Health Physics Sample Records Sample ID: 142448 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

1405288D 18 STAR 18-20 Dirt Sample

~mmon Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N

Contact:

COOPER, TERRY L Survey No:

Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: Count to MDA Reviewed: DYNES, WILLIAM J Date: 05/30/14 08:58 Comments:

I OrigJ.!!J Mat. SizeNolume: 2129 ml Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00

Description:

STAR 18 SOIL SAMPLE Collection Sample Tech: DYNES, WILLIAM J Sample Date: 05/29/14 08:02 Count Time: 900 (secs.)

Tritium Req: No Sample SizeNolume: 2129 GRAMS Instructions:

Comments: COUNT TO MDA

[.kLSS_SJ Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: No Form 212 Ready: ~

I Location Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: 3" (in.) Equip ID:

Stored By:, Date: 00/00/00 00:00 Sample Loe:

Other:

Material Loe:

06/18/201411:54 Page 1 of3

Health Physics Sample Records Sample ID: 142448 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140528BD 18 STAR 18-20 Dirt Sample I Analysis I Geometry MCA ID Quant. Units Method FP/AP Lab Analysis~}' Date Mod ID Mod Date B_1L_marinelli_sand_ 30296 2129GR .000 PARK, MICHAEL C 06/02/14 09:58 lsotoe~ Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.00001311: 1.57E-6 64.455% 40 0 TL-208 NT 5.339E-7 9.12E-8 2.611% 208 0 PB-212 NT 7.192E-7 1.677E-7 3.517% 212 0 Bl-214 NT 8.644E-7 1.268E-7 r 4.227% 214 0 PB-214 NT 9.076E-7 2.203E-7 4.438% 214 0 RA-226 NT 3.996E-6 1.464E-6 r 19.542% 226 0 U-235 NT 2.473E-7 9.06E-8 1.209% 235 0 BE-7 AP 8.7061E-7 Iv 0.000% 7 0 MN-54 AP 1.1135E-7 Iv" 0.000% 54 0 MN-56 AP 1.5116E-7 IV" 0.000% 56 0 C0-57 AP 1.0675E-7 Iv 0.000% 57 0 C0-58 AP 8.4656E-8 Jv 0.000% 58 0 C0-60 AP 3.965E-8 Iv 0.000% 60 0 SB-124 AP 8.3775E-8 ji7 0.000% 124 0 SB-125 FP 3.1326E-7 ji7 0.000% 125 0 CS-134 FP 9.6174E-8 Jv 0.000% 134 0 CS-137 FP 9.924E-8 Iv 0.000% 137 I Analysis Review I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/1410:18 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:

Comments:

06/18/201411:54 Page 2 of 3

Health Physics Sample Records Sample ID: 142448 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized:

Description:

140528BD 18 STAR 18-20 Dirt Sample I Review/Approve I HP Review Reviewed: COOPER, TERRY L Date: 06/10/14 10:19 Comments: U-235 likely mis-Id from Ra-226 energy peak; peak at 429 keV is not due to plant-produced nuclide Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:

Final Ap_p_roval Approved: COOPER, TERRY L Date: 06/10/1410:19 Comments:

06/18/2014 11 :54 Page 3 of 3

  • SONGS HEALTH PHYSICS REPORT 2-JUN-2014 09:54 *
  • >>>>> SAMPLE PARAMETERS<<<<< *
  • Title 140528BD 18 STAR 18-20 DIRT SAMPLE *
  • ID 30296 Acquisition date: 2-JUN-2014 09:51:46. *
  • Start Time: 2-JUN-2014 09:51:00. *
  • Stop Time: 2-JUN-2014 09:51:00. Counting System U2GSP *
  • Quantity 2.12900E+03 GR IHPS Sample Number: 142448 *
  • Geometry B lL marinelli_sand_l Analysis Library HP NATURAL *
  • Operator: MICHAEL PARK *
  • >>>>> B #42-TP11663A PARAMETERS<<<<< *
  • Elapsed Live Time 0 00:03:00.40 Calibration 1-JUN-2014 20:28: *
  • Elapsed Real Time 0 00:03:00.46 Energy Offset -5.64750E-02 *
  • Deadtime 0.0% Energy Slope 4.99765E-Ol *
  • Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1. 00000 *
  • Half Life Ratio 8.00000 Sensitivity 5.00000
  • Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 77.67 64 101 3.50 155.53 148 16 38.3 4.45E+OO BI-214 PB-212 PB-214 1 186.28 38 30 1. 94 372.85 367 14 36.6 1.72E+OO U-235 RA-226 1 238.69 80 79 1. 39 477.71 474 11 23.3 4.21E+OO PB-212 1 295.47 37 9 2.15 591. 32 587 12 24.3 9.90E-01 PB-214 1 352.36 42 20 2.09 705.16 698 13 26.2 3.90E+OO PB-214 1 429.43 13 10 1. 78 859.37 852 14 58.6 8.57E-01 1 582.83 37 0 2.21 1166.32 1161 12 17.1 4.63E-01 TL-208 1 609.06 46 0 1. 98 1218.79 1212 11 14.7 4.18E-01 BI-214 1 1460.28 84 3 1. 99 2922.04 2916 12 11. 9 7.67E-01 K-40

