ML20034D972

From kanterella
Jump to navigation Jump to search
Sy C-HATCH 8-20 - Health Physics Sample Records
ML20034D972
Person / Time
Site: San Onofre  
Issue date: 06/18/2014
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034D972 (10)


Text

Sample ID:

142437 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 08 STAR 8-20 Dirt Sample

[£q_mmonl Resp Org: P4000 - PROJECT MANAGEMEt

Contact:

COOPER, TERRY L Reference ID:

Comments:

Reviewed: DYNES, WILLIAM J Comments:

Origin I Mat. SizeNolume:

1000 ml

==

Description:==

STAR 02 SOIL SAMPLE I co11ection]

Sample Tech: DYNES, WILLIAM J Tritium Req:

No Instructions:

Comments:

COUNT TO MDA J~RTsss-J Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes Location Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 05/29/1411:24 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 05/28/1413:11 Sample SizeNolume: 2104 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

Ji1" Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth: 3" (in.)

Equip ID:

Date: 00/00/00 00:00 Other:

Material Loe:

06/18/201411:51 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Health Physics Sample Records Sample ID:

142437 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140528BD 08 STAR 8-20 Dirt Sample Analysis Geometry MCAID Quant.

Units Method FP/AP Lab Analysis By A_1L_marinelli_sand_

30270 2104GR

.000 ABERNATHY, AGNES B Isotope Mode Activity Activity Uncert.

LLD/MDA

%Abund.

Atom. No.

Comments 0

K-40 NT 0.00001147 1.2E-6 r

83.624%

40 0

PB-212 NT 6.502E-7 1.47E-7 r

4.740%

212 0

Bl-214 NT 3.284E-7 8.24E-8 r

2.394%

214 0

PB-214 NT 7.043E-7 2.136E-7 r

5.135%

214 0

AC-228 NT 5.633E-7 1.499E-7 r

4.107%

228 0

BE-7 AP 5.5993E-7

~

0.000%

7 0

MN-54 AP 1.0108E-7 fi7' 0.000%

54 0

MN-56 AP 7.6673E-8 w

0.000%

56 0

C0-57 AP 7.8074E-8 Iv" 0.000%

57 0

C0-58 AP 1.0738E-7

~

0.000%

58 0

C0-60 AP 9.5645E-8

~

0.000%

60 0

SB-124 AP 7.1542E-8 Iv 0.000%

124 0

SB-125 FP 1.7945E-7 Iv 0.000%

125 0

CS-134 FP 7.1416E-8 Iv 0.000%

134 0

CS-137 FP 2.25E-8 Iv 0.000%

137 I Analysis Review I Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L HP Notified Name:

Hp Eng Rvw Reqd:

Yes Comments:

06/18/201411:51 Rad Mat Present:

Yes Rasterized: r Date Mod ID Mod Date 05/29/1416:13 Mod Id Mod Date Date: 06/10/14 09:48 Page 2 of 3

Sample ID:

142437 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 08 STAR 8-20 Dirt Sample I Review/Approve I Reviewed: COOPER, TERRY L Comments:

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/18/2014 11 :51 Health Physics Sample Records Status: APPROVED Rasterized:

HP Eng Review Date: 06/10/14 09:48 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/10/14 09:48 Page 3 of 3

SONGS HEALTH PHYSICS REPORT 29-MAY-2014 16:07

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140528BD 08 STAR 8-20 DIRT SAMPLE

  • ID 30270 Acquisition date: 29-MAY-2014 16:04:02 *
  • Start Time: 29-MAY-2014 16:04:00
  • Stop Time: 29-MAY-2014 16:04:00 Counting System U2GSP
  • Quantity 2.10400E+03 GR IHPS Sample Number: 142437
  • Geometry A lL marinelli_sand_l Analysis Library HP NATURAL Operator: AGNES ABERNATHY

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.39 0 00:03:00.45 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 28-MAY-2014 21:10 2.58874E-01 4.99485E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

