Sample ID:

142434 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 05 STAR 5-20 Dirt Sample ICommonl Resp Org: P4000 - PROJECT MANAGEMEr

Contact:

COOPER, TERRY L Reference ID:

Comments:

Reviewed: DYNES, WILLIAM J Comments:

1 *oriiifn -I Mat. SizeNolume:

1000 ml

==

Description:==

STAR 05 SOIL SAMPLE I Collection I Sample Tech: DYNES, WILLIAM J Tritium Req:

No Instructions:

Comments:

COUNT TO MDA RLSSS Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes

!Iocaiioi:!J Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 05/29/1411:18 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 05/28/1412:56 Sample SizeNolume: 1927 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

J\\7' Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth: 3" (in.)

Equip ID:

Date: 00/00/00 00:00 Other:

Material Loe:

06/18/2014 11 :50 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Sample ID:

142434 Type: RLSSS Type Detail: SAND Health Physics Sample Records Status: APPROVED

==

Description:==

140528BD 05 STAR 5-20 Dirt Sample Analysis Geometry MCAID Quant.

Units Method FP/AP A_ 1 L_marinelli_sand_

30271 1927GR

.000 Isotope Mode Activity Activity Uncert.

LLD/MDA

%Abund.

0 K-40 NT 9.268E-6 0

TL-208 NT 1.932E-7 0

PB-212 NT 3.617E-7 0

Bl-214 NT 3.224E-7 0

PB-214 NT 3.444E-7 0

AC-228 NT 5.046E-7 0

BE-7 AP 7.1888E-7 0

MN-54 AP 9.0128E-8 0

MN-56 AP 1.2039E-7 0

C0-57 AP 8.1742E-8 0

C0-58 AP 6.9726E-8 0

C0-60 AP 7.4753E-8 0

SB-124 AP 7.3167E-8 0

SB-125 FP 1.3753E-7 0

CS-134 FP 6.769E-8 0

CS-137 FP 1.2057E-7 Analysis Review Re-Analize:

No Hp Eng Rvw Reqd:

Yes Comments:

06/18/2014 11 :50 1.138E-6 r

84.298%

6.36E-8 r

1.757%

9.39E-8 r

3.290%

7.17E-8 r

2.932%

1.12E-7 r

3.133%

1.508E-7 r

4.590%

Iv 0.000%

W' 0.000%

Iv 0.000%

Iv 0.000%

Iv 0.000%

IV 0.000%

Iv 0.000%

!v 0.000%

Iv 0.000%

rv 0.000%

Lie Rad Mat Present:

No Rad Mat Present:

Yes Atom. No.

40 208 212 214 214 228 7

54 56 57 58 60 124 125 134 137 Lab Analysis By ABERNATHY, AGNES B Comments Reviewed: COOPER, TERRY L HP Notified Name:

Rasterized: r Date Mod ID Mod Date 05/29/1416:18 Mod Id Mod Date Date: 06/10/14 09:36 Page 2 of 3

Sample ID:

142434 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 05 STAR 5-20 Dirt Sample

[Review1.Approve I Reviewed: COOPER, TERRY L Comments:

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/18/2014 11 :50 Health Physics Sample Records Status: APPROVED Rasterized: r HP Eng Review Date: 06/10/14 09:36 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/10/14 09:36 Page 3 of 3

SONGS HEALTH PHYSICS REPORT 29-MAY-2014 16:13

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140528BD 05 STAR 5-20 DIRT SAMPLE

  • ID 30271 Acquisition date: 29-MAY-2014 16:10:08 *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 29-MAY-2014 16:10:00 29-MAY-2014 16:10:00 Counting System 1.92700E+03 GR IHPS Sample Number:

A 11 marinelli_sand_l Analysis Library Operator: AGNES ABERNATHY U2GSP 142434 HP NATURAL

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.47 0 00:03:00.53 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 28-MAY-2014 21:10 2.58874E-01 4.99485E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

77.26 25 20

1. 25 154.16 152 6 35.3 5.46E+OO BI-214 PB-212 PB-214 1

238.79 42 23

1. 54 477.55 474 9 25.9 6.66E+OO PB-212 1

295.19 15 3

1. 39 590.48 587 7 32.5 1.93E+OO PB-214 1

351. 72 33 0

1. 84 703.66 698 10 18.9 2.12E+OO PB-214 1

583.52 17 5

1. 59 1167.73 1162 9 32.9 8.44E-01 TL-208 1

609.38 20 0

2.46 1219.50 1215 8 22.3 1. OOE+OO BI-214 1

911. 01 14 2

1. 68 1823.40 1819 8 29.9 9.47E-02 AC-228 1

1460.91 68 0

2.04 2924.38 2918 12 12.3 5.08E-01 K-40

Summary of Nuclide Activity Sample ID : 30271 Total number of lines in spectrum Number of unidentified lines Page :

