UNITED STATES NUCLEAR REGULATORY COMMISSION

REGION V

1990 N. CALIFORNIA BOULEVARD SUITE 202, WALNUT CREEK PLAZA WALNUT CREEK, CALIFORNIA 94596 February 13, 1981 Docket No. 50-206 Southern California Edison Company P. 0. Box 800 2244 Walnut Grove Avenue Rosemead, California 91770 Attention:

Dr. L. T. Papay Vice President, Advanced Engineering Gentlemen:

Subject:

NRC Inspection - San Onofre Unit 1 ~U--C)~

This refers to the inspection conducted by Mr. G. P. Yuhas of this office on January 19-23, 1981 of activities authorized by NRC License No. DPR-13, and to the discussion of our findings held by Mr. G. P. Yuhas with Mr. J.M. Curran and other members of your staff at the conclusion of the inspectio Areas examined during this inspection are described in the enclosed inspection report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, in-terviews with personnel, and observations by the inspecto No items of noncompliance with NRC requirements were identified within the scope of this inspectio In accordance with Section 2. 790 of the NRC 1 s II Rules of Practice/'

Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Roo If this report contains any information that you believe to be proprietary, it is necessary that you submit a written application to this office, within 20 days of the date of this letter, requesting that such information be withheld from public disclosure. The application must include a full statement of the reasons why it is claimed that the information is proprietary. The application should be prepared so that any proprietary information identified is contained in an enclosure to the application, since the application without the enclosure will also be placed in the Public Document Roo If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Roo Southern California Edison Company -2-FEB 1 3 1981 Should you have any questions concerning this inspection, we will be glad to discuss them with yo

Enclosure:

IE Inspection Report No. 50-206/81-02

REGION V==

  • Report N /81-02 Docket N License No. __

D_PR_-_1_3 ___ Safeguards Group __ _

Licensee:

Southern California Edison Company 2244 Walnut Grove Avenue Rosemead, California 91770 Facility Name:

San Onofre Unit 1 (SONGS-lJ Inspection at:

Camp Pendleton, California Inspection conducted:

January 19-23, 1981 Inspectors:

l-J3- ]$\\

Date Signed Approved by: _Ii_.___.,!/.._.' _fti;:_..._4_..'1.4,,_~

..............

4 __ ~

.......... -~------

F. A. Wenslawski, Chief, Reactor Radiation Safety Section~ /1 !, ~ Approved by: ____ /'t

__

'+-~---kf-__

tro-1(

________ _

Summary:

H. E. Book, Chief, Fuel Facility and Materials Safety Branch Inspection on January 19-23, 1981 - Report No. 50-206/81-02 Date Signed Date Signed Areas Inspected: Routine unannounced inspection by a regional based inspector of the radiation protection program during major outage conditions; response to IE Circulars 80-03, 80-14, and 80-18; review of Licensee Event Report 80-37; and followup on previous inspection finding The inspection involved 38 inspector-hours onsit Results Of the areas inspected, no items of noncompliance were identifie RV Form 219 (2J

DETAILS Persons Contacted

  • J. G. Haynes, Manager, Nuclear Operations
  • H. L. Ottoson, Manager, Nuclear Engineering and Safety
  • J. M. Curran, Plant Manager, San Onofre
  • R. R. Brunet, Superintendent, Unit 1 H. B. Ray, Steam Generator Repair Project Manager
  • R. V. Warnock, Radiation Protection Supervisor M. Wharton, Supervising Engineer, Unit l
  • W. G. Frick, Compliance Engineer
  • J. D. Dunn, Project Quality Assurance Supervisor
  • D. D. Duran, Engineer
  • E. J. Bennett, Radiation Protection Foreman
  • Denotes those individuals attending the exit interview on January 23, 198 In addition to the individuals noted above, the inspector met with other members of the licensee's and contractor's staff.

