * * * * * * * * * * * * * * *I R C U L A T I O e

STRESS RULE INDEX EVALUATION -

  • .ooe***eteeee****************.***.*****************************************.

SUMMARY

.********$e**.****.******.******..o***********ooo***

I5I RRC-8J-6 RM8-BJ-7 RMS,8J-7 RM8-8J-9 RM8-8J-6 WELO ID I

WELD TYPE P-RED REO-CR RED-CR HDR-CA HOR-CR i

PIPE SIZE 12.00 28.00 28.00 22.00 22.00 NODE NO 218 219 219 207 272 COMP TYPE REDUCER REDUCER TEE TEE TEE q

B1 / 82 1.00/1.00 1.00/1.00 1.00/2.43 1.00/2.43 1.00/2.43 I

C1 / C2 2.47/4.00 2.47/4.00 1.50/3.24 1.50/3.24 1.50/3.24 i

K1 / K2 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 51(PRE 53 13222.45 14177.12 14177.12 13891.79 13891.79 SI (0WI 304.25 17.07 17.07 162.32 458.65

+

3 SI(THERI 4202.89 484.66 484.66 425.90 1092.48 PM

  • PB 13526.70 14194.18 14218.60 14286.39 15006.75 PM.P8.Q.F 71667.81 45642 27 28446.04 28437.09 34054.99 0+F

'58191.11 31448.09 14227.44 14150.71 19048.24 RESI ST 32000.00 27000.00 27000.00 28000.00 28C30.00 YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 MOD. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 25666000.00

~.

SRIePRI

.7251

.7608

.7621

.7658

.8044 SRI,5EC 1.2880

.8351

.5891

.6023

.6722 i

SRI TOTAL 2.0130 1.5960 1.3512 1.3680 1.4766

.am-se

..w m

m umum

. amens

.amme a mme.

.mmme

.amme m

ammuni

.mmmes

.mmme amma h

.o.*..........*.e.........*...............***...***.**...**....*.e..*.*....*...**.e.........*.e.**..**......*...*...............e e

5C0RE o

o NuTECH

-- VERSION 1.0.0 --

PACE 51

  • esee**ee.o**o******.e***********.*****.o*********...***.**********************************.******.***********************o**eeee o

STRESS RutE INDEX EVALUATION -

SUMMARY

e

.seeeoceee**eeeeee*ooooesse**.***************.*********************.********.************.*******.**********ooe****ooe.ee.cosee.o 8

I5I RP8-8J-42 RR8-8J-2 RR8-8J-3 RR8-8J-4 RR8-8J-6 WELD 10 e

s WELD TYPE P-CR SE-P P-E P-E P-5W i.

PIPE SIZE 28.00 12.00 12.00 12.00 12.00 NODE NO 277 234 235 237 238 COMP TYPE TEE TRANS EL80dLR ELBOWLR TEE 81 / B2 1.00/2.43

.50/1.00 1.00/3.25 1.00/3.25 1.00/2.40 it C1 / C2 1.50/3.24 1.59/1.94 1.25/4.33 1.25/4.33 1.50/3.20 K1 / K2 1.20/1.80 1.20/1.80 1 20/1.80 1.20/1.80 1.20/1.80 511 PRE 55 14177.12 13222.45 13222.45 13222.45 13222.45 N

SI IDW) 502.84 1157.77 91.58 467.27 953.36 SitTHERI 636.74 2570 15 1292.98 823.29 2698.59 PM. PB 15399.51 7759.00 13519.86 14740 00 15507.34

6 PM+P8+0*F 32167.53 38318.32 30651.34 29918.72 44806.54 0
  • F 16768.01 30547.32 17t;1.48 15178.71 29299.20 3

RESI ST 27000.00 32000.00 32000.00 32000.00 32000.00 3

YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 l.

M00. ELA.

25666000.00 25666000.00 25666000.00

,,25666000.00 25666000.00

__ a ______ _ _ __________ _ ___ ____

f 5RI PRI

.8254

.4169

.7247

.7901

.8312 5RI,5EC

.6254

.8937

.7020

.6741

.8759 SRI TOTAL 1.4508 1.3101

,1.4267 1.4642 1.7071 i

e

m m _. m m

m m

m M

M M

M M

M Mi Mi M

M M:

............ee...................o...............................................................................................

5C0R E o

. NUT ECH

-- VERSION 1. 0. 0 -

PAGE 52 o'

NPPD COOPER-IG5CC OF EECIRCULATION SYSTEM 10/12/81 *

.ee ee ee ee ee ee ee e e ee e e ee e ee e eee ee ee e ee ee **e e e+ + e oo ** *

  • e * ** *
  • e o ** eo * *o * * ** * * * ** ** * * ** ** ** ** * *** **eeoe o ooo oo oo oos ee e ee ee e ee e ee e ee eo o STRESS ROLE INDEX EWALUATION -

SUMMARY

e

.es oo os ee ee e e ee e es e ee ee e ee e e** *** ** *o * * * ** * ** ** ** * * * * * * ** *** * ** ee o o o o o ooo o s e e ee e* *e oe o c eeee* * * * *e oo * * ** ** e e c o c e oe oo oooo s e eee eeee e ISI RM8-8J-5 RM8-8J-5 RMS-8J-5 RRA-8J-2 RRA-8J-3 WELD ID i

WELD TYPE SW-HDR SW-HDR SW-HDR SE-P P-E PIPE SIZE 12.00 22.00 22.00

' 12.00 12.00 NODE NO 239 269 269 254 255 COMP TYPE TEE TEE TEE TRANS EL80WLR

... _ _ - -.,... ~. _

81 / 82 1.00/2.40 1.00/2.40 1.00/2.40

.50/1.00 1.00/3.25 l

C1 / C2 1.50/3.20 1.50/3.20 1.50/3.20 1.59/1.94 1.25/4.33 K1 / K2 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 SIIPRE53 13222.45 13891.79 13891.79 13222.45 13222.45 SI IDWI 1079.35 215.07 541.79 411.20 67.33 SIITHER) 3099.38 429.93 748.07 1334.37

.685.24 PM + PB 15809.32 14407.24 15190.29 7022.42 13441.11 PMeP8+0+F 47836.68 28715.25 32424.54 31381.34 25725.33 0 +F 32027.36 14308.01 17234.25 24358.92 12284.22 RESI ST 32000.00 28000.00 28000.00 32000.00 32000.00 YIELD ST 18656e00 18656.00 18656.00 18656.00 18656.00 MOD. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 25666000.00

..~....._ _ _ -....__....

