ML19312D860

From kanterella
Jump to navigation Jump to search
Proposed Tech Spec Pages Re Change Request 61 Addressing Cycle 3 Operation of Facility at Present Licensed Core Power Level
ML19312D860
Person / Time
Site: Crystal River 
Issue date: 04/30/1980
From:
FLORIDA POWER CORP.
To:
Shared Package
ML19312D858 List:
References
NUDOCS 8005050268
Download: ML19312D860 (35)


Text

__

3 005 0 50 7_(,'$h TECHNICAL SPECIFICATION CHANGE REQUEST NO. 61 (APPENDIX A)

Page Replacement

()

Delete and insert the pages in Appendix A of Operating License DPR-72 as indicated below:

DELETE INSERT III III 2-3 2-3 2-5 2-5 2-7 2-7 l

B 2-1 B 2-1 B-2-5 B 2-5 8 2-6 B 2-6 B 2-8 8 2-8 3/41-1 3/41-1 3/4 1-2a 3/4 1-2a 3/4 1-2b 3/4 1-7 3/4 1-7 3/4 1-8 3/41-8 3/4 1-10 3/4 1-10 3/4 1-10a 3/4 1-10a 3/4 1-13 3/4 1-13 3/4 1-16 3/4 1-16 3/4 1-17 3/4 1-17 3/4 1-27 3/4 1-27 3/4 1-28 3/4 1-28 3/4 1-29 3/4 1-29 3/4 1-30 3/4 1-30 3/4 1-38 3/4 1-38 3/4 1-39 3/4 1-39 3/4 2-2 3/42-2 3/42-3 3/42-3 3/4 2-11 3/4 2-11 3/4 2-13 3/4 2-13 3/4 4-1 3/4 4-1 3/4 10-4 3/4 10-4 B3/4 1-1 B3/4 1-1 B3/4 1-2 B3/4 1-2 B3/4 1-3 B3/4 1-3 I

l

V Proposed Change A portion of these changes address the current reactor refueling for Cycle 3.

These reload changes are supported in BAW-1607, Revision 1, Crystal River Unit 3 - Cycle 3 Reload Report.

The remainder of the changes address increasing the Shutdown Margin in Modes 4 and 5 from

>2.2% A k/k to >3.0 Ak/k.

These changes include changing: 1) the Reactor Core Safety Limit for Reactor Thermal Power and Axial Power Imbalance and associated Bases; 2) the Limiting Safety System Settings and associated Bases; 3) the Regula-ting and Axial Power Shaping Rod Group insertion limits; 4) the figures that specify the power level cutoff for Xenon reactivity; 5) the Axial Power Imbalance Envelopes; 6) the Quadrant Power Tilt Limits; and 7) the DNB Margin Limits; 8) the Shutdown Margin requirements for Modes 4 and 5.

Reason for Proposed Change Crystal River Unit 3 will operate in Cycle 3 with 52 fresh fuel assem-blies.

As stated in BAW-1607, Revision 1, Crystal River Unit 3 -

Cycle 3 Reload Report, certain Technical Specifications require revision as a result of the Cycle 3 reload. The analyses sumarized in BAW-1607, Revision 1, accounted for the Cycle 3 reload, the addition of the reac-tor coolant pump power monitors, and the potential increase in licensed rated thermal power from 2452 MWt to 2544 MWt, As a result of the pro-posed operation of Cycle 3 at the present licensed core power level, the proposed specifications which were determined for 2544 MWt will be con-servative for operation at 2452 MWt.

a.

Pages 2-3, 2-5, The flux / Aflux envelopes, flux / flow trips, 2-7, B2-1, B2-5, regulating rod group insertion limits, axial B2-6, B2-8, 3/4 power shaping rod group insertion limits, and 1-27, 3/4 1-28, axial power imbalance envelopes reflect re-3/41-29,3/41-30, vised nuclear parameters as a result of the 3/41-38,3/41-39, Cycle 3 reload.

3/4 2-2, 3/4 2-3, 3/44-1:

b.

Page 3/4 2-11:

Tilt limits were reduced to reflect increased detector depletion.

c.

Page 3/4 2-13:

Flow rates were revised to reflect the values used in the analyses.

The proposed changes to increase the Shutdown Margin requirements in Modes 4 and 5 are made to insure that a deboration incident resulting from the inadvertent injection of sodium hydroxide will not result in criticality.

d.

Pages 3/4 1-1, Shutdown Margin requirements are increased to 3/4 1-2a, 3/4 1-2b, 3.0%.

