E5Yso"N SONGS RADIOLOGICAL SURVEY El f5Yso"N DATE 06 /06 /2014 1 TIME 0715 Page 1 of 2
\\o~W><M"l'-'Mll>."I.._-,
UNIT N
SURVEY REASON D Post-Decon D Pre-Job SURVEY NO.
!'IV/.fCJC/ --!Jc> I I
SMEARS MASSLINNS YD D Routine D Shipment/Receipt MONO.
~
AREA Gross Hot ELEV NIA D Job Coverage D Source/Leak Test REP NO.
-~
~..- ~o.
13-y a
NO.
13-y a
NO.
Part.
dpm,v,..,
ROOM NIA D Pwr Entry Ix] Otherrnnfirm~*
~
' 1"'
16 A
0 Denotes sample loca,.
2 ""
17 B
3 18 C
MESA-LA YDOWN AREA (North) 4 19 D
N=33.37709 5
20 E
N=33.37749 W=ll 7.55718
~
W=l17.5579~
W I I 111 l I ~11111 J 111, IJl I J ' -
'../
6 F
7 22 ~
X 8
23
- 0) 0 3
9 24 I
10 25 11 0
12 4
6 13 14 X
15 G
8 0
SURVEY CLASS D Trend Pt.
D Component D Boundary
[xJ General Area D Individual SURVEY DESCRIPTION: Mesa Confirmatory Surveys LAYDOWN 10 12 REMARKS: Gamma scan survey in a seroentine pattern between survev ooints in numerical order was oerformed with
~
static readings taken at survey points 1-20. No activity above 14 background was detected.
BKG.=8000cnm No Storm Drains Present 17 Instruments used 16 18 iAsP1-sPA3 I -.
I
... T /.
I
... T /.
Model Serial No 1876 l I l"' J-\\.
I
.1.,, r-i..
I J.. '1 / £1..
N~3337649 / ~ @
TECHNICIAN SURVEY TYPE W=11755860
"'-.. *,...__ 19~ N=33.37605 Print M.Crumes/J.PapS9f.!i D Shutdown (S/D)
"'-..._....___ ~
20 f W 117.55815
/1&1}-
,- --Y~~-
Sign Reference Number
"-:.r
~x U'APPROV~ BY S0123-Vll-20.9 N=Northing GPS reading Print ~ -
Form Number W=Westing GPS reading Sign /7 /)
SCE HP (2/3) 1259-1000 GPS= Global Positioning System Approva11cfate: t;-"~Jfime:/
Vt:>
REV. 3 09/07
!:.I rtoYsoN SONGS RADIOLOGICAL SURVEY tJ EDi's 00N DATE 06 / 06 /2014 1 TIME 0715 Page 2 of 2
.....,.,..,...,,.""'""~--,
.. _,.,,,a,,.,., **._u,...,ic--
UNIT N
SURVEY REASON D Post-Decon D Pre-Job SURVEY NO. ff(/{p[/{pr-00/
I SMEARS MASSLINNS YD D Routine D Shipment/Receipt MONO.
M I A
-@ --.', NO.
13-y AREA Gross Hot ELEV NIA D Job Coverage D Source/Leak Test REP NO.
a NO.
13-y a
NO.
Part.
dpm IV/SI\\
ROOM NIA D Pwr Entry
~ Other rnnfinnatorv Survevs EQUIP. ID.
_1~
16 A
2 "'
17 B
3 18 C
4 19 D
5 20 E
Units 2/3 Laydown (North) 6
~
F 7
22 ~
/ a Survey Pt.
Sample ld.(IHPS)
GPS Static Reading(spa-3) 8 23 ""
I 1
142501 Lat.33.37727 Long-117.55793 8000 cpm 9
24
""-I 2
142502 Lat.33.37715 Long-117.55771 8000 cpm 10 25 3
N/A Lat.33.37705 Long-117.55753 8000 cpm 11 4
N/A Lat.33.37711 Long-117.55808 8000 cpm 12 I"'
~
5 142503 Lat.33.37697 Long-117.55784 8000 cpm 13 6
N/A Lat.33.37687 Long-117.55766 8000 cpm 14
~
7 142504 Lat.33.37698 Long-117.55821 8000 cpm 15 D Trend Pt.
D Component 8
N/A Lat.33.37682 Long-117.55800 8000 cpm SURVEY CLASS D Boundary
[lg General Area D Individual 9
142505 Lat.33.37668 Long-117.55780 8000 cpm SURVEY DESCRIPTION: Mesa Confirmatory Surveys N/A 10 Lat.33.37680 Long-117.55833 8000 cpm 11 142506 Lat.33.37665 Long-117.55810 8000 cpm REMARKS: GPS coordinates for all survev ooints.
12 N/A Lat.33.37652 Long-117.55790 8000 cpm GPS= Global Positioning System 13 142507 Lat.33.37667 Long-117.55844 8000 cpm 14 N/A Lat.33.37647 Long-117.55819 8000 cpm 15 142508 Lat.33.37635 Long-117.55799 8000 cpm 16 N/A Lat.33.37654 Long-117.55856 8000 cpm 17 N/A Lat.33.37637 Long-117.55834 8000 cpm Instruments used 18 N/A Lat.33.37622 Long-117.55811 8000 cpm Model
-..TIA I
-..r!A I
-..r / A I
-..Tt A I
....,.. :a..
I I.....
I I
n,n.
19 142509 Lat.33.37629 Long-117.55845 8000 cpm Serial No 20 142510 Lat.33.37605 Long-117.55817 8000 cpm TECHNICIAN SURVEY TYPE Print M.CrumeslJ.Pap~on; D Shutdown (S/D)
Sign lflM,J/ ~.l~A. Reference Number Ii_
I APPROV D BY S0123-Vll-20.9 Print a.~--
Form Number Sign 77).
SCE HP (2/3) 1259-1 000 Approval1 rfateJ;--;/1Jc(6/rime:/.$"'c).
I)
REV. 3 09/07