ML20034E189
Text
Sample ID:
142502 Type: RLSSS Type Detail: SAND
==
Description:==
14060614BD 02 NORTH LAYDOWN #2
!Common!
Resp Org: P4000 - PROJECT MANAGEMEt
Contact:
COOPER, TERRY L Reference ID:
Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:
I orfgin~I Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Unknown Mat:
NO Date: 06/09/14 08:05 Mat. SizeNolume:
2159 GRAMS Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00
==
Description:==
NORTH LA YDOWN # 2 I Collection I Sample Tech:
DYNES, WILLIAM J Tritium Req:
No Instructions:
COUNT TO MDA Comments:
COUNT TO MDA
[ RLSSS.I Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
Yes I Location I Unit: NON-UNIT RE Stored By:,
Sample Loe:
Area: MS Other: COUNT TO MDA Material Loe:
06/19/2014 08:55 Sample Date: 06/06/14 09:05 Sample SizeNolume: 2159 GRAMS Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
?"
Elev: 100 Room:
Depth:
(in.)
Equip ID:
Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of 3
Sample ID:
142502 Type: RLSSS Type Detail: SAND Health Physics Sample Records
- -----~
Status: APPROVED
==
Description:==
140606148D 02 NORTH LAYDOWN #2
[Analysis I Geometry MCAID Quant Units Method FP/AP C_ 1 L_marinelli_sand_
30422 Isotope Mode Activity 0
K-40 NT 9.949E-6 0
TL-208 NT 3.145E-7 0
PB-212 NT 5.323E-7 0
81-214 NT 4.563E-7 0
PB-214 NT 6.85E-7 0
AC-228 NT 8.225E-7 0
BE-7 AP 6.876E-7 0
MN-56 AP 8.1524E-8 0
C0-57 AP 6.5035E-8 0
C0-58 AP 6.0999E-8 0
C0-60 AP 9.0202E-8 0
SB-124 AP 6.8431E-8 0
SB-125 FP 2.2988E-7 0
CS-134 FP 8.8027E-8 0
- Analysis Review I Re-Analize:
No Hp Eng Rvw Reqd:
Yes Comments:
06/19/2014 08:55 2159GR
.000 Activity Uncert.
LLD/MDA
%Abund.
1.072E-6 r
77.973%
6.83E-8 r
2.465%
9.33E-8 r
4.172%
1.15E-7 r
3.576%
1.303E-7 r
5.369%
1.87E-7 r
6.446%
w 0.000%
w 0.000%
~
0.000%
~
0.000%
w 0.000%
w 0.000%
~
0.000%
~
0.000%
w 0.000%
w 0.000%
Lie Rad Mat Present:
No Rad Mat Present:
Yes Atom. No.
40 208 212 214 214 228 7
54 56 57 58 60 124 125 134 137 Lab Analysis By NEEBE, DAVID J Comments Reviewed: COOPER, TERRY L HP Notified Name:
Rasterized: r Date Mod ID Mod Date 06/09/14 20:28 Mod Id Mod Date Date: 06/11/14 07:31 Page2 of3
Sample ID:
142502 Type: RLSSS Type Detail: SAND
==
Description:==
14060614BD 02 NORTH LAYDOWN #2 r Review/Approvel Reviewed: COOPER, TERRY L Comments:
Disposition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/19/2014 08:55 Health Physics Sample Records Status: APPROVED Rasterized: r HP Review Date: 06/11/14 07:31 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/11/14 07:32 Page 3 of 3
SONGS HEALTH PHYSICS REPORT 9-JUN-2014 20:20
- Title
>>>>> SAMPLE PARAMETERS<<<<<
14060614BD 02 NORTH LAYDOWN #2
- ID 30422 Acquisition date: 9-JUN-2014 20:17:14. *
- Start Time:
- Stop Time:
- Quantity
- Geometry 9-JUN-2014 20:17:00.
9-JUN-2014 20:17:00.