Summary of Nuclide Activity Page : 2 Sample ID : 30296 Acquisition date 2-JUN-2014 09:51:46 Total number of lines in spectrum 9 Number of unidentified lines 1 Number of lines tentatively identified by NID 8 88.89%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y 1. 00 1.318E-05 1. 318E-05 0.157E-05 11. 88 A TL-208 3.05M 1. 64 3.250E-07 5.339E-07 0.912E-07 17.08 A PB-212 10.64H 1. 00 7.174E-07 7.192E-07 l.677E-07 23.32 A BI-214 19.90M 1. 08 7.990E-07 8.644E-07 l.268E-07 14.66 A PB-214 26. SOM 1. 06 8.560E-07 9.076E-07 2.203E-07 24.27 A RA-226 1600.00Y 1. 00 3.996E-06 3.996E-06 1.464E-06 36.64 A U-235 7.04E+08Y 1. 00 2.473E-07 2.473E-07 0.906E-07 36.64 A Total Activity 2.012E-05 2.045E-05 Grand Total Activity : 2.012E-05 2.045E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit

Unidentified Energy Lines Page : 3 Sample ID : 30296 Acquisition date : 2-JUN-2014 09:51:46 It Energy Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err %Eff Flags 1 429.43 13 10 1.78 859.37 852 14 7.25E-02 58.6 1.20E+OO Flags: "T" = Tentatively associated

Interference Report Page : 4 Sample ID : 30296 Acquisition date 2-JUN-2014 09:51:46 No interference correction performed

Nuclide Line Activity Report Page : 5 Sample ID : 30296 Acquisition date 2-JUN-2014 09:51:46 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 84 10.67* 4.212E-01 1.318E-05 1.318E-05 11. 88 TL-208 72.80 ------ 2.14 l.070E+OO ------ Line Not Found ------

74.97 ------ 3.60 1.156E+OO ------ Line Not Found ------

84.79 ------ 1. 27 1.506E+OO ------ Line Not Found ------

252.45 ------ 0.80 1.745E+OO ------ Line Not Found ------

277.28 ------ 6.80 1.645E+OO ------ Line Not Found ------

510.61 ------ 21. 60 l.035E+OO ------ Line Not Found ------

583.02 37 86.00* 9.202E-01 3.250E-07 5.339E-07 17.08 763.06 ------ 1. 64 7.126E-01 ------ Line Not Found ------

860.30 ------ 12.00 6.341.E-Ol ------ Line Not Found ------

PB-212 74.81 ------ 10.50 1.150E+OO ------ Line Not Found ------

77 .11 64 17.70 1.260E+OO 2.015E-06 2.020E-06 38.26 87.19 ------ 6.27 1.579E+OO ------ Line Not Found ------

90.13 ------ 1. 86 l.662E+OO ------ Line Not Found ------

115. 12 ------ 0.59 2.085E+OO ------ Line Not Found ------

238.58 80 43.60* 1.804E+OO 7.174E-07 7.192E-07 23.32 300.03 ------ 3.34 1.562E+OO ------ Line Not Found ------

BI-214 76.86 64 0.58 l.260E+OO 6.150E-05 6.653E-05 38.26 79.29 ------ 0.97 1.320E+OO ------ Line Not Found ------

