ML20034D971

From kanterella
Jump to navigation Jump to search
Sy C-HATCH 7-20 - Health Physics Sample Records
ML20034D971
Person / Time
Site: San Onofre  
Issue date: 06/18/2014
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034D971 (10)


Text

Sample ID:

142436 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 07 STAR 7-20 Dirt Sample

!Common]

Resp Org: P4000 - PROJECT MANAGEMEr

Contact:

COOPER, TERRY L Reference ID:

Comments:

Reviewed: DYNES, WILLIAM J Comments:

1*-origin l Mat. SizeNolume:

1000 ml

==

Description:==

STAR 02 SOIL SAMPLE I Collection I Sample Tech:

DYNES, WILLIAM J Tritium Req:

Instructions:

Comments:

COUNT TO MDA RLSSS Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes I Location I Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 05/29/14 11 :21 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 05/28/1413:07 Sample SizeNolume: 1797 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

~

Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth: 3" (in.)

Equip ID:

Date: 00/00/00 00:00 Other:

Material Loe:

06/18/201411:50 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Health Physics Sample Records Sample ID:

142436 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

1405288D 07 STAR 7-20 Dirt Sample

~aly~

Geometry ____ MCAID Quant.

Units Method FP/AP Lab Analysis By A_ 1 L_marinelli_sand -

30269 1797GR

.000 ABERNATHY, AGNES B Isotope Mode Activit~

Activity Uncert.

LLD/MDA

%Abund.

Atom. No.

Comments 0

K-40 NT 0.00001113 1.4E-6 r

80.245%

40 0

TL-208 NT 1.713E-7 7.65E-8 r

1.235%

208 0

PB-212 NT 5.552E-7 1.29E-7 r

4.003%

212 0

81-214 NT 4.754E-7 1.025E-7 r

3.428%

214 0

PB-214 NT 7.766E-7 1.41E-7 r

5.599%

214 0

AC-228 NT 7.616E-7 1.927E-7 r

5.491%

228 0

BE-7 AP 7.19E-7 Iv 0.000%

7 0

MN-54 AP 1.0786E-7 w

0.000%

54 0

MN-56 AP 7.2016E-8 w

0.000%

56 0

C0-57 AP 7.3632E-8 w

0.000%

57 0

C0-58 AP 9.0871E-8 w

0.000%

58 0

C0-60 AP 1.1196E-7 w

0.000%

60 0

SB-124 AP 2.1042E-8 w

0.000%

124 0

SB-125 FP 2.3439E-7 Iv 0.000%

125 0

CS-134 FP 5.4608E-8 Iv 0.000%

134 0

CS-137 FP 9.0421E-8 Iv 0.000%

137 Analysis Review I Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L HP Notified Name:

Hp Eng Rvw Reqd:

Yes Comments:

06/18/2014 11 :50 Rad Mat Present:

Yes Rasterized: r Date Mod ID Mod Date 05/29/14 16:03 Mod Id Mod Date Date: 06/10/14 09:46 Page 2 of 3

Sample ID:

142436 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 07 STAR 7-20 Dirt Sample I Review/AeproveJ Reviewed: COOPER, TERRY L Comments:

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/18/2014 11 :50 Health Physics Sample Records Status: APPROVED Rasterized:

HP Review Date: 06/10/14 09:46 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/10/14 09:46 Page 3 of3

SONGS HEALTH PHYSICS REPORT 29-MAY-2014 16:02

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140528BD 07 STAR 7-20 DIRT SAMPLE

  • ID 30269 Acquisition date: 29-MAY-2014 15:58:52 *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 29-MAY-2014 15:58:00 29-MAY-2014 15:58:00 Counting System 1.79700E+03 GR IHPS Sample Number:

A 11 marinelli_sand_l Analysis Library Operator: AGNES ABERNATHY U2GSP 142436 HP NATURAL

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.43 0 00:03:00.48 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 28-MAY-2014 21:10 2.58874E-01 4.99485E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 3

74.92 20 19

1. 04 149.48 143 20 42.8 1.19E+OO PB-212 PB-214 TL-208 3

77.19 30 17

1. 05 154.01 143 20 29.2 BI-214 PB-212 PB-214 1

238.82 60 29

1. 4 9 477.61 472 13 23.2 2.85E+OO PB-212 1

2 95. 11 31 0

2.22 590.31 585 10 18.2 9.27E-01 PB-214 1

352.02 35 2

1. 37 704.26 700 9 18.7 4.15E-01 PB-214 1

583.53 12 6

1. 31 1167.76 1163 8 44.7 8.07E-01 TL-208 1

609.36 26 2

1. 28 1219.48 1215 8 21. 6 6.20E-01 BI-214 1

910.99 19 2

2.38 1823.38 1819 9 25.3 4.69E-01 AC-228 1

1460.96 76 3

1. 94 2924.49 2918 13 12.6 4.50E-01 K-40

Summary of Nuclide Activity Sample ID : 30269 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :

2 29-MAY-2014 15:58:52 Number of lines tentatively identified by NID 9

0 9

100.00%

Nuclide Type : natural Uncorrected Nuclide Hlife Decay uCi/GR K-40 l.28E+09Y

1. 00 1.113E-05 TL-208 3.05M
1. 68 1.018E-07 PB-212 10.64H
1. 00 5.538E-07 BI-214 19.90M
1. 09 4.379E-07 PB-214 26.80M
1. 06 7.305E-07 AC-228 6,13H
1. 00 7.582E-07 Total Activity
1. 371E-05 Grand Total Activity:

1.371E-05 Flags: "K" "E"

Keyline not found Manually edited Decay Corr Decay Corr 1-Sigma uCi/GR 1-Sigma Error

%Error l.113E-05 0.140E-05 12.57

1. 713E-07 0.765E-07 44.69 5.552E-07 1.290E-07 23.23 4.754E-07 l.025E-07
21. 55 7.766E-07 l.410E-07 18.15 7.616E-07 1.927E-07 25.30 l.387E-05 1.387E-05 Manually accepted "M"

"A" Nuclide specific abn. limit Flags A

A A

A A

A

Unidentified Energy Lines Sample ID : 30269 None Flags: "T" Tentatively associated Acquisition date Page :

3 29-MAY-2014 15:58:52

Interference Report Sample ID : 30269 No interference correction performed Acquisition date Page :

4 29-MAY-2014 15:58:52

Nuclide Line Activity Report Page :

5 Sample ID : 30269 Acquisition date 29-MAY-2014 15:58:52 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 76 10.67*

5.314E-01

1. 113E-05 1.113E-05 12.57 TL-208
72. 80 2.14 l.594E+OO Line Not Found 74.97 20 3.60 1.690E+OO 2.794E-06 4.700E-06 42.76 84.79 ------
1. 27 2.058E+OO Line Not Found ------

