Health Physics Sample Records Sample ID: 142453 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
14053080 info 2 STARYARD L~ommon Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: Y
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 05/30/14 12:17 Comments:
LOri9l!!
Mat. SizeNolume: 2167 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
INFO 2 STARYARD Collection Sample Tech: DYNES, WILLIAM J Sample Date: 05/30/1410:45 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 2167 GRAMS Instructions:
Comments: COUNT TO MDA
[Rlsssl Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: w I Location I Unit: NON-UNIT RE Area: Elev: 100 Room: Depth: 3" (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other:
Material Loe:
06/18/2014 14:18 Page 1 of 3
Health Physics Sample Records Sample ID: 142453 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140530BD info 2 STARYARD
]Analysis I Geometry MCA ID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date A_1L_marinelli_sand_ 30283 2167GR .000 HENDERSON, JOE C 05/30/1413:13 lsoto~ Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.00002332 1.75E-6 7.164% 40 0 TL-208 NT 5.007E-7 1.155E-7 0.154% 208 0 Bl-212 NT 2.03E-6 7.29E-7 0.624% 212 0 PB-212 NT 1.586E-6 1.37E-7 r 0.487% 212 0 Bl-214 NT 8.981E-7 1.462E-7 0.276% 214 0 PB-214 NT 1.094E-6 2.24E-7 r 0.336% 214 0 RN-222 NT 0.0002893 0.000064 r 88.870% 222 0 RA-226 NT 4.984E-6 1.509E-6 1.531% 226 0 AC-228 NT 1.511E-6 2.69E-7 r 0.464% 228 0 U-235 NT 3.085E-7 9.34E-8 r 0.095% 235 0 BE-7 AP 6.8902E-7 Iv 0.000% 7 0 MN-54 AP 1.0383E-7 Iv 0.000% 54 0 MN-56 AP 1.2122E-7 fi1' 0.000% 56 0 C0-57 AP 1.0696E-7 IV 0.000% 57 0
0 C0-58 C0-60 AP AP 8.1202E-8 1.5785E-7 "'
Iv 0.000%
0.000%
58 60 0 SB-124 AP 8.3402E-8 IV 0.000% 124 0 SB-125 FP 2.7914E-7 Iv 0.000% 125 0 CS-134 FP 9.761E-8 IV 0.000% 134 0 CS-137 FP 1.3446E-7 Iv 0.000% 137
[__ Analysis Review I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/1410:35 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/18/2014 14:18 Page 2 of 3
Health Physics Sample Records Sample ID: 142453 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140530BD info 2 STARYARD I Review/Approve I HP Eng Review Reviewed: COOPER, TERRY L Date: 06/10/1410:35 Comments: U-235 is likely mis-lD'd from Ac-228 and Ra-226 peaks Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/10/1410:36 Comments:
06/18/2014 14:18 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT 30-MAY-2014 13:02 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 140530BD INFO 2 STARYARD *
- ID 30283 Acquisition date: 30-MAY-2014 12:59:51 *
- Start Time: 30-MAY-2014 12:59:00 *
- Stop Time: 30-MAY-2014 12:59:00 Counting System U2GSP *
- Quantity 2.16700E+03 GR IHPS Sample Number: 142453 *
- Geometry A lL marinelli sand 1 Analysis Library HP NATURAL *
- Operator: JOE HENDERSON *
- >>>>> A #41-TP11679B PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.32 Calibration 29-MAY-2014 23:37 *
- Elapsed Real Time 0 00:03:00.45 Energy Offset 2.56487E-01 *
