Health Physics Sample Records Sample ID: 142490 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

1406058001 SOUTH LAY DOWN# 2 ICommonl Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N

Contact:

COOPER, TERRY L Survey No:

Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 06/06/14 07:11 Comments:

[:=_oiiiiJBJ Mat. SizeNolume: 1955 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00

Description:

SOUTH LAY DOWN # 2 Collection Sample Tech: DYNES, WILLIAM J Sample Date: 06/05/1412:50 Count Time: 900 (secs.)

Tritium Req: No Sample SizeNolume: 1955 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA I RLSSSj Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: fv'"

ILocation Unit: NON-UNIT RE Area: MS E.lev: 100 Room: Depth: (in.) Equip ID:

Stored By:, Date: 00/00/00 00:00 Sample Loe:

Other: COUNT TO MDA Material Loe:

06/19/2014 09:52 Page 1 of 3

Health Physics Sample Records Sample ID: 142490 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140605BD01 SOUTH LAY DOWN# 2

=

Analysis Geometry ______ MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date C_ 1L_ marinelli_sand- 30382 1955GR .000 LYLE, OWEN M 06/06/14 13:58 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.000011741.31E-6 r 77.589% 40 0 TL-208 NT 3.269E-7 7.41E-8 r 2.160% 208 0 PB-212 NT 5.745E-7 1.108E-7 r 3.797% 212 0 81-214 NT 5.083E-7 1.461E-7 r 3.359% 214 0 PB-214 NT 8.074E-7 2.101E-7 r 5.336% 214 0 AC-228 NT 1.174E-6 2.51E-7 r 7.759% 228 0 BE-7 AP 6.1272E-7 Iv' 0.000% 7 0 MN-54 AP 9.2108E-8 ~ 0.000% 54 0 MN-56 AP 7.1547E-8 p- 0.000% 56 0 C0-57 AP 7.6542E-8 Iv' 0.000% 57 0 C0-58 AP 2.4757E-8 Iv' 0.000% 58 0 C0-60 AP 1.3737E-7 w 0.000% 60 0 SB-124 AP 7.5023E-8 (v' 0.000% 124 0 SB-125 FP 1.5973E-7 w 0.000% 125 0 CS-134 FP 6.9217E-8 w 0.000% 134 0 CS-137 FP 9.4633E-8 w 0.000% 137

[ Analysis Review I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/11/14 06:25 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:

Comments:

06/19/2014 09:52 Page 2 of 3

Health Physics Sample Records Sample ID: 142490 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140605BD01 SOUTH LAY DOWN# 2 I Review/Approve I HP Review Reviewed: COOPER, TERRY L Date: 06/11/14 06:25 Comments:

Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:

Final Approval Approved: COOPER, TERRY L Date: 06/11/14 06:25 Comments:

06/19/2014 09:52 Page 3 of 3

  • SONGS HEALTH PHYSICS REPORT 6-JUN-2014 13:54 *
  • >>>>> SAMPLE PARAMETERS<<<<< *
  • Title 140605BD01 SOUTH LAY DOWN# 2 *
  • ID 30382 Acquisition date: 6-JUN-2014 13:50:55. *
  • Start Time: 6-JUN-2014 13:50:00. *
  • Stop Time: 6-JUN-2014 13:50:00. Counting System U2GSP *
  • Quantity 1.95500E+03 GR IHPS Sample Number: 142490 *
  • Geometry C 11 marinelli - sand- 1 Analysis Library HP NATURAL *
  • Operator: OWEN LYLE *
  • >>>>> C #41-TP11750A PARAMETERS<<<<< *
  • Elapsed Live Time 0 00:03:00.46 Calibration 5-JUN-2014 19:42: *
  • Elapsed Real Time 0 00:03:00.50 Energy Offset -l.03481E-01 *
  • Deadtime 0.0% Energy Slope 4.99812E-01 *
  • Activity Mult Factor: 1. OOOOOE+OO Energy Tolerance: 1. 00000 *
  • Half Life Ratio 8.00000 Sensitivity 5.00000
  • Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 77.34 24 44 1. 25 154.94 152 7 51.1 2.80E+OO BI-214 PB-212 PB-214 1 209.28 25 11 1. 57 418.91 416 8 33.2 1.91E+OO AC-228 1 238.61 67 33 1.12 477.59 473 11 19.3 2.18E+OO PB-212 1 295.40 35 15 1. 23 591.19 588 9 26.0 l.64E+OO PB-214 1 338.20 23 9 2.43 676.82 673 9 29.9 1.0lE+OO AC-228 1 351.99 38 8 1. 28 704.40 699 11 22.4 4.98E-01 PB-214 1 582.87 25 2 1. 97 1166. 27 1162 8 22.7 l.55E+OO TL-208 1 609.33 31 11 1. 47 1219.20 1213 14 28.7 2.82E-01 BI-214 1 968. 85 19 0 2.21 1938.29 1934 8 21. 3 1. 73E-01 AC-228 1 1460.97 91 3 1. 95 2922.47 2917 11 11. 2 1. 23E+OO K-40