SRI,PRI

.8474

.7723

.8142

.3764

.7205 SRI.5EC

.9148

.6045

.6463

.8053

.6327

.. ~...._ _.

SRI TOTAL 1.7622 1.3768 1 4605 1.1817 1 3532

M end mA W

M M

M M

M eumma' M

M

.amma m

samus m

m e ee e e ee e e e e e e e e e eoo o oo o o o o seee e ee e e ee * * * *

  • e o o o e *e e e e e *
  • e e e e e e e e ** e e* * **
  • e e e e e e e e* ** ** oo e e

5C0RE e

- VERSION 1.0.0 --

PAGE 53

  • e NUTECH NPPD COOPER-IGSCC OF RECIRCULATION SYSTEM 10/12/81
  • j e

I eeseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeee***********eeeee********eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee STRESS ROLE INDEX EVALUATION -

SUMMARY

,e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeceeeeeeeeeeeee****eeeeeeeeeeeeeooeoeeeeeeeeeeeeeeeeeeeeeee************eseeeeeeesteeoooooooseeeeeee, I5I RRA-BJ-4 RRA-8J-6 RMS-BJ-2 RMS-8J-2 P.M S-8 J-1 WELD 10 WELD TYPE P-E P-5W SW-HDR SW-HDR C-CAP PIPE SIZE 12.00 12.00 12.00 22.00 22.00 NODE ha 257 258 259 259 COMP TYPE EL80WLR TEE TEE TEE CPIPE 81 / B2 1.00/3.25 1.00/2 40 1.00/2.40 1.00/2.40 1.00/1 13 C1 / C2 1.2I/4.33 1.50/3.20 1.50/3.20 1.50/3.20 1.03/1.50 K1 / K2 1 20/1.80 1.20/1.80 1.20/1.80 1.20/1 80 1.20/1.80 SIIPRESS 13222.45 13222.45 13222.45 13891.79 13891.79 51 IDWI 310.10 872 44 984.18 159.34 0.00 SIITHERI 1966.39 2480.91 2871.47 516.37 0.00 PM e PB 14229.54 15313.42 15581.22 14273.69 13891.79 PMePBeQeF 33706.17 43089.05 45978.26 28891.96 17172.87 0 e F

'19476.63 27775.62 30397.04 14618.27 3281.08 f

RESI ST 32000.00 32000.00 32000.00 28000.00 28000.00 5

YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 MOD. ELA.

25666000.00 25666000.00 25666000.00 25666000.00 25666000.00 SRI.PRI

.7627

. 8208

.8352

.7651

.7446 SRI,$EC

.7355

.8541

.8915

.6089

.4469 SRI TOTAL 1.4982 1.6749 1.7267 1.3740 1.1916

l eds aus a

fama m

m m

m m

m m

m

.m m

yw rams e................................................................................................................................

e 5C0RE i

e NUTECH

-- VERSION 1. 0. 0 -

PAGE 54

  • l' e

NPPD COOPER-IG5CC OF RECIRCULATION SYSTEM 10/12/81.

e................................................................................................................................

l e

STRESS ROLE INDEX EWALUATION -

SUMMARY

4..................

ISI RMB-BJ-14 R P 8-8 J-2 AP8-BJ-3 RP8-BJ-4 RP8-8J-5 WELD ID i

WELD TYPE C-CAP SE-P P-E P-E P-P i

PIPE SIZE 22.00 28.00 28.00 28.00 28.00 NODE NO 324 325 327 328 COMP TYPE CPIPE TRAN5 EL80WLR EL80WLR PIPE 81 / B2 1.00/1 13

.50/1.00 1.00/3.55 1.00/3.55

.50/1.00 C1 / C2 1.03/1.50 1.50/1.74 1.24/4.73 1.24/4.73 1.10/1.00 K1 / K2 1 20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 1 20/1.80 SI(PRESI 13891.79 14047.79 14047.79 19047.79 14047.79 SI (DWI 0.00 480.57 473.75 475.85 171.45 SIITHERI c.00 379.35 339.19 164.44 88.78 PM + PS 13891.79 7504.47 15728.33 15735.79 7195.35 PM+P8 0.F 17172.87 27908.57 27774.83 26304.97 19011.49 0+F 3281.08 20404.10 12046.51 10569.18 11816.15 RESI ST 28000.00 27000.00 27000.00 27000.00

'27000.00 YIELO ST 18656.00 18656.00 18656.00 18656.00' 18656.00 M00. ELA.

25666000.00 25666000.00 25666000.00

,,25666000.00 25666000.00

_ _ _ _ _ _...,. ~.. _ _

SRI,PRI

.7446

.4023

.8431

.8435

.3857 SRI.5EC

.4469

.6773

.5579

.5368

.5546

~ !

SRI TOTAL 1.1916 1.0796 1.4010 1.3803

.9403

M Y

Y 5

N Y

Y Y

Y 5

5 M

Y lM N

N eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

e 5C0RE e

e NUTECH

-- VERSION 1.0.0 --

PAGE 55 e e

NPPO C00PER-IG5CC OF RECIRCULATION SYSTEM 10/12/81 e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee e

STRES5 R6LE Ih0EX EVALUATION -

SUMMARY

e e ee ee ee ee ee ee eee eee e eee eee eee e ee e e* *e e* *** *es e * ** * * * ** e s ee e ee e* ** *e e* **e s ee ee** ** *e se ** e e e e ee * *** ** **et ee ee e e e ee eee e eese o e oo te oe o i

I5I RP8-8J-6 RPB-BJ-10 RP8-8J-12 RP8-8J-14 RP8-8J-20 WELO 10 WELO TYPE P-P P-E E-V V-P P-E PIPE SIZE 28.00 28.00 28.00 28.00 28.00 N00E NO 3281 329 331 332 334 COMP TYPE PIPE EL80hLR ELBOWLR TRAN5 ELBOW 5R 81 / 82

.50/1.00 1.00/3.55 1.C0/3.55

.50/1.00 1.00/4.65 C1 / C2 1.10/1.00 1.24/4.73 1.24/4.73 1.50/1.74 1.47/6.20 K1 / K2 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1 80 1.20/1.80 5IIPRES) 14047.79 14047.79 14047.79 14047.79 14047.79 SI (DWI 171.45 191.23 238.75 188.68 207.80 SitTHERI 88.78 89.19 235.51 217.01 211.21 PM e P8 7195.35 14726.15 14894.73 7212.57 15013.84 PMeP8eQeF 19011.49 23241.,21 24891.53 26484.06 29389.97 0 e F 11816.15 8515.06 9996.80 19271.49 14376.13 RESI ST 27000.00 27000.00 27000.00 27000.00 27000.00 I'

YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 MOD. ELA.

25666000.00 25666000.00 25666000.00

'25666000.00 25666000.00 SRIePRI

.3857

.7894

.7984

.3866

.8048 SRie5EC

.5546

.5074

.5286

.6611

.5912 SRI TOTAL

.9403 1.2968 1.3270 1.0477 1.3960

M M,M rn M

5 5

5 5

5 5C0RE

. NUTECH

-- VERSION 1.0.0 --

PAGE 56

  • NPPD COOPER-IG5CC OF RECIRCULATION SYSTEn

......................................................................................................................10/12/81 STRESS RULE IhDEX EVALUATION -

SUMMARY

e............................................................................................................................,....

151 RP8-BJ-21 RP8-8J-24 RPB-8J-25A RP8-8J-25 RP8-8J-25 l

WELO lo o

f kELD TYPE E-PUMP P-PUNP P-WOL P-WOL P-WOL PIPE SIZE 28.00 28.00 4.00 28.00 28.00 NODE NO 340 341 319 352 309 COMP TYPE EL80wSR TRANS TEE TEE TEE 81 / 82 1.00/4.65

.50/R.00 1.00/2.43 1.00/2.43 1.00/2.43 C1 / C2 1.47/6.20 1,48/1.71 1.50/3 24 1.50/3.24 1 50/3.24 El / K2 1.20/1 80 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 5!! PRE 58 14047.79 14177.!2 8505.93 19177.12 19177.12 51 IDWI 213.92 1924 i13 1703.97 111.38 118.82 SIITHER3 150.46 163.95 8481.21 141.34 160.10 PM. PB 15042.30 9012.67 12648.25 19447.88 14465.96 PM.P8 0.F 28780.39 31550.00 74734.44 26993.27 27146.11 0 +F 13738.09 22537.32 h2086.19 12545.39 12680.16 RESI ST 27000.00 27000.00 45000.00 27000.00 27000.00 YIELD ST 18656.00 18656.00 27500.00 18656.00 18656.00 1

MOD. ELA.

25666000.00 25666000.00 27931000.00. 25666000.00 25666000.00 SR1,PRI

.5063

.4831

. 4% 9

.7744

.7754 SRI,5EC

.5821

.7078 1.2846

.5650

.5670 SRI TOTAL 1.3884 1.1909 1 7445 1.3395 1.3424

m amme

.m==.

am emums w

emans ammma mm a

m. -a

==

h

.............oo....e.............................................................................................................

5C0RE o

. NUTECH

-- VERSION 1.0.0 --

PACE 57 e NPPD COOPER-IG5CC OF RECIRCULATION SYSTEM 10/12/81 *

.s. o o oe v e e e e e e e e e e e e e e o o o o s e e e e e * * * * * * * * * * * * * * * * *

  • e e e e e e *
  • e o o o o o o o o e s e e e e e e *
  • e o o * * *
  • e e *
  • e e e e e e e e e e e e o e o o o o o e s e e e e o o s e e e e e e e e e e e e e STRESS ROLE INDEX EVALUATION - $UMMARY e

e..e e ee e e e e e e e e e e e e e e e e *

  • e o o * *
  • e e e e ** * * * * * * *
  • e e e e e e e e * *
  • e e e e *
  • e e e e e * * * * * * * *
  • e o e o o oo o o o o o e s e eo es e e ee e eee e e ee e e e eee ee ee e e e e e e m ee oe o ISI RPB-8J-27 RPB-8J-30 RP8-8J-31 RP8-BJ-25M RP8-8J-25M NELD ID L

WELO TYPE P-v V-E E-P BPC BPC 5

PIPE SIZE 28.00 28.00 28.00 28.00 48.00 NODE h0 306 305 301 299 299 COMF TYPE TRANS ELBOWLR EL80WLR TEE TEE 81 / 82

.50/1.00 1.00/3.33 1.00/3.33 1.00/2.43 1.00/2.43 C1 / C2 1 48/1.71 1.24/4.44 1.24/4.44 1 50/3.24 1.50/3.24 K1 / K2 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 5tiPRE51 14177.12 19177.12 14177.12 19177.12 14177.12 5I IDW) 109.03 113.67 43.55 45.49 129.93 SI(THER) 166.54 191.70 134.15 147.87 100.91 PM e P8 7197.59 14555.70 19322.17 19287.71 14492.97 PM*P8eQeF 25973.47

  • 23514.45 22494.00 26646.99 26865.61 0 e F 18775.88 8958.7,5 8171.83 12359.27 12372.64 RESI ST 27000.00 27000.00 27000.00 27000.00 27000.00 YIELD ST 18656.00 18656.00 18656.00 18656.00 18656.00 i:

M00. ELA.

25666000.00 25666000.00 25666000.00 25666C00.00 25666000.00 3

l SRIePRT

.3858

.7802

.7677

.7659

.7769 5RIe5EC

.6541

.5138

.5025

.5624

.5626' t

SRI TOTAL 1.0399 1.2940 1.2702 1.3262 1.3394

M M

ttes tWEE M

.M thed M

rease m

m m

m m

assa:

ammme, ammes

................................................o................................................................................

5C0RE o

. CUTECH

-- VERSION 1.0.0 --

PAGE 58 e NPPD COOPER-IGSCC OF RECIRCULATION SYSTEM 10/12/81 e

...eeee,eeeeeeeeeeeeeeeeee***************eoo***********eeee****eeeeeeeo****eeeeeee**eeeeeeeeeeeeeooooveeeeeeeeeeeeeeeeoseeeeeeee.