3/4 1-7, 3/4 1-8, 3/4 1-10, 3/4 1-10a,

3/41-13,3/41-16, 3/41-17,3/410-4, B3/4 1-1, B3/4 1-2, B3/4 1-3 Safety Analysis of Proposed Change The licensing considerations for operation of Crysta.1 Ricer Unit 3 with the Cycle 3 reload are described in BAW-1607, Revision 1, Crystal River Unit 3 - Cycle 3 Reload Report.

These proposed changes will bring the Technical Specifications into agreement with the applicable portions of BAW-1607, Revision 1, as amended by the reanalysis for continuation of operation at 2452 MWt without Reactor Coolant Pump Power Monitors.

The review, of the Technical Specifications ensures that the Final Ac-ceptance Criteria ECCS limits will not be exceeded nor will the thermal design criteria be violated.

The increase in the Shutdown Margin requirements in Modes 4 and 5 will ensure that a deboration incident resulting from the inadvertent injec-tion of sodium hydroxide will not result in criticality.

TSCRN61A(08) l

INDEX LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS SECTION PAGE 3/4.0 APPLICABILITY...........................................

3/4 0-1 3/4.1 REACTIVITY CONTROL SYSTEMS 3/4.1.1 B0 RATION CONTROL Shutdown Margin - 0perating..........................

3/4 1-1 Shutdown Margin - Shutdown...........................

3/4 1-2a Boron Dilution......................................

3/4 1-3 Moderator Temperature Coef ficient....................

3/4 1-4 Minimum Temperature for Cri ticali ty..................

3/4 1-5 3/4.1.2 BORATION SYSTEMS Flow Paths - Shutdown................................

3/4 1-6 Flow Paths - 0perating...............................

3/4 1-7 Makeup Pump - Shutdown...............................

3/4 1-9 Makeup Pumps - 0perating.............................

3/4 1-10 Decay Heat Removal Pump - Shutdown...................

3/4 1-11 Boric Acid Pump - Shutdown...........................

3/4 1-12 Boric Acid Pumps - Operating.........................

3/4 1-13 Borated Water Sources - Shutdown.....................

3/4 1-14 Borated Water Sources - Operati ng....................

3/4 1-16 3/4.1.3 M0VABLE CONTROL ASSEMBLIES Group Height - Safety and Regulating Rod Groups......

3/4 1-18 Group Height - Axial Power Shaping Rod Group.........

3/4 1-20 Posi tion Indicator Channel s..........................

3/4 1-21 Rod Drop Time........................................

3/4 1-23 Safety Rod Insertion Limit...........................

3/4 1-24 Regulating Rod Insertion Limits......................

3/4 1-25 Rod Program..........................................

3/4 1-33 Xenon Reactivity.....................................

3/4 1-36 Axial Power Shapi ng Rod Insertion Limi ts.............

3/4 1-37 CRYSTAL RIVER - UNIT 3 III

j 120 t

(-34.72,112)

(20.16,112)

.,,, g g g

. (-40,107).

ACCEPlABLE 4.--

- 100 439.,100)

PUMP OPERATION l

90

.i

( '34.72,84.'18)

(20.16,84.18) 80

(-40~7971871

{~

~ ~ ~ ~

~

~~

l i

ACCEPTABLE 3&4 70 1 (39,72.18)

PUMP OPEPATION i

i

.;.. 60 iE i

.(

.... }

.. 50

.E I;

.. 4 0.

i=

i i3 i

I-30 o

20

._}

d' I

I I

.w

..... _... _.._ i. _..._.. _ j...._..

2- - 10 ;..

u q

=:

c

-60

-50

-40

-30

-20

-10 0

+10

+20

+30

+40

+50

+60 l

.I f

. 4.._....j 4

i i

i AXIAL POWER IMBALANCE, %

FIGURE 2.1-2 REACTOR CORE SAFETY LIMIT CRYSTAL RIVER - UNIT 3 2-3

TABLE 2.2-1 REACTOR PROTECTION SYSTEM INSTRUMENTATION TRIP SETPOINTS 9a g;

FUNCTIONAL UNIT TRIP SETPOINT ALLOWABLE VALUES 2'

1.

Manual Reactor Trip Not Applicable Not Applicable

]'

2.

Nuclear Overpower

<105.5% of RATED THERMAL POWER

<105.5% of RATED THERMAL POWER with four pumps operating with four pumps operating E

q

.177.68% of RATED THERMAL POWER

.577.68% of RATED THERMAL POWER with three pumps operating with three pumps operating u,

3.

RCS Outlet Temperature-High

<619 F

<619 F 4.