Licensee Response to IE Circulars IE Circular No. 80-03, "Protection from Toxic Gas Hazards", was received and reviewed by the licensee. Primary responsibility for performance of the NRC recorrrnended action was assigned to the corporate Nuclear Engineering Staff. The inspector reviewed a draft report prepared by a contractor which addressed the toxic gas issue. This report had also been reviewed by the onsite licensee representatives. The report and the licensee's comments were responsive to the circular guidance. A corporate Nuclear Engineering staff representatfve informed the inspector that their January 1, 1981 date for issuance of an implementation schedule has been delayed to April 1, 198 Since appropriate corrective actions have not yet been finalized, this matter will be reviewed in a subsequent inspectio IE Circular No. 80-14, "Radioactive Contamination of Plant Demineralized Water System and Resultant Internal Contamination of Personnel",

was received by the licensee. Its review was assigned to an onsite individua From discussions with the assigned individual. the inspector learned that no action had yet taken plac The licensee's response to this Circular will be reviewed in a subsequent inspectio IE Circular No. 80-18, "10CFR50.59 Safety Evaluation for Changes to Radioactive Waste Treatment Systems", was received and reviewed by the licensee. The lfcensee's recommended action documented in a January 13, 1981 memorandum was to revise Station Order SOI-A-110,

"Organization and Responsibility of the Onsite Review Committee to

-2-include the guidance provided in this Circula The inspector discussed with licensee representatives the need to insure that individuals who are in a position to make field changes to radioactive waste treatment systems are aware of this guidance so that they may initiate the required safety evaluation. This item is considered close No items of noncompliance was identified in this are.

Licensee Event Report On October 27, 1980 the licensee submitted a report pursuant to Section 5.6.3b(3)(a) of Appendix B to Provisional Operating license DPR-13 that thermal measurement data required in Section 3. 1.1.a.(5)

of the Environmental Technical Specifications had not been collected on seven occasions during 197 From discussions with the Supervisory Research Scientist, the inspector confirmed that the reported corrective action to replace the aged detectors and deploy duplicate temperature sensors had been completed on July 3, 198 The licensee reported that the corrective action has been successful. The inspector had no further questions regarding this matte.

Licensee Action on Previous Inspection Findings

{Closed) (50-206/80-13-0l) Noncompliance, failure to adhere to Radiation Protection Procedure, S-VII-1.5 regarding smoking and drinking water in controlled areas. The licensee includes a warning regarding smoking in controlled areas in the training progra There are no longer any functioning drinking fountains in the controlled area. During tours of the controlled area, the inspector did not observe any indication of smokin (Closed)(S0-206/80-17-01) Noncompliance, failure to label containers of radioactive material. The inspector verified by record review that the two laborers, three contract radiation protection technicians, and the Radwaste Foreman had all received the specialized training described in the licensee's September 8, 1980 response lette No additional instances of improperly labeled containers of radioactive material were observed by the inspector during tours of the restricted are (.Closed)(S0-206/80-33-01) Inspector identified item involving the disposal of excavated material. During December 1980, about 100 cubic yards of sand, black top, and concrete were removed from a location near Unit 1 containment structure and dumped at a landfill on federal property near Jap Mes Based on review of licensee survey data, the inspector determined that trace quantities of radioactive material were probably present and that the aggregate

-3-sum of material present may have exceeded the values expressed in 10CFR20.304, "Disposal by burial in soil

  • The inspector brought these observations to the licensee's attention at the exit interview held on December 18, 198 The 1 i censee responded to this o_bserva tion by:

Prohibiting further disposal of excavated material originating at Unit 1 from being dumped at Jap Mes Identification, posting, and control of the material already dumped at the mesa so as to prevent its dispersio Collection of 13 samples from the dumped material for relative counting. Shipment of the highest activity sample to an independent laboratory for analysi Performing a direct radiation survey of the dumped materials with a low level survey instrumen On January 6, 1981, the licensee notified Region V that based on preliminary results of activity as reported by their independent laboratory, that all excavated materials which had been dumped would be drurrrned and shipped*to a licensed burial facilit During the course of this inspection, the inspector reviewed the licensee's data, perfonned independent radiation surveys using an Eberline PRM7 Micro 11 R 11 meter serial No. 453, calibrated December 15, 1980, and collected samples for analysis by NRC laboratory facilitie The highest concentration sample taken from the dumped excavated material at Jap Mesa was reported by the independent laboratory to have the following significant isotopic conten Isotope 40 K 54 Mn 58 Co 60 Co 134 Cs 137 Cs 144 Ce Activity pCi/gram 16.6 +.8 2. 2 +. 1 3. 9 +. 2 29 + T. o 8.8 +.4 26 +.5 +/-. * 2 These activities were used by the licensee to estimate the total activity shipped to the burial facilit The inspector reviewed the licensee's direct radiation survey performed on January 7, 1981, using a Ludlum Micro "R" meter prior

-4-to removal of the excavated materials. This survey indicated 8-12 pr/hr general background with twenty five readings taken on and around the dumped material ranging from 8 to 25 )Jr/h Review of radioactive material shipping records indicate that 390 fifty-five gallon drums containing a total of 7.5 mci of licensed material in 108 cubic yards of dirt were shipped from the dump site to a licensed burial facility in the period January 9 to January 15, 198 The licensee's resurvey of the area after drumming indicated 8-12 pr/h On January 20, 1981 the inspector perfonned an independent direct radiation survey consisting of 30 locations in the general area where the material had been dumpe This survey indicated radiation levels from 5-10 }Jr/hr with no statistically significant increase in the localized area from where the excavated materials had been remove On January 21, 1981 the inspector collected one square meter surface samples from the effected area and from an area considered to be backgroun The licensee was provided a fraction of each sample for comparative analysi NRC analysis of the samples performed at Region V using the ND6600/intrinsic germanium detector located in the mobile van indicate that virtually all the excavated material containing trace quantities of radionuclides had been effectively remove The residual activity is noted below:

Isotope 54 Mn 137 Cs 60 Co 109 Cd Activity pCi/gram

  • 04 + * 02
  • 53 +. 27
  • 57 +. 29

.* 1 !.. 05 Based on a weighted average technique, the licensee calculated that the mix of isotopes present in the removed material represented 773 times the values specified in lOCFR20 Appendix Review of regulatory requirements expressed in 10CFR20.304, "Disposal by burial in soil", indicates that if the licensee had bulldozed the piles of excavated materials into the fill area as is the common practice for clean fill from Units 2 and 3 a violation of regulatory requirements would likely have occurre Since the material was not buried, did not exceed the regulatory limits expressed in 10CFR20.105, "Permissible levels of radiation in unrestricted areas", and was completely removed in an expeditious manner, no item of noncompliance was identifie (0pen)(S0-206/80-26-09) Noncompliance, failure to make appropriate measurements of radioactivity in the body and measurements of radioactivity excreted from the body of those individuals involved in handling the NFS-4 NAC-IE cask on September 5, 198 On October 2, 1980 NRC Region V issued an Immediate Action Letter confirming actions the licensee agreed to take regarding the cas Item 3 of that letter stated that the licensee would make such measurements as necessary for them to evaluate the individuals' exposure in accordance with 10CFR20.10 In response to the above commitment, the licensee arranged through the U.S. Department of Energy for the individuals to receive a comprehensive series of measurements at Oak Ridge Associated Universitie The measurements were performed November 6 and 11, 198 They included a physical evaluation, cytogenetic study, whole body counting, and measurements of radioactivity excreted from the bod Based on the results of these measurements, the licensee concluded that neither individual received an intake of radioactive material in excess of the regulatory limit. The inspector reviewed the data and agreed that the licensee's conclusion was appropriat (Health Physics Appraisal, Inspection Report No. 50-206/80-17)

