Sy C-HATCH 1-20 - Health Physics Sample Records
ML20034D965
Person / Time
Site: San Onofre  
Issue date: 06/18/2014
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034D965 (10)


Text

Health Physics Sample Records Sample ID:

142429 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140528BD01 Star 01-20 Common Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID:

Contact:

COOPER, TERRY L Reference ID:

Comments:

Reviewed: DYNES, WILLIAM J Comments:

Origin I Mat. SizeNolume:

1000 ml

==

Description:==

STAR 01 SAMPLE Collection Sample Tech:

DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA RLSSS Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes I LocatioriJ Unit: NON-UNIT RE Stored By:,

Sample Loe:

Other:

Material Loe:

06/18/201411:48 Area: MS Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 05/29/1411 :10 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 05/28/1411:33 Sample SizeNolume: 1993 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

~

Elev: 100 Room: N/A Depth: 3" (in.)

Equip ID:

Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of3

Health Physics Sample Records Sample ID:

142429 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

==

Description:==

140528BD01 Star 01-20 IAnalysisl Geometry MCAID Quant.

Units Method FP/AP Lab Analysis By Date Mod ID Mod Date A_ 1 L_marinelli_sand -

30266 1993GR

.000 ABERNATHY, AGNES B 05/29/14 14:58 lsotop~ Mode Activity Activity Uncert.

LLD/MDA

%Abund.

Atom. No.

Comments Mod Id Mod Date 0

K-40 NT 9.81E-6 1.226E-6 r

80.847%

40 0

TL-208 NT 2.646E-7 6.24E-8 r

2.181%

208 0

PB-212 NT 5.317E-7 1.044E-7 r

4.382%

212 0

Bl-214 NT 4.862E-7 1.16E-7 r

4.007%

214 0

PB-214 NT 5.196E-7 1.564E-7 r

4.282%

214 0

AC-228 NT 5.22E-7 1.46E-7 r

4.302%

228 0

BE-7 AP 2.9967E-7 Iv" 0.000%

7 0

MN-54 AP 9.3967E-8

~

0.000%

54 0

MN-56 AP 1.0712E-7 Iv" 0.000%

56 0

C0-57 AP 6.886E-8

~

0.000%

57 0

C0-58 AP 6.7443E-8 Iv' 0.000%

58 0

C0-60 AP 1.2741E-7

~

0.000%

60 0

SB-124 AP 6.9893E-8 w-0.000%

124 0

SB-125 FP 1.8578E-7

~

0.000%

125 0

CS-134 FP 1.1156E-7

~

0.000%

134 0

CS-137 FP 1.2816E-7 fi7" 0.000%

137 I Analysis Review Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L Date: 06/10/14 08:31 Hp Eng Rvw Reqd:

Yes Rad Mat Present:

Yes HP Notified Name:

Comments:

06/18/201411:48 Page 2 of 3

Sample ID:

142429 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD01 Star 01-20 I Review/Approve I Reviewed: COOPER, TERRY L Comments:

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/18/201411:48 Health Physics Sample Records Status: APPROVED Rasterized:

HP Review Date: 06/10/14 08:31 Dis1>0sition Result: Sample contains only natural isotopes Final Ae_proval Date: 06/10/14 08:32 Page 3 of 3

SONGS HEALTH PHYSICS REPORT 29-MAY-2014 14:50

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140528BD01 STAR 01-20

  • ID 30266 Acquisition date: 29-MAY-2014 14:47:30 *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 29-MAY-2014 14:47:00 29-MAY-2014 14:47:00 Counting System 1.99300E+03 GR IHPS Sample Number:

A lL marinelli sand 1 Analysis Library Operator: AGNES ABERNATHY U2GSP 142429 HP NATURAL

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.40 0 00:03:00.46 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 28-MAY-2014 21:10 2.58874E-01 4.99485E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1

238.68 64 34 1.12 477.33 474 7 19.6 3.59E+OO PB-212 1

295.33 23 7

1. 59 590.75 588 7 30.1 1. 35E+OO PB-214 1

338.13 20 8

1. 78 676.44 672 8 31.1 1. 53E-Ol AC-228 1

352.10 29 16

1. 37 704.41 700 9 30.9 4.96E-01 PB-214 1

583.19 22 2

2.24 1167. 07 1162 9 23.6 5.50E-01 TL-208 1

609.35 30 8

1. 74 1219.45 1214 10 23.9 3.67E-01 BI-214 1

911.11 15 0

1. 62 1823.61 1819 9 28.0 7.09E-01 AC-228 1

1460.98 74 3

1. 76 2924.53 2919 11 12.5 3.41E-01 K-40

Summary of Nuclide Activity Sample ID : 30266 Total number of lines in spectrum Number of unidentified lines Page :

