ML20034E242

From kanterella
Jump to navigation Jump to search
Sy C-HATCH 11-20 - Health Physics Sample Records
ML20034E242
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 05/16/2016
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034E242 (5)


Text

Health Physics Sample Records Sample ID: 142441 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

1405288D 11 STAR 11-20 Dirt Sample lcommonl Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N

Contact:

COOPER, TERRY L .survey No:

Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 05/30/14 08:03 Comments:

Origin Mat. SizeNolume: 1586 ml Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00

Description:

STAR 11 SOIL SAMPLE I Collectionl Sample Tech: DYNES, WILLIAM J Sample Date: 05/29/14 07:10 Count Time: 900 (secs.)

Tritium Req: No Sample SizeNolume: 1586 GRAMS Instructions:

Comments: COUNT TO MDA RLSSS I Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~

ILocaiionl Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: 3" (in.) Equip ID:

Stored By:, Date: 00/00/00 00:00 Sample Loe:

Other:

Material Loe:

06/18/201411:52 Page 1 of 3

Health Physics Sample Records Sample ID: 142441 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

1405288D 11 STAR 11-20 Dirt Sample Analysis Geometry MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date A_1L_marinelli_sand- 30280 1586GR .000 HENDERSON, JOE C 05/30/14 12:58 Isotope Mode Activity_ Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.00001053 1.35E-6 r 67.732% 40 0 TL-208 NT 2.251E-7 8.54E-8 r 1.448% 208 0 PB-212 NT 4.418E-7 1.011 E-7 r 2.842% 212 0 Bl-214 NT 4.115E-7 1.059E-7 r 2.647% 214 0 PB-214 NT 4.717E-7 1.842E-7 r 3.034% 214 0 RA-226 NT 2.639E-6 9.87E-7 r 16.975% 226 0 AC-228 NT 6.642E-7 1.792E-7 r 4.272% 228 0 U-235 NT 1.633E-7 6.11E-8 r 1.050% 235 0 BE-7 AP 5.9839E-7 ~ 0.000% 7 0 MN-54 AP 1.4412E-7 ~ 0.000% 54 0 MN-56 AP 8.9629E-8 ~ 0.000% 56 0 C0-57 AP 6.1853E-8 ~ 0.000% 57 0 C0-58 AP 8.4741E-8 ~ 0.000% 58 0 C0-60 AP 4.6633E-8 P" 0.000% 60 0 SB-124 AP 7.2542E-8 w 0.000% 124 0 SB-125 FP 2.1641E-7 Iv'" 0.000% 125 0 CS-134 FP 8.2266E-8 w 0.000% 134 0 CS-137 FP 1.4465E-7 P" 0.000% 137 I A11a.lysis Review I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/14 09:55 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:

Comments:

06/18/201411:52 Page 2 of 3

Health Physics Sample Records Sample ID: 142441 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140528BD 11 STAR 11-20 Dirt Sample I Review!Ap-prove I HP Review Reviewed: COOPER, TERRY L Date: 06/10/14 09:56 Comments: U-235 is likely mis-lD'd from Ac-228 and Rn-226 peaks Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:

Final Approval Approved: COOPER, TERRY L Date: 06/10/14 09:57 Comments:

06/18/2014 11 :52 Page 3 of 3

  • SONGS HEALTH PHYSICS REPORT 30-MAY-2014 12:48 *
  • >>>>> SAMPLE PARAMETERS<<<<< *
  • Title 140528BD 11 STAR 11-20 DIRT SAMPLE *
  • ID 30280 Acquisition date: 30-MAY-2014 12:45:07 *
  • Start Time: 30-MAY--2014 12: 45: 00 *
  • Stop Time: 30-MAY-2014 12:45:00 Counting System U2GSP *
  • Quantity 1. 58600E+03 GR IHPS Sample Number: 142441 *
  • Geometry A lL marinelli sand 1 Analysis Library HP NATURAL *
  • Operator: JOE HENDERSON *
  • >>>>> A #41-TP11679B PARAMETERS<<<<< *
  • Elapsed Live Time 0 00:03:00.42 Calibration 29-MAY-2014 23:37 *
  • Elapsed Real Time 0 00:03:00.46 Energy Offset 2.56487E-01 *
  • Deadtime 0.0% Energy Slope 4.99495E-01 *
  • Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1.00000 *
  • Half Life Ratio 8.00000 Sensitivity 5.00000
  • Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 92.77 30 25 2.19 185.21 181 9 35.1 2.98E+OO AC-228 U-235 1 186.19 21 12 1. 48 372. 25 367 10 37.4 1.08E+OO U-235 RA-226 1 238.66 42 16 1.14 477.29 473 8 22.9 2.95E+OO PB-212 1 241.78 18 8 1. 67 483.54 481 7 38.6 1. 08E+OO PB-214 1 295.00 17 9 1. 78 590.10 586 9 39.0 8.69E-Ol PB-214 1 338.03 15 0 1. 38 67 6. 25 673 6 27.0 l.87E+OO AC-228 1 351.95 24 11 1. 33 704.12 699 9 31.1 5.03E-01 PB-214 1 583.14 16 7 1. 74 1166.98 1163 9 37.9 2.71E+OO TL-208 1 609.45 21 2 1. 27 1219.66 1215 9 25.7 6.lOE-01 BI-214 1 1460.82 63 0 1. 96 2924.35 2919 10 12.9 1.49E+OO K-40

Summary of Nuclide Activity Page : 2 Sample ID : 30280 Acquisition date 30-MAY-2014 12:45:07 Total number of lines in spectrum 10 Number of unidentified lines 0 Number of lines tentatively identified by NID 10 100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 l.28E+09Y 1. 00 1.053E-05 l.053E-05 0.135E-05 12.85 A TL-208 3.05M 1. 42 l.587E-07 2.251E-07 0.854E-07 37.91 A PB-212 10.64H 1. 00 4.410E-07 4.418E-07 1. OllE-07 22.88 A BI-214 19.90M 1. 06 3.890E-07 4 .115E-07 l.059E-07 25.74 A PB-214 26.80M 1. 04 4.524E-07 4. 71 7E-07 1. 842E*-07 39.05 A RA-226 1600.00Y 1. 00 2.639E-06 2.639E-06 0.987E-06 37.40 A AC-228 6.13H 1. 00 6.621E-07 6.642E-07 l.792E-07 26.98 KA U-235 7.04E+08Y 1. 00 1.633E-07 l.633E-07 0. 611E-07 37.40 A Total Activity 1.544E-05 l.555E-05 Grand Total Activity : 1.544E-05 1.555E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit