ML20034D958

From kanterella
Jump to navigation Jump to search
Salvage 12-10 - Health Physics Sample Records
ML20034D958
Person / Time
Site: San Onofre  
Issue date: 06/19/2014
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034D958 (10)


Text

Health Physics Sample Records Sample ID:

142483 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

1406038D 12, CAMP MESA# 12 Lg__o_!Tlmo_!1J Resp Org: P4000 - PROJECT MANAGEMEr

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

Q_rigin Mat. SizeNolume:

1307 GRAMS

==

Description:==

CAMP MESA# 12 1_c:<>11~~ionJ Sample Tech:

DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA lB_L_§SSj Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes Lh.~atis,_~J Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 06/05/1411:06 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/03/14 13:07 Sample SizeNolume: 1616 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

J,i' Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Other:

Material Loe:

06/19/2014 07:03 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Health Physics Sample Records


~

Sample ID:

142483 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 12, CAMP MESA# 12

~~}'_~i~J Geometry____ MCA ID Quant.

Units Method FP/AP A_ 1 L_marinelli_sand_

30366 1616GR

.000

_l~otop~ Mode Activity Activity U_~~~ LLD/MDA

%Abund.

0 K-40 NT 0.00001208 1.51 E-6 0

TL-208 NT 3.244E-7 7.83E-8 0

PB-212 NT 3.99E-7 9.58E-8 0

Bl-214 NT 6.807E-7 1.339E-7 0

PB-214 NT 7.974E-7 1.924E-7 0

BE-7 AP 7.8032E-7 0

MN-54 AP 1.0734E-7 0

MN-56 AP 1.3432E-7 0

C0-57 AP 9.0831E-8 0

C0-58 AP 1.0495E-7 0

C0-60 AP 4.2469E-8 0

SB-124 AP 9.8772E-8 0

SB-125 FP 2.2821E-7 0

CS-134 FP 1.0528E-7 0

CS-137 FP 1.4197E-7 L Analysis Review I Re-Analize:

No Hp Eng Rvw Reqd:

Yes Comments:

06/19/2014 07:03 r r r r Iv Iv

~

~

Iv Iv fi1"

~

~

Iv 84.585%

2.271%

2.794%

4.766%

5.583%

0.000%

0.000%

0.000%

0.000%

0.000%

0.000%

0.000%

0.000%

0.000%

0.000%

Lie Rad Mat Present:

No Rad Mat Present:

Yes Atom. No.

40 208 212 214 214 7

54 56 57 58 60 124 125 134 137 Lab Analysis By_

PARK, MICHAEL C Comments Reviewed: COOPER, TERRY L HP Notified Name:

Rasterized: r Date Mod ID Mod Date 06/05/1415:58 Mod Id Mod Date Date: 06/10/1414:57 Page 2 of 3

Sample ID:

142483 Type: RLSSS Type Detail: SAND

==

Description:==

140603BD 12, CAMP MESA# 12 I-Review/Approve I Reviewed: COOPER, TERRY L Comments: 338 keV peak is Ac-228 Health Physics Sample Records Status: APPROVED HP Review Date: 06/10/1415:35


~D.isposition ______________.

Disposition: OTHER Remarks:

---~----- -- ---~----------*

Approved: COOPER, TERRY L Comments:

06/19/2014 07:03 Result: Sample contains only natural isotopes

-~~~~~~~F_i_n_a_lA~pprova_l~~~~~~~~~~~~

Date: 06/10/14 15:35 Rasterized: r Page 3 of 3

SONGS HEALTH PHYSICS REPORT 5-JUN-2014 15:53

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140603BD 12, CAMP MESA# 12

  • ID 30366 Acquisition date: 5-JUN-2014 15:50:45. *
  • Start Time: 5-JUN-2014 15:50:00.
  • Stop Time: 5-JUN-2014 15:50:00.

Counting System U2GSP

  • Quantity 1.61600E+03 GR IHPS Sample Number: 142483
  • Geometry A lL marinelli_sand_l Analysis Library HP NATURAL Opera tor: MICHAEL PARK

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.42 0 00:03:00.46 0.0%
1. OOOOOE+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 5-JUN-2014 08:09:

2.12659E-01 4.99528E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

77.10 31 34

1. 00 153.92 151 7 36.1 1. 32E+OO BI-214 PB-212 PB-214 1

238. 71 39 16 1.14 477.44 474 7 24.0 3.85E+OO PB-212 1

2 95.14 29 5

1. 49 590.41 585 10 24.1 1.19E+OO PB-214 1

337.69 26 0

3.46 675.59 671 10 18.9 1.41E+OO 1

351.82 25 12 1.12 703.88 699 10 34.6 1.21E+OO PB-214 1

583.20 21 2

1. 58 1167.08 1163 8 24.1 5.88E-01 TL-208 1

609.25 34 3

1. 53 1219.23 1213 11 19.7 1. 66E-01 BI-214 1

1460.86 74 3

2.03 2924.06 2919 11 12.5 9.32E-01 K-40

Summary of Nuclide Activity Sample ID : 30366 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :

2 5-JUN-2014 15:50:45 Number of lines tentatively identified by NID 8

0 8

100.00%

Nuclide Type : natural Uncorrected Nuclide Hlife Decay uCi/GR K-40 1.2SE+09Y

1. 00 1.20SE-05 TL-208 3.05M
1. 64 1.9SOE-07 PB-212 10.64H
1. 00 3.981E-07 BI-214 19.90M
1. 08 6.295E-07 PB-214 26.BOM
1. 06 7.523E-07 Total Activity 1.406E-05 Grand Total Activity:

1.406E-05 Flags: "K" Keyline not found "E" = Manually edited Decay Corr Decay Corr 1-Sigma uCi/GR 1-Sigma Error

%Error 1.20SE-05 0.151E-05 12.51 3.244E-07 0.783E-07 24.13 3.990E-07 0.95SE-07 24.02 6.S07E-07 1.339E-07 19.67 7.974E-07

1. 924E-07 24.13
1. 429E-05 1.429E-05 Manually accepted "M"

"A" Nuclide specific abn. limit Flags A

A A

A A

Unidentified Energy Lines Sample ID : 30366 Page :

3 Acquisition date : 5-JUN-2014 15:50:45 It 1

Energy 337.69 Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err

%Eff Flags 26 0

3.46 675.59 671 10 1.44E-01 18.9 1.71E+OO T

Flags: "T" = Tentatively associated

Interference Report Sample ID : 30366 No interference correction performed Acquisition date Page :

4 5-JUN-2014 15:50:45

Nuclide Line Activity Report Page :

5 Sample ID : 30366 Acquisition date 5-JUN-2014 15:50:45 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 74 10.67*

5.314E-01 l.208E-05 1.208E-05 12.51 TL-208 72.80 2.14 1.594E+OO Line Not Found ------

74.97 3.60 1.692E+OO Line Not Found ------

84.79 ------

1. 27 2.058E+OO Line Not Found ------

252.45 ------

0.80 2.021E+OO Line Not Found ------

277.28 6.80

1. 920E+OO Line Not Found ------

510.61 ------

21. 60 l.265E+OO Line Not Found ------

583.02 21 86.00*

1.128E+OO l.980E-07 3.244E-07 24.13 763.06

1. 64 8.744E-01 ------

Line Not Found ------

860.30 ------

12.00 7.770E-Ol ------

Line Not Found ------

PB-212 74.81 ------

10.50 1.685E+OO Line Not Found ------

77.11 31 17.70 1.782E+OO 8.991E-07 9.013E-07 36.14 87.19 ------

6.27 2.129E+OO ------

Line Not Found ------

90.13 ------

1. 86 2.206E+OO Line Not Found ------

115.12 ------

0.59 2.535E+OO Line Not Found ------

238.58 39 43.60*

2.082E+OO 3.981E-07 3.990E-07 24.02 300.03 ------

3.34 1.834E+OO Line Not Found BI-214 76.86 31 0.58 1.782E+OO 2.744E-05 2.967E-05 36.14 79.29 ------

0.97

1. 869E+OO Line Not Found ------

609.31 34 46.10*

1.084E+OO 6.295E-07 6.807E-07 19.67 665.44

1. 56 9.985E-01 ------

Line Not Found ------

768.35 ------

4.88 8.685E-01 Line Not Found ------

806.16 ------

1. 23 8.283E-01 ------

Line Not Found ------

934.04 3.16 7.177E-01 Line Not Found ------

1120.27 ------

15.00 6.114E-01 Line Not Found ------

1155.18 ------

1. 69 5.973E-01 ------

Line Not Found ------

1238.11 ------

5.92 5.697E-01 ------

Line Not Found ------

1280.95 ------

1. 4 7 5.585E-Ol ------

Line Not Found ------

1377.66 ------

4.02 5.401E-01 Line Not Found ------

1385.30 ------

0.78 5.391E-01 ------

Line Not Found ------

1401.48 ------

1. 39 5.370E-01 ------

Line Not Found ------

1407.97 2.48 5.362E-01 ------

Line Not Found ------

1509.22 ------

2.19 5.292E-01 Line Not Found ------

1583.22 0.72 5.296E-01 ------

Line Not Found ------

1661. 26 ------

1.15 5.351E-01 Line Not Found ------

1729.58 ------

3.05 5.442E-01 Line Not Found ------

1764.49 ------

15.90 5.503E-01 Line Not Found ------

1847.41 ------

2.12 5.694E-01 ------

Line Not Found ------

PB-214 53.17 ------

1.10 5.543E-01 ------

Line Not Found ------

74.81 ------

6.52 1.685E+OO Line Not Found ------

77.11 31

11. 00 1.782E+OO 1.447E-06 1.533E-06 36.14 87.19 ------

3.88 2.129E+OO Line Not Found ------

90.13 ------

1.15 2.206E+OO Line Not Found ------

241. 92 7.46 2.067E+OO Line Not Found ------

258.94 0.55 l.994E+OO Line Not Found ------

295.09 29 19.20*

1.852E+OO 7.523E-07 7.974E-07 24.13 351. 87 25 37.10 1.662E+OO 3.718E-07 3.940E-07 34.61 785.83 ------

1. 09 8.495E-01 ------

Line Not Found ------

839.00 ------

0.59

7. 964E-01 Line Not Found ------

Nuclide Line Activity Report (continued)

Sample ID : 30366 Acquisition date Flag: "*"

Keyline Page :

6 5-JUN-2014 15:50:45

r l

Minimum Detectable Activity Report Page :

7 Sample ID 30366 Acquisition date 5-JUN-2014 15:50:45 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

4.

477.61 7.8032E-07 MN-54

2.

834.83 l.0734E-07 MN-56

3.

846.81 l.3432E-07 C0-57

16.

122.06 9.0831E-08 C0-58

2.

810.79

1. 0495E-07 C0-60
0.

1173.24 4.2469E-08 SB-124

0.

1690.98 9.8772E-08 SB-125

3.

427.88 2.2821E-07 CS-134

4.

604.71 l.0528E-07 CS-137

5.

661. 66 l.4197E-07