ML20034D991
Text
Health Physics Sample Records Sample ID: 142522 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140528BD 03 STAR YARD# 3-20
[Common]
Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: 142432 Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 06/11/1410:33 Comments: COUNT TO MDA I Or!Qin Mat. SizeNolume: 1816 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
STAR YARD# 3 Collection Sample Tech: DYNES, WILLIAM J Sample Date: 05/23/1412:48 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 1816 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA RLSSS)
Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~
ILocation Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:
Stored By:. Date: 00/00/00 00:00 Sample Loe:
Other: COUNT TO MDA Material Loe:
06/18/2014 12:45 Page 1 of 3
Health Physics Sample Records Sample ID: 142522 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
1405288D 03 STAR YARD# 3-20
[Analysis [
Geometry MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date A_1L_marinelli_sand- 1015 1000 gr .000 DYNES, WILLIAM J 06/11 /14 14:03 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 BE-7 AP 1.393E-6 4.11E-7 r 7.760% 7 0 K-40 NT 0.0000109 1.22E-6 r 60.722% 40 0 TL-208 NT 4.929E-7 1.119E-7 r 2.746% 208 0 PB-212 NT 6.869E-7 1.014E-7 r 3.827% 212 0 81-214 NT 6.623E-7 1.248E-7 r 3.690% 214 0 PB-214 NT 4.85E-7 2.183E-7 r 2.702% 214 0 RA-226 NT 2.663E-6 8.27E-7 r 14.835% 226 0 AC-228 NT 5.029E-7 3.466E-7 r 2.802% 228 0 U-235 NT 1.648E-7 5.55E-8 r 0.918% 235 0 MN-54 AP 7.4934E-8 jv 0.000% 54 0 MN-56 AP 2.2478E-8 IV 0.000% 56 0 C0-57 AP 7.6585E-8 IV 0.000% 57 0 C0-58 AP 1.0182E-7 w 0.000% 58 0 C0-60 AP 1.1046E-7 jv 0.000% 60 0 SB-124 AP 7.1267E-8 jv 0.000% 124 0 SB-125 FP 1.8533E-7 jv 0.000% 125 0 CS-134 FP 1.1345E-7 jv 0.000% 134 0 CS-137 FP 1.7609E-7 IV 0.000% 137 Analysis Review Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/17/14 13:53 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments: This is a replacement for ID# 142432 that had error in description (2-20 vs: 3-20) 06/18/2014 12:45 Page 2 of 3
Health Physics Sample Records Sample ID: 142522 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140528BD 03 STAR YARD# 3-20 r Review/Approve I HP Eng Review Reviewed: COOPER, TERRY L Date: 06/17/1413:54 Comments: U-235 likely mis-lD'd off Ra-226 energy peak. Be-7 is a natural product coming from cosmic ray interaction.
Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/17/14 13:54 Comments:
06/18/2014 12:45 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT ll-JUN-2014 10:54 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 140528BD 03 STAR YARD# 3-20 *
- ID 1013 Acquisition date: ll-JUN-2014 10:51:47 *
- Start Time: ll-JUN-2014 10:51:00 *
- Stop Time: ll-JUN-2014 10:51:00 Counting System UlGSP *
- Quantity l.81600E+03 GR IHPS Sample Number: 142522 *
- Geometry A lL marinelli sand 1
- - Analysis Library HP NATURAL *
- Operator: BILL DYNES *
- >>>>> A -1922924 PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.29 Calibration ll-JUN-2014 09:11 *
- Elapsed Real Time 0 00:03:00.36 Energy Offset -l.07429E-01 *
- Deadtime 0.0% Energy Slope 4.99821E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1. 00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 239.07 54 23 1. 59 478.50 472 15 24.7 2.91E+OO PB-212 1 295.04 17 13 1. 96 590.47 585 10 43.2 2.50E+OO PB-214 1 338.58 25 5 3.64 677.58 672 9 22.7 7.39E-01 1 352.00 34 6 2. 60 704.42 697 11 21.1 1.12E+OO PB-214 1 583.53 15 4 1. 68 1167.57 1163 8 34.0 1.93E-01 TL-208 1 609.39 21 2 1. 91 1219.29 1214 10 25.9 5.44E-01 BI-214 1 1460.69 57 0 2 .11 2921.85 2916 11 13.1 4.46E-01 K-40