2 Acquisition date 29-MAY-2014 14:47:30 Number of lines tentatively identified by NID 8

0 8

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 1.28E+09Y

1. 00 9.BlOE-06 9.BlOE-06 1.226E-06 12.50 A

TL-208 3.05M

1. 55
1. 710E-07 2.646E-07 0.624E-07 23.58 A

PB-212 10.64H

1. 00 5.305E-07 5.317E-07 1.044E-07 19.63 A

BI-214 19.90M

1. 07 4.535E-07 4.862E-07 1.160E-07 23.86 A

PB-214 26.80M

1. 05 4.934E-07 5.196E-07 1.564E-07 30.10 A

AC-228 6.13H

1. 00 5.200E-07 5.220E-07
1. 4 60E-07
27. 96 A

Total Activity 1.198E-05

1. 213E-05 Grand Total Activity :

1.198E-05 1.213E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30266 None Flags: "T" Tentatively associated Acquisition date Page :

3 29-MAY-2014 14:47:30

Interference Report Sample ID : 30266 No interference correction performed Acquisition date Page :

4 29-MAY-2014 14:47:30

Nuclide Line Activity Report Page :

5 Sample ID : 30266 Acquisition date 29-MAY-2014 14:47:30 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 74 10.67*

5.314E-01 9.810E-06 9.810E-06 12.50 TL-208

72. 80 2.14 1.594E+OO ------

Line Not Found ------

74.97 3.60 l.692E+OO Line Not Found ------

84.79 ------

1. 27 2.058E+OO Line Not Found ------

252.45 0.80 2.021E+OO Line Not Found ------

277.28 6.80

1. 920E+OO Line Not Found 510.61
21. 60 l.265E+OO ------

Line Not Found ------

583.02 22 86.00*

l.128E+OO

1. 710E-07
2. 64 6E-07 23.58 763.06 ------
1. 64 8.744E-01 Line Not Found ------

860.30 ------

12.00 7.770E-01 ------

Line Not Found ------

PB-212 74.81 10.50

1. 685E+OO Line Not Found ------

77.11 17.70

1. 782E+OO Line Not Found ------

87.19 ------

6.27 2.129E+OO ------

Line Not Found ------

90.13 ------

1. 86 2.206E+OO Line Not Found ------

115. 12 ------

0.59 2.535E+OO Line Not Found ------

238.58 64 43.60*

2.082E+OO 5.305E-07 5.317E-07 19.63 300.03 ------

3.34 l.834E+OO ------

Line Not Found ------

BI-214 76.86 ------

0.58 1.772E+OO Line Not Found ------

79.29 ------

0.97

1. 869E+OO Line Not Found ------

609.31 30 46.10*

1.084E+OO 4.535E-07 4.862E-07 23.86 665.44

1. 56 9.985E-01 Line Not Found ------

768.35 4.88 8.685E-01 ------

Line Not Found ------

806.16

1. 23 8.283E-01 Line Not Found ------

934.04 3.16 7.177E-01 Line Not Found ------

1120. 27 15.00 6.114E-01 Line Not Found ------

1155.18 ------

1. 69 5.973E-01 Line Not Found ------

1238. 11 5.92 5.697E-01 ------

Line Not Found ------

1280.95 ------

1. 4 7 5.585E-01 ------

Line Not Found ------

1377.66 ------

4.02 5.401E-Ol ------

Line Not Found ------

1385.30 ------

0.78 5.391E-Ol ------

Line Not Found ------

1401. 48

1. 39 5.370E-01 ------

Line Not Found ------

1407. 97 2.48 5.362E-01 ------

Line Not Found ------

1509.22 ------

2.19 5.292E-01 ------

Line Not Found ------

1583.22 ------

0.72 5.296E-Ol ------

Line Not Found ------

1661. 26 ------

1.15 5.351E-01 Line Not Found ------

1729.58 ------

3.05 5.442E-01 ------

Line Not Found ------

1764.49 ------

15.90 5.503E-01 Line Not Found ------

1847.41 ------

2.12 5.694E-Ol Line Not Found ------

PB-214 53.17 ------

1.10 5.543E-01 Line Not Found ------

74.81 ------

6.52 l.685E+OO Line Not Found ------

77.11 ------

