ML20034E211
Text
Sample ID:
142496 Type: RLSSS Type Detail: SAND
==
Description:==
140605BD06 SOUTH LAY DOWN# 14 Common Resp Org: P4000 - PROJECT MANAGEMEt
Contact:
COOPER, TERRY L Reference ID:
Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:
Origin I Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Unknown Mat:
NO Date: 06/06/14 09:52 Mat. SizeNolume:
1970 GRAMS Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00
==
Description:==
SOUTH LAY DOWN #14 Collection]
Sample Tech:
DYNES, WILLIAM J Tritium Req:
No Instructions:
COUNT TO MDA Comments:
COUNT TO MDA RLSSS Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
Yes l.bQcation I Unit: NON-UNIT RE Stored By:,
Sample Loe:
Area: MS Other: COUNT TO MDA Material Loe:
06/19/201410:16 Sample Date: 06/05/14 09:05 Sample SizeNolume: 1970 GRAMS Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
~
Elev: 100 Room:
Depth:
(in.)
Equip ID:
Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of 3
Health Physics Sample Records Sample ID:
142496 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140605BD06 SOUTH LAY DOWN# 14 Analysis Geometry MCAID Quant.
Units Method FP/AP Lab Analysis By B _ 1 L _ marinelli_ sand -
30393 1970GR
.000 NEESE, DAVID J Isotope Mode Activity Activity Uncert.
LLD/MDA
%Abund.
Atom. No.
Comments 0
K-40 NT 8.71E-6 1.266E-6 r
82.671%
40 0
TL-208 NT 3.702E-7 7.56E-8 r
3.514%
208 0
PB-212 NT 3.88E-7 1.234E-7 r
3.683%
212 0
81-214 NT 5.202E-7 1.115E-7 r
4.937%
214 0
PB-214 NT 5.474E-7 1.59E-7 r
5.196%
214 0
BE-7 AP 7.6477E-7 w
0.000%
7 0
54 0
MN-56 AP 1.4458E-7 IV 0.000%
56 0
C0-57 AP 8.6914E-8 IV 0.000%
57 0
C0-58 AP 7.9562E-8 w
0.000%
58 0
C0-60 AP 8.6724E-8 IV 0.000%
60 0
SB-124 AP 7.5097E-8 IV 0.000%
124 0
SB-125 FP 1.9975E-7 IV 0.000%
125 0
CS-134 FP 6.4392E-8 w
0.000%
134 0
0.000%
137 Analysis Review Re-Analize:
No Lie Rad Mat Present:
No Reviewed: COOPER, TERRY L HP Notified Name:
Hp Eng Rvw Reqd:
Yes Comments:
06/19/201410:16 Rad Mat Present:
Yes Rasterized: r Date Mod ID Mod Date 06/06/14 21:13 Mod Id Mod Date Date: 06/11/14 07:03 Page 2 of 3
Sample ID:
142496 Type: RLSSS Type Detail: SAND
==
Description:==
140605BD06 SOUTH LAY DOWN# 14 I Review/Approve I Reviewed: COOPER, TERRY L Comments:
Disposition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/19/2014 10:16 Health Physics Sample Records Status: APPROVED Rasterized: r HP Review Date: 06/11/14 07:04 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/11/14 07:04 Page 3 of 3
SONGS HEALTH PHYSICS REPORT 6-JUN-2014 21:07
- Title
>>>>> SAMPLE PARAMETERS<<<<<
140605BD06 SOUTH LAY DOWN# 14
- ID 30393 Acquisition date: 6-JUN-2014 21:04:29. *
- Start Time:
- Stop Time:
- Quantity
- Geometry 6-JUN-2014 21:04:00.
6-JUN-2014 21:04:00.
Counting System l.97000E+03 GR IHPS Sample Number:
B lL marinelli_sand_l Analysis Library Operator: DAVID NEEBE U2GSP 142496 HP NATURAL
>>>>> B #42-TP11663A PARAMETERS<<<<<
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.45 0 00:03:00.49 0.0%
1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 6-JUN-2014 20:09:
-4.40560E-01 5.00074E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1
238.76 40 34
- 1. 23 478.34 475 10 31. 8 1. 31E+OO PB-212 1
295.44 21 7
- 1. 48 591. 68 588 7 29.1 2.51E-01 PB-214 1
583.39 25 0
- 1. 81 1167.50 1162 10 20.4 5.0lE-01 TL-208 1
609.26 26 2
2.30 1219.23 1215 9 21. 4 5.54E-01 BI-214 1
1460.76 51 0
2.13 2922.04 2916 13 14.5 6.84E-01 K-40
Summary of Nuclide Activity Sample ID : 30393 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :
2 6-JUN-2014 21:04:29 Number of lines tentatively identified by NID 5
0 5
100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error Flags K-40 l.28E+09Y
- 1. 00 8.710E-06 8.710E-06 l.266E-06 14.54 A
TL-208 3.05M
- 1. 54 2.403E-07 3.702E-07 0.756E-07 20.41 A
PB-212 10.64H
- 1. 00 3.872E-07 3.BBOE-07 1.234E-07
- 31. 80 A
BI-214 19.90M
- 1. 07 4.856E-07 5.202E-07