609.31 46 46.10* 8.836E-01 7.990E-07 8.644E-07 14.66 665.44 ------ 1. 56 8 .131E-01 ------ Line Not Found ------

768.35 ------ 4.88 7.078E-01 ------ Line Not Found ------

806.16 ------ 1. 23 6.754E-01 ------ Line Not Found ------

934.04 ------ 3.16 5.861.E-Ol ------ Line Not Found ------

1120.?.7 ------ 15.00 4.982E-01 ------ Line Not Found ------

1155 .18 ------ 1. 69 4.860E-01 ------ Line Not Found ------

1238 .11 ------ 5.92 4.615E-01 ------ Line Not Found ------

1280.95 ------ 1. 4 7 4.51.0E-01 ------ Line Not Found ------

1377.66 ------ 4.02 4.323E-01 ------ Line Not Found ------

1385.30 ------ 0.78 4. 311E-01 ------ Line Not Found ------

1401.48 ------ 1. 39 4.287E-01 ------ Line Not Found ------

1407.97 ------ 4.48 4.277E-01 ------ Line Not Found ------

1509.22 ------ 2.19 4.165E-01 ------ Line Not Found ------

1583.22 ------ 0.72 4.120E-01 ------ Line Not Found ------

1661. 26 ------ 1.15 4.103E-01 ------ Line Not Found ------

1729.58 ------ 3.05 4 .114E-01 ------ Line Not Found ------

1764.49 ------ 15.90 4.128E-01 ------ Line Not Found ------

1847.41 ------ 2.12 4.187E-01 ------ Line Not Found ------

PB-214 53.17 ------ 1.10 2.929E-01 ------ Line Not Found ------

74.81 ------ 6.52 1.150E+OO ------ Line Not Found ------

77 .11 64 11. 00 l.260E+OO 3.243E-06 3.438E-06 38.26 87.19 ------ 3.88 l.579E+OO ------ Line Not Found ------

90.13 ------ 1.15 l.662E+OO ------ Line Not Found ------

241.92 ------ 7.46 1. 7 90E+OO ------ Line Not Found ------

258.94 ------ 0.55 1. 718E+OO ------ Line Not Found ------

295.09 37 19.20* 1.578E+OO 8.560E-07 9.076E-07 24.27 351.87 42 37.10 1.394E+OO 5.747E-07 6.093E-07 26.19 785.83 ------ 1. 09 6.925E-01 ------ Line Not Found ------

839.00 ------ 0.59 6.497E-01 ------ Line Not Found ------

Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30296 Acquisition date 2-JUN-2014 09:51:46 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error RA-226 81. 07 ------ 0.18 1.383E+OO ------ Line Not Found ------

186.11 38 3.28* 2.042E+OO 3.996E-06 3. 996E-06 36.64 U-235 89. 96 ------ 3.36 l.657E+OO ------ Line Not Found ------

93.35 ------ 5.50 1. 743E+OO ------ Line Not Found ------

105.36 ------ 1. 98 1. 973E+OO ------ Line Not Found ------

109.18 ------ 1. 50 2.024E+OO ------ Line Not Found ------

143.79 ------ 10.50 2.177E+OO ------ Line Not Found ------

163.38 ------ 4.70 2 .133E+OO ------ Line Not Found ------

185.74 38 53.00* 2.042E+OO 2.473E-07 2.473E-07 36.64 194. 96 ------ 0.59 2.003E+OO ------ Line Not Found ------

202 .13 ------ 1. 00 1.970E+OO ------ Line Not Found ------

205.33 ------ 4.70 1. 956E+OO ------ Line Not Found ------

Flag: "*" Keyline

Minimum Detectable Activity Report Page : 7 Sample ID 30296 Acquisition date 2-JUN-2014 09:51:46 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)

BE-7 6. 477.61 8.7061E-07 MN-54 3. 834.83 1. 1135E-07 MN-56 5. 846.81 1. 5116E-07 C0-57 29. 122.06 1.0675E-07 C0-58 1. 810.79 8.4656E-08 C0-60 o. 1173.24 3.9650E-08 SB-124 3. 602.73 8.3775E-08 SB-125 8. 427.88 3.1326E-07 CS-134 4. 604. 71 9.6174E-08 CS-137 2. 661. 66 9.9240E-08