252.45 ------

0.80 2.021E+OO Line Not Found ------

277.28 6.80 l.920E+OO ------

Line Not Found ------

510.61 ------

21. 60 1.265E+OO ------

Line Not Found ------

583.02 12 86.00*

1.127E+OO l.018E-07 1.713E-07 44.69 763.06 ------

1. 64 8.744E-01 ------

Line Not Found ------

860.30 ------

12.00 7.770E-01 ------

Line Not Found ------

PB-212 74.81 20 10.50

1. 690E+OO 9.579E-07 9.604E-07 42.76 77.11 30 17.70
1. 786E+OO 7.814E-07 7.834E-07 29.23 87.19 ------

6.27 2.129E+OO ------

Line Not Found ------*

90.13

1. 86 2.206E+OO Line Not Found ------

115.12 ------

0.59 2.535E+OO Line Not Found ------

238.58 60 43.60*

2.081E+OO 5.538E-07 5.552E-07 23.23 300.03 ------

3.34 1.834E+OO ------

Line Not Found ------

BI-214 76.86 30 0.58 1.786E+OO 2.385E-05 2.589E-05 29.23 79.29 ------

0.97 1.869E+OO Line Not Found ------

609.31 26 46.10*

1.084E+OO 4.379E-07 4.754E-07

21. 55 665.44
1. 56 9.985E-01 ------

Line Not Found ------

768.35 ------

4.88 8.685E-01 ------

Line Not Found ------

806.16 ------

1. 23 8.283E-01 ------

Line Not Found ------

934.04 3.16 7.177E-01 ------

Line Not Found ------

1120. 27 15.00 6.114E-01 ------

Line Not Found ------

1155. 18

1. 69 5.973E-01 Line Not Found ------

1238.11 ------

5.92 5.697E-01 ------

Line Not Found ------

1280.95 ------

1. 47 5.585E-01 Line Not Found ------

1377.66 ------

4.02 5.401E-01 ------

Line Not Found ------

1385. 30 0.78 5.391E-01 ------

Line Not Found ------

1401.48 ------

1. 39 5.370E-01 ------

Line Not Found ------

1407.97 ------

2.48 5.362E-01 ------

Line Not Found ------

1509.22 ------

2.19 5.292E-01 ------

Line Not Found 1583.22

0. 72 5.296E-01 ------

Line Not Found 1661. 26 1.15 5.351E-01 ------

Line Not Found ------

1729.58 3.05 5.442E-01 Line Not Found ------

1764.49 ------

15.90 5.503E-01 Line Not Found ------

1847.41 ------

2.12 5.694E-01 Line Not Found ------

PB-214 53.17 ------

1.10 5.543E-01 ------

Line Not Found ------

74.81 20 6.52 1.690E+OO l.543E-06

1. 640E-06 42.76 77.11 30
11. 00 1.786E+OO 1.257E-06 1.337E-06 29.23 87.19 ------

3.88 2.129E+OO Line Not Found ------

90.13 ------

1.15 2.206E+OO ------

Line Not Found ------

241.92 7.46 2.067E+OO Line Not Found ------

258.94 0.55 l.994E+OO Line Not Found ------

295.09 31 19.20*

1.852E+OO 7.305E-07 7.766E-07 18.15 351. 87 35 37.10 1.662E+OO 4.754E-07 5.054E-07 18.66 785.83

1. 09 8.495E-01 ------

Line Not Found ------

839.00 ------

0.59

7. 964E-01 Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30269 Acquisition date 29-MAY-2014 15:58:52 Nuclide Typo: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error AC-228

89. 96 3.40 2.201E+OO Line Not Found ------

93.35 5.60 2.279E+OO Line Not Found ------

99.55 ------

1. 30 2.389E+OO Line Not Found ------

105.36 ------

2.00 2.463E+OO Line Not Found ------

108.99 ------

0.67 2.496E+OO Line Not Found ------

129.03 ------

2.90 2.562E+OO Line Not Found ------

153.89 ------

0.84 2.496E+OO ------

Line Not Found ------

209.39 4.10 2.221E+OO Line Not Found ------

216.24 0.80 2.187E+OO Line Not Found ------

270.26 ------

3.80 l.948E+OO Line Not Found ------

328.07 ------

3.50 1.738E+OO Line Not Found ------

338.42 ------

12.40 1.704E+OO ------

Line Not Found 340.94 0.52

1. 696E+OO Line Not Found ------

409.62 2.20

1. 499E+OO Line Not Found ------

463.10 ------

4.60 l.368E+OO Line Not Found ------

562.65 ------

1. 01 1.164E+OO Line Not Found ------

581.52 ------

3.00 1.131E+OO ------

Line Not Found ------

72 6. 63 0.87 9.173E-01 ------

Line Not Found ------

755.28

1. 32 8.833E-01 ------

Line Not Found ------

772.28

1. 09 8.641E-01 ------

Line Not Found ------

782.12 ------

0.59 8.534E-01 ------

Line Not Found ------

794.79 ------

4. 60 8.400E-01 ------

Line Not Found ------

830.59 ------

0.63 8.043E-Ol Line Not Found ------

835.60

1. 71 7.996E-01 Line Not Found ------

840.44 0.94 7.951E-01 ------

Line Not Found ------

904.29 ------

0.89 7.403E-01 ------

Line Not Found ------

911.16 19 29.00*

7.350E-01 7.582E-07

7. 616E-07 25.30 964. 64 5.80
6. 962E-Ol ------

Line Not Found ------

968. 97 17.40 6.933E-01 Line Not Found ------

1246.60 ------

0.57 5.673E-01 Line Not Found ------

1459.19 ------

1. 06 5.315E-01 ------

Line Not Found ------

1496.00 ------

1. 05 5.296E-01 ------

Line Not Found ------

1501. 44 0.58 5.294E-01 ------

Line Not Found ------

1580.30 ------

0.71 5.295E-01 ------

Line Not Found ------

1588.23 ------

3.60 5.298E-01 ------

Line Not Found ------

1630.47

1. 95 5.324E-01 ------

Line Not Found ------

1638.10 ------

0.54 5.330E-01 Line Not Found ------

Flag:

II* II = Keyline

Minimum Detectable Activity Report Page :

7 Sample ID 30269 Acquisition date 29-MAY-2014 15:58:52 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

4.

477.61 7.1900E-07 MN-54

3.

834.83 1.0786E-07 MN-56

1.

846.81 7.2016E-08 C0-57

13.

122.06 7.3632E-08 C0-58

2.

810.79

9. 0871E-08 C0-60
1.

1332.50 1.1196E-07 SB-124

0.

602.73 2.1042E-08 SB-125

4.

427.88 2.3439E-07 CS-134

1.

604. 71 5.4608E-08 CS-137

2.

661.66 9.0421E-08