STRESS ROLE INDEX EVALUATION -

SUMMARY

e

...eeeeeeeeeeeeeeeeeeeeeeeeesseeeeee**eeeee********o*********e***eooe*********eoooooooooeseoooooooooooooooooseeeeeeeeeeeeeeeeeee, ISI RP8-8J-36 RP8-8J-38 RP8-8J-25L R P8-8 J-2 5 K RPS-8J-25J WELD ID WELD TYPE P-T P-T h0L-P P-E P-E PIPE SIZE 28.00 24.00 4.00 4.00 4.00 NODE NO 295 292 299 3121 312 COMP TYPE it E TEE TEE EL80WLR EL80WLR 81 / 82 1.00/2.43 1.00/2 43 1 00/2.43 1.00/2.43 1 00/2.43 C1 / C2 1.50/3.24 1.50/3.24 1.50/3.24 1.27/3.24 1 27/3.24 K1 / K2 1 20/1.80 1.20/1 80 1.20/1.80 1.20/1.80 1.20/1.80 SIIPRES) 19177.12 13753.72 8505.93 8505.93 8505.93 SI IDW) 363. 11 0.00 2208.11 331.01 331.01 i

SIITHER) 112.95 1996.31 8481.21 702 18 4267.49 PM e PS 15059.82 13753.72 13873.79 9310.75 9310.75 PM.P8+0eF 28296.28 33486.70 77675.72 18947.10 39751.86 0 e F 13236.46 19732.98 63801 94 9636.36 30441.11 I

RE5I ST 27000.00 27500.00 45000.00 45000.00 45000.00 YIELD ST 18656.00 18656.00 27500.00 27500.00 27500.00 t

M00. ELA.

25666000.00 25666000.00 27931000.00 27931000.00 27931000.b0

,1 SRI.PRI

.8072

.7372

.5045

.3386

.3386 SRI,$EC

.5749

.6749 1.3052

.6554

.9050 SRI TOTAL 1.3821 1.4121 1.8097

.9940 1.2436 t

amamm m.m.

e--a name name

'emma

==

meme.

w meme.

amma.

=

men, am em m---

=

===.

D

.....................o...........................................................................................................

a 5C0RE PACE 59 e

-- VERSION 1.0.0 --

. NuTECH NPPD COOPER-ICSCC OF RECIRCULATION SYSTEM 10/12/81 *

.seeeeeeeeeeeeeeeeeeeeooooooooooe*******************************eooooooeeeeeoeooooseeeeeeeeeeeeooooooooooooooetooooseeooeeeeeeeeee STRESS ROLE IhDEX EVALUATION -

SUMMARY

..seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeee**eeeeeeeo**eseseeee***eeeeeeeeeeeeeeeeeeeeeeeeeeee ISI RP8-8J-251 RP8-BJ-25H RP8-8J-25E RP8-8J-25F RPB-8J-25C WELO ID 9

WELD TYPE P-V V-T P-T P-T P-E PIPE SIZE 4.00 4.00 4.00 4.00 4.00 NODE NO 313 314 316 3161 316 COMP TYPE TRANS TEE TEE TEE EL80mLK

- - - -... - - _ = =

_. ~

81 / B2

.50/1.00 1.00/1.69 1.00/1.69 1.00/1.69 1.00/2.43-C1 / C2 1.76/2.10 1.50/2.26 1.50/2.26 1.50/2 26 1.27/3.24 K1 / K2 1.20/1.80 1.20/1.80 1.20/1.d0 1.20/1.00 1.20/1.80

$1(PRESI 8505.93 8505.93 8505.93 8505.93 8505.93 5t IDW) 2340.59 943.29 1177.35 0.00 468.12 SI(THERI 6352.91 10082.53 11016.59 0.00 3367.23 PM + PB 6593.56 10102.58 10498.76 8505.93 9644.11 PM.PSeQ.F 50798.86 60101.19 64846.48 15310.68 35298.66 0+F 44205.31 49998,.60 54347.72 6804.75 25654.55 RESI ST 45000.00 45000.00 45000.00 45000.00 45000.00 YIELD ST 27500 00 27500.00 27500.00 27500.00 27500.00 500. ELA-27931000.00 27931000.00 27931000.00 27931000.00 27931000.00

_ 1.

SRI,PRI

.2398

.3674

.3818

.3093

.3507

$RI.5EC 1 0701 1.1396 1.1918

.6214

.8476 i

SRI TOTAL 1.3099 1.5070 1.5735

.9307 1.1983 l

M M-M M

M M

M M

Eld

  • M ESE' W

M W.

ammm1 wt amnesi inmuust e.e..eeeeeeeeeeeeeeeeee.e..e..e.e.ee....ee.e.eeee.ee.eeeee.eee..e.eee..eee...ee.e.ee.e.ee.e........e.ee.ee...ee..e......e.ooee...

e 5 C0R E e NUTECH

-- VEASION 1.0.0 --

PAGE 60

  • e NPPD COOPER-IG5CC OF RECIRCULATION SYSTEM 10 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee/12/

eeeeeeeee o

STRES5 ROLE INDEX EVALUATION -

SUMMARY

e ee e e ee e e e e e e e e e e e e e e e e e e e e eee e e e e e ee ee e e e e ee ee e e e e e e e e ee e e e e e e e e e ee e e e e e e e e e e e e e e e e e e e e e e eee e e e e e e e e e e e e e e e e e e e e e e ee ee e e e e e eee, e e ISI RPB-8J-258 WELD ID WELD TYPE P-E PIPE SIZE 4.00 N00E NO 3181 COMP TYPE ELBOWLR 81 / B2 1.00/2.43 C1 / C2 1.27/3.24 K1 / K2 1.20/1.80 5IIPRESI 8505.93 r

SI (DW) 468 12 SIITHER) 3510.88 PM + P8 9644.11 PM+P8+Q+F 36136.90 O e F

-26492 79 RESI ST 45000.00 YIELD ST 27500.00 M00. ELA.

27931000.00

$RiePRI

.3507 SRIe5EC

.8576

,5RI TOTAL 1 2083

M his..aus-ama-

.aut m

l met m

m gist gar m

m m

m gue m

m e...e..ee..............e...........................oh......

,.e.e.....e.eee..........*

m oe.o.ee.ee.eoee.....

....ee...

5 CosE

. huffCH

-- V F N S IO N 1.C.0 --

PAGE 9.

e Side 55 RULE INDEa dv&LUaitCN FCR CORE SPRAY - LOOP A 11/13/81 e

...ee ee ee e e s e e e e e e e.t o. c o e s e e e e..e.v.ee e s e

  • e s e * *
  • e * * *. *
  • e e e.* * * * * * *e * * *
  • e e e **
  • e e * ** *
  • ee e ee e eo o *** ee eeeo o e ve e e e e e e ee e ee e e e e e e e e ee, 519tSS utLE th0fx Ev&LUATION - Su.9P AR Y e

.... e e.e.e ee eee e...e v e e e e e e e e e.e ee s s e....e ee e e e e e e e e e e e e e e.e *

  • ee e ee e e e e e e o os e e ee ee e o oe ee e e * * * **e e e e o oe ee e e e e e e e e ee ee e e e o o e e e ee e, o