In a letter dated September 30, 1980, the licensee responded to the findings of that inspection. The inspector reviewed five co111T1itments presented in the response which were scheduled for completion in January 198 The first two areas reviewed involve reorganization of the facility staff and separation of the*station Nuclear Chemistry and Health Physics group Reorganization of the facility staff requires amendment of Section 6.2 of the Technical Specification As of January 26, 1981 a proposed amendment had been generated, reviewed and was expected to be forwarded to NRR for approval by January 30, 1981. Station Order SOI-E-211 which describes the duties and responsibilities for members of the radiation protection organization has been drafte Separation of the chemistry and radiation protection technicians has taken plac The licensee has implemented Health Physics Procedure SOI-VII-4.2,

"Bioassay Program".

Review of this procedure indicates that it may not provide sufficient direction to insure compliance

\\.,/'

with the requirements expressed in 10CFR20.103b(2). This was

.

brought to the licensee's attentio The licensee stated that an inventory, maintenance, and calibration program for health physics instruments will be established and

-6-implemented by January l, 198 In a letter dated January 15, 1981, \\

/

the licensee informed Region V that this program will not be

\\/'

in place until January 31, 198 Review of this commitment will take place in a subsequent inspection (50-206/81-02-0l).

A new high pressure baler was installed in the Auxiliary Building. The inspector reviewed Radiation Protection Procedure SOI-VII-1. 56, 11 Compacting Low Level Radioactive Waste", which directs operation of that equipmen No item of noncompliance was identified in this are.

Radiation Protection Activities On January 19, 1981 after normal working hours, the inspector made an unannounced radiation survey of the beach area adjoining the Tsunami wall to determine compliance with 10CFR20.10 The survey was performed using a PRM7 Mirco "R 11 portable survey instrumen CFR20.105(b)(2J permits a maximum radiation level of 100 mrem in any sevel consecutive days (0.595 mr/hr) in an unrestricted area unless otherwise authorized by the Commissio The maximum observed radiation level was 0.1 mr/hr at a position approximately 50 feet from the wall southwest of the Auxiliary Building. The 30 measurements ranged from 0.007 mr/hr to the maximum 0.1 mr/h The distribution of radiation levels appeared to indicate a localized source within the restricted area near the Auxiliary Buildin The inspector discussed the survey results with licensee representatives in terms of the ALARA criterion. Several licensee representatives stated that they felt the probable source of radiation was the Waste Monitor Tank On January 22, 1980 the inspector performed an independent survey of the Waste Monitor Tanks and Auxiliary Building area using a Keithley, Model 36100 Serial No. 9864 portable radiation survey instrument, calibrated January 6, 198 The average radiation level measured at contact with the exterior of the Waste Monitor Tanks was less than 30 mr/h The concrete block cubicle adjacent to the Auxiliary Building was found to have a general area radiation level ranging from 50 to 350 mr/hr on its roo The maximum observed contact measurement on the surface of this roof was 550 mr/hr. Since the entrance to this cubicle had a radiation level 420 mr/hr, the inspector did not perform a survey inside. A licensee representatives stated that the cubicle contained some fairly high level radioactive wast Based on the survey and discussions with licensee representatives, it appears that the high level radwaste storage cubicle is responsible for most of the radiation measured on the beac The inspector observed that the licensee had placed 3/8 inch sheet lead on the roof of this structure

-7-since the August inspection; however, the storage of high level waste appears one area worthy of additional review from an ALARA point of vie The inspector performed a tour of the controlled area including the containment on the evening of January 19, 198 During this tour, the inspector made independent radiation measurements to verify compliance with posting and control of radioactive material requirements expressed in 10CFR20.203, observed compliance with the licensee's radiation protection procedures, and re.viewed licensee survey record Radiation areas and radioactive materials were properly posted and controlled. Considerable ALARA effort was observed in the containment and steam generator work area Radiation survey records used by the Chemistry Radiation Protection Technicians to determine precautionary requirements for Radiation Exposure Permits were reviewe Surveys performed on December 17, 1980 January 10 and January 19, 1981 indicated2beta-gamma smearable activity from 50,000 to 500,000 dpm/lOOcm on the 38' and -10'

elevations of containment. These survey records did not include a measurement of alpha activity as required by Radiation Protection Procedure S-VII-1.13t Section IV, 10. This procedure requires an alpha count anytime the beta-ganvna activity exceeds 22,000 dpm/100cm2*