Summary of Nuclide Activity Page : 2 Sample ID : 1013 Acquisition date ll-JUN-2014 10:51:47 Total number of lines in spectrum 7 Number of unidentified lines 0 Number of lines tentatively identified by NID 7 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y 1. 00 9.827E-06 9.827E-06 l.338E-06 13.62 A TL-208 3.05M 1. 65 1.421E-07 2.342E-07 0.807E-07 34.44 A PB-212 10.64H 1. 00 5.245E-07 5.258E-07 1.318E-07 25.07 A BI-214 19.90M 1. 08 3.845E-07 4.162E-07 1.093E-07 26. 25 A PB-214 26. SOM 1. 06 4.355E-07 4.620E-07 2.00SE-07 43.41 A Total Activity l .131E-05 1.14 7E-05 Grand Total Activity : l.131E-05 1.147E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 1013 Acquisition date : ll-JUN-2014 10:51:47 It Energy Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err %Eff Flags 1 338.58 25 5 3.64 677.58 672 9 1.39E-01 22.7 1.56E+OO T Flags: "T" = Tentatively associated
Interference Report Page : 4 Sample ID : 1013 Acquisition date 11-JON-2014 10:51:47 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 1013 Acquisition date ll-JUN-2014 10:51:47 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 57 10.67* 4.483E-01 9.827E-06 9.827E-06 13.62 TL-208 72.80 ------ 2.14 1.155E+OO ------ Line Not Found ------
74.97 ------ 3.60 1.239E+OO ------ Line Not Found ------
84.79 ----~- 1. 27 l.578E+OO ------ Line Not Found ------
252.45 ------ 0.80 1. 887E+OO ------ Line Not Found ------
277.28 ------ 6.80 1.783E+OO ------ Line Not Found ------
510.61 ------ 21. 60 1.121E+OO ------ Line Not Found ------
583.02 15 86.00* 9.946E-01 l.421E-07 2.342E-07 34.44 763.06 ------ 1. 64 7.714E-Ol ------ Line Not Found ------
860.30 ------ 12.00 6.870E-01 ------ Line Not Found ------
PB-212 74.81 ------ 10.50 1.233E+OO ------ Line Not Found ------
77 .11 ------ 17.70 l.319E+OO ------ Line Not Found ------
87.19 ------ 6.27 1.650E+OO ------ Line Not Found ------
90.13 ------ 1. 86 1.730E+OO ------ Line Not Found ------
115. 12 ------ 0.59 2.162E+OO ------ Line Not Found ------
238.58 54 43.60* l.946E+OO 5.245E-07 5.258E-07 25.07 300.03 ------ 3.34 1.694E+OO ------ Line Not Found ------
BI-214 76.86 ------ 0.58 1.310E+OO ------ Line Not Found ------
79.29 ------ 0.97 l.397E+OO ------ Line Not Found ------
609.31 21 46.10* 9.556E-01 3.845E-07 4.162E-07 26.25 665.44 ------ 1. 56 8.797E-01 ------ Line Not Found ------
768.35 ------ 4.88 7.663E-01 ------ Line Not Found ------
806.16 ------ 1. 23 7.315E-01 ------ Line Not Found ------
934.04 ------ 3.16 6.352E-01 ------ Line Not Found ------
1120.27 ------ 15.00 5.391E-01 ------ Line Not Found ------
1155. 18 ------ 1. 69 5.255E-01 ------ Line Not Found ------
1238 .11 ------ 5.92 4.976E-01 ------ Line Not Found ------
1280.95 ------ 1. 4 7 4.855E-Ol ------ Line Not Found ------
1377. 66 ------ 4.02 4.629E-01 ------ Line Not Found ------
1385. 30 ------ 0.78 4.614E-01 ------ Line Not Found ------
1401. 48 ------ 1. 39 4.583E-01 ------ Line Not Found ------
1407.97 ------ 2.48 4.571E-01 ------ Line Not Found ------
1509.22 ------ 2.19 4.415E-01 ------ Line Not Found ------
1583.22 ------ 0.72 4.336E-01 ------ Line Not Found ------
1661. 26 ------ 1.15 4.280E-01 ------ Line Not Found ------
1729.58 ------ 3.05 4.255E-01 ------ Line Not Found ------
1764.49 ------ 15.90 4.249E-01 ------ Line Not Found ------
1847.41 ------ 2.12 4.256E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 3.707E-01 ------ Line Not Found ------
74.81 ------ 6.52 1.233E+OO ------ Line Not Found ------
77 .11 ------ 11. 00 1.319E+OO ------ 'Line Not Found ------
87.19 ------ 3.88 1.650E+OO ------ Line Not Found ------
90.13 ------ 1.15 1.730E+OO ------ Line Not Found ------
241. 92 ------ 7.46 1.933E+OO ------ Line Not Found ------
258.94 ------ 0.55 l.859E+OO ------ Line Not Found ------
295.09 17 19.20* 1.713E+OO 4.355E-07 4.620E-07 43.41 351. 87 34 37.10 l.514E+OO 5.067E-07 5.375E-07 21. 59 785.83 ------ 1. 09 7.498E-01 ------ Line Not Found ------
839.00 ------ 0.59 7.038E-01 ------ Line Not Found ------
Nuclide Line Activity Report (continued) Page : 6 Sample ID : 1013 Acquisition date ll-JUN-2014 10:51:47 Flag: "*" Keyline
Minimum Detectable Activity Report Page : 7 Sample ID : 1013 Acquisition date 11-JUN-2014 10:51:47 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 2. 477.61 6.2063E-07 MN-54 3. 834.83 1. 2560E-07 MN-56 3. 846.81 l.3004E-07 C0-57 14. 122.06 8.6879E-08 C0-58 2. 810.79 l.0032E-07 C0-60 0. 1332. 50 4.7212E-08 SB-124 3. 602.73 9.0270E-08 SB-125 6. 427.88 2.9730E-07 CS-134 2. 604. 71 8.1541E-08 CS-137 1. 661. 66 6.8019E-08