ML20034D952

From kanterella
Jump to navigation Jump to search
Salvage 2-10
ML20034D952
Person / Time
Site: San Onofre  
Issue date: 06/19/2014
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034D952 (10)


Text

Health Physics Sample Records Sample ID:

142478 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 7 CAMP MESA# 2 Common Resp Org: P4000 - PROJECT MANAGEMEt

Contact:

COOPER, TERRY L Reference ID:

Comments:

Reviewed: DYNES, WILLIAM J Comments:

Origin Mat. SizeNolume:

1611 GRAMS

==

Description:==

CAMP MESA# 2

@:ollection Sample Tech: DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA I.RLSSSl Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes fLocationl Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 06/05/14 09:25 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/03/1412:30 Sample SizeNolume: 1611 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

Iv' Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Other:

Material Loe:

06/19/2014 06:40 Rasterized:

Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Sample ID:

142478 Type: RLSSS Type Detail: SAND

==

Description:==

140603BD 7 CAMP MESA# 2 Analysis Geometry A_ 1 L_marinelli_sand_

MCA ID Quant.

Units 30357 1611 GR Method lsoto~ Mode Activity Activity Uncert.

LLD/MDA 0

K-40 NT 0

TL-208 NT 0

PB-212 NT 0

Bl-214 NT 0

PB-214 NT 0

BE-7 AP 0

MN-54 AP 0

MN-56 AP 0

C0-57 AP 0

C0-58 AP 0

C0-60 AP 0

SB-124 AP 0

SB-125 FP 0

CS-134 FP 0

CS-137 FP I Analysis Review j 0.00001237 1.43E-6 3.643E-7 6.97E-8 6.257E-7 9.59E-8 7.037E-7 1.209E-7 6.873E-7 1.985E-7 7.5113E-7 1.0782E-7 3.2475E-8 6.5814E-8 1.0143E-7 4.5904E-8 6.1358E-8 2.233E-7 8.0981E-8 7.9919E-8 r

r r r Iv"

~

Iv" w

~

?" w w

~

w Health Physics Sample Records Status: APPROVED FP/AP Lab Analysis ~y

.000 PARK, MICHAEL C

%Abund.

Atom. No.

Comments 83.859%

40 2.470%

208 4.242%

212 4.771%

214 4.659%

214 0.000%

7 0.000%

54 0.000%

56 0.000%

57 0.000%

58 0.000%

60 0.000%

124 0.000%

125 0.000%

134 0.000%

137 Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L HP Notified Name:

Hp Eng Rvw Reqd:

Yes Rad Mat Present:

Yes Comments:

06/19/2014 06:40 Rasterized: r Date Mod ID Mod Date 06/05/14 15:13 Mod Id Mod Date Date: 06/10/1414:40 Page 2 of 3

Sample ID:

142478 Type: RLSSS Type Detail: SAND

==

Description:==

1406038D 7 CAMP MESA# 2 I Review/Approve I Reviewed: COOPER, TERRY L Comments:

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/19/2014 06:40 Health Physics Sample Records Status: APPROVED Rasterized: J HP Eng Review Date: 06/10/1414:40 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/10/1414:40 Page 3 of 3

SONGS HEALTH PHYSICS REPORT 5-JUN-2014 15:02

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140603BD 7 CAMP MESA# 2

  • ID 30357 Acquisition date: 5-JUN-2014 14:59:24. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 5-JUN-2014 14:59:00.

5-JUN-2014 14:59:00.

Counting System 1.61100E+03 GR IHPS Sample Number:

A lL marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142478 HP NATURAL

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.44 0 00:03:00.49 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 5-JUN-2014 08:09:

2.12659E-01 4.99528E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1

77.31 32 26

1. 34 154.35 152 8 34.1 3.31E+OO BI-214 PB-212 PB-214 1

238.46 61 9

1. 00 476.95 473 7 15.3 3.03E+OO PB-212 1

295.02 25 9

1. 40 590.16 586 9 28.9 9.96E-01 PB-214 1

351. 7 5 32 8

1. 32 703.74 698 9 23.5 5.05E-01 PB-214 1

583.12 25 0

2.53 1166. 92 1162 9 19.1 4.95E-01 TL-208 1

609.19 35 0

1. 89 1219.11 1213 11 17.2 5.04E-01 BI-214 1

1460.95 75 0

2.35 2924.25 2917 13 11. 6 4.95E-01 K-40

Summary of Nuclide Activity Sample ID : 30357 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :

2 5-JUN-2014 14:59:24 Number of lines tentatively identified by NID 7

0 7

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 1.28E+09Y

1. 00
1. 237E-05
1. 237E-05 0.143E-05
11. 56 A

TL-208 3.05M

1. 52 2.402E-07 3.643E-07 0.697E-07 19.14 A

PB-212 10.64H

1. 00 6.244E-07 6.257E-07 0.959E-07 15.32 A

BI-214 19.90M

1. 07 6.584E-07 7.037E-07 1.209E-07 17.18 A

PB-214 26.80M

1. 05 6.542E-07 6.873E-07 l.985E-07 28.88 A

Total Activity l.454E-05

1. 4 7 5E-05 Grand Total Activity :

