ML20034E014
Text
Health Physics Sample Records Sample ID: 142505 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140606148D 05 NORTH LAYDOWN # 9
[Common Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 06/09/14 08:27 Comments: COUNT TO MDA LQ.r:igin l Mat. SizeNolume: 2041 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
NORTH LAYDOWN #9
[Collecti~~
Sample Tech: DYNES, WILLIAM J Sample Date: 06/06/1410:00 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 2041 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA RLSSS I Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: 1'i" ILocationl Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other: COUNT TO MDA Material Loe:
06/19/2014 09:03 Page 1 of 3
Health Physics Sample Records Sample ID: 142505 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
14060614BD 05 NORTH LAYDOWN # 9 IAnalysisl Geometry MCA ID Quant. Units Method FP/AP Lab Analy~i~_}' Date Mod ID Mod Date C_1 L_marinelli_sand_ 30425 2041 GR .000 NEEBE, DAVID J 06/09/14 20:43
_lsotop~ _Mod~_ Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 8.416E-6 1.028E-6 - 59.933% 40 0 TL-208 NT 1.965E-7 6.11 E-8 r 1.399% 208 0 PB-212 NT 7.808E-7 9.71E-8 5.560% 212 0 Bl-214 NT 3.825E-7 8.18E-8 2.724% 214 0 PB-214 NT 7.435E-7 1.821 E-7 5.295% 214 0 RA-226 NT 2.861 E-6 1.147E-6 20.374% 226 0 AC-228 NT 4.851E-7 1.735E-7 3.455% 228 0 U-235 NT 1.77E-7 7.1 E-8 1.260% 235 0 BE-7 AP 5.4378E-7 Iv 0.000% 7 0 MN-54 AP 4.9818E-8 w 0.000% 54 0 MN-56 AP 2.517E-8 w 0.000% 56 0 C0-57 AP 8.0595E-8 Iv 0.000% 57 0 C0-58 AP 8.7156E-8 Iv 0.000% 58 0 C0-60 AP 8.9426E-8 Iv 0.000% 60 0 SB-124 AP 6.5107E-8 Iv 0.000% 124 0 SB-125 FP 9.8885E-8 Iv 0.000% 125 0 CS-134 FP 6.7602E-8 Iv 0.000% 134 0 CS-137 FP 9.0076E-8 Iv 0.000% 137
[Analysis Review I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER. TERRY L Date: 06/11/14 08:01 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/19/2014 09:03 Page 2 of 3
Health Physics Sample Records Sample ID: 142505 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
14060614BD 05 NORTH LAYDOWN # 9 I__ Re~ew/Ap_p_rove I HP Eng Review Reviewed: COOPER, TERRY L Date: 06/11/14 08:02 Comments: U-235 is likely mis-lD'd off the Ra-226 energy peak Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
~~~~~~~~-F_i_n_al~Appro~v~a~I~~~~~~~~~~~~--~~~~~~~~~
Approved: COOPER, TERRY L Date: 06/11/14 08:02 Comments:
06/19/2014 09:03 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT 9-JUN-2014 20:39 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 14060614BD 05 NORTH LAYDOWN # 9 *
- ID 30425 Acquisition date: 9-JUN-2014 20:36:41. *
- Start Time: 9-JUN-2014 20:36:00. *
- Stop Time: 9-JUN-2014 20:36:00. Counting System U2GSP *
- Quantity 2.04100E+03 GR IHPS Sample Number: 142505 *
- Geometry C lL marinelli_sand_l Analysis Library HP NATURAL *
- Operator: DAVID NEEBE *
- >>>>> C #41-TP11750A PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.43 Calibration 9-JUN-2014 19:38: *
- Elapsed Real Time 0 00:03:00.48 Energy Offset -1.08890E-01 *
- Deadtime 0.0% Energy Slope 4.99807E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1.00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides PB-214 1 186.32 29 31 1. 94 372.98 368 10 40.1 4.42E+OO U-235 RA-226 1 238.49 95 17 1.17 477.36 474 8 12.4 7.98E-01 PB-212 1 295.07 34 10 1. 33 590.55 586 10 24.5 7.29E-01 PB-214 1 351.91 47 11 1. 73 704.26 700 9 19.2 3.29E-01 PB-214 1 583.37 16 2 1. 40 1167.26 1162 10 31.1 8.84E-01 TL-208 1 609.62 25 0 1. 51 1219.76 1215 9 21. 4 1. 30E+OO BI-214 1 911. 21 14 4 1. 99 1822.97 1818 9 35.8 1.45E+OO AC-228 1 1461.06 68 0 1. 75 2922.52 2917 12 12.2 3.16E-01 K-40
