Chris Ahola, CHP Radiation Protection Manager

May16,2016 Ms.PoonamAcharya ProjectManager DepartmentofToxicSubstancesControl 5796CorporateAvenue Cypress,CA90630

Subject:

SanOnofreNuclearGeneratingStation(SONGS)MesaFacilityRequestfor RadiologicalAssessment

DearMs.Acharya,

ThisletterrespondstoonerequestinyourletterdatedFebruary16,2016toMs.

PhuongTranofSouthernCaliforniaEdisonCompany(SCE)regardingtheactivitiesassociated withtheVoluntaryCleanupAgreementfortheSONGSMesaFacility,Parcels5,6,and7(the MesaFacility).Inaddition,yourletterrequeststhatSCEperformaradiologicalassessmentof theMesaFacilityduetoitsproximityandsupportingoperationstotheSONGSplantsite.You alsorecommendedthattheNuclearRegulatoryCommission(NRC)andtheCalifornia DepartmentofPublicHealth(DPH)becontactedtoreviewandapprovetheradiationrelated assessments.1Inresponse,thislettersubmitsradiologicalassessmentscompletedfortheMesa Facility.AlsoprovidedistheNRCcorrespondencethatsupportsthefindingsinthose assessments.Theseradiologicalassessmentsdemonstratethat:

1.ReportsproducedfortheSONGSRadiologicalEnvironmentalMonitoringProgram (REMP)demonstratethatnodetectableradioactivecontaminationfromSONGS plantrelatedactivitiesisattheMesaFacilityorthesurroundingareas.

2.NodetectableradioactivecontaminationfromSONGSplantrelatedactivitiesis presentontheMesaFacilityfrommaterialinadvertentlytransferredtotheMesa Facility.

TheradiologicalassessmentdocumentsarecontainedoneachoftheenclosedtwoCDsandare summarizedbelow.

AnnualRadiologicalEnvironmentalOperatingReport SCEinstitutedtheradiologicalenvironmentalmonitoringrequiredbyNRCandU.S.

EnvironmentalProtectionAgencyregulationsonanannualbasissincetheSONGSplantsstarted operating.TheREMPobjectiveistoprovidemeasurementsofSONGSplantrelated radionuclidesintheareassurroundingtheplantandmonitoringofpotentialexposure

1YourMarch23,2016letteralsorequestedthatRadiologicalassessmentfortheMesaFacilityshouldbe completedandapprovedbytheNRCand/orCDPHpriortoclosureofParcel5.

Ms.PoonamAcharya May16,2016 Page2of4

pathways.TheAnnualRadiologicalEnvironmentalOperatingReports(AREOR)documentthe comprehensivemonitoringundertakentodemonstratethenegligibleimpactofSONGS operationonthelocalenvironment.CDTabs1through5arethe2015through2011AREORs, respectively.2 Preoperational3samplingwasperformedatcontrollocationsbothwithintheSONGSplant areaandwellawayfromtheSONGSarea4.Thepreoperationalsamplingidentifiedradioactive materialprimarilyduetoweaponstestingatlocationsawayfromtheSONGSplant.Subsequent testinghasalsoshowntheeffectsoftheChernobylandFukushimaincidents.Sampling pathwaysconsistofair,drinkingwater,oceanwater,fish,crustaceans,soil/sediment,sand, kelp,localcropsanddirectradiation.5Theenclosedreports,andpastAREORs,haveshownthat SONGSplantrelatedactivitieshavecausednodetectableradioactivecontamination.Several REMPdatacollectionstationsarelocatedontheMesaFacility,includinganairsampler,local gardenforcropsanddirectradiationmonitoringstations,whichdirectlycorrelatetoa conclusionofnodetectableradioactivecontaminationontheMesaFacilityfromSONGSplant relatedactivities.

MesaFacilitySpecificRadiologicalAssessment Duringthe1980s,somelimitedradiologicalmaterialwasinadvertentlytransferredfromthe SONGSplantsitetotheMesaFacility.Theradiologicalmaterialwasprimarilycontaminationon toolsandequipment.AstheSONGSNRCLicensedidnotallowforthecontaminatedmaterial tobeontheMesaFacility,upondiscoveryofcontaminatedmaterial,suchmaterialwas immediatelysecured,transferredbacktotheappropriatelocationwithintheSONGSplantarea, andtheMesaFacilityareawasverifiedtohavenodetectableradioactivecontaminationfrom thismaterial.