2 Acquisition date 29-MAY-2014 16:10:08 Number of lines tentatively identified by NID 8

0 0

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 1.28E+09Y

1. 00 9.268E-06 9.268E-06 l.138E-06 12.28 A

TL-208 3.05M

1. 42 1.358E-07 l.932E-07 0.636E-07 32.94 A

PB-212 10.64H

1. 00
3. 611E-07 3.617E-07 0.939E-07 25.95 A

BI-214 19.90M

1. 06 3.047E-07 3.224E-07 0.717E-07 22.25 A

PB-214

26. SOM
1. 04 3.302E-07 3.444E-07 1.120E-07 32.51 A

AC-228 6.13H

1. 00 5.031E-07 5.046E-07 l.508E-07 29.88 A

Total Activity 1.090E-05 l.099E-05 Grand Total Activity :

1.090E-05

1. 099E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30271 None Flags: "T" Tentatively associated Page :

3 Acquisition date 29-MAY-2014 16:10:08

Interference Report Sample ID : 30271 No interference correction performed Acquisition date Page :

4 29-MAY-2014 16:10:08

Nuclide Line Activity Report Page :

5 Sample ID : 30271 Acquisition date 29-MAY-2014 16:10:08 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 68 10.67*

5.314E-01 9.268E-06 9.268E-06 12.28 TL-208 72.80 ------

2.14 1.594E+OO ------

Line Not Found ------

74.97 3.60 1.692E+OO ------

Line Not Found ------

84.79 ------

1. 27 2.058E+OO Line Not Found ------

252.45 ------

0.80

2. 021E+OO Line Not Found ------

277.28 6.80 l.920E+OO Line Not Found ------

510.61 ------

21. 60 1.265E+OO Line Not Found ------

583.02 17 86.00*

1.127E+OO l.358E-07 1.932E-07 32.94 763.06 ------

1. 64 8.744E-01 ------

Line Not Found ------

860.30 12.00 7.770E-01 ------

Line Not Found ------

PB-212 74.81 ------

10.50

1. 685E+OO Line Not Found ------

77.11 25 17.70 1.789E+OO 6.243E-07 6.254E-07 35.34 87.19 ------

6.27 2.129E+OO ------

Line Not Found ------

90.13 ------

1. 86 2.206E+OO Line Not Found ------

115.12 ------

0.59 2.535E+OO Line Not Found ------

238.58 42 43.60*

2.081E+OO

3. 611E-07 3.617E-07 25.95 300.03 ------

3.34 l.834E+OO Line Not Found ------

BI-214

76. 86 25 0.58 1.789E+OO l.905E-05 2.016E-05 35.34 79.29 ------

0.97 1.869E+OO Line Not Found ------

609.31 20 46.10*

l.084E+OO 3.047E-07 3.224E-07 22.25 665.44

1. 56 9.985E-01 ------

Line Not Found ------

768.35 ------

4.88 8.685E-01 ------

Line Not Found ------

806.16 ------

1. 23 8.283E-01 ------

Line Not Found ------

934.04 3.16 7.177E-01 ------

Line Not Found ------

1120. 27 15.00 6.114E-01 ------

Line Not Found ------

1155.18 ------

1. 69 5.973E-01 ------

Line Not Found ------

1238. 11 ------

5.92 5.697E-01 ------

Line Not Found ------

1280.95 ------

1. 47 5.585E-01 ------

Line Not Found ------

1377. 66 4.02 5.401E-Ol ------

Line Not Found ------

1385.30 ------

0.78 5.391E-01 ------

Line Not Found ------

1401.48 ------

1. 39 5.370E-01 ------

Line Not Found ------

1407.97 ------

2.48 5.362E-01 ------

Line Not Found ------

1509.22 ------

2.19 5.292E-01 ------

Line Not Found ------

1583.22 ------

0.72

5. 296E-01 ------

Line Not Found ------

1661. 26 ------

1.15 5.351E-01 ------

Line Not Found ------

1729.58 ------

3.05 5.442E-01 Line Not Found ------

1764.49 ------

15.90 5.503E-01 ------

Line Not Found ------

1847.41 ------

2.12 5.694E-01 Line Not Found ------