- Deadtime 0.1% Energy Slope 4.99495E-Ol *
- Activity Mult Factor: l.OOOOOE+OO Energy Tolerance: 1.00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 77.15 76 121 0.87 153.94 151 7 26.7 3.09E+OO BI-214 PB-212 PB-214 1 92.94 85 101 1.81 185.56 182 9 24.2 6.08E-01 AC-228 U-235 1 186.33 55 56 1.42 372.53 368 11 30.3 1.63E+OO U-235 RA-226 1 238.60 208 50 1.12 477.17 472 31 8.6 2.04E+OO PB-212 1 241.91 29 41 1.15 483.80 472 31 42.6 PB-214 1 295.28 53 18 1.59 590.65 586 9 20.5 2.23E+OO PB-214 1 338.14 36 36 1.76 676.46 671 15 39.7 1.33E+OO AC-228 1 351. 88 104 28 1.26 703.98 699 11 13.8 6.27E-01 PB-214 1 510.42 37 7 2.69 1021.39 1015 13 22.1 5.06E-01 RN-222 TL-208 1 583.28 42 13 1.34 1167.27 1163 10 23.1 1.87E+OO TL-208 1 609.37 60 7 1. 77 1219. 51 1215 11 16.3 4.30E+OO BI-214 1 726.92 17 6 1. 65 1454. 87 1449 9 35.9 5.49E-01 AC-228 BI-212 1 795.45 16 4 2.13 1592.07 1588 9 33.5 1.09E+OO AC-228 1 911. 30 46 3 2.71 1824.03 1818 15 17.8 l.45E+OO AC-228 1 968.92 18 6 1. 56 1939. 40 1935 12 36.0 3.95E-01 AC-228 1 1119. 97 25 0 2. 03 2241. 85 2238 10 20.4 3.86E-01 BI-214 1 1460.66 191 3 1.87 2924.02 2918 12 7.5 4.94E-01 K-40 1 1764.55 17 0 1. 85 3532. 55 3528 8 22.4 3.30E-01 BI-214
Summary of Nuclide Activity Page : 2 Sample ID : 30283 Acquisition date 30-MAY-2014 12:59:51 Total number of lines in spectrum 18 Number of unidentified lines 0 Number of lines tentatively identified by NID 18 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y 1. 00 2.332E-05 2.332E-05 0.175E-05 7.51 A TL-208 3.05M 1. 68 2.985E-07 5.007E-07 l.155E-07 23.07 A BI-212 1.01H 1. 03 1.976E-06 2.030E-06 0.729E-06 35.94 A PB-212 10.64H 1. 00 l.582E-06 1.586E-06 0.137E-06 8.64 A BI-214 19.90M 1. 09 8.276E-07 8.981E-07 1. 4 62E-07 16. 28 A PB-214 2 6. SOM 1. 06 1.030E-06 1. 094E-06 0.224E-06 20.48 A RN-222 3.83D 1. 00 2.893E-04 2.893E-04 0.640E-04 22.12 A RA-226 1600.00Y 1. 00 4.984E-06 4.984E-06 l.509E-06 30.27 A AC-228 6.13H 1. 00 l.504E-06 1. SllE-06 0.269E-06 17.80 A U-235 7.04E+08Y 1. 00 3.085E-07 3.085E-07 0.934E-07 30.27 A Total Activity 3.251E-04 3.256E-04 Grand Total Activity : 3. 251E-04 3.256E-04 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30283 Acquisition date 30-MAY-2014 12:59:51 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30283 Acquisition date 30-MAY-2014 12:59:51 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30283 Acquisition date 30-MAY-2014 12:59:51 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 191 10.67* 5.314E-01 2.332E-05 2.332E-05 7.51 TL-208 72. 80 ------ 2.14 1.594E+OO ------ Line Not Found ------
74.97 ------ 3.60 1.692E+OO ------ Line Not Found ------
84.79 ------ 1. 27 2.058E+OO ------ Line Not Found ------
252.45 ------ 0.80 2.021E+OO Line Not Found ------
277.28 ------ 6.80 1.920E+OO Line Not Found ------
510.61 37 21. 60 1.265E+OO 9.374E-07 1.572E-06 22.12 583.02 42 86.00* 1.128E+OO 2.985E-07 5.007E-07 23.07 763.06 ------ 1. 64 8.744E-01 ------ Line Not Found ------
860.30 ------ 12.00 7.770E-01 ------ Line Not Found ------