Summary of Nuclide Activity Page : 2 Sample ID : 30382 Acquisition date 6-JUN-2014 13:50:55 Totai number of lines in spectrum 10 Number of unidentified lines 0 Number of lines tentatively identified by NID 10 100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y l. 00 1.174E-05 l.174E-05 0.131E-05 11. 20 A TL-208 3.05M l. 70 1. 9l9E-07 3.269E-07 0.741E-07 22.68 A PB-212 10.64H l. 00 5.730E-07 5.745E-07 l.108E-07 19. 29 A BI-214 19.90M l. 09 4.672E-07 5.083E-07 l. 4 61E-07 28.75 A PB-214 26.80M 1. 06 7.584E-07 8.074E-07 2.lOlE-07 26.03 A AC-228 6.13H l. 00 l.169E-06 l.174E-06 0.251E-06 21. 33 KA Total Activity 1.490E-05 1.513E-05 Grand Total Activity : 1.490E-05 l.513E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit

Unidentified Energy Lines Page : 3 Sample ID : 30382 Acquisition date 6-JUN-2014 13:50:55 None Flags: "T" Tentatively associated

Interference Report Page : 4 Sample ID : 30382 Acquisition date 6-JUN-2014 13:50:55 No interference correction performed

Nuclide Line Activity Report Page : 5 Sample ID : 30382 Acquisition date 6-JUN-2014 13:50:55 Nuclide 'l'ype: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 91 10.67* 5.560E-01 1.174E-05 1.174E-05 11. 20 TL-208 72.80 ------ 2.14 1.486E+OO ------ Line Not Found ------

74.97 ------ 3.60 l.577E+OO ------ Line Not Found ------

84.79 ------ 1. 27 1.917E+OO ------ Line Not Found ------

252.45 ------ 0.80 2.004E+OO ------ Line Not Found ------

277.28 ------ 6.80 l.917E+OO ------ Line Not Found ------

510.61 ------ 21. 60 1.298E+OO ------ Line Not Found ------

583.02 25 86.00* 1.158E+OO 1.919E-07 3.269E-07 22.68 763.06 ------ 1. 64 8.934E-01 ------ Line Not Found ------

860.30 ------ 12.00 7.922E-01 ------ Line Not Found ------

PB-212 74.81 ------ 10.50 1.570E+OO ------ Line Not Found ------

77 .11 24 17.70 1. 669E+OO 6.242E-07 6.258E-07 51.15 87.19 ------ 6.27 1.983E+OO ------ Line Not Found ------

90.13 ------ 1. 86 2.055E+OO ------ Line Not Found ------

115 .12 ------ 0.59 2.376E+OO ------ Line Not Found ------

238.58 67 43.60* 2.055E+OO 5.730E-07 5.745E-07 19.29 300.03 ------ 3.34 1.843E+OO ------ Line Not Found ------

BI-214 76. 86 24 0.58 1.669E+OO 1.905E-05 2.072E-05 51.15 79.29 ------ 0.97 1.741E+OO ------ Line Not Found ------

609.31 31 46.10* 1.112E+OO 4.672E-07 5.083E-07 28.75 665.44 ------ 1. 56 1.023E+OO ------ Line Not Found ------

768.35 ------ 4. 88 8.873E-01 ------ Line Not Found ------

806.16 ------ 1. 23 8.454E-01 ------ Line Not Found ------

934.04 ------ 3.16 7.310E-Ol ------ Line Not Found ------

1120. 27 ------ 15.00 6.242E-01 ------ Line Not Found ------

1155 .18 ------ 1. 69 6.105E-01 ------ Line Not Found ------

1238 .11 ------ 5.92 5.846E-01 ------ Line Not Found ------

1280.95 ------ 1. 47 5.747E-01 ------ Line Not Found ------

1377.66 ------ 4.02 5.602E-01 ------ Line Not Found ------

1385.30 ------ 0.78 5.595E-01 ------ Line Not Found ------

1401.48 ------ 1. 39 5.583E-01 ------ Line Not Found ------

1407.97 ------ 2.48 5.578E-01 ------ Line Not Found ------

1509.22 ------ 2.19 5.568E-01 ------ Line Not Found ------

1583.22 ------ 0. 72 5.628E-01 ------ Line Not Found ------

1661. 26 ------ 1.15 5.753E-01 ------ Line Not Found ------

1729.58 ------ 3.05 5.918E-01 ------ Line Not Found ------

1764.49 ------ 15.90 6.023E-01 ------ Line Not Found ------

1847.41 ------ 2.12 6.331E-01 ------ Line Not Found ------

PB-214 53.17 ------ 1.10 5.203E-01 ------ Line Not Found ------

74.81 ------ 6.52 l.570E+OO ------ Line Not Found ------

77 .11 24 11. 00 1. 669E+OO 1.004E-06 l.069E-06 51.15 87.19 ------ 3.88 l.983E+OO ------ Line Not Found ------