PB-214 53.17 ------

1.10 5.543E-01 ------

Line Not Found 74.81 ------

6.52 1.685E+OO ------

Line Not Found ------

77.11 25

11. 00 1.789E+OO
1. 004E-06 1.048E-06 35.34 87.19 ------

3.88 2.129E+OO Line Not Found ------

90.13 1.15 2.206E+OO Line Not Found ------

241. 92 ------

7.46 2.067E+OO Line Not Found ------

258.94 0.55 1.994E+OO ------

Line Not Found ------

295.09 15 19.20*

l.852E+OO 3.302E-07 3.444E-07 32.51 351.87 33 37.10 1.663E+OO

4. llOE-07 4.287E-07 18.90 785.83 ------
1. 09 8.495E-Ol ------

Line Not Found ------

839.00 ------

0.59 7.964E-01 ------

Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30271 Acquisition date 29-MAY-2014 16:10:08 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error AC-228

89. 96 3.40 2.201E+OO Line Not Found ------

93.35 ------

5.60 2.279E+OO Line Not Found ------

99.55 ------

1. 30 2.389E+OO Line Not Found ------

105.36 ------

2.00 2.463E+OO Line Not Found ------

108.99 ------

0.67

2. 496E+OO Line Not Found ------

129.03 ------

2.90 2.562E+OO Line Not Found ------

153.89 ------

0.84

2. 496E+OO Line Not Found ------

209.39 ------

4.10 2.221E+OO Line Not Found ------

216.24 ------

0.80 2.187E+OO Line Not Found ------

270.26 ------

3.80 1.948E+OO Line Not Found ------

328.07 ------

3.50

1. 738E+OO Line Not Found ------

338.42 ------

12.40 1.704E+OO Line Not Found ------

340.94 ------

0.52 1.696E+OO Line Not Found ------

409.62 ------

2.20 l.499E+OO ------

Line Not Found ------

463.10 ------

4.60 1.368E+OO Line Not Found ------

562.65 ------

1. 01 1.164E+OO Line Not Found ------

581.52 ------

3.00 1.131E+OO Line Not Found ------

726.63 0.87 9.173E-01 ------

Line Not Found ------

755.28

1. 32 8.833E-01 ------

Line Not Found ------

772. 28

1. 09 8.641E-01 Line Not Found ------

782.12 0.59 8.534E-01 ------

Line Not Found ------

794.79 ------

4.60 8.400E-Ol Line Not Found ------

830.59 ------

0.63 8.043E-01 ------

Line Not Found ------

835.60 ------

1. 71 7.996E-01 Line Not Found ------

840.44 0.94 7.951E-01 Line Not Found 904.29 ------

0.89 7.403E-01 Line Not Found ------

911.16 14 29.00*

7.350E-01 5.031E-07 5.046E-07 29.88 964. 64 ------

5.80

6. 962E-01 Line Not Found ------

968. 97 17.40 6.933E-01 ------

Line Not Found ------

1246.60 ------

0.57 5.673E-01 Line Not Found ------

1459.19 ------

1. 06 5.315E-01 Line Not Found ------

1496.00 ------

1. 05
5. 296E-01 Line Not Found ------

1501. 44 0.58 5.294E-01 Line Not Found ------

1580.30 ------

0.71 5.295E-01 Line Not Found ------

1588.23 ------

3.60 5.298E-01 Line Not Found ------

1630.47 ------

1. 95 5.324E-01 Line Not Found ------

1638.10 ------

0.54 5.330E-01 ------

Line Not Found ------

Flag: "*" = Keyline

Minimum Detectable Activity Report Page :

7 Sample ID 30271 Acquisition date 29-MAY-2014 16:10:08 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

5.

477.61 7.1888E-07 MN-54

2.

834.83 9.0128E-08 MN-56

4.

846.81 1.2039E-07 C0-57

19.

122.06 8.1742E-08 C0-58

1.

810.79

6. 972 6E-08 C0-60
0.

1173.24 7.4753E-08 SB-124

3.

602.73 7.3167E-08 SB-125

1.

427.88

1. 3753E-07 CS-134
2.

604. 71 6.7690E-08 CS-137

5.

661. 66

1. 2057E-07