11. 00
1. 782E+OO Line Not Found ------

87.19 ------

3.88 2.129E+OO Line Not Found ------

90.13 ------

1.15 2.206E+OO Line Not Found ------

241. 92 7.46 2.067E+OO ------

Line Not Found ------

258.94 0.55

1. 994E+OO Line Not Found ------

295.09 23 19.20*

1. 851E+OO 4.934E-07 5.196E-07 30.10 351. 87 29 37.10 l.661E+OO 3.580E-07 3.770E-07 30.94 785.83
1. 09 8.495E-01 ------

Line Not Found ------

839.00 0.59

7. 964E-01 Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30266 Acquisition date 29-MAY-2014 14:47:30 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error AC-228

89. 96 ------

3.40 2.201E+OO ------

Line Not Found ------

93.35 ------

5.60 2.279E+OO ------

Line Not Found ------

99.55 ------

1. 30 2.389E+OO ------

Line Not Found ------

105.36 ------

2.00 2.463E+OO ------

Line Not Found ------

108.99 ------

0.67 2.496E+OO Line Not Found ------

129.03 ------

2.90 2.562E+OO Line Not Found ------

153.89 ------

0.84 2.496E+OO Line Not Found ------

209.39 ------

4.10 2.221E+OO ------

Line Not Found ------

216.24 0.80 2.187E+OO Line Not Found ------

270.26 ------

3.80 1.948E+OO Line Not Found ------

328.07 ------

3.50 1.738E+OO Line Not Found ------

338.42 20 12.40 1.705E+OO 7.224E-07 7.252E-07 31.13 340.94 ------

0.52 l.696E+OO ------

Line Not Found ------

409.62 2.20 1.499E+OO ------

Line Not Found ------

463.10 ------

4.60 1.368E+OO ------

Line Not Found ------

562.65 ------

1. 01 1.164E+OO Line Not Found ------

581.52 ------

3.00 1.131E+OO ------

Line Not Found ------

726.63 ------

0.87 9.173E-01 ------

Line Not Found ------

755.28 ------

1. 32 8.833E-01 ------

Line Not Found ------

772. 28 ------

1. 09 8.641E-01 ------

Line Not Found ------

782.12 0.59 8.534E-01 ------

Line Not Found ------

794.79 ------

4.60 8.400E-01 ------

Line Not Found ------

830.59 ------

0.63 8.043E-01 ------

Line Not Found ------

835.60

1. 71 7.996E-01 ------

Line Not Found ------

840.44 ------

0.94 7.951E-01 ------

Line Not Found ------

904.29 ------

0.89 7.403E-01 ------

Line Not Found ------

911.16 15 29.00*

7.349E-01 5.200E-07 5.220E-07

27. 96 964.64 5.80 6.962E-01 ------

Line Not Found ------

968. 97 17.40 6.933E-01 ------

Line Not Found ------

1246.60 ------

0.57 5.673E-01 ------

Line Not Found ------

1459.19 ------

1. 06 5.315E-01 ------

Line Not Found ------

1496.00 ------

1. 05 5.296E-01 ------

Line Not Found ------

1501. 44 0.58 5.294E-01 ------

Line Not Found ------

1580.30 ------

0.71 5.295E-01 ------

Line Not Found ------

1588.23 ------

3.60 5.298E-Ol ------

Line Not Found ------

1630.47

1. 95 5.324E-01 ------

Line Not Found ------

1638.10 ------

0.54 5.330E-01 ------

Line Not Found ------

Flag: "*" = Keyline

Minimum Detectable Activity Report Sample ID 30266 Nuclide BE-7 MN-54 MN-56 C0-57 C0-58 C0-60 SB-124 SB-125 CS-134 CS-137 Bckgnd Sum

o.
2.
3.
14.
1.
2.
2.
3.
8.
7.

Energy (keV) 477.61 834.83 846.81 122.06 810.79 1332.50 602.73 427.88 604. 71 661.66 Acquisition date MDA (uCi/GR)

2. 9967E-07
9. 3967E-08
1. 0712E-07 6.8860E-08 6.7443E-08
1. 2741E-07 6.9893E-08 l.8578E-07 1.1156E-07 l.2816E-07 Page :

7 29-MAY-2014 14:47:30