ML20034D979
Text
Health Physics Sample Records Sample ID: 142444 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140528BD 14 STAR 14-20 Dirt Sample Common Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 05/30/14 08:14 Comments:
I Origin Mat. SizeNolume: 1875 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
STAR 14 SOIL SAMPLE I Collection I Sample Tech: DYNES, WILLIAM J Sample Date: 05/29/14 07:32 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 1875 GRAMS Instructions:
Comments: COUNT TO MDA I R1..sss 1 Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~
ILocation Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: 3" (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other:
Material Loe:
06/18/2014 11 :53 Page 1 of 3
Health Physics Sample Records Sample ID: 142444 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140528BD 14 STAR 14-20 Dirt Sample
!Analysis I Geometry MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date C_1L_marinelli_sand_ 30284 1875GR .000 HENDERSON, JOE C 05/30/1413:28 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.000014811.41E-6 6.806% 40 0 TL-208 NT 5.339E-7 8.42E-8 r 0.245% 208 0 PB-212 NT 9.109E-7 1.208E-7 r 0.419% 212 0 Bl-214 NT 7.262E-7 1.293E-7 r 0.334% 214 0 PB-214 NT 6.701E-7 2.376E-7 r 0.308% 214 0 RN-222 NT 0.0001961 0.0000521 r 90.120% 222 0 RA-226 NT 2.897E-6 1.209E-6 r 1.331% 226 0 AC-228 NT 7.712E-7 2.023E-7 r 0.354% 228 0 U-235 NT 1.793E-7 7.48E-8 r 0.082% 235 0 BE-7 AP 7.3754E-7 Iv 0.000% 7 0 MN-54 AP 7.3495E-8 Iv' 0.000% 54 0 MN-56 AP 1.0017E-7 Iv 0.000% 56 0 C0-57 AP 1.0125E-7 Iv' 0.000% 57 0 C0-58 AP 1.1466E-7 Iv 0.000% 58 0 C0-60 AP 1.2286E-7 Iv 0.000% 60 0 SB-124 AP 9.3833E-8 Iv 0.000% 124 0 SB-125 FP 2.1966E-7 Iv 0.000% 125 0 CS-134 FP 8.0324E-8 Iv 0.000% 134 0 CS-137 FP 1.3414E-7 Iv 0.000% 137 I .A.na1ysisReview I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/1410:03 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/18/201411:53 Page 2 of 3
Health Physics Sample Records Sample ID: 142444 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140528BD 14 STAR 14-20 Dirt Sample I Review/ApproveJ HP Review Reviewed: COOPER, TERRY L Date: 06/10/14 10:04 Comments: U-235 likely mis-lD'd from Ac-228 and Ra-226 energy peaks Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/10/14 10:04 Comments:
06/18/201411:53 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT 30-MAY-2014 13:16 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 140528BD 14 STAR 14-20 DIRT SAMrLE *
- ID 30284 Acquisition date: 30-MAY-2014 13:13:36 *
- Start Time: 30-MAY-2014 13:13:00 *
- Stop Time: 30-MAY-2014 13:13:00 Counting System U2GSP *
- Quantity l.87500E+03 GR IHPS Sample Number: 142444 *
- Geometry C 11 marinelli sand 1 Analysis Library HP NATURAL *
- Operator: JOE HENDERSON *
- >>>>> C #41-TP11750A PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.41 Calibration 29-MAY-2014 21:45 *
- Elapsed Real Time 0 00:03:00.48 Energy Offset -l .13380E-01 *
- Deadtime 0.0% Energy Slope 4.99622E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1.00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 5 74.34 70 24 1. 43 149.02 144 19 18.5 2.69E+OO PB-212 PB-214 TL-208 5 77.33 62 21 1. 43 155.01 144 19 21. 0 BI-214 PB-212 PB-214 1 93.18 46 42 1. 78 186.73 182 9 28.6 3.97E+OO AC-228 U-235 1 185.85 27 34 1. 48 372.20 368 8 41. 7 1.94E+OO U-235 RA-226 1 238.51 102 24 1.15 477.58 474 7 13. 3 5.67E+OO PB-212 1 295.28 28 16 1. 31 591.19 586 11 35.5 8.75E-01 PB-214 1 338.19 25 5 1. 50 677.08 670 11 27.7 8.97E-01 AC-228 1 351. 80 63 13 1. 53 704.31 700 9 16.3 5.47E-01 PB-214 1 510.54 22 5 2.50 1021.97 1018 9 26. 6 8.36E-01 RN-222 TL-208 1 582.98 42 0 1. 97 1166.93 1162 10 15.8 8.79E-01 TL-208 1 609.27 43 5 1. 91 1219.53 1214 10 17.8 5.09E-01 BI-214 1 910. 96 21 4 2.08 1823.18 1819 8 26.2 4.05E-01 AC-228 1 1460.72 110 0 2.04 2923.02 2918 10 9.5 4.57E-01 K-40
Summary of Nuclide Activity Page : 2 Sample ID : 30284 Acquisition date 30-MAY-2014 13:13:36 Total number of lines in spectrum 13 Number of unidentified lines 0 Number of lines tentatively identified by NID 13 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y 1. 00 1.481E-05 1. 481E-05 0.141E-05 9.50 A TL-208 3.05M 1. 58 3.375E-07 5.339E-07 0.842E-07 15.77 A PB-212 10.64H 1. 00 9.088E-07 9.109E-07 1.208E-07 13.27 A BI-214 19.90M 1. 08 6.752E-07 7.262E-07 1.293E-07 17.81 A PB-214 26.80M 1. 06 6.348E-07 6.701E-07 2.376E-07 35.45 A RN-222 3.83D 1. 00 1. 960E-04 l.961E-04 0.521E-04 26.59 A RA-226 1600.00Y 1. 00 2.897E-06 2.897E-06 1.209E-06 41. 73 A AC-228 6.13H 1. 00 7.682E-07 7.712E-07 2.023E-07 26.23 A U-235 7.04E+08Y 1. 00 1. 7 93E-07 1.793E-07 0.748E-07 41. 73 A Total Activity 2.172E-04 2.176E-04 Grand Total Activity : 2.172E-04 2.176E-04 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30284 Acquisition date 30-MAY-2014 13:13:36 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30284 Acquisition date 30-MAY-2014 13:13:36 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30284 Acquisition date 30-MAY-2014 13:13:36 Nuclide Type: natural Uncorrected Decay Corr l-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 110 10.67* 5.560E-Ol l.481E-05 l. 48lE-05 9.50 TL-208 72.80 ------ 2.14 l.486E+OO ------ Line Not Found ------
74.97 70 3.60 l.551E+OO l.006E-05 l.592E-05 18.47 84.79 ------ l. 27 l.917E+OO ------ Line Not Found ------
252.45 ------ 0.80 2.004E+OO ------ Line Not Found ------
277.28 ------ 6.80 l. 9l 7E+OO ------ Line Not Found ------
510.61 22 21. 60 l. 298E+OO 6.353E-07 l.005E-06 26.59 583.02 42 86.00* l. l58E+OO 3.375E-07 5.339E-07 15.77 763.06 ------ l. 64 8.934E-Ol ------ Line Not Found ------
860.30 ------ 12.00 7.922E-Ol ------ Line Not Found ------
PB-212 74.81 70 10.50 l. 551E+OO 3.450E-06 3.458E-06 18.47 77 .11 62 17.70 1.669E+OO l.684E-06 l. 688E-06 21. 04 87.19 ------ 6.27 1.983E+OO ------ Line Not Found ------
90.13 ------ l. 86 2.055E+OO ------ Line Not Found ------
115 .12 ------ 0.59 2.376E+OO ------ Line Not Found ------
238.58 102 43.60* 2.055E+OO 9.088E-07 9.l09E-07 13.27 300.03 ------ 3.34 l.843E+OO ------ Line Not Found ------
BI-214 76.86 62 0.58 l.669E+OO 5.l39E-05 5.527E-05 21. 04 79.29 ------ 0.97 l.741E+OO ------ Line Not Found ------
609.31 43 46.10* l. 112E+OO 6.752E-07 7.262E-07 17.81 665.44 ------ l. 56 1.023E+OO ------ Line Not Found ------
768.35 ------ 4.88 8.873E-Ol ------ Line Not Found ------
806.16 ------ l. 23 8.454E-Ol ------ Line Not Found ------
934.04 ------ 3.16 7.3l0E-Ol ------ Line Not Found ------
1120. 27 ------ 15.00 6.242E-01 ------ Line Not Found ------
1155. 18 ------ l. 69 6.105E-Ol ------ Line Not Found ------
1238.11 ------ 5.92 5.846E-Ol ------ Line Not Found ------
1280.95 ------ l. 4 7 5.747E-01 ------ Line Not Found ------
1377. 66 ------ 4.02 5.602E-01 ------ Line Not Found ------
1385.30 ------ 0.78 5.595E-Ol ------ Line Not Found ------
1401.48 ------ l. 39 5.583E-Ol ------ Line Not Found ------
1407.97 ------ 2.48 5.578E-Ol ------ Line Not Found ------
1509.22 ------ 2.19 5.568E-Ol ------ Line Not Found ------
1583.22 ------ 0. 72 5.628E-Ol ------ Line Not Found ------
1661. 26 l.15 5.753E-Ol ------ Line Not Found ------
1729.58 ------ 3.05 5.918E-Ol ------ Line Not Found ------
1764.49 ------ 15.90 6.023E-01 ------ Line Not Found ------
1847.41 ------ 2.12 6.331E-Ol ------ Line Not Found ------
PB-214 53.17 ------ l.10 5.203E-Ol ------ Line Not Found ------
74.81 70 6.52 l.551E+OO 5.556E-06 5.865E-06 18.47 77 .11 62 11. 00 l.669E+OO 2.709E-06 2.860E-06 21. 04 87.19 ------ 3.88 1. 983E+OO ------ Line Not Found ------
90.13 ------ l.15 2.055E+OO ------ Line Not Found ------
241. 92 ------ 7.46 2.043E+OO ------ Line Not Found ------
258.94 ------ 0.55 l.981E+OO ------ Line Not Found ------
295.09 28 19.20* 1.858E+OO 6.348E-07 6.701E-07 35.45 351. 87 63 37.10 l.686E+OO 8.029E-07 8.477E-07 16.33 785.83 ------ 1. 09 8.674E-Ol ------ Line Not Found ------
839.00 ------ 0.59 8.122E-Ol ------ Line Not Found ------
Nuclide Line Activity Report ( continued) Page : 6 Sample ID : 30284 Acquisition date 30-MAY-2014 13:13:36 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error RN-222 510.00 22 0.07* 1.298E+OO 1. 960E-04 l.961E-04 26.59 RA-226 81. 07 ------ 0.18 l.802E+OO Line Not Found ------
186.11 27 3.28* 2.262E+OO 2. 897E--06 2.897E-06 41. 73 AC-228 89.96 ------ 3.40 2.051E+OO Line Not Found ------
93.35 46 5.60 2.120E+OO 3.106E-06 3 .118E-06 28.60 99.55 ------ 1. 30 2.229E+OO ------ Line Not Found ------
105.36 ------ 2.00 2.301E+OO ------ Line Not Found ------
108.99 ------ 0.67 2.335E+OO ------- Line Not Found ------
12 9. 03 ------ 2.90 2.414E+OO ------ Line Not Found ------
153.89 ------ 0.84 2.377E+OO ------ Line Not Found ------
209.39 ------ 4.10 2.168E+OO ------ Line Not Found ------
216.24 ------ 0.80 2.141E+OO ------ Line Not Found ------
270.26 ------ 3.80 1.941E+OO ------ Line Not Found ------
328.07 ------ 3.50 1. 756E+OO ------ Line Not Found ------
338.42 25 12.40 1.726E+OO 9.431E-07 9.469E-07 27.75 340.94 ------ 0.52 1. 718E+OO Line Not Found ------
409.62 ------ 2.20 1.531E+OO Line Not Found ------
463.10 ------ 4. 60 1.401E+OO ------ Line Not Found ------
562.65 ------ 1. 01 1.195E+OO Line Not Found ------
581.52 ------ 3.00 1.160E+OO ------ Line Not Found ------
726.63 ------ 0.87 9.382E-01 ------ Line Not Found ------
755.28 ------ 1. 32 9.027E-01 ------ Line Not Found ------
772. 28 ------ 1. 09 8.827E-Ol ------ Line Not Found ------
782.12 ------ 0.59 8.716E-01 ------ Line Not Found ------
794.79 ------ 4.60 8.576E-01 ------ Line Not Found ------
830.59 ------ 0.63 8.205E-01 ------ Line Not Found ------
835.60 ------ 1. 71 8.155E-01 ------ Line Not Found ------
840.44 ------ 0.94 8.108E-01 ------ Line Not Found ------
904.29 ------ 0.89 7.542E-01 ------ Line Not Found ------
911.16 21 29.00* 7.488E-01 7.682E-07 7, 712E-07 26.23 964. 64 ------ 5.80 7.091E-01 Line Not Found ------
968.97 ------ 17.40 7.061E-01 Line Not Found ------
1246.60 ------ 0.57 5.825E-01 ------ Line Not Found ------
1459.19 ------ 1. 06 5.560E-01 ------ Line Not Found ------
1496.00 ------ 1. 05 5.563E-01 ------ Line Not Found ------
1501. 44 ------ 0.58 5.565E-01 ------ Line Not Found ------
1580.30 ------ 0.71 5.624E-01 ------ Line Not Found ------
1588.23 ------ 3.60 5.634E-01 ------ Line Not Found ------
1630.47 ------ 1. 95 5. 696E-01 ------ Line Not Found ------
1638.10 ------ 0.54 5.709E-01 ------ Line Not Found ------
U-235 89. 96 ------ 3.36 2.051E+OO ------ Line Not Found ------
93.35 46 5.50 2.120E+OO 3.162E-06 3.162E-06 28.60 105.36 ------ 1. 98 2.301E+OO Line Not Found ------
109.18 ------ 1. 50 2.336E+OO ------ Line Not Found ------
143.79 ------ 10.50 2.402E+OO ------ Line Not Found ------
163.38 ------ 4.70 2.347E+OO ------ Line Not Found ------
185.74 27 53.00* 2.262E+OO 1. 7 93E-07 1. 793E-07 41.73 194.96 ------ 0.59 2.226E+OO ------ Line Not Found ------
202.13 ------ 1. 00 2.197E+OO ------ Line Not Found ------
Nuclide Line Activity Report (continued) Page : 7 Sample ID : 30284 Acquisition date 30-MAY-2014 13:13:36 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error 205.33 4.70 2.184E+OO Line Not Found Flag: "*" Keyline
Minimum Detectable Activity Report Page : 8 Sample ID 30284 Acquisition date 30-MAY-2014 13:13:36 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 5. 477.61 7.3754E-07 MN-54 1. 834.83 7.3495E-08 MN-56 2. 846.81 1.0017E-07 C0-57 25. 122.06 1.0125E-07 C0-58 4. 810.79 1.1466E-07 C0-60 2. 1173.24 1. 2286E-07 SB-124 5. 602.73 9.3833E-08 SB-125 4. 427.88 2 .1966E-07 CS-134 1. 795.87 8.0324E-08 CS-137 7. 661.66 l.3414E-07