1.454E-05

1. 4 7 5E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30357 None Flags: "T" Tentatively associated Acquisition date Page :

3 5-JUN-2014 14:59:24

Interference Report Sample ID : 30357 No interference correction performed Acquisition date Page :

4 5-JUN-2014 14:59:24

I Nuclide Line Activity Report Page :

5 Sample ID : 30357 Acquisition date 5-JUN-2014 14:59:24 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 75 10.67*

5.314E-01 1.237E-05

1. 237E-05
11. 56 TL-208
72. 80 2.14 1.594E+OO ------

Line Not Found ------

74.97 3.60 l.692E+OO ------

Line Not Found ------

84.79 ------

1. 27 2.058E+OO Line Not Found ------

252.45 ------

0.80

2. 021E+OO Line Not Found ------

277.28 6.80 l.920E+OO Line Not* Found ------

510.61

21. 60 1.265E+OO Line Not Found ------

583.02 25 86.00*

1.128E+OO 2.402E-07 3.643E-07 19.14 763.06

1. 64 8.744E-01 ------

Line Not Found ------

860.30 12.00 7.770E-01 ------

Line Not Found ------

PB-212 74.81 10.50 1.685E+OO Line Not Found ------

77.11 32 17.70 1.791E+OO 9.337E-07 9.357E-07 34.12 87.19 ------

6.27 2.129E+OO Line Not Found ------

90.13

1. 86 2.206E+OO ------

Line Not Found ------

115. 12 ------

0.59 2.535E+OO Line Not Found ------

238.58 61 43.60*

2.083E+OO 6.244E-07 6.257E-07 15.32 300.03 ------

3.34 1.834E+OO Line Not Found ------

BI-214 76.86 32 0.58 1.791E+OO 2.850E-05 3.045E-05 34.12 79.29 ------

0.97 l.869E+OO Line Not Found ------

609.31 35 46.10*

1.084E+OO 6.584E-07 7.037E-07 17.18 665.44

1. 56 9.985E-01 ------

Line Not Found ------

768.35 4.88 8.685E-01 ------

Line Not Found ------

806.16 ------

1. 23 8.283E-01 ------

Line Not Found ------

934.04 ------

3.16 7..177E-01 Line Not Found ------

1120.27 15.00 6.114E-01 Line Not Found ------

1155.18

1. 69 5.973E-01 Line Not Found ------

1238.11 ------

5.92 5.697E-01 Line Not Found ------

1280.95 ------

1. 47 5.585E-01 Line Not Found ------

1377. 66 4.02 5.401E-01 Line Not Found ------

1385.30 ------

0.78 5.391E-01 Line Not Found ------

1401.48

1. 39 5.370E-01 Line Not Found ------

1407.97 2.48 5.362E-01 Line Not Found ------

1509.22 2.19 5.292E-01 Line Not Found ------

1583.22 0.72

5. 296E-01 Line Not Found ------

1661. 26 1.15 5.351E-01 Line Not Found ------

1729.58 3.05 5.442E-01 Line Not Found ------

1764.49 ------

15.90 5.503E-01 Line Not Found ------

1847.41 ------

2.12 5.694E-01 ------

Line Not Found ------

PB-214 53.17 1.10 5.543E-01 ------

Line Not Found ------

74.81 ------

6.52 l.685E+OO Line Not Found ------

77.11 32

11. 00
1. 791E+OO 1.502E-06 1.579E-06 34.12 87.19 ------

3.88 2.129E+OO Line Not Found ------

90.13 1.15 2.206E+OO Line Not Found ------

241.92 7.46 2.067E+OO Line Not Found ------

258.94 0.55 1.994E+OO ------

Line Not Found ------

295.09 25 19.20*

1.853E+OO 6.542E-07 6.873E-07 28.88 351. 87 32 37.10 1.662E+OO 4.898E-07 5.146E-07 23.49 785.83

1. 09 8.495E-01 Line Not Found ------

839.00 0.59

7. 964E-01 Line Not Found ------
  • J I

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30357 Acquisition date 5-JUN-2014 14:59:24 Flag: "*"

Keyline

Minimum Detectable Activity Report Page :

7 Sample ID 30357 Acquisition date 5-JUN-2014 14:59:24 Bck:gnd Energy MDA Nuclide Sum

( k:eV)

(uCi/GR)

BE-7

3.

477.61

7. 5113E-07 MN-54
2.

834.83 l.0782E-07 MN-56

0.

846.81 3.2475E-08 C0-57

8.

122.06

6. 5814E-*08 C0-58
2.

810.79 l.0143E-07 C0-60

0.

1332.50 4.5904E-08 SB-124

1.

602.73 6.1358E-08 SB-125

3.

427.88 2.2330E-07 CS-134

2.

604.71 8.0981E-08 CS-137

1.

661.66 7.9919E-08