238.28 83 82

1. 39 476.54 473 11 22.6 1. 54E+Ol PB-212 1

295.34 34 20

1. 55 590.76 586 12 30.3 1. 03E+OO PB-214 1

338.10 17 9

1. 50 676.39 673 9 39.9 1.38E+OO AC-228 1

351.84 51 18

1. 93 703.90 700 10 21. 2 8.24E+OO PB-214 1

609.30 22 2

1. 64 1219.35 1215 9 25.1 8. 7lE-01 BI-214 1

911. 24 17 2

1. 67 1823.86 1819 8 26.6 2.23E-01 AC-228 1

1460.73 91 0

1. 92 2924.03 2919 10 10.4 7.20E-01 K-40

Summary of Nuclide Activity Sample ID: 30270 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :

2 29-MAY-2014 16:04:02 Number of lines tentatively identified by NID 7

0 7

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 1.28E+09Y

1. 00 1.147E-05 1.147E-05 0.120E-05 10.45 A

PB-212 10.64H

1. 00 6.492E-07 6.502E-07 1.470E-07 22.61 A

BI-214 19.90M

1. 05
3. 113E-07 3.284E-07 0.824E-07 25.10 A

PB-214 26.BOM

1. 04 6.768E-07 7.043E-07 2.136E-07 30.33 A

AC-228 6.13H

1. 00 5.617E-07 5.633E-07 l.499E-07
26. 61 A

Total Activity 1.367E-05

1. 371E-05 Grand Total Activity :

1.367E-05

1. 371E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30270 None Flags: "T" Tentatively associated Page :

3 Acquisition date 29-MAY-2014 16:04:02

Interference Report Sample ID : 30270 No interference correction performed Acquisition date Page :

4 29-MAY-2014 16:04:02

Nuclide Line Activity Report Page :

5 Sample ID : 30270 Acquisition date 29-MAY-2014 16:04:02 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 91 10.67*

5.314E-01 l.147E-05 1.147E-05 10.45 PB-212 74.81 ------

10.50 l.685E+OO Line Not Found ------

77.11 ------

17.70 1.782E+OO Line Not Found ------

87.19 ------

6.27 2.129E+OO Line Not Found ------

90.13 ------

1. 86 2.206E+OO Line Not Found ------

115. 12 ------

0.59 2.535E+OO Line Not Found ------

238.58 83 43.60*

2.084E+OO 6.492E-07 6.502E-07 22.61 300.03 3.34 l.834E+OO Line Not Found ------

BI-214 76.86 0.58 1.772E+OO ------

Line Not Found ------

79.29 ------

0.97 1.869E+OO ------

Line Not Found ------

609.31 22 46.10*

1.084E+OO 3.113E-07 3.284E-07 25.10 665.44

1. 56 9.985E-01 ------

Line Not Found ------

768.35 ------

4.88 8.685E-01 ------

Line Not Found ------

806.16 ------

1. 23 8.283E-01 ------

Line Not Found ------

934.04 ------

3.16 7.177E-01 ------

Line Not Found ------

1120.27 15.00 6.114E-01 ------

Line Not Found ------

1155. 18

1. 69 5.973E-01 ------

Line Not Found ------

1238.11 ------

5.92 5.697E-01 Line Not Found ------

1280.95 ------

1. 47 5.585E-01 ------

Line Not Found ------

1377. 66 4.02 5.401E-01 ------

Line Not Found ------

1385.30 ------

0.78 5.391E-01 ------

Line Not Found ------

1401.48 ------

1. 39 5.370E-01 Line Not Found ------

1407.97 2.48 5.362E-01 ------

Line Not Found ------

1509.22 ------

2.19 5.292E-01 Line Not Found ------

1583.22 ------

0.72 5.296E-01 ------

Line Not Found ------

1661. 26 1.15 5.351E-01 Line Not Found ------

1729.58 ------

3.05 5.442E-01 Line Not Found ------

1764.49 ------

15.90 5.503E-01 ------

Line Not Found ------

1847.41 ------

2.12 5.694E-01 Line Not Found ------

PB-214 53.17 1.10 5.543E-01 ------

Line Not Found ------

74.81 6.52 1.685E+OO Line Not Found ------

77.11 ------

11. 00 1.782E+OO Line Not Found ------

87.19 ------

3.88 2.129E+OO Line Not Found ------

90.13 ------

1.15 2.206E+OO Line Not Found ------

241. 92 ------

7.46 2.067E+OO Line Not Found ------

258.94 0.55 l.994E+OO Line Not Found ------

295.09 34 19.20*

1. 851E+OO 6.768E-07 7.043E-07 30.33 351. 87 51 37.10 l.662E+OO 5.925E-07 6.165E-07
21. 20 785.83
1. 09 8.495E-01 Line Not Found ------