BI-212 727.25 17 6.65* 9.170E-01 1.976E-06 2.030E-06 35.94 785.51 ------ 1.11 8.498E-01 ------ Line Not Found ------
1078.69 ------ 0.54 6.305E-01 ------ Line Not Found ------
1620.66 ------ 1. 51 5.316E-01 Line Not Found ------
PB-212 74.81 ------ 10.50 1.685E+OO Line Not Found ------
77 .11 76 17.70 1.784E+OO 1.669E-06 1.674E-06 26.68 87.19 ------ 6.27 2.129E+OO Line Not Found ------
90.13 ------ 1. 86 2.206E+OO ------ Line Not Found ------
115 .12 ------ 0.59 2.535E+OO ------ Line Not Found ------
238.58 208 43.60* 2.082E+OO 1.582E-06 1. 586E-06 8.64 300.03 ------ 3.34 1.834E+OO ------ Line Not Found ------
BI-214 76.86 76 0.58 1.784E+OO 5.095E-05 5.529E-05 26. 68 79.29 ------ 0.97 1.869E+OO Line Not Found ------
609.31 60 46.10* 1.084E+OO 8.276E-07 8.981E-07 16.28 665.44 ------ 1. 56 9.985E-01 Line Not Found ------
768.35 ------ 4.88 8.685E-01 Line Not Found ------
806.16 ------ 1. 23 8.283E-01 ------ Line Not Found ------
934.04 ------ 3.16 7.177E-01 ------ Line Not Found ------
1120.27 25 15.00 6.116E-01 1.882E-06 2.042E-06 20.43 1155.18 ------ 1. 69 5.973E-01 ------ Line Not Found ------
1238 .11 ------ 5.92 5.697E-01 Line Not Found ------
1280.95 ------ 1. 4 7 5.585E-01 Line Not Found ------
1377.66 ------ 4.02 5.401E-01 Line Not Found ------
1385.30 ------ 0.78 5.391E-01 Line Not Found ------
1401.48 ------ 1. 39 5.370E-01 ------ Line Not Found ------
1407.97 ------ 2.48 5.362E-01 ------ Line Not Found ------
1509.22 ------ 2.19 5.292E-01 ------ Line Not Found ------
1583.22 ------ 0. 72 5. 296E-01 ------ Line Not Found ------
1661.26 ------ 1.15 5.351E-01 Line Not Found ------
1729.58 ------ 3.05 5.442E-01 Line Not Found ------
1764.49 17 15.90 5.504E-01 1.369E-06 1.486E-06 22.36 1847.41 ------ 2.12 5.694E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 5.543E-01 ------ Line Not Found ------
74.81 ------ 6.52 1.685E+OO ------ Line Not Found ------
77.11 76 11. 00 1.784E+OO 2.686E-06 2.855E-06 26. 68 87.19 ------ 3.88 2.129E+OO ------ Line Not Found ------
90.13 ------ 1.15 2.206E+OO Line Not Found ------
241.92 29 7.46 2.067E+OO 1. 298E-06 1.379E-06 42.57 258.94 ------ 0.55 1.994E+OO ------ Line Not Found ------
- I Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30283 Acquisition date 30-MAY-2014 12:59:51 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error 295.09 53 19.20* 1.852E+OO 1. 030E-06 1.094E-06 20.48 351. 87 104 37.10 1.662E+OO 1.166E-06 1.239E-06 13.76 785.83 ------ 1. 09 8.495E-01 ------ Line Not Found ------
839.00 ------ 0.59 7. 964E-01 ------ Line Not Found ------
RN-222 510.00 37 0.07* 1.265E+OO 2.893E-04 2.893E-04 22.12 RA-226 81. 07 ------ 0.18 1.934E+OO ------ Line Not Found ------
186.11 55 3.28* 2.338E+OO 4.984E-06 4.984E-06 30.27 AC-228 89. 96 ------ 3.40 2.201E+OO ------ Line Not Found ------
93.35 85 5.60 2.270E+OO 4.644E-06 4.664E-06 24.24 99.55 ------ 1. 30 2.389E+OO ------ Line Not Found ------
105.36 ------ 2.00 2.463E+OO ------ Line Not Found ------
108.99 ------ 0.67 2.496E+OO ------ Line Not Found ------