Nuclear Overpower Based on Trip Setpoint not to exceed the Allowable Values not to exceed RCSFlowgnqAXIALPOWER limit line of Figure 2.2-1 the limit line of Figure 2.2-1.

IMBALANCEll i 5.

RCS Pressure-Low (1) 21800 psig 21800 psig

{'

6.

RCf Pressure-High f,2300 psig f,2300 psig 7.

T CS Pressure-Variable Low (1) 2,(11.80T ut F -5209.2) psig 2(11.80 Tout F -5209.2) psig o

.. _ ___.j _..

- 110 i

(-21,104);

, (12,104) 100 _ _

__._-.__4._.

I I

i

(-29,95) i ACCEPTABLE (29,90) 4 (UMP 90

)

OPERATION

.... 4...

._L-},77.68).

80J 12,77. 68).._

i 70.

(-29,63!68) l

< > (29,63.68) i 1

.. 60 ACCEPTABLE g 384 PUMP a-OPERATION ;.. 50 E

U i

.4

. 4 0.___ _._. _ _

=

I E

i

.h j

.E_ _ 30 e

i i

j-20 2

'3 - - 10 o

i E

i n

-50

-40

-30

-20

-10 0

+10

+20

+30

+40 +50 AXIAL POWER IMBALANCE, %

FIGURE 2.2-1 TRIP SETPOINT FOR NUCLEAR OVERPOWER BASED ON RCS FLOW AND AXIAL POWER IMBALANCE CRYSTAL RIVER - UNIT 3 2-7

2.1 SAFETY LIMITS BASES 2.1.1 and 2.1.2 REACTOR CORE The restrictions of this safety limit prevent overheating of the fuel clad-ding and possible cladding perforation which would result in the release of fission products to the reactor coolant.

Overheating of the fuel cladding is prevented by restricting fuel operation to within the nucleate boiling regime where the heat transfer coefficient is large and the cladding surface temperature is slightly above the coolant saturation temperature.

Operation above the upper boundary of the nucleate boiling regime would result in excessive cladding temperatures because of the onset of departure from nucleate boiling (DNB) and the resultant sharp reduction in heat trans-fer coefficient.

DNB is not a directly measurable parameter during opera-tion and therefore THERMAL POWER and Reactor Coolant Temperature and Pres-sure have been related to DNB through the BAW-2 DNB correlation.

The DNB correlation has been developed to predict the DNB flux and the location of DNB for axially uniform and non-uniform heat flux di;'.ributions.

The local DNB heat flux ratio, DNBR, defined as the ratio of the heat flux that would cause DNB at a particular core location to the local heat flux, is indica-tive of the margin to DNB.

The minimum value of the DNBR during steady state operation, normal opera-tional transients, and anticipated transients is limited to 1.30.

This value corresponds to a 95 percent probability at a 95 percent confidence level that DNB will not occur and is chosen as an appropriate margin to DNB for all ( 'erating conditions.

The curve presented in Figure 2.1-1 represents the conditions at which a minimum DNBR of 1.30 is predicted for the maximum possible thermal power, 112%, when the reactor coolant flow is 139.7 x 106 lbs/hr, which is 106.5%

of the design flow rate for four operating reactor coolant pumps.

This curve is based on the following nuclear power peaking factors with potential fuel densification effects:

FN = 2.57; FN

= 1. 71 ; FN = 1.50 Q

H Z

The design limit power peaking factors are the most restrictive calculated at full power for the range from all control rods fully withdrawn to minimum allowable control rod withdrawal, and form the core DNBR design basis.

CRYSTAL RIVER - UNIT 3 B 2-1 l

l l

~

LIMITING SAFETY SYSTEM SETTINGS BASES RCS Outlet Temperature - High The RCS Outlet Temperature High trip <619*F prevents the reactor outlet tem-perature from exceeding the design limits and acts as a backup trip for all power excursion transients.

Nuclear Overpower Based on RCS Flow and AXIAL POWER IMBALANCE The power level trip setpoint produced by the reactor ccolant system flow is based on a flux-to-flow ratio which has been established to accommodate flow decreasing transients from high power.

The power level trip setpoint produced by the power-to-flow ratio provides both high power level and low flow protection in the event the reactor power level increases or the reactor coolant flow rate decreases.

The power level setpoint produced by the power-to-flow ratio provides overpower DNB protec-tion for all modes of pump operation.

For every flow rate there is a maxi-mum permissible power level, and for every power level there is a minimum permissible low flow rate.

Typical power level and low flow rate combina-tions for the pump situations of Table 2.2-1 are as follows:

1.