- 1. 115E-07
- 21. 43 A
PB-214 26.80M
- 1. 05 5.201E-07 5.474E-07
- 1. 590E-07 29.05 A
Total Activity 1.034E-05 l.054E-05 Grand Total Activity :
1.034E-05 1.054E-05 Flags: "K" Keyline not found "M"
Manually accepted "E"
Manually edited "A"
Nuclide specific abn. limit
Unidentified Energy Lines Sample ID : 30393 None Flags: "T" Tentatively associated Page :
3 Acquisition date 6-JUN-2014 21:04:29
Interference Report Sample ID : 30393 No interference correction performed Acquisition date Page :
4 6-JUN-2014 21:04:29
Nuclide Line Activity Report Page :
5 Sample ID : 30393 Acquisition date 6-JUN-2014 21:04:29 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 51 10.67*
- 8. 710E-06 14.54 TL-208
- 72. 80 2.14
- 1. 070E+OO Line Not Found ------
74.97 3.60 1.156E+OO Line Not Found ------
84.79 ------
- 1. 27
- 1. 506E+OO Line Not Found ------
252.45 ------
0.80 l.745E+OO Line Not b,ound ------
277.28 6.80 1.645E+OO ------
Line Not Found ------
510.61 ------
- 21. 60 1.035E+OO Line Not Found ------
583.02 25 86.00*
9.194E-01 2.403E-07 3.702E-07 20.41 763.06 ------
- 1. 64 7.126E-Ol ------
Line Not Found ------
860.30 ------
12.00 6.341E-01 ------
Line Not Found ------
PB-212 74.81 ------
10.50 1.150E+OO Line Not Found ------
77.11 ------
17.70
- 1. 239E+OO Line Not Found ------
87.19 ------
6.27
- 1. 579E+OO Line Not Found ------
90.13
- 1. 86
- 1. 662E+OO Line Not Found ------
115. 12 0.59 2.085E+OO Line Not Found ------
238.58 40 43.60*
- 1. 804E+OO 3.872E-07 3.880E-07
- 31. 80 300.03 ------
3.34
- 1. 562E+OO Line Not Found ------
BI-214
- 76. 86 0.58 1.229E+OO Line Not Found ------
79.29 ------
0.97
- 1. 320E+OO ------
Line Not Found ------
609.31 26 46.10*
8.834E-01 4.856E-07 5.202E-07
- 21. 43 665.44
- 1. 56 8.131E-01 ------
Line Not Found ------
768.35 4.88 7.078E-01 ------
Line Not Found ------
806.16 ------
- 1. 23 6.754E-Ol ------
Line Not Found ------
934.04 ------
3.16 5.861E-01 ------
Line Not Found ------
1120. 27 15.00 4.982E-01 ------
Line Not Found ------
1155.18 ------
- 1. 69 4.860E-01 ------
Line Not Found ------
1238. 11 5.92 4.615E-01 ------
Line Not Found ------
1280.95 ------
- 1. 47 4.510E-Ol ------
Line Not Found ------
1377. 66 ------
4.02 4.323E-01 ------
Line Not Found ------
1385.30 ------
0.78
- 4. 311E-01 ------
Line Not Found ------
1401.48 ------
- 1. 39 4.287E-01 Line Not Found ------
1407.97 2.48 4.277E-01 ------
Line Not Found ------
1509.22 ------
2.19 4.165E-01 Line Not Found ------
1583.22 ------
0.72 4.120E-01 Line Not Found ------
1661. 26 1.15 4.103E-01 Line Not Found ------
1729.58 ------
3.05 4.114E-01 Line Not Found ------
1764.49 ------
15.90 4.128E-01 ------
Line Not Found ------
1847.41 ------
2.12 4.187E-01 ------
Line Not Found ------
PB-214 53.17 1.10 2.929E-01 ------
Line Not Found ------
74.81 ------
6.52 1.150E+OO Line Not Found ------
77.11
- 11. 00 1.239E+OO Line Not Found ------
87.19 ------
3.88 1.579E+OO Line Not Found ------
90.13 ------
1.15 1.662E+OO Line Not Found ------
241. 92 7.46 1.790E+OO Line Not Found ------
258.94 ------
0.55
- 1. 718E+OO Line Not Found ------
295.09 21 19.20*
1.578E+OO 5.201E-07 5.474E-07 29.05 351. 87 37.10 1.395E+OO Line Not Found ------
785.83
- 1. 09 6.925E-01 Line Not Found ------
839.00 ------
0.59 6.497E-01 Line Not Found ------
Nuclide Line Activity Report (continued)
Page :
6 Sample ID : 30393 Acquisition date 6-JUN-2014 21:04:29 Flag: "*"
Keyline
Minimum Detectable Activity Report Page :
7 Sample ID 30393 Acquisition date 6-JUN-2014 21:04:29 Bckgnd Energy MDA Nuclide Sum (keV)
(uCi/GR)
BE-7
- 4.
477.61 7.6477E-07 MN-54
- 1.
834.83 8.5646E-08 MN-56
- 4.
846.81
- 1. 4458E-07 C0-57
- 15.
122.06 8.6914E-08 C0-58
- 1.
810.79 7.9562E-08 C0-60
- 0.
1332.50
- 8. 6724E-08 SB-124
- 2.
602.73 7.5097E-08 SB-125
- 2.
427.88
- 1. 9975E-07 CS-134
- 1.
604. 71 6.4392E-08 CS-137
- 4.
661. 66
- 1. 2974E-07