129.03 ------ 2.90 2.562E+OO ------ Line Not Found ------
153.89 ------ 0. 8 4 2. 4 96E+OO ------ Line Not Found ------
209.39 ------ 4.10 2.221E+OO ------ Line Not Found ------
216.24 ------ 0.80 2.187E+OO ------ Line Not Found ------
270.26 ------ 3.80 1.948E+OO ------ Line Not Found ------
328.07 ------ 3.50 1.738E+OO ------ Line Not Found ------
338.42 36 12.40 1.705E+OO 1.167E-06 1.172E-06 39.71 340.94 ------ 0.52 1.696E+OO ------ Line Not Found ------
409.62 ------ 2.20 1.499E+OO ------ Line Not Found ------
463.10 ------ 4.60 1.368E+OO ------ Line Not Found ------
562.65 ------ 1. 01 1.164E+OO ------ Line Not Found ------
581.52 ------ 3.00 1.131E+OO ------ Line Not Found ------
726.63 17 0.87 9.170E-01 1.510E-05 1.517E-05 35.94 755.28 ------ 1. 32 8.833E-01 ------ Line Not Found ------
772.28 ------ 1. 09 8.641E-01 ------ Line Not Found ------
782.12 ------ 0.59 8.534E-01 ------ Line Not Found ------
794.79 16 4.60 8.393E-01 2.933E-06 2.946E-06 33.52 830.59 ------ 0.63 8.043E-01 ------ Line Not Found ------
835.60 ------ 1. 71 7. 996E-01 ------ Line Not Found ------
840.44 ------ 0. 94 7.951E-01 ------ Line Not Found ------
904.29 ------ 0.89 7.403E-01 ------ Line Not Found ------
911.16 46 29.00* 7.348E-01 1. 504E-06 1. 511E-06 17.80 964*. 64 ------ 5.80 6. 962E-01 ------ Line Not Found ------
968. 97 18 17.40 6.934E-01 1.055E-06 1.060E-06 36.03 1246.60 ------ 0.57 5.673E-01 ------ Line Not Found ------
1459.19 ------ 1. 06 5.315E-01 ------ Line Not Found ------
1496.00 ------ 1. 05 5.296E-01 ------ Line Not Found ------
1501. 44 ------ 0.58 5.294E-01 ------ Line Not Found ------
1580.30 ------ 0. 71 5.295E-01 ------ Line Not Found ------
1588.23 ------ 3.60 5.298E-01 ------ Line Not Found ------
1630.47 ------ 1. 95 5.324E-01 ------ Line Not Found ------
1638.10 ------ 0.54 5.330E-01 ------ Line Not Found ------
U-235 89. 96 ------ 3.36 2.201E+OO ------ Line Not Found ------
93.35 85 5.50 2.270E+OO 4.728E-06 4.728E-06 24.24 105.36 ------ 1. 98 2.463E+OO ------ Line Not Found ------
109.18 ------ 1. 50 2.498E+OO ------ Line Not Found ------
143.79 ------ 10.50 2.533E+OO ------ Line Not Found ------
Nuclide Line Activity Report (continued) Page : 7 Sample ID : 30283 Acquisition date 30-MAY-2014 12:59:51 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error 163.38 ------ 4.70 2.453E+OO ------ Line Not Found ------
185.74 55 53.00* 2.338E+OO 3.085E-07 3.085E-07 30.27 194. 96 ------ 0.59 2.294E+OO Line Not Found ------
202 .13 ------ 1. 00 2.257E+OO Line Not Found ------
205.33 ------ 4.70 2.241E+OO ------ Line Not Found ------
Flag: "*" Keyline
Minimum Detectable Activity Report Page : 8 Sample ID 30283 Acquisition date 30-MAY-2014 12:59:51 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 6. 477.61 6.8902E-07 MN-54 4. 834.83 1.0383E-07 MN-56 5. 846.81 1.2122E-07 C0-57 45. 122.06 1.0696E-07 C0-58 2. 810.79 8.1202E-08 C0-60 4. 1332.50 1.5785E-07 SB-124 5. 602.73 8.3402E-08 SB-125 10. 427.88 2.7914E-07 CS-134 7. 604. 71 9.7610E-08 CS-137 9. 661. 66 1.3446E-07