Trip would occur when four reactor coolant pumps are operating if power is >104.0% and reactor flow rate is 100%, or flow rate is

<96.1% and power level is 100%.

2.

Trip would occur when three reactor coolant pumps are operating if power is >77.68% and reactor flow rate is 74.7%, or flow rate is 172.12% a6d power is 75%.

For safety calculations the maximum calibratic and instrumentation errors for the power level were used.

CRYSTAL RIVER - UNIT 3 B 2-5

4 LIMITING SAFETY SYSTEf1 SETTINGS BASES The AX1AL POWER IMBALANCE boundaries are established in order to prevent reactor thermal limits from being exceeded.

These thermal limits are ei-ther power peaking kw/ft limits or DNBR limits.

The AXIAL POWER IMBALANCE reduces the power level trip produced by the flux-to-flow ratio such that the boundaries of Figure 2.2-1 are produced.

The flux-to-flow ratio reduc-es the power level trip and associated reactor power-reactor power-imbalance boundaries by 1.04% for a 1% flow reduction.

RCS Pressure - Low, High and Variable Low The High and Low trips are provided to limit the pressure range in which reactor operation is permitted.

During a slow reactivity insertion startup accident from low power or a slow reactivity insertion from high power, the RCS Pressure-High setpoint is reached before the Nuclear Overpower Trip Setpoint.

The trip setpoint for RCS Pressure-High, 2300 psig, has been established to maintain the sys-tem pressure below the safety limit, 2750 psig, for any design transient.

The RCS Pressure-High trip is backed up by the pressurized code safety valves for RCS over pressure protection, and is therefore set lower than the set pressure for these valves, 2500 psig.

The RCS Pressure-High trip also backs up the Nuclear Overpower trip.

The RCS Pressure-Low, 1800

psig, and RCS Presssure-Variable
Low, (11.80 Tout F-5209.2) psig, Trip Setpoints have been established to main-tain the DNB ratio greater than or equal to 1.30 for those design accidents that result in a pressure reduction.

It also prevents reactor operation at pressures below the valid range of DNB correlation limits, protecting against DNB.

Due to the calibration and instrumentation errors, the safety analysis used a RCS Pressure-Variable Low Trip Setpoint of (11.80 Tout F-5249.2)psig.

CRYSTAL RIVER - UNIT 3 8 2-6 e

4 2400 2200 na E

L 2

g S

U 2

2000

/

b 1800 1600 1

580 600 620 640 660 Reactor Outlet Temp, F

REACTOR COOLANT FLOW PUMPS OPERATING CURVE FLOW (% Design)

POWER (RTP)

(TYPE OF LIMIT) 1 139.7 x 106 (106.5%)

117.3%

4 Pumps (DNBR) 2 104.4 x 10 (79.6%)

90.5%

3 Pumps (DNBR) i PRESSURE / TEMPERATURE LIMITS AT MAXIMUM 1

ALLOWABLE POWER FOR MINIMUM DNBR BASES FIGURE 2.1 l

CRYSTAL RIVER - UNIT 3 B 2-8 l

3/4.1 REACTIVITY CONTROL SYSTEMS 3/4.1.1 B0 RATION CONTROL SHUTDOWN MARGIN-0PERATING LIMITING CONDITION FOR OPERATION 3.1.1.1.1 The SHUTDOWN MARGIN shall be 21% ak/k.

APPLICABILITY:

MODES 1, 2* and 3.

ACTION:

With the SHUTDOWN MARGIN <1% ak/k, immediately initiate and continue boration with one of the OPERABLE borated water sources of Specifica-tion 3.1.2.9 until the required SHUTDOWN MARGIN is restored.

SURVEILLANCE REQUIREMENTS 4.1.1.1.1.1 The SHUTDOWN MARGIN shall be determined to be 2.1% Ak/k:

Within one hour after detection of an inoperable control rod (s) a.

and at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> thereafter while the rod (s) is in-operable.

If the inoperable control rod is immovable or untripp-able, the above required SHUTDOWN MARGIN shall be increased by an amomd at least equal to the withdrawn worth of the immovable or untrip',able control rod (s).

b.

When in MODES 1 or 2, at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, by verifying that regulating rod groups withdrawal is within the limits of Speci fication 3.1.3.6.

c.

When in Mode 28# within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> prior to achieving reactor criticality by verifying that the predicted critical control rod position is within the limits of Specification 3.1.3.6.

d.

Prior to initial operation above 5% RATED THERMAL POWER after each fuel loading by consideration of the factors of e. below, with the regulating rod groups at the maximum insertion limit of Specification 3.1.3.6.

  1. With Keff >1.0.
    1. With Keff <1.0.
  • See Special Test Exception 3.10.4.

CRYSTAL RIVER - UNIT 3 3/4 1-1

3/4.1 REACTIVITY CONTROL SYSTEMS 3/4.1.1 B0 RATION CONTROL SHUTDOWN MARGIN-SHUTDOWN LIMITING CONDITION FOR OPERATION 3.1.1.1.2 The SHUTDOWN MARGIN shall be >3.0% Ak/k.

APPLICABILITY: MODES 4 and 5.

ACTION:

MODE 4 With the SHUTDOWN MARGIN <3.0% A k/k, immediately initiate and continue boration with one of the OPERABLE borated water sources of Specifica-tion 3.1.2.9 until the required SHUTDOWN MARGIN is restored.

MODE 5 With the SHUTDOWN MARGIN <3.0% A k/k, inmediately initiate and continue boration with one of the OPERABLE borated water sources of Specifica-tion 3.1.2.8 until the required SHUTDOWN MARGIN is restored.

SURVEILLANCE REQUIREMENTS 4.1.1.1.2.1 The SHUTDOWN MARGIN shall be determined to be >3.0% Ak/k:

Within one hour after detection of an inoperable control rod (s) a.

and at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> thereafter while the rod (s) is in-operable.

If the inoperable control rod is immovable or untripp-able, the above required SHUTDOWN MARGIN shall be increased by an amount at least equal to the withdrawn worth cf the immovable or untrippable control rod (s).

b.

At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> by consideration of the following fac-tors:

1.

Reactor coolant system boron concentration, 2.

Control rod position, 3.

Reactor coolant system average temperature, 4.

Fuel burnup based on gross thermal energy generation, 5.

Xenon concentration, and 6.

Samarium concentration CRYSTAL RIVER - UNIT 3 3/4 1-2a

REACTIVITY CONTROLS SYSTEMS FLOW PATHS - OPERATING LIMITING CONDITION FOR OPERATION 3.1.2.2 Each of the following boron injection flow paths shall be OPERABLE:

A flow path from the concentrated boric acid storage system via a a.

boric acid pump and makeup or decay beat removal (DHR) pump to the Reactor Coolant System, and b.

A flow path from the borated water storage tank via nakeup or DHR pump to the Reactor Coolant System.

APPLICABILITY: MODES 1, 2, 3 and 4.

ACTION:

MODES 1, 2 and 3 With the flow path from the concentrated boric acid storage system a.

inoperable, restore the inoperable flow path to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY and borated to a SHUTDOWN MARGIN equivalent to 1% Ak/k at 200 F within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; restore the flow path to OPERABLE status within the next 7 days or be in COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />, b.

With the flow path from the borated water storage tank inoperable, restore the flow path to OPERABLE status within one hour or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

MODE 4 With the flow path from the concentrated boric acid storage system a.

inoperable, restore the inoperable flow path to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be borated to a SHUTDOWN MARGIN equivalent to 3.0% Ak/k at 200*F within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; restore the flow path to OPERABLE status within the next 7 days or be in COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

CRYSTAL RIVER - UNIT 3 3/41-7 i

i

~

REACTIVITY CONTROLS SYSTEMS FLOW PATHS - OPERATING LIMITING CONDITION FOR OPERATION j

ACTION:

(Continued) b.

With the flow path from the borated water storage tank inoper-able, restore the flow path to OPERABLE status within one hour or be in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.1.2.2 Each of the above required flow paths shall be demonstrated OPER-ABLE:

a.

At least once per 7 days by verifying that the pipe temperature of the heat traced portion of the flow path from the concentrated boric acid storage system is > 105 F.

b.

At least once pc-31 days by verifying that each valve (manual, power operated or automatic) in the flow path that is not locked, sealed, or otherwise secured in position, is in its correct position.

CRYSTAL RIVER - UNIT 3 3/4 1-8 l

L

REACTIVITY CONTROL SYSTEMS MAKEUP PUMPS - OPERATING l

LIMITING CONDITION FOR OPERATION 3.1.2.4.1 At least two makeup pumps shall be OPERABLE.

APPLICARILITY: MODES 1, 2, and 3 ACTION:

With only one nukeup pump ?DERABLE, restore at least two makeup pumps to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY and borated to a SHUTDOWN MARGIN equivalent to 1% Ak/k at 200 F within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; restore at least two makeup pumps to OPERABLE status within the next 7 days or be in COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.1.2.4.1 No additional Surveillance Requirements other than those requir-ed by Specification 4.0.5.

I CRYSTAL RIVER - UNIT 3 3/4 1-10 i

REACTIVITY CONTROL SYSTEMS MAKEUP PUMPS - OPERATING LIMITING CONDITION FOR OPERATION 3.1.2.4.2 At least one makeup pump shall be OPERABLE.

APPLICABILITY: MODE 4*

ACTION:

With no makeup pump OPERABLE, restore at least one makeup pump to OPERABLE status within one hour or be borated to a SHUTDOWN MARGIN equivalent to 3.0% ak/k at 200*F and be in COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SUf'VEILLANCE REQUIREMENTS 4.1.2.4.2 No additional Surveillance Requirements other than those requir-ed by Specification 4.0.5.

  • With RCS pressure > 150 psig.

CRYSTAL RIVER - UNIT 3 3/4 1-10a

REACTIVITY CONTROL SYSTEMS BORIC ACID PUMPS - OPERATING LIMITING CONDITION FOR OPERATION 3.1.2.7 At least one boric acid pump in the boron injection flow path required by Specification 3.1.2.2a shall be OPERABLE and capable of being powered from an OPERABLE emergency bus if the flow path through the boric acid pump in Specification 3.1.2.2a is OPERABLE.

APPLICABILITY: MODES 1, 2, 3 and 4.

ACTION:

MODES 1, 2 and 3 With no boric acid pump OPERABLE, restore at least one boric acid pump to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY and borated to a SHUTDOWN MARGIN equivalent to 1% ak/k at 200 F within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; restore at least one boric acid pump to OPERABLE status within the next 7 days or be in COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

MODE 4 With no boric acid pump OPERABLE, restore at least one boric acid pump to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be borated to a SHUTDOWN MARGIN equivalent to 3.0% ak/k at 200 F within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; restore at least one boric acid pump to OPERABLE status within the next 7 days or be in COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.1.2.7 No additional Surveillance Requirements other than those required by Specification 4.0.5.

CRYSTAL RIVER - UNIT 3 3/4 1-13

REACTIVITY CONTROL SYSTEMS B0 RATED WATER SOURCES - OPERATING LIMITING CONDITION FOR OPERATION 3.1.2.9 Each of the following borated water sources shall be OPERABLE:

a.

The concentrated boric acid storage system and associated heat tracing with:

1.

A minimum contained borated water volume of 6615 gallons, 2.

Between 11,600 and 14,000 ppm of boron, and 3.

A minimum solution temperature of 105*F.

b.

The borated water storage tank (BWST) with:

1.

A contained borated water volume of between 415,200 and 449,000 gallons, 2.

Between 2270 and 2450 ppm of boron, and 3.

A minimum solution temperature of 40 F.

APPLICABILITY: MODES 1, 2, 3 and 4.

ACTION:

MODES 1, 2 and 3:

With the concentrated boric acid storage system inoperable, re-a.

store the storage system to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least H0T STANDBY and borated to a SHUTDOWN MARGIN equiva-lent to 1% a k/k at 200'F within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; restore the concentrated boric acid storage system to OPERABLE status within the next 7 days or be in COLD SHUTD0WN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

b.

With the borated water storage tank inoperable, restore the tank to OPERABLE status within one hour or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

MODE 4:

a.

With the concentrated boric acid storage system inoperable, re-store the storage system to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be CRYSTAL RIVER - UNIT 3 3/4 1-16

REACTIVITY CONTROL SYSTEMS B0 RATED WATER SOURCES - OPERATING LIMITING CONDITION FOR OPERATION ACTION:

(Continued) borated to a SHUTOOWN MARGIN equivalent to 3.0% ak/k at 200'F within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; restore the concentrated boric acid storage system to OPERABLE status within the next 7 days or be in COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

b.

With the borated water storage tank inoperable, restore the tank to OPERABLE status within one hour or be in COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.1.2.9 Each borated water source shall be demonstrated OPERABLE:

a.

At least once per 7 days by:

1.

Verifying th m on concentration in each water source, s

2.

Verifying the cantained borated water volume of each water source, and 3.

Verifying the concentrated boric acid storage system solution temperature, b.

At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> by verifying the BWST temperature when the outside air temperature is < 40*F.

CRYSTAL RIVER - UNIT 3 3/4 1-17

\\

110 I

(177,102)

(230,102) 100 POWER LEVEL CUT 0FF (92% RATED THERMAL POWER)

(230,90) 90 (177,90) l (250,80) 80 UNACCEPTABLE (161,so)

OPERAil0N t

70 i

a a.

60 E

e 5

50 (100,50)

(300,50) g

~

E 40

'o 30 d

ACCEPTABLE 5

20 -

OPERATION 10 -

I*)

0, I

0 50 100 150 200 250 300 0

25 50 75 100 0

25 50 75 100 l

I I

1 1

1 I

I f

f Group 5 Group 7 0

25 50 75 100 l

l l

t l

Group 6 FIGURE 3.1-1 REGULATING R00 GROUP INSERTION LIMITS FOR 4 PUMP OPERATION FROM 0 EFPD TO 250 + 10 EFPD l

CRYSTAL RIVER - UNIT 3 3/4 1-27 l

o

110 (300,102) 100 (2si,io2);

POWER LEVEL CUT 0FF 90

( 92%0F RATED THERMAL POWER)

,(261,90) t

[

80 (250,s0) 70 5

UN ACCEPT ABL E E

60 OPERAll0N E

E 50 g,73,3o) d 40 b

30 20 ACCEPTABLE OPERATION 10 0

(0'0) i e

i e

i i

0 50 100 150 200 250 300 Rod Index, % Withdrawn 0

25 50 75 100 0

25 50 75 100 i

i i

i i

i Group 5 Group 7 0

25 50 75 100 t

i l

I

_]

Group 6 FIGURE 3.1-2 REGULATING R0D GROUP INSERTION LIMITS FOR 4 PUMP OPERATION AFTER 250 + 10 EFPD l

CRYSTAL RIVER - UNIT 3 3/4 1-28

110 100 UNACCEPTABLE 90 OPERATION 80 (esi,7s.5)

(250.7s.5)

U.

E 70 Ey 60 5

50 g

(100,48)

(300.48) 40 Ef 30 -

20 ACCEPTABLE OPERATION 10 0

(0'0) i i

i e

t 0

50 100 150 200 250 303 Rod index, % Witridrawn 0

25 50 75 100 0

25 50 75 100

[

t t

i e

t i

t I

i Grcup 5 Graup 7 0

25 50 75 100 1

I I

f I

Orcup 6 FIGURE 3.1-3 REGULATING ROD GROUP INSERTION LIMITS FOR 3 PUMP OPERATION FROM 0 EFPD TO 250 + 10 EFPD CRYSTAL RIVER - UNIT 3 3/4 1-29

)

i i

u

110 100 UNACCEPTABLE 90 OPERATION

-[

80 (250,76.5) 70 I'

E

~

E s-60 o

c:

50 o

(175,48) 40 E

E 30 ACCEPTABLE OPERATION 20 10 0.

0.0) i e

i I

i 0

50 100 150 200 250 300 Rod Index, % Withdrawn 0

25 50 15 100 0

25 50 75 100 t

i f

i i

t I

i l

i Group 5 Group 7 0

25 50 75 100 t

f f

I I

Group 6 FIGURE 3.1-4 REGULATING R00 GROUP INSERTION LIMITS FOR 3 PUMP OPERATION AFTER 250 + 10 EFPD CRYSTAL RIVER - UNIT 3 3/4 1-30

110 (10,102)

(36,102) 100 UNACCEPTABLE

I ON (36.90) 90 (o.so)

(us,so) 80 m

E2 70 5

5 60 ACCEPTABLE g

OPERATION

~

(100,50) o 40 E

d' 30 20 10 0

i 0

10 20 30 40 50 60 70 80 90 100 Rod Position, $ Withdrawn FIGURE 3.1-9 AXIAL POWER SHAPING R00 GROUP INSERTION LIMITS FROM 0 EFPD TO 250 + 10 EFPD CRYSTAL RIVER - UNIT 3 3/4 1-38 l

l

1 i

110 (10,102)

(37,102) 100 UNACCEPTABLE OPERATION 90

,g,,,,,)

,( 37,go) 80 < (o.ao)

( so, so )

a d5 70 E

j 60 ACCEPTABLE o

50 SE OPERATION (100,50)

[$

40 i

a 30 m

20 10 0

i i

i i

i i

i i

0 10 20 30 40 50 60 70 80 90 100 Rod Position, 5 Withdrawn FIGURE 3,1-10 AXIAL POWER SHAPING R00 GROUP INSERTION LIMITS AFTER 250 + 10 EFPD CRYSTAL RIVER - UNIT 3 3/4 1-39

-110

(-20.102)

C p (+10.2.102) i

( 20,90)

-- 90

'(+10.8.90)

(-25.80)

- - 80

( + 12. 80)

E

- - 70 55

- - 60 UNACCEPTABLE ACCEPTABLE o

OPERATION OPERATION gg

- - 50 E

40 U

J?

- - 30

- - 20

- - 10 i

i I

i

-30

-20

-10 0

+10

+20

+30 Axial Power imoalance, t FIGURE 3.2-1 AXI AL POWER IMBALANCE ENVELOPE FOR OPERATION FROM 0 EFPD TO 250 + 10 EFPD CRYSTAL RIVER - UNIT 3 3/4 2-2 o

- 110

(-25.102)n

(+18 3 102)

- 100

(-25.90)

- - 90

(+18 0.90)

( 30.80)

- - 80

'(+19.6 80)

}

' - 10 E

. - 60 E

UN ACCEPT ABL E ACCEPTABLE

- - 50 OPERATION OPERAil0N E

E

- - 40 e

- - 30

- - 20

- - 10 i

i

-30

-20

-10 0

+10

+20

+30 Axlal Power imcalance, Y,

i FIGURE 3.2-2 AXIAL POWER IMBALANCE ENVELOPE FOR OPERATION AFTER 250 + 10 EFPD CRYSTAL RIVER - UNIT 3 3/42-3

TABLE 3.2-2 QUADRANT POWER TILT LIMITS STEADY STATE TRANSIENT MAXIMUM j

LIMIT LIMIT LIMIT QUADRANT POWER TILT as Measured by:

Symmetrical Incore Detector System 3.31 8.81 20.0 Power Range Channels 1.96 6.96 20.0 Minimum Incore Detector System 1.90 4.40 20.0 1

I i

i CRYSTAL RIVER - UNIT 3 3/4 2-11

TABLE 3.2-1 DNB MARGIN LIMITS Four Reactor Three Reactor Coolant Pumps Coolant Pumps Parameter Operating Operating Reactor Coolant Hot Leg Temperature, Tg*F

< 604.6

< S04.6(1)

Reactor Coolant Pressure, psig(2)

> 2061.6

> 2057.2(1)

Reactor Coolant Flow Rate, Ib/hr

> 139.7x106

> 104.4x106 (1) Applicable to the loop with 2 Reactor Coolant Pumps Operating.

(2) Limit not applicable during either a THERMAL POWER ramp increase in excess of 5% of RATED THERMAL POWER per minute or a THERMAL POWER step increase greater than 10% of RATED THERMAL POWER.

l

\\

l l

l l

CRYSTAL RIVER - UNIT 3 3/4 2-13

3/4.4 REACTOR COOLANT SYSTEM REACTOR COOLANT LOOPS LIMITING CONDITION FOR OPERATION 3.4.1 Both reactor coolant loops and both reactor coolant pumps in each loop shall be in operation.

APPLICABILITY: As noted below, but excluding MODE 6.*

ACTION:

MODES 1 and 2:

With one reactor coolant pump not in operation, STARTUF and POWER OPERATION may be initiated and may proceed provided THERMAL POWER is restricted to less than 77.68% of RATED THERMAL POWER and within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> the setpoint for the Nuclear Overpower trip has been reduced to the value specified in Specification 2.2.1 for operation with three reactor coolant pumps operating:

MODES 3, 4 and 5:

Operation may proceed provided at least one reactor coolant loop a.

is in operation with an associated reactor coolant pump or decay heat removal pump.

b.

The provisions of Specifications 3.0.3 and 3.0.4 are not applicable.

SURVEILLANCE REQUIREMENTS 4.4.1 The Reactor Protective Instrumentation channels specified in the applicable ACTION statement al.ve shall be verified to have had their trip setpoints changed to the values specified in Specification 2.2.1 for the applicable number of reactor coolant pumps operating either:

Within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> after switching to a different pump combination if a.

the switch is made while operating, or b.

Prior to reactor criticality if the switch is made while shut down.

  • See Special Test Exception 3.10.3.

CRYSTAL RIVER - UNIT 3 3/4 4-1 l

9 o

e SPECIAL TEST EXCEPTION SHUTDOWN MARGIN LIMITING CONDITION FOR OPERATION 3.10.4 The SHUIDOWN MARGIN requirenent of Specification 3.1.1.1.1 may be suspended for measurement of control rod worth and shutdown margin provid-ed:

a.

Reactivity equivalent to at least the highest estimated control rod worth is available for trip inser+, ion from 0PERABLE control rod (s),and b.

All axial power shaping rods are withdrawn to at least 35% (indi-cated position) and OPERABLE.

APPLICABILITY: MODE 2.

ACTION:