839.00 0.59

7. 964E-01 Line Not Found ------

AC-228

89. 96 3.40 2.201E+OO Line Not Found ------

93.35 ------

5.60 2.279E+OO Line Not Found ------

99.55 ------

1. 30 2.389E+OO Line Not Found ------

105.36 ------

2.00 2.463E+OO Line Not Found ------

108.99 ------

0.67 2.496E+OO Line Not Found ------

129.03 2.90 2.562E+OO Line Not Found ------

153.89 0.84

2. 4 96E+OO Line Not Found ------

209.39 ------

4.10 2.221E+OO Line Not Found ------

216.24 0.80 2.187E+OO Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30270 Acquisition date 29-MAY-2014 16:04:02 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error 270.26 ------

3.80 1.948E+OO Line Not Found ------

328.07 3.50 1.738E+OO Line Not Found ------

338.42 17 12.40 1.705E+OO 5.741E-07 5.758E-07 39.90 340.94 0.52

1. 696E+OO Line Not Found ------

409.62 2.20 l.499E+OO ------

Line Not Found ------

463.10 ------

4. 60 1.368E+OO Line Not Found ------

562.65 ------

1. 01 1.164E+OO Line Not Found ------

581.52 3.00 1.131E+OO Line Not Found ------

72 6. 63 0.87 9.173E-01 ------

Line Not Found ------

755.28

1. 32 8.833E-01 ------

Line Not Found ------

772. 28

1. 09 8.641E-01 ------

Line Not Found ------

782.12 0.59 8.534E-01 ------

Line Not Found ------

794.79

4. 60 8.400E-01 ------

Line Not Found ------

830.59 ------

0.63 8.043E-Ol ------

Line Not Found ------

835.60 ------

1. 71
7. 996E-01 ------

Line Not Found ------

840.44 ------

0.94 7.951E-01 ------

Line Not Found ------

904.29 ------

0.89 7.403E-01 ------

Line Not Found ------

911.16 17 29.00*

7.348E-01 5.617E-07 5.633E-07 26.61 964. 64 5.80 6.962E-01 ------

Line Not Found ------

968.97 17.40 6.933E-01 ------

Line Not Found ------

1246.60 ------

0.57 5.673E-01 ------

Line Not Found ------

1459.19 ------

1. 06 5.315E-01 ------

Line Not Found ------

1496.00 ------

1. 05 5.296E-Ol ------

Line Not Found ------

1501.44 0.58 5.294E-01 ------

Line Not Found ------

1580.30 ------

0. 71 5.295E-01 ------

Line Not Found ------

1588.23 ------

3.60 5.298E-01 ------

Line Not Found ------

1630.47

1. 95 5.324E-01 ------

Line Not Found ------

1638.10 ------

0.54 5.330E-01 ------

Line Not Found ------

Flag: "*" = Keyline

Minimum Detectable Activity Report Sample ID 30270 Nuclide BE-7 MN-54 MN-56 C0-57 C0-58 C0-60 SB-124 SB-125 CS-134 CS-137 Bckgnd Sum

3.
3.
1.
21.
4.
1.
3.
3.
3.
0.

Energy (keV) 477.61 834.83 846.81 122.06 810.79 1332. 50 602.73 427.88 604. 71 661. 66 Acquisition date MDA (uCi/GR) 5.5993E-07

1. 0108E-07 7.6673E-08 7.8074E-08
1. 0738E-07 9.5645E-08 7.1542E-08 1.7945E-07 7.1416E-08 2.2500E-08 Page :

7 29-MAY-2014 16:04:02