Health Physics Sample Records Sample ID:
142448 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
1405288D 18 STAR 18-20 Dirt Sample
~mmon Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID:
Contact:
COOPER, TERRY L Survey No:
Reference ID:
Accounting Subcode:
Unknown Mat:
NO Comments: Count to MDA Reviewed: DYNES, WILLIAM J Date: 05/30/14 08:58 Comments:
I OrigJ.!!J Mat. SizeNolume:
2129 ml Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00
==
Description:==
STAR 18 SOIL SAMPLE Collection Sample Tech:
DYNES, WILLIAM J Tritium Req:
No Instructions:
Comments:
COUNT TO MDA
[.kLSS_SJ Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
No I Location Unit: NON-UNIT RE Stored By:,
Sample Loe:
Other:
Material Loe:
06/18/201411:54 Area: MS Sample Date: 05/29/14 08:02 Sample SizeNolume: 2129 GRAMS Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
~
Elev: 100 Room:
Depth: 3" (in.)
Equip ID:
Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of3
Sample ID:
142448 Type: RLSSS Type Detail: SAND
==
Description:==
140528BD 18 STAR 18-20 Dirt Sample I Analysis I Geometry B_ 1 L_marinelli_sand_
MCA ID Quant.
Units 30296 2129GR Method lsotoe~ Mode Activity Activity Uncert.
LLD/MDA 0
K-40 NT 0
TL-208 NT 0
PB-212 NT 0
Bl-214 NT 0
PB-214 NT 0
RA-226 NT 0
U-235 NT 0
BE-7 AP 0
MN-56 AP 0
C0-57 AP 0
C0-58 AP 0
C0-60 AP 0
SB-124 AP 0
SB-125 FP 0
CS-134 FP 0
0.0 0001311
1.57E-6 5.339E-7 9.12E-8 7.192E-7 1.677E-7 8.644E-7 1.268E-7 9.076E-7 2.203E-7 3.996E-6 1.464E-6 2.473E-7 9.06E-8 8.7061E-7 1.1135E-7 1.5116E-7 1.0675E-7 8.4656E-8 3.965E-8 8.3775E-8 3.1326E-7 9.6174E-8 9.924E-8 r
r Iv Iv" IV" Iv Jv Iv ji7 ji7 Jv Iv Health Physics Sample Records Status: APPROVED FP/AP Lab Analysis~}'
.000 PARK, MICHAEL C
%Abund.
Atom. No.
Comments 64.455%
40 2.611%
208 3.517%
212 4.227%
214 4.438%
214 19.542%
226 1.209%
235 0.000%
7 0.000%
54 0.000%
56 0.000%
57 0.000%
58 0.000%
60 0.000%
124 0.000%
125 0.000%
134 0.000%
137 Re-Analize:
No Lie Rad Mat Present:
No Reviewed: COOPER, TERRY L HP Notified Name:
Hp Eng Rvw Reqd:
Yes Rad Mat Present:
Yes Comments:
06/18/201411:54 Rasterized: r Date Mod ID Mod Date 06/02/14 09:58 Mod Id Mod Date Date: 06/10/1410:18 Page 2 of 3
Sample ID:
142448 Type: RLSSS Type Detail: SAND
==
Description:==
140528BD 18 STAR 18-20 Dirt Sample I Review/Approve I Reviewed: COOPER, TERRY L Health Physics Sample Records Status: APPROVED HP Review Date: 06/10/14 10:19 Comments: U-235 likely mis-Id from Ra-226 energy peak; peak at 429 keV is not due to plant-produced nuclide Disposition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/18/2014 11 :54 Disposition Result: Sample contains only natural isotopes Final Ap_p_roval Date: 06/10/1410:19 Rasterized:
Page 3 of 3
SONGS HEALTH PHYSICS REPORT 2-JUN-2014 09:54
- Title
>>>>> SAMPLE PARAMETERS<<<<<
140528BD 18 STAR 18-20 DIRT SAMPLE
- ID 30296 Acquisition date: 2-JUN-2014 09:51:46. *
- Start Time:
- Stop Time:
- Quantity
- Geometry 2-JUN-2014 09:51:00.
2-JUN-2014 09:51:00.
Counting System 2.12900E+03 GR IHPS Sample Number:
B lL marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142448 HP NATURAL
>>>>> B #42-TP11663A PARAMETERS<<<<<
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.40 0 00:03:00.46 0.0%
1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 1-JUN-2014 20:28:
-5.64750E-02 4.99765E-Ol
- 1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1
77.67 64 101 3.50 155.53 148 16 38.3 4.45E+OO BI-214 PB-212 PB-214 1
186.28 38 30
238.69 80 79
- 1. 39 477.71 474 11 23.3 4.21E+OO PB-212 1
295.47 37 9
2.15 591. 32 587 12 24.3 9.90E-01 PB-214 1
352.36 42 20 2.09 705.16 698 13 26.2 3.90E+OO PB-214 1
429.43 13 10
- 1. 78 859.37 852 14 58.6 8.57E-01 1
582.83 37 0
2.21 1166.32 1161 12 17.1 4.63E-01 TL-208 1
609.06 46 0
- 1. 98 1218.79 1212 11 14.7 4.18E-01 BI-214 1
1460.28 84 3
- 1. 99 2922.04 2916 12 11. 9 7.67E-01 K-40
Summary of Nuclide Activity Sample ID : 30296 Total number of lines in spectrum Number of unidentified lines Page :
2 Acquisition date 2-JUN-2014 09:51:46 Number of lines tentatively identified by NID 9
1 8
88.89%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error Flags K-40 1.28E+09Y
- 1. 00 1.318E-05
- 1. 318E-05 0.157E-05
- 11. 88 A
TL-208 3.05M
- 1. 64 3.250E-07 5.339E-07 0.912E-07 17.08 A
PB-212 10.64H
- 1. 00 7.174E-07 7.192E-07 l.677E-07 23.32 A
BI-214 19.90M
- 1. 08 7.990E-07 8.644E-07 l.268E-07 14.66 A
PB-214
- 26. SOM
- 1. 06 8.560E-07 9.076E-07 2.203E-07 24.27 A
RA-226 1600.00Y
- 1. 00 3.996E-06 3.996E-06 1.464E-06 36.64 A
U-235 7.04E+08Y
- 1. 00 2.473E-07 2.473E-07 0.906E-07 36.64 A
Total Activity 2.012E-05 2.045E-05 Grand Total Activity :
2.012E-05 2.045E-05 Flags: "K" Keyline not found "M"
Manually accepted "E"
Manually edited "A"
Nuclide specific abn. limit
Unidentified Energy Lines Sample ID : 30296 Page :
3 Acquisition date : 2-JUN-2014 09:51:46 It 1
Energy 429.43 Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err
%Eff Flags 13 10 1.78 859.37 852 14 7.25E-02 58.6 1.20E+OO Flags: "T" = Tentatively associated
Interference Report Sample ID : 30296 No interference correction performed Acquisition date Page :
4 2-JUN-2014 09:51:46
Nuclide Line Activity Report Page :
5 Sample ID : 30296 Acquisition date 2-JUN-2014 09:51:46 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 84 10.67*
4.212E-01 1.318E-05 1.318E-05
- 11. 88 TL-208 72.80 ------
2.14 l.070E+OO Line Not Found ------
74.97 ------
3.60 1.156E+OO Line Not Found ------
84.79 ------
- 1. 27 1.506E+OO Line Not Found ------
252.45 ------
0.80 1.745E+OO Line Not Found ------
277.28 6.80 1.645E+OO Line Not Found ------
510.61 ------
- 21. 60 l.035E+OO Line Not Found ------
583.02 37 86.00*
9.202E-01 3.250E-07 5.339E-07 17.08 763.06 ------
- 1. 64 7.126E-01 Line Not Found ------
860.30 ------
12.00 6.341.E-Ol Line Not Found ------
PB-212 74.81 ------
10.50 1.150E+OO Line Not Found ------
77.11 64 17.70 1.260E+OO 2.015E-06 2.020E-06 38.26 87.19 ------
6.27 1.579E+OO Line Not Found ------
90.13 ------
- 1. 86 l.662E+OO Line Not Found ------
115. 12 0.59 2.085E+OO Line Not Found ------
238.58 80 43.60*
1.804E+OO 7.174E-07 7.192E-07 23.32 300.03 ------
3.34 1.562E+OO Line Not Found ------
BI-214 76.86 64 0.58 l.260E+OO 6.150E-05 6.653E-05 38.26 79.29 ------
0.97 1.320E+OO Line Not Found ------
609.31 46 46.10*
8.836E-01 7.990E-07 8.644E-07 14.66 665.44
- 1. 56 8.131E-01 ------
Line Not Found ------
768.35 ------
4.88 7.078E-01 ------
Line Not Found ------
806.16 ------
- 1. 23 6.754E-01 ------
Line Not Found ------
934.04 3.16 5.861.E-Ol ------
Line Not Found ------
1120.?.7 ------
15.00 4.982E-01 ------
Line Not Found ------
1155.18
- 1. 69 4.860E-01 ------
Line Not Found ------
1238.11 ------
5.92 4.615E-01 ------
Line Not Found ------
1280.95 ------
- 1. 4 7 4.51.0E-01 Line Not Found ------
1377.66 ------
4.02 4.323E-01 ------
Line Not Found ------
1385.30 ------
0.78
- 4. 311E-01 ------
Line Not Found ------
1401.48 ------
- 1. 39 4.287E-01 ------
Line Not Found ------
1407.97 ------
4.48 4.277E-01 ------
Line Not Found ------
1509.22 ------
2.19 4.165E-01 ------
Line Not Found ------
1583.22 ------
0.72 4.120E-01 ------
Line Not Found ------
1661. 26 ------
1.15 4.103E-01 ------
Line Not Found ------
1729.58 ------
3.05 4.114E-01 ------
Line Not Found ------
1764.49 ------
15.90 4.128E-01 ------
Line Not Found ------
1847.41 ------
2.12 4.187E-01 ------
Line Not Found ------
PB-214 53.17 ------
1.10 2.929E-01 ------
Line Not Found ------
74.81 6.52 1.150E+OO Line Not Found ------
77.11 64
- 11. 00 l.260E+OO 3.243E-06 3.438E-06 38.26 87.19 ------
3.88 l.579E+OO Line Not Found ------
90.13 1.15 l.662E+OO Line Not Found ------
241.92 7.46
- 1. 7 90E+OO Line Not Found ------
258.94 0.55
- 1. 718E+OO Line Not Found ------
295.09 37 19.20*
1.578E+OO 8.560E-07 9.076E-07 24.27 351.87 42 37.10 1.394E+OO 5.747E-07 6.093E-07 26.19 785.83
- 1. 09 6.925E-01 Line Not Found ------
839.00 ------
0.59 6.497E-01 Line Not Found ------
Nuclide Line Activity Report (continued)
Page :
6 Sample ID : 30296 Acquisition date 2-JUN-2014 09:51:46 Nuclide Type: natural Nuclide RA-226 U-235 Flag: "*"
Energy
- 81. 07 186.11
- 89. 96 93.35 105.36 109.18 143.79 163.38 185.74 194. 96 202.13 205.33 Keyline Area 38 38
%Abn
%Eff 0.18 1.383E+OO 3.28*
2.042E+OO 3.36 l.657E+OO 5.50
- 1. 743E+OO
- 1. 98
- 1. 973E+OO
- 1. 50 2.024E+OO 10.50 2.177E+OO 4.70 2.133E+OO 53.00*
2.042E+OO 0.59 2.003E+OO
- 1. 00 1.970E+OO 4.70
- 1. 956E+OO Uncorrected Decay Corr 1-Sigma uCi/GR uCi/GR
%Error Line Not Found ------
3.996E-06
- 3. 996E-06 36.64 Line Not Found ------
Line Not Found ------
Line Not Found ------
Line Not Found ------
Line Not Found ------
Line Not Found ------
2.473E-07 2.473E-07 36.64 Line Not Found ------
Line Not Found ------
Line Not Found ------
Minimum Detectable Activity Report Page :
7 Sample ID 30296 Acquisition date 2-JUN-2014 09:51:46 Bckgnd Energy MDA Nuclide Sum (keV)
(uCi/GR)
BE-7
- 6.
477.61 8.7061E-07 MN-54
- 3.
834.83
- 1. 1135E-07 MN-56
- 5.
846.81
- 1. 5116E-07 C0-57
- 29.
122.06 1.0675E-07 C0-58
- 1.
810.79 8.4656E-08 C0-60
- o.
1173.24 3.9650E-08 SB-124
- 3.
602.73 8.3775E-08 SB-125
- 8.
427.88 3.1326E-07 CS-134
- 4.
604. 71 9.6174E-08 CS-137
- 2.
661. 66 9.9240E-08