Surrunary of Nuclide Activity Page : 2 Sample ID : 30425 Acquisition date 9-JON-2014 20:36:41 Total number of lines in spectrum 9 Number of unidentified lines 0 Number of lines tentatively identified by NID 9 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 l.28E+09Y 1. 00 8.416E-06 B.416E-06 1. 028E-06 12.21 A TL-208 3.05M 1. 62 1. 216E-07 l.965E-07 0. 611E-07 31. OB A PB-212 10.64H 1. 00 7.789E-07 7.BOBE-07 0.971E-07 12.44 A BI-214 19.90M 1. OB 3.545E-07 3.825E-07 0. BlBE-07 21. 38 A PB-214 26.BOM 1. 06 7.026E-07 7.435E-07 l.821E-07 24.49 A RA-226 1600.00Y 1. 00 2.861E-06 2.861E-06 1.147E-06 40.10 A AC-228 6.13H 1. 00 4.830E-07 4.851E-07 1. 735E-07 35.77 A 0-235 7.04E+08Y 1. 00 1.770E-07 l.770E-07 0. 710E-07 40.10 A Total Activity 1.389E-05 1.404E-05 Grand Total Activity : 1.389E-05 l.404E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30425 Acquisition date 9-JUN-2014 20:36:41 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30425 Acquisition date 9-JUN-2014 20:36:41 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30425 Acquisition date 9-JUN-2014 20:36:41 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 68 10.67* 5.560E-01 8.416E-06 8.416E-06 12.21 TL-208 72. 80 ------ 2.14 1.486E+OO ------ Line Not Found ------
74.97 ------ 3.60 l.577E+OO ------ Line Not Found ------
84.79 ------ 1. 27 1.917E+OO ------ Line Not Found ------
252.45 ------ 0.80 2.004E+OO ------ Line Not Found ------
277.28 ------ 6.80 l.917E+OO ------ Line Not Found ------
510.61 ------ 21. 60 l.298E+OO ------ Line Not Found ------
583.02 16 86.00* 1.157E+OO l.216E-07 1. 965E-07 31.08 763.06 ------ 1. 64 8.934E-01 ------ Line Not Found ------
860.30 ------ 12.00 7.922E-01 ------ Line Not Found ------
PB-212 74.81 ------ 10.50 1.570E+OO ------ Line Not Found ------
77 .11 0 17.70 1.690E+OO O.OOOE+OO O.OOOE+OO 0.00 87.19 ------ 6.27 1. 983E+OO ------ Line Not Found ------
90.13 ------ 1. 86 2.055E+OO ------ Line Not Found ------
115. 12 ------ 0.59 2.376E+OO ------ Line Not Found ------
238.58 95 43.60* 2.055E+OO 7.789E-07 7.808E-07 12.44 300.03 ------ 3.34 l.843E+OO ------ Line Not Found ------
BI-214 76.86 ------ 0.58 1.651E+OO ------ Line Not Found ------
79.29 ------ 0.97 1.741E+OO ------ Line.Not Found ------
609.31 25 46.10* 1. lllE+OO 3.545E-07 3.825E-07 21. 38 665.44 ------ 1. 56 1.023E+OO ------ Line Not Found ------
768.35 ------ 4.88 8.873E-01 ------ Line Not Found ------
806.16 ------ 1. 23 8.454E-01 ------ Line Not Found ------
934.04 ------ 3.16 7.310E-01 ------ Line Not Found ------
1120.27 ------ 15.00 6.242E-01 ------ Line Not Found ------
1155. 18 ------ 1. 69 6.105E-01 ------ Line Not Found ------
1238 .11 ------ 5.92 5.846E-01 ------ Line Not Found ------
1280.95 ------ 1. 4 7 5.747E-01 ------ Line Not Found ------
1377.66 ------ 4.02 5.602E-01 ------ Line Not Found ------
1385.30 ------ 0.78 5.595E-01 ------ Line Not Found ------
1401.48 ------ 1. 39 5.583E-01 ------ Line Not Found ------
1407.97 ------ 2.48 5.578E-01 ------ Line Not Found ------
1509.22 ------ 2.19 5.568E-01 ------ Line Not Found ------
1583.22 ------ 0. 72 5.628E-01 ------ Line Not Found ------
1661. 26 ------ 1.15 5.753E-01 ------ Line Not Found ------
1729.58 ------ 3.05 5. 918E-01 ------ Line Not Found ------
1764.49 ------ 15.90 6.023E-01 ------ Line Not Found ------
1847.41 ------ 2.12 6.331E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 5.203E-01 ------ Line Not Found ------
74.81 ------ 6.52 1.570E+OO ------ Line Not Found ------
77.11 0 11. 00 1.690E+OO O.OOOE+OO O.OOOE+OO 0.00 87.19 ------ 3.88 l.983E+OO ------ Line Not Found ------
90.13 ------ 1.15 2.055E+OO ------ Line Not Found ------
241. 92 ------ 7.46 2.043E+OO ------ Line Not Found ------
258.94 ------ 0.55 1.981E+OO ------ Line Not Found ------