Counting System 2.15900E+03 GR IHPS Sample Number:
C 11 marinelli_sand_l Analysis Library Operator: DAVID NEEBE U2GSP 142502 HP NATURAL
>>>>> C #41-TP11750A PARAMETERS<<<<<
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.42 0 00:03:00.47 0.0%
1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 9-JUN-2014 19:38:
-l.08890E-01 4.99807E-01
- 1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1
238. 72 69 22
- 1. 23 477.82 473 9 17.5 1.58E+OO PB-212 1
295.24 34 2
- 1. 75 590.88 586 9 19.0 5.46E-01 PB-214 1
338.54 13 8
- 1. 59 677.50 673 8 46.5 3.75E-01 AC-228 1
351.67 42 7
- 1. 46 703.78 699 9 19.3 1. 43E+OO PB-214 1
583.. 29 31 2
- 1. 70 1167.10 1163 10 21. 7 2.75E+OO TL-208 1
609.16 32 9
- 1. 91 1218.85 1213 12 25.2 1.19E+OO BI-214 1
911. 29 26 4
2.21 1823.14 1819 8 22.7 3.13E-01 AC-228 1
1460.89 85 0
2.12 2922.19 2916 12 10.8 2.02E-01 K-40
Summary of Nuclide Activity Sample ID : 30422 Total number of lines in spectrum Number of unidentified lines Page :
2 Acquisition date 9-JUN-2014 20:17:14 Number of lines tentatively identified by NID 8
0 8
100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error Flags K-40 1.28E+09Y
- 1. 00 9.949E-06 9.949E-06 1.072E-06 10.77 A
TL-208 3.05M
- 1. 46 2.159E-07 3.145E-07 0.683E-07
- 21. 73 A
PB-212 10.64H
- 1. 00 5.313E-07 5.323E-07 0.933E-07 17.53 A
BI-214 19.90M
- 1. 06
- 4. 2 96E-07 4.563E-07 1.150E-07 25.20 A
PB-214 26.BOM
- 1. 05 6.550E-07 6.850E-07 l.303E-07 19.03 A
AC-228 6.13H
- 1. 00 8.198E-07 B.225E-07 l.870E-07 22.73 A
Total Activity
- 1. 2 60E-05
- 1. 276E-05 Grand Total Activity :
- 1. 2 60E-05
- 1. 276E-05 Flags: "K" Keyline not found "M"
Manually accepted "E"
Manually edited "A"
Nuclide specific abn. limit
Unidentified Energy Lines Sample ID : 30422 None Flags: "T" Tentatively associated Acquisition date Page :
3 9-JUN-2014 20:17:14
Interference Report Sample ID : 30422 No interference correction performed Acquisition date Page :
4 9-JUN-2014 20:17:14
Nuclide Line Activity Report Page :
5 Sample ID : 30422 Acquisition date 9-JUN-2014 20:17:14 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 85 10.67*
5.560E-01 9.949E-06 9.949E-06 10.77 TL-208 72.80 ------
2.14 1.486E+OO Line Not Found ------
74.97 ------
3.60 1.577E+OO Line Not Found ------
84.79 ------
- 1. 27 l.917E+OO Line Not Found ------
252.45 ------
0.80 2.004E+OO Line Not Found ------
277.28 6.80 1.917E+OO ------
Line Not Found ------
510.61 ------
- 21. 60 l.298E+OO Line Not Found ------
583.02 31 86.00*
1.157E+OO 2.159E-07 3.145E-07
- 21. 73 763.06 ------
- 1. 64 8.934E-01 Line Not Found ------
860.30 ------
12.00 7.922E-01 Line Not Found ------
PB-212 74.81 ------
10.50 l.570E+OO Line Not Found ------
77.11 ------
17.70 1.661E+OO Line Not Found ------
87.19 ------
6.27
- 1. 983E+OO Line Not Found ------
90.13
- 1. 86 2.055E+OO Line Not Found ------
115.12 ------
0.59 2.376E+OO ------
Line Not Found ------
238.58 69 43.60*
2.055E+OO 5.313E-07 5.323E-07 17.53 300.03 ------
3.34 l.843E+OO Line Not Found ------
BI-214 7 6. 8 6 0.58 l.651E+OO Line Not Found ------
79.29 ------
0.97
- 1. 741E+OO ------
Line Not Found ------
609.31 32 46.10*
- 1. 112E+OO 4.296E-07 4.563E-07 25.20 665.44
- 1. 56
- 1. 023E+OO Line Not Found ------
768.35 ------
4.88 8.873E-01 ------
Line Not Found ------
806.16 ------
- 1. 23 8.454E-01 ------
Line Not Found ------
934.04 ------
3.16 7.310E-01 ------
Line Not Found ------
1120.27 15.00 6.242E-01 ------
Line Not Found ------
1155.18 ------
- 1. 69 6.105E-01 Line Not Found ------
1238.11 ------
5.92 5.846E-01 Line Not Found ------
1280.95 ------
- 1. 47 5.747E-01 Line Not Found ------
1377.66 ------
4.02 5.602E-01 Line Not Found ------
1385.30 ------
0.78 5.595E-01 Line Not Found ------
1401.48 ------
- 1. 39 5.583E-01 Line Not Found ------
1407.97 2.48 5.578E-01 ------
Line Not Found ------
1509.22 ------
2.19 5.568E-01 ------
Line Not Found ------
1583.22 ------
0.72 5.628E-01 ------
Line Not Found ------
1661.26 ------
1.15 5.753E-Ol ------
Line Not Found ------
1729.58 ------
3.05 5.918E-01 Line Not Found ------
1764.49 ------
15.90 6.023E-01 ------
Line Not Found ------
1847.41 ------
2.12 6.331E-01 ------
Line Not Found ------
PB-214 53.17 1.10 5.203E-01 Line Not Found ------
74.81 6.52 1.570E+OO Line Not Found ------
77.11 ------
- 11. 00 1.661E+OO Line Not Found ------
87.19 ------
3.88 1.983E+OO Line Not Found ------
90.13 1.15 2.055E+OO Line Not Found ------
241.92
- 7. 4 6 2.043E+OO Line Not Found ------
258.94 0.55
- 1. 981E+OO Line Not Found ------
295.09 34 19.20*
- 1. 858E+OO 6.550E-07 6.850E-07 19.03 351.87 42 37.10 l.687E+OO 4.672E-07 4.887E-07 19.31 785.83 ------
- 1. 09 8.674E-01 Line Not Found ------
839.00 ------
0.59 8.122E-01 Line Not Found ------
I Nuclide Line Activity Report (continued)
Page :
6 Sample ID : 30422 Acquisition date 9-JUN-2014 20:17:14 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error AC-228
- 89. 96 ------
3.40 2.051E+OO Line Not Found ------
93.35 ------
5.60 2.124E+OO Line Not Found ------
99.55 ------
- 1. 30 2.229E+OO Line Not Found ------
105.36 ------
2.00 2.301E+OO Line Not Found ------
108.99 ------
0.67 2.335E+OO Line Not Found ------
129.03 ------
2.90 2.414E+OO Line Not Found ------
153.89 ------
0.84 2.377E+OO Line Not Found ------
209.39 ------
4.10 2.168E+OO Line Not Found ------
216.24 0.80 2.141E+OO Line Not Found ------
270.26 ------
3.80 1.941E+OO Line Not Found ------
328.07 ------
3.50 1.756E+OO Line Not Found ------
338.42 13 12.40 1.725E+OO 4.124E-07 4.137E-07 46.55 340.94 ------
0.52 1.718E+OO Line Not Found ------
409.62 ------
2.20 1.531E+OO ------
Line Not Found ------
463.10 ------
4.60 1.401E+OO Line Not Found ------
562.65 ------
- 1. 01 1.195E+OO Line Not Found ------
581. 52 3.00 1.160E+OO ------
Line Not Found ------
726.63 ------
0.87 9.382E-01 ------
Line Not Found ------
755.28 ------
- 1. 32 9.027E-01 ------
Line Not Found ------
772. 28
- 1. 09 8.827E-01 ------
Line Not Found ------
782.12 ------
0.59
- 8. 716E-01 -------
Line Not Found ------
794.79 ------
4.60 8.576E-01 ------
Line Not Found ------
830.59 ------
0.63 8.205E-01 ------
Line Not Found ------
835.60 ------
- 1. 71 8.155E-01 ------
Line Not Found ------
840.44 0.94 8.108E-01 ------
Line Not Found ------
904.29 ------
0.89 7.542E-Ol Line Not Found ------
911.16 26 29.00*
7.486E-01 8.198E-07 8.225E-07 22.73 964.64 5.80 7.091E-01 ------
Line Not Found ------
968.97 ------
17.40 7.06).E-01 ------
Line Not Found ------
1246.60 ------
0.57 5.825E-01 ------
Line Not Found ------
1459.19 ------
- 1. 06 5.560E-01 ------
Line Not Found ------
1496.00 ------
- 1. 05 5.563E-01 ------
Line Not Found ------
1501. 44 0.58 5.565E-01 ------
Line Not Found ------
1580.30 ------
- 0. 71 5.624E-01 ------
Line Not Found ------
1588.23 ------
3.60 5.634E-01 ------
Line Not Found ------
1630.47
- 1. 95 5, 696E-01 ------
Line Not Found ------
1638.10 ------
0.54 5.709E-01 ------
Line Not Found ------
Flag: "*" = Keyline
Minimum Detectable Activity Report Page :
7 Sample ID 30422 Acquisition date 9-JUN-2014 20:17:14 Bckgnd Energy MDA Nuclide Sum (keV)
(uCi/GR)
BE-7
- 6.
477.61 6.8760E-07 MN-54
- 2.
834.83 7.8889E-08 MN-56
- 2.
846.81 8.1524E-08 C0-57
- 13.
122.06 6.5035E-08 C0-58
- 1.
810.79 6.0999E-08 C0-60
- 1.
1332.50 9.0202E-08 SB-124
- 0.
1690.98 6.8431E-08 SB-125
- 6.
427.88 2.2988E-07 CS-134
- 2.
795.87 8.8027E-08 CS-137
- 5.
661.66 1.0562E-07