AttherequestoftheDepartmentoftheNavy(DoN),6theNRCsentaDecember1,2015letter toCommanderFletcheroftheDoN(CDTab12)affirmingthatSCEappropriatelyaddressedand remediatedtheseincidents,assupportedbytheNRCsInspectionReport(IR)#50206/8102 (CDTab13).FurthersupportthattheMesaFacilitydoesnothavedetectableradioactive contaminationfromSONGSplantrelatedactivitiesisshowninthedocumentationonthe enclosedCD.CertifiedHealthPhysicistshiredbySCEpreparedmemoranda(CDTabs710) thatdiscuss(i)theassessmentoftheincidentswhenradiologicalmaterialwasinadvertently transferredtotheMesaFacilityareafromtheSONGSplant,(ii)howtheincidentswere addressedandremediated,ifneeded,and(iii)thestepstaken,includingadditionalsurveys,to

2LinktoSCEAREORsatNRCswebsite:http://www.nrc.gov/reactors/operating/opsexperience/tritium/plant specificreports/sano23.html 3PriortotheoperationofSONGSUnit1in1968.

4TheAREORsidentifythesamplinglocations.

5SplitsamplingisperformedwiththeDPH.

6TheMesaFacilityislocatedonDoNland.

Ms.PoonamAcharya May16,2016 Page3of4

showthatnodetectableradioactivecontaminationremainedonParcels5,6,and7duetosuch incidents.

ConclusionRegardingRadiologicalContaminationontheMesa

TheREMPAREORs(currentandhistorical)showthatSONGSplantrelatedactivitieshavenot causedanydetectableradioactivecontaminationontheMesaFacilitythroughanalysisof environmentalmedia,suchassoil,air,andwater.Additionally,theareaswhereradioactive materialwasinadvertentlybroughttotheMesaFacilityhavebeenfullyremediatedandsurveys wereconductedtodemonstratethatnodetectableradioactivecontaminationfromSONGS plantrelatedactivitiesisontheMesaFacility.

ContactwithNRCandDPH

Asnotedabove,similartotheDTSCsrequestthatSCEcontacttheNRCregardingtheMesa Facilityradiationrelatedassessment,theDoNhadpreviouslyrequestedtheNRCprovidean opinionregardingdetectableradioactivecontaminationontheMesaFacilityfromtheincidents mentionedabove.TheNRCsDecember1,2015letter(CDTab12)indicatesthatSCEhas appropriatelyaddressedandremediatedanySONGSplantrelatedradioactivematerials contamination,alsocitingtotheSONGSREMP.Thus,asnodetectableradioactive contaminationfromSONGSplantrelatedactivitiesisattheMesaFacility,theNRCconcludes thattheMesaFacilityisnotsubjecttoNRClicensing.SCEhasbrieflydiscussedtheDTSCrequest withDPHrepresentatives,whohaveinformedSCEthatDPHwillrespondtoaDTSCrequestfor reviewoftheinformationenclosedwiththisletter.SCEhascopiedDPHonthistransmittal.In lightoftheenclosedinformation,includingtheNRCsDecember1,2015letter,ifDTSCbelieves thatDPHsreviewisnolongernecessary,pleaseletmeknow.

WewouldbepleasedtodiscusstheradiologicalassessmentswithyouandotherDTSCstaff.

Shouldyouhaveanyquestions,pleasecontactMr.BrianMetzat949.368.7311.

Sincerely,

ChrisAhola,CHP RadiationProtectionManager

cc:

GonzaloPerez,DPH,ChiefRadiologicalHealthBranch

NinoMascolo,SCE

StevieVaughan,SCE

BrianMetz,SCE

PhuongTran,SCE

Ms.PoonamAcharya May16,2016 Page4of4

ListofdocumentscontainedwithineachenclosedCD

Tab Document 1

SONGS2015AnnualRadiologicalEnvironmentalOperatingReport(AREOR) 2 SONGS2014AnnualRadiologicalEnvironmentalOperatingReport(AREOR) 3 SONGS2013AnnualRadiologicalEnvironmentalOperatingReport(AREOR) 4 SONGS2012AnnualRadiologicalEnvironmentalOperatingReport(AREOR) 5 SONGS2011AnnualRadiologicalEnvironmentalOperatingReport(AREOR) 6 DTSCFebruary16,2016lettertoSCErequestingaradiologicalassessmentofMesa LeaseParcels5,6,and7 7

May28,2015MemotoFile(amendingApril10,2014MemotoFile)Assessing RadiologicalEventsattheMesaandrecommendingadditionalsurveys 8

April11,2014AddendumtoMemotoFileregardingAdequacyof1981Radiological SurveysforMesaLocationsaandb 9

April30,2014MesaSurveyPlan.Describestheplanforconductingthesurveysfor residualcontaminationontheMesa 10 July2,2014MemotoFileregardingResultsofConfirmatoryRadiologicalSurveyat theMesasummarizingsurveyresultstoconfirmnoevidenceispresentofdetectable radioactivecontaminationcomparedtobackground 11 SurveysthatdocumentthetoolsandequipmentlocatedontheMesapriortotheir salewerenotcontaminated 12 December1,2015letterfromU.S.NuclearRegulatoryCommissiontoCommander DouglasFletcher,DepartmentofNavy 13 February13,1981letterfromU.S.NuclearRegulatoryCommissiontoSCE.

a. InspectionReport50206/8102