The surveys were performed by contractor Radiation Protection

Technician The survey records had other minor errors and omissions v/

and did not include any evidence that they had been reviewed by station personne The inspector questioned the Senior Radiation Protection Technician associated with the cadre of contractor technicians that had performed these surveys. This individual acknowledged that they had been trained in the licensee's survey techniques including procedure S-VII-1.13 and had errored with respect to the surveys in questio The individual stated that this same point had been brought to his attention earlier in the day by a licensee representativ The Radiation Protection Supervisor informed the inspector that his Acting Radiation Protection Foreman had identified this problem and was in the process of preparing a memorandum to reemphasize proper survey techniques and documentatio On the evening of January 21 1 1981 while performing a survey of the protected area, the inspector measured average radiation levels of 1.0 mr/hr inside the Security Escort Trailer. This trailer is located in close proximity to the R.E.D. Buildin In discussions with the Security Escort Shift Supervisor, the inspector was told

-8-that the trailer is occuppied 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> a day nonna11y by two individual Recently, the dose received by these individuals had increase Based on review of survey records dated December 21 and 23, 1980 and discussion with licensee representatives, it appears that the movement of steam generator grit tank, which read an average of 400 mr/hr on contact, from the containment on December 21, 1980 to the R.E.D. Building increased the dose rate in the trailer. Surveys performed on December 23, 1980 indicated a measurement of 4 mr/hr was made outside the R.E.D. Building near the trailer. Although no record indicates survey results inside the trailer, a licensee representative stated that he surveyed the trailer and posted it with a sign requiring personnel dosimetr He stated that no

'_ /

action was taken to reduce the radiation level inside the trailer V"

since he did not expect the grit tank to be in the R.E.D. Building very lon The inspector brought the licensee's attention to the apparent unnecessary exposure being received by occupants of the Security Escort Trailer. The licensee performed a survey of the situation and had the trailer moved to a low background area within the Protected Are On January 23, 1981, the inspector resurveyed the trailer and noted the average radiation level had decreased to 0.04 mr/h With regard to the steam generator repair project, survey data, operational experience and personnel exposures were examined and discussed with licensee and contractor representative Several additional positive steps have been accomplished to reduce exposures since the last inspection. These included revision of security escort practices and installation of the tube sheet shields. The revision of security escort practices is expected to save 20 person-re Installation of the tube sheet shield reduced the A steam generator dose rate from 2.8 to 1.6 r/hr. This will result in considerable exposure saving Additional area shielding has been installed and more channel head surface shielding is planne Review of actual versus projected radiation exposures associated with the steam generator repair project indicates that 820 person-rem have been incurred through January 21, 198 This is about 245 person-rem in excess of the November 16, 1980 dose projection. The excess 245 person-rem were primarily the result of program changes and process system failure The licensee is experiencing considerable difficulty in the brazing

\\

phase of the repair project. If the previous dose accumulation versus dose projections results continue during the sleeving phase

-9-then, in spite of the good ALARA engineering efforts, it appears the total dose projection of 1783 person-rem will be exceede No item of noncompliance was identified in this are.

Exit Interview The inspector met with the licensee representatives (denoted in Paragraph l) at the conclusion of the inspection on January 23, 198 The inspector summarized the scope and findings of the inspectio In addition, the inspector brought to the licensee's attention the somewhat subjective observation that there appears to be a deterioration in cooperation between licensee and contractor radiation protection

. __,.

personne The inspector noted that if this condition is real and

.......-

is allowed to continue, the positive improvements in the radiation protection program could be effected.