ISI CSA-hJ-2 CSA-PJ-J CSA-BJ-4 C S A-B J-5 CSA-BJ-6 aELC 10

=FLD TTFE

$E-P P-E f_P P-F E4P PIPE SilE 10.C0 10.0C 10.00 10.00 10.00 h00f A0 1

5 10 15 20 COMP TYPE TRANS FLB0htR eld 0hLM ELB0wLR EL80mLR B1 / E2

.50/1.00 1.0C/2.97 1.00/2.97 1.00/2.97 1.00/2.97 C1 / C2 1.59/1.95 1.26/3.96 1.26/3.96 1.26/3.96 1.26/3.96 K1 / k2 1.20/1.eC 1.2C/1.80 1.2C/1.80 1.20/1.80 1.20/1.80 SIIPRESI 9410.77 9410.77 9410.77 9410.77 9410.77 SI (D>l 1499.08 1499.08 1999.08 1999.08 1999.08 SitTFEF) 770.23

+01.05 679.50 499.64 325.82 4

PP + Pd 6204.47 13864.74 13864.74 13864.74 13864.74 PP.Pu+C+T 2 *> 916. 0 7 277J2.02 29717.60 25435.03 27195.59 0 +F 19711.60 13Eb7.2d 15852.85

,14570.29 13330.85 w[5I ST 33500.CC 33500.00 33500.00 33500.00-33500.00 Ylf LD ST lec00.53 Ide00.00 18800.00 18800.00 18800.00 POD. ELA.

25750000.C0 25150C00.00 25750000.CC 25750000.00 25750000.00

__._____3 SRI,PRI

.3300

.7375

.7375

.7375

.7375 5kle5EC

.7369

.673R

.7020

.6538

.6662

__..s.______,______________

Shl TOTAL 1.0869 1.4113 1.4355 1.4213 1.4036 e

.h

.M M

W M

<M M

M M

M M

m m

-eme m

esma

......o.....*.e..e.eeee.o..e......oo.eo......*.e.o.e.e........e.................................................................

5CCM E o

vE45 ION 1.0.0 --

PACE 10 *

  • NUTECH iTaE55 mute INOEE EVALUATICN FCR CORE SPdAY - LOOP A 11/13/81 o

.e..... eeeeeeeeeeeeeeeeees.e e*****ee****eee*****e***eeee**ee,*eeeeeeeeeeeeeeee****eoeeeeeeeeeeeeeeeee*****eeeeeeeeeee++eeeeeeee STRtS5 kuLE INDEx EbaLuATION -

SUMMARY

e

.....ee ee ee e e e e e e e e e e e e e e e e e e e e e e * * ** * * *

  • e e e e e e e e e e o o o e e e e e e e e e ee ee e e e o o o o o o v e e e* ** e e ee e e e e ee e e o o ooo o oo o o o o e o e e ee ee ee e e e e e e e e e e e e i

ISI CSA-eJ-9 C5A-eJ-10 CSA-C5A-BF-12 mELC 10 e

aELD TYPE r-t E-P P-50CK0LET P-P PIPE SIZE 10.00 10.0C 1C.CC 10.00 NODE ha 3S 40 AS SC COMP TYPE ELoca$w CLuch5R TEE PIPE i

81 / H2 1 00/3.d9 1.0C/3.59 1.CC/2.1C

.50/1.00 C1 / C2 1.52/s.19 1.32/S.19 1 50/2.60 1.10/1.00 K1 / W2 1.20/1.e' 1.2C/1.co 1.20/1.u0 1.20/1.80

$IIPRESI 9410.77 9410.77 9410.77 941u.77 5! IDhl 1999.05 1499.06 1499.08 1499.05 SIITNERI 136S.01 l'326.6e 1226.72 1070.52 PM e Pd 19247.91 13247.91 12S62 46 6204.47 PM.Po+0*F 43an3.F0 435e5.44 30703.31 17047.51 0. F 2803S.79 20277.53 18140.85 10843.04 HESI ST 33300.00 33'00.00 33500.00 33500.00 YIELD ST 18300.C0 16eCO.00 15a00.00 18800.00 MOD. ELA.

2$750000.00 eS7 SOC 00.00 2S730000.00 257S0000.00 SRI PRI

.5111

.6111

.6662

.3300 SR I o SI C

.an39

.u7ee

.7346

.6308

_==-------------....-.........--------

SRI TOTAL 1.6949 1.o895 1.4028

.9608 J

6 e

M Mm M elme emme emin game meine w

w w

op eeeeee ee ss eeoo oe 'e se ee ee ee esse ee eo oe *e ee e e e eeeee eeoo oo o* ** ** **ee eeee eeee eeeeeeeeeeee e* ***eeeeeeeee ee eeee eooose eeee 5C 0R E

-- WEkSich 1. 0.0 -

PACE 9

  • e e huTECH STwf55 RULE INDE x E W ALu ATIch FOR CORE SPdAY - LOOP 8 11/13pel e
  • e s es e e e e *
  • e e e e e
  • e e e e e e e e e e e * * * * * * * * * *
  • e e * * * * * *
  • e * *
  • e e *
  • e * *
  • e e * * * * * * *
  • e
  • e STRE SS kuLE INDEX EVALUATION -

SUMMARY

eeee**e*ee**e,*e**eeeeeeee+++++++++eveeeee******eeeeeee***********eee***************************o*************************o*****e e

ISI C56-8J-2 C58-uJ-3 C58-8J-4 C58-BJ-5 C58-dJ-6 WELO 10 r

WELO TYPE SE-P P-E E-P P-E E-P PIPE SIZE 10.00 10.00 10.00 10.00 10.00 NODE NO 1

5 10 1$

20 COMP TYPE TRANS EL60hLR EL80hLR ELBOWLR EL80wLR B1 / 82

.50/1.00 1.00/2 97 1 00/2.97 1.00/2.97 1.00/2.97 C1 / C2 1 59/1.95 1.26/3.96 1.26/3.96 1.26/3.96 1 26/3.96 K1 / K2 1 20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 Sl(PRESI 9410.77 9410.77 9410.77 9410.77 9410.77 51 (Dwl 1999.08 1499.08 1499.08 1999.08 1499.08 SIITHERI 775.53

'397.89 671.74 489.10 314.76 PM e PB 6204.47 13864.74 13864.74 13864.74 13864.74 PM*Ps Q F 25934.44 27709.45 29662.27 28359.89 27116.76 0. F 19729.97 13844.74 15797.S3 14495.14 13252.02 l

HESI ST 33S00.00 33500.00 33540.00 33$00.00 33500.00 YIELD ST 18800.00 18dOO.00 18800.00 18800.00 18800.00 N00. ELA.

25750000.00 25750000.00 25750000.00 25750000.00 25750000.00 4

5dt,PRI

.3300

.7375

.737S

.7375

.7375 SRie5EC

.7S72

.673S

.7012

.6827

.66$0 t

l' 5RI TOTAL 1.0872 1.4110 1.4387 1.4202 1.4025 q

to

M M

M N

Sumat-M muas' inume-tenus '

w ammus numens m

m.

m e eeee ee e ee e ee ee e e e e e e s c o e 4 8 4 4 66 e e e eee e e ee ee e e e ee eoo Oee eeeee eeeeo ooooooccee coce eeco coco co coococco eeeeeeee O

e

~

5C 4 E PAGE 10 0

-- VERSION 1.0.0 --

e NUTECH STRESS RULE INDEX E V ALU A TION FOR CORE SPRAY - LOOP 8 11/13/81 e eee e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e >'e e e e e e.e e e e e ee e e e e e e e e e i

e STRESS tuLE INDE X EVALUATION -

SUMMARY

eee eeee.ee ee eee e ee e eeee e e*** *ee s ** eo eo o o oe ++ eee e+ + eee ee e e* **ee seee ee e e e+ ++ eooe ee eeee eo ISI C58-8J-9 C58-BJ-10 C58-C58-BF-12 WELD ID WELD TYPE P-E E-P P-50CKOLET P-P PIPE 5tlE 10.00 10.00 10.00 10.00 NODF NO 35 40 45 50 COMP TYPE ELBOW 5R ELBOWSR TEE PIPE 81 / 82 1.00/3.89 1.00/3.89 1.00/2.10

.50/1.00 C1 / C2 1.52/5.19 1.52/5.19 1 50/2.80 1.10/1 00 K1 / K2 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1 80 SIIPRESI 9410.77 9410.77 9410.77 9410.77 51 IDWI 1499.08 1499.08 1499.08 1999.08 5IITnERI 1396.92 1353.94 1254.66 1096.88 PM e PB 15247.91 15247.91 12562.46 6204.47 PM+P8eQeF 44181.84 43780.19 30834.21 17094.96 0 t F 28933.93 28532.28 18271.75 10890.49 RESI ST 33500.00 33500.00 33500.00 33500.00 YIELD ST 18800.00 18800.00 18800.00 18800.00 M00. ELA.

25750000.00 25750000.00 25750000.00 25750000 00

_____._=__

SRI,PRI

.8111

.8111

.6682

.3300 SRI,5EC

.8881

.5824

.7364

.6314 SRI TOTAL 1.6992 1.6935 1.4047 9615

.....en-m.e...... p...................e......................e........e r

,,..ee n u e e

e..eee.

5Cc.4 Pa..

14.

-- VERSION 1.0.0 --

11/14/81 e

  • NuTECH STdE55 RutE INCEx EVALUAftch eeeeeeeeeeeeeeeeeeeeeeeeeee,

...ee ee.e e.

...e e..... ee eeee eeeve+ ee e e e e e e ee ee e e e e e e e e e e e e ee ee e eee eeee e e e e ee e e

SUPPARY STRESS RLLE In0Ex EwALUAftch o..ee+.e.e+4-t. +seeeeeeeeeeeeeeeeeeeeeeese++evee***e++++++eeeeeeeeeeee++eeeeee**eee ISI cwa-8J-1 ChA-64-2 ChA-dJ-3 CWA-8J-4 CWA-8J-S WELO 10 WELD TYPE P-E L s 01. E T P-P P-P P-E E-P 0

PIPE SIZE 6.00 6.CC 6.00 6.00 6.00 NODE ha J7S S

10 10 15 COMP TfPE TEE PIPE PIPE ELBOWLR ELB0mLA

........ _...... _...................................... -...,......... ~..

81 / 82 1.00.*2.21

.SC/1.00

.50/1.00 1.00/2.67 1.00/2.67 C1 / C2 1.50/2.94 1.1C/1.00 1.10/1.00 1.26/3.56 1.26/3.56 n1 / K2 1.20/1 80 1.2C/1.80 1.20/1.80 1.20/1.80 1.20/1.80 SitPRESI 7521.18 7821.18 7821.18 7821.18 7s21 18 51 10wl 1500.40 1500.40 1500.40 1500.40 1500.40 SitTHERI 17800.73 12845.44 10697.41 10697.41 16499.20 PM

  • PB 11133.77

'5410.99 5410.99 11827.79 11827.79 l

PnePB'QeF 116349.72 36146.46 32280.02 90021.06 127203.97 0

  • F 105215.95 30735.47 26869.03 78193.27 115376.18 NE 51 ST 39000.00 39000.00 39000.0-0 39000.00-39000.00

.I L

YlELD ST 18860.00 18860.00 18860.00 18860.00 18860.00

(

MOD. ELA.

2S785000.00 2578SC00.00 2S785000.00 2S78S000.00 25785000.00 r.

.......... _ _. - -.. - - - -... _...... _............ ~........

SRI P21

.5903

.2869

.2869

.6271

.6271 SR: 5EC 2 0476

.9901 9352 1.6640 2.1919

....~......................................................

l-SRI TOTAL 2 6380 1.2770 1 2221 2.2911 2.8190 l

l

- ~... - - - - - - - - -

M M

M M

M M

M M

yM M

K M

M M

M M

M

.e.................**...........e..e..................e........................................................................

5 C0>E o

vERSI0h 1.0.0 --

PACE IS 9

. huTECH STRES$ GULE IhCEx EVALUATION 11/14/81 *

....eeeee,*eeeeeeeeeeeeeeeeeeeeeeeee**********eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee*****eoeooo****ee****eeeeeeeeeee******eseeeee STRESS RLt.E INDEX EVALUATION - SUPPARY

.e.ee ee ee e e ee ee e e ee e e e e e e e ee e e ee e e e ee e * *

  • e * * * ** e e e e e e e e e e e *
  • e e e ee e e*
  • e e e e + + e * * * ** o* * * **
  • e o * * *
  • e oo es e *
  • e ee ee e e e eee ee eo o s e e eee e o o o o

!$1 C*A-eJ-7 C=A-8J-8 CW A-8 J-9 CmA-8J-10 CWA-8J-11 mELO ID e

MELD TYPE P-E E-P P-E E-P P-E PIPE SIZE 6.00 6.00 6.00 6.00 6.00 h0DE ha 25 30 35 40 45 COMP TYPE ELB0mLR EL80mLR FL80mLR EL80mLR EL80 LR 81 / B2 1.00/2.67 1.00/2.67 1 00/2.67

~.00/2.67 1.00/2.67 C1 / C2 1.26/3.56 1.26/3.56 1.26/3.56 1.26/3.56' 1.26/3.56 K1 / M2 1.20/1.80 1.20/1.80 1 20/1.80 1.20/1.80 1.20/1.80 sitPRE58 7821.18 7821.15 7821.18 7821.18 7821.18

$1 (Okt 1500.40 1500.40 1500.40 1500.40 1500.40 SitTHERI 2178.66

'2278.88 1S29.90 2684.88-2069.03 PM

  • F8 11827.79 11827.79 11827.79 11827.79 11827.79 PMeP8eceF 35425.48 36067.79 31267.63 38669.74 34722.88 O e F 23597.69 24240.00 19439.84 26841.95 22895.08 RESI ST 39000.00 39000.00 39000.00 39000.00 39000.00 YIELO ST 18860.00 18860.00 18860.00 18860.00-18860.00 NOD. ELA.

25785000.00 25785000.00 25785000.00 25785000.00 25785000.00 5kt.PRI

.6271

.6271

.6271

.6271

.6271 SR!e5EC

.8888

.8979

.8298

.9349

.8788

==.__.____..

3......

SRI TOTAL 1.5159 1.5250 1.4S69 1.5620 1.5060

M Mm humab M

Muk bunne M

anan.

N Y

emme

.a namn m.mmen aume.

m

===.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee****eee******ee***eeeeee*******ee,**eeeeee**eeeee****eooeeeee 5C0k E e

-- VERSI0h 1.C.0 --

PACE 16 e4 11/14/81 e STnE55 RULE IhCEx EVALUATIO~

e huTECn seeseeeeeeeeeeeeeeeeee************eeeeee***veeeeeeeeeeeeee**ee**********

e e

SOMP ARY STRESS AutE INDEX EVALUATION eeeeeeeeeeeeeeeeeeeeeeeesseeeeeeeeeeeeeeeeee eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee*********eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee*******w e

CWA-tJ-16 i

151 CWA-BJ-12 ChA-8J-13 ChA-ChA-8J-15 MELD 10 uELO TYPE E-V V-P P-50CKOLET P -E E-P PIPE SIZE 6.00 6.CC 6.00 6.00 6.00 NODE h0 50 55 60 65 70 COMP TYPE EL80mLR TRAN5 TEE ELBOWLR ELB0mLR

-.._____.._..__........._.__...___.....__.___..__.....____._.._3._._...____

61 / B2 1.00/2.67

.50/1.00 1.00/1 87 1.00/2.67 1.00/2 67 C1 / C2 1.26/3.56 1 67/2.10 1.50/2.49 1.26/3.56 1.26/3 56 K1 / K2 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80*

1.20/1.80 SIIPRESI 7821.18 7821.18 7821.18 7821.18 7821.18 51 (DWI 1500.40 1500.40 1500.40 1500.40 1500.40 5ItTHEpl 1905.22 4409.53 5312 86 6905.95 7668.03 PM e P6 11827.79 5410.99 10625.88 11827.79 11827.79 PM.P8 0.F 33673.04 38C27.53 44644.63 65722.09 70006.14 0

  • F

'21845.24 32616.dk 34018.75 53894.29 58778.34 Rest ST 39000.00 39000.00 39000.00 39000.00 39000.00 YIELD ST 18860.00 18860.00 18860.00 18860.00 18860.00 MOD. ELA.

25785000.00 25785000.00 25785000.00 25785000.00 25785000.00 SRI,PRI

.6271

.2869

.5634

.6271

.6271 SRI.5EC

.8639 1.0168 1 3368 1.3190 1.3883 SR[ TOTAL 1 4910 1.3038 1.6002 1.9461 2.0154

w am.m mand lemas sent M

M M

M M

E E

E O

eeeeee,"..,eeeeeeeeeeeeeeeeeeeeeeessaeeeeeeeeeeeeeeo.....e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees. D oeooooee e

5 C.R E e

e NUTECH

-- WE4510h

.0.0 --

PACE 17 e

+

e STRESS RULE INCEx EVALUATION 11 e

eeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeee************e*eeeeeeeeeeeeeeeeeeeee*******eoeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee/14/81 eeeeeeeee e

STRESS RULE INDEX EtatuATIch SUPPARY e

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.... eee ooeeeeeee.

s I5I cwa-8K1-18 C m A-8 J-19 CWA-8J-20 CmA-8J-21 ChA-8J-22 mELO 10 MELD TYPE

.P-50CKOLET P-E E-E E-V V-P e

PIPE SIZE o.00 6.00 6.00 6.00 6.00 NODE ha 75 80 85 95 100 COMP TYPE TEE EL80mLR ELbCmLR EL80mLR TRANS 81 / 82 1 00/1.87 1.00/2.67 1.00/2.67 1.00/2.67

.50/1.00 C1 / C2 1.50/2.49 1.26/3.56 1.26/3.S6 1.26/3.56 1.67/2.10 K1 / K2 1.20/1.80 1.20/1.80 1.20/1.80 1.20/1.80 1 20/1.80 SIIPRESI 7821.18 7E21.18 7821.18 7821 18-7821.1s SI IDul 1500.40 1500.40 1500.40 1500.40 1$00.40 SIITbER) 7482.68 5991.53 5850.89 4754.15 3831.66 l

PM e Pa 10625.88 11827.79 11827.79 11827.79 5410.99

~

i PM+P8,Qef

$4379.13

$9861.67 58960 30 51931.43 35843.16 0* F 43753.25 48C33.88 47132.51 40103.64-30432.17 ME5I ST 39000.00 39000.00 39000.00 39000.00 39000.00 YIELO ST 18860.00 18860.00 18860.00 18860.00 18860.00 n00. ELA.

25785000.00 2578SC00.00 25785000.00 25785000.00 2S785000.00 5RIePRI

.5634

.6271

.6271

.6271

.2869 SRI,5EC 1.1750 1.2358 1 2230-1.1232 98So

......___......_.....__............--===_..._............. _ _-._,.__-.__.__..

5RI TOTAL 1.7384 1.8629 1 8501 1.7503 1.2727 9

Id L_

~ r f

sense

==-se n==mus soumis ausses soumme nome emme M

asse M

M M

M M

ammmme

.....e..................e............................e..e..................................e....................................

5 CCE E o

. NUTECH

-- vER5!0h 1.0.0 --

PACE 18 o 3

STRESS Rule INCEX EVALUATION 11/14tti *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee*********+eeeeeeeeeeeo***eeeee*******eeeeeeee***eee****eooeveeoooooseeeeeeeeeeeeeeeeeeeees STRESS RLLE Ih0EX EVALUATION - SunMARY e

3

...eeeeeeeeeeeeeeeeeet.eeeeeeeeeeeeeeee*****ee****eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeoeooooeeeeeeeeeeeeeeeeeeeeeeeeee,

~

151 CWA-8J-23 C u A-E J-2 5 CWA-ChA-8J-27 WELD 10 WELD TYPE P-P P-E E-50CKOLET E-SE E-E PIPE SIZE 6.00 6.00 6.00 6.00 20.00 NODE ha 10$

115 120-120 380 COMP TYPE PIPE EL80mSR TEE EL80W5R EL80kSR

........__..._.__3_.....

81 / 82

.50/1.00 1.00/3.50 1.00/1.87 1.00/3.50 1.00/3.91 C1 / C2 1.10/1.00 1.53/4.67 1.50/2.49 1.53/4.67-

,1.4S/S.21 K1 / K2 1.20/1.80 1.2C/1.80 1 20/1.80 1.20/1.80 1.20/1.80

$!! PRES) 7821.18 7821.18-7821.18 7821 18 11154.22 51 (Okt 1500.40 1500.40 15u0.40 1500.40 1499.82 SitTHERI 3555.21

~ 419 3. 59 5632.27

$632.27 2795.45 PM e PB 5410.99 13C72.04 10625.88 13072.04-17013.48 PM*PB+0+F 19424.05 62214.63 46077.58 74298.28 59693.57 0 *F 14013.06 49142.59 35451.69 61226.24 42680.09 RESI ST 39000.00 39000.00 39000.00 39000.00 28500.00 YIELO ST 18860.00 18860.00 18860.00 18860.00 18800.00 MOD. ELA.

2$785000.00 2S78SC00.00 2S785000.00 25785000.00-2S750000.00 I

2._____.....,_

'i SRIePRI

.2869

.6931

.5634

.6931

.9050 SRI +5EC

.7$27 1.251$

1.0571 1.4231 1.012$

_.___........==

.__--==

4 5RI TOTAL 1.0396 1.9446 1.620S 2.1162 1.917$

O f

amen e-o

===e eman umme sesse genum immit M

alum M

M M

M M

M M

M r

f>

Q oeeeeeeet.

eeeeeeeeeeeeeeeeeeeeee************************o******

.***eooose * * **** *****ee***eeeeee e****e ee eeeee eeeeeooes _ oe**ooe*

e 5CC8 E o

o huTECH

-- WER$10h 1.0.0 --

PACE 19 *-

e STRESS PLLE INCEx EWALUATION 11/14/81 e eseeeeeeeeeeeeeeeeeeeeeeeeeeeeee++eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeoeeseeeeeooooooooooooeveseeeeeeeeeeeeeeeeee e

STHE55 WLLE INDEX EVALUATION -

SUMMARY

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeee***eooooeeeee++eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee, ISI i

mELO 10

. ELD TYPE E-P E-P P-T V-P P.T PIPE $12E 20.00 20.00 20.00 24.00 24.00 n0DE ha 185 395 400 109 110 COMP TYPE EL80mSR EL80h5R TEE TRANS TEE

_ _ =......... - -.............. - - -..... - - - - - - -......

81 / B2 1.00/3.91 1.00/3.91 1 00/2.60

.50/1.00 1 00/2.43 C1 / C2 1.45/5.21 1.45/5.21 1.50/3.46 1.49/1.74 1.50/3.24 K1 / R2 1.20/1.80 1.2C/1.80 1.20/1.80 1.20/1.80 1.20/1.80 SIIPRE51 11154.22 11154.22 11154.22 12415.0D 12415.05 SI 10hl 1999.82 1499.82 1499.82 1559.03 1559.03 SIITHERI 0.00 1984.61 1670.86 1816.73 1662 22 PM e PS 17013.48 17013.48 15049.73 7766.56 16205.02 PM.P8eQeF 33483.64 47403.24 39842.25 32772.83 41140.95 Qe F 16470.16 30389.76 24792.52 25006.27-24935.93 RESI ST 28500.00 28500.00 28500.00 27500.00 27500.00 YIELD ST 18800.00' 18800.00 18800.00 18800.00 18800.00 MGJ. ELA.

25750000.00 25750000.00 25750000.00 25750000.00 25750000.C0

--...--......--...---.......--................--...3-..--.....--

SRI.PRI

.9050

.9050

.8005

.4131

.8620 SRI.5EC

.6397

.8377

.7501

.7469

.7459

==.--..

=...................--.....,..............

SRI total 1.5447 1.7427 1.5586 1.1600 1.6079 I

i

M EM M

M M

M M

M M

M M

M M

M M

M M

...e......e..........................................e.................................e........e............e....e.............

5 C0>E o

. NOTECH

-- WERSIOh 1.0.0 --

PACE 20

  • STRESS RULE thCEx EVALUATION 11/14/81 *

...eeeeeeeeeeeeeeeeeeeeeeeeee********eeeeo****eeeeeeeee***********o******eeeeee****eoooe******eoooosee*****eeeeeeeeeeeeeooseeeeos STRESS WULF th0EX EVALUATIch SUPMARY e

...e e e e e o o o s e e e e e eo o o e e e e e e e e e e e e * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

  • e o e s e e e * * * * * * * * * * * * * *
  • e e t e o o e *
  • e o o o oo o o es e o o o o o e. c o c e o e e e e e e e o s 15!

WELD 10 e

MELD TYPE V-P P-T PIPE 5tlE 24.00 24.00 NODE ha 290 291 COMP TYPE TRANS TEE 81 / 82

.50/1.00 1.0C/2.43 C1 / C2 1.49/1.74 1.50/3.24 K1 / M2 1.20/1.80 1 20/1.80 SitPRESS 12415.05 12415.05 SI (DW3 1559.03 1559.03 SIITNER) 1442.96

~ 1472.51 PM e PB 7766.56 16205.02 PM*PueQ+F 31603.27 40034.1$

Q e F 23836.71 23829.12 RESI ST 27500.00' 27500.00 YIELD ST 18800.00 18800.00 M00. ELA.

25750000.00 25750C00.00 i

SRI.PRI 4131

.5620 I

SRI,5EC

.7303

.7301 SRI TCTAL 1.1434 1.5921

.