N Nebraska Public Power District Nebraska's Energy Leader NLS990020 March 22,1999 71 S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-001 Gentleman:

Subject:

Inservice Inspection Summary Report Cooper Nuclear Station, NRC Docket No. 50-298, DPR-46

References:

(1)

ASME Section XI,1989 Edition (2)

ASME Section XI,1992 Edition,1992 Addenda, Subsection IWE In accordance with the provisions of 10CFR50.55a and References 1 and 2, The Nebraska Public Power District (District) hereby submits the Inservice Inspection Summary Report for the Fall 1998 Refueling Outage at Cooper Nuclear Station. This report includes the Owner's Report for Ireervice Inspections and the Owner's Report for Repairs or Replacements.

Also included in this report is an analytical evaluation for Reactor Pressure Vessel (RPV) shell weld indications, and augmented examination results of the RPV including internal Core Spray piping examinations performed in accordance with the Boiling Water Reactor Vessel Internals Project Guidelines, BWRVIP-18.

If you require any additional information regarding this report, please call.

f Sincerely, N

D ohn H. v ie Vic resi ent leur Energy 0

/dnm N

t j

g Attachments 9903260332 990322

-~*

PDR ADOCK 05000298 **

G PDR 3

Cooper Nudear Station P.O. Box 98/ Brownville, NF 6832? 0098

\\

Telephone: (402) 825 38n / Fax: (402) 825-521?

httpf/www.nppd.com

f;T l

NLS990020

- March '22,1999

- Page 2 of 2 l

cc:

- Regional Administrator

USNRC - Region IV-Senior Project Manager L

USNRC - NRR Project Directorate IV-1 Senior Resident Inspector USNRC NPG Distribution w/o attachments v:

P i

i 1

I r

l J

l l

1 i

I t-Lc_

j

r-l ATTACHMENT 3 LIST OF NRC COMMITMENTS l

Correspondence No: NLS990020 1

The following table identifies those actions committed to by the District in I

thic document. Any other actions discussed in the submittal represent intended or planned actions by the D.4 strict. They are described to the NRC for the NRC's information and are not regulatory commitments.

Please notify the NL&S Manager at Cooper Nuclear Station of any questions regarding this document or any associated regulatory commitments.

COMMITTED DATE COMMITMENT CR OUTAGE None 1

l l

PROCEDURE NUMBER 0.42 l

REVISION NUMBER 6 l

PAGE 9 OF 13 l