90 .13 ------ 1.15 2.055E+OO ------ Line Not Found ------

241. 92 ------ 7.46 2.043E+OO ------ Line Not Found ------

258.94 ------ 0.55 l.981E+OO ------ Line Not Found ------

295.09 35 19.20* 1.857E+OO 7.584E-07 8.074E-07 26.03 351.87 38 37.10 1.686E+OO 4.635E-07 4.934E-07 22.38 785.83 ------ 1. 09 8.674E-01 ------ Line Not Found ------

839.00 ------ 0.59 8.122E-01 ------ Line Not Found ------

Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30382 Acquisition date 6-JUN-2014 13:50:55 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error AC-228 89. 96 ------ 3.40 2.051E+OO ------ Line Not Found ------

93.35 ------ 5.60 2.124E+OO ------ Line Not Found ------

99.55 ------ 1. 30 2.229E+OO ------ Line Not Found ------

105.36 ------ 2.00 2.301E+OO ------ Line Not Found ------

108.99 ------ 0.67 2.335E+OO ------ Line Not Found ------

129.03 ------ 2.90 2.414E+OO ------ Line Not Found ------

153.89 ------ 0. 8 4 2.377E+OO ------ Line Not Found ------

209.39 25 4.10 2.168E+OO 2.138E-06 2.148E-06 33.24 216.24 ------ 0.80 2.141E+OO ------ Line Not Found ------

270.26 ------ 3.80 1. 941E+OO ------ Line Not Found ------

328.07 ------ 3.50 1.756E+OO ------ Line Not Found ------

338.42 23 12.40 l.726E+OO 8.393E-07 8.431E-07 29.94 340.94 ------ 0.52 1.718E+OO ------ Line Not Found ------

409.62 ------ 2.20 1. 531E+OO ------ Line Not Found ------

463.10 ------ 4.60 1.401E+OO ------ Line Not Found ------

562.65 ------ 1. 01 1.195E+OO ------ Line Not Found ------

581.52 ------ 3.00 1.160E+OO ------ Line Not Found ------

72 6. 63 ------ 0.87 9.382E-01 ------ Line Not Found ------

755.28 ------ 1. 32 9.027E-01 ------ Line Not Found ------

772.28 ------ 1. 09 8.827E-01 ------ Line Not Found ------

782.12 ------ 0.59 8.716E-01 ------ Line Not Found ------

794.79 ------ 4.60 8.576E-01 ------ Line Not Found ------

830.59 ------ 0.63 8.205E-01 ------ Line Not Found ------

835.60 ------ 1. 71 8.155E-01 ------ Line Not Found ------

810.11 ------ 0.94 8.108E-01 ------ Line Not Found ------

904.29 ------ 0.89 7.542E-01 ------ Line Not Found ------

911.16 ------ 29.00* 7.487E-01 ------ Line Not Found ------

964. 64 ------ 5.80 7.091E-01 ------ Line Not Found ------

968. 97 19 17.40 7.062E-01 1.169E-06 1.174E-06 21. 33 1246.60 ------ 0.57 5.825E-Ol ------ Line Not Found ------

1459.19 ------ 1. 06 5.560E-01 ------ Line Not Found ------

1496.00 ------ 1. 05 5.563E-01 ------ Line Not Found ------

1501. 44 ------ 0.58 5.565E-01 ------ Line Not Found ------

1580.30 ------ 0. 71 5.624E-01 ------ Line Not Found ------

1588.23 ------ 3.60 5.634E-01 ------ Line Not Found ------

1630.47 ------ 1. 95 5. 696E-01 ------ Line Not Found ------

1638.10 ------ 0.54 5.709E-01 ------ Line Not Found ------

Flag: "* II = Keyline

Minimum Detectable Activity Report Page : 7 Sample ID 30382 Acquisition date 6-JUN-2014 13:50:55 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)

BE-7 3. 477.61 6.1272E-07 MN-54 2. 834.83 9.2108E-08 MN-56 1. 846.81 7.1547E-08 C0-57 15. 122.06 7.6542E-08 C0-58 0. 810.79 2.4757E-08 C0-60 3. 1332.50 l.3737E-07 SB-124 3. 602.73 7.5023E-08 SB-125 2. 427.88 1.5973E-07 CS-134 2. 604.71 6.9217E-08 CS-137 3. 661.66 9.4633E-08