295.09 34 19.20* l.859E+OO 7.026E-07 7.435E-07 24.49 351.87 47 37.10 '1.686E+OO 5.481E-07 5.800E-07 19.19 785.83 ------ 1. 09 8.674E-01 ------ Line Not Found ------
839.00 ------ 0.59 8.122E-01 ------ Line Not Found ------
Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30425 Acquisition date 9-JUN-2014 20:36:41 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error RA-226 81. 07 ------ 0.18 1.802E+OO ------ Line Not Found ------
186.11 29 3.28* 2.260E+OO 2.861E-06 2.861E-06 40.10 AC-228 89.96 ------ 3.40 2.051E+OO ------ Line Not Found ------
93.35 ------ 5.60 2.124E+OO ------ Line Not Found ------
99.55 ------ 1. 30 2.229E+OO ------ Line Not Found ------
105.36 2.00 2.301E+OO ------ Line Not Found ------
108.99 ------ 0.67 2.335E+OO ------ Line Not Found ------
129.03 ------ 2.90 2.414E+OO ------ Line Not Found ------
153.89 ------ 0.84 2.377E+OO ------ Line Not Found ------
209.39 ------ 4.10 2.168E+OO ------ Line Not Found ------
216.24 ------ 0.80 2.141E+OO ------ Line Not Found ------
270.26 ------ 3.80 1.941E+OO ------ Line Not Found ------
328.07 ------ 3.50 1.756E+OO ------ Line Not Found ------
338.42 12.40 1.725E+OO ------ Line Not Found ------
340.94 ------ 0.52 1.718E+OO ------ Line Not Found ------
409.62 2.20 1.531E+OO ------ Line Not Found ------
463.10 4. 60 1.401E+OO ------ Line Not Found ------
562.65 ------ 1. 01 1.195E+OO ------ Line Not Found ------
581. 52 ------ 3.00 l.160E+OO ------ Line Not Found ------
726.63 0.87 9.382E-01 ------ Line Not Found ------
755.28 ------ 1. 32 9.027E-Ol ------ Line Not Found ------
772. 28 ------ 1. 09 8.827E-01 ------ Line Not Found ------
782.12 0.59 8, 716E-01 ------ Line Not Found ------
794.79 4. 60 8.576E-01 ------ Line Not Found ------
830.59 0.63 8.205E-01 ------ Line Not Found ------
835.60 ------ 1. 71 8.155E-01 ------ Line Not Found ------
840.44 ------ 0.94 8.108E-01 ------ Line Not Found ------
904.29 ------ 0.89 7.542E-01 ------ Line Not Found ------
911.16 14 29.00* 7.486E-01 4.830E-07 4.851E-07 35.77 964.64 ------ 5.80 7.091E-01 ------ Line Not Found ------
968. 97 17.40 7.061E-01 ------ Line Not Found ------
1246.60 ------ 0.57 5.825E-01 ------ Line Not Found ------
1459.19 ------ 1. 06 5.560E-01 ------ Line Not Found ------
1496. 00 ------ 1. 05 5.563E-01 ------ Line Not Found ------
1501. 44 ------ 0.58 5.565E-01 ------ Line Not Found ------
1580.30 ------ 0.71 5.624E-01 ------ Line Not Found ------
1588.23 3.60 5.634E-01 ------ Line Not Found ------
1630.47 ------ 1. 95 5. 696E-01 ------ Line Not Found ------
1638.10 0.54 5.709E-01 ------ Line Not Found ------
U-235 89. 96 ------ 3.36 2.051E+OO Line Not Found ------
93.35 ------ 5.50 2.124E+OO Line Not Found ------
105.36 ------ 1. 98 2.301E+OO ------ Line Not Found ------
109.18 ------ 1. 50 2.336E+OO ------ Line Not Found ------
143.79 ------ 10.50 2.402E+OO ------ Line Not Found ------
163.38 ------ 4.70 2.347E+OO ------ Line Not Found ------
185.74 29 53.00* 2.260E+OO 1.770E-07 1.770E-07 40.10 194. 96 ------ 0.59 2.226E+OO ------ Line Not Found ------
202.13 ------ 1. 00 2.197E+OO ------ Line Not Found ------
205.33 4.70 2.184E+OO ------ Line Not Found ------
Nuclide Line Activity Report (continued) Page : 7 Sample ID : 30425 Acquisition date 9-JUN-2014 20:36:41 Flag: "*" Keyline
Minimum Detectable Activity Report Page : 8 Sample ID 30425 Acquisition date 9-JON-2014 20:36:41 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 3. 477.61 5.4378E-07 MN-54 0. 834.83 4.9818E-08 MN-56 0. 846.81 2.5170E-08 C0-57 18. 122.06 8.0595E-08 C0-58 2. 810.79 8. 7156E-08 C0-60 1. 1173.24 8.9426E-08 SB-124 2. 602.73 6.5107E-08 SB-125 0. 600.50 9.8885E-08 CS-134 3. 604. 71 6.7602E-08 CS-137 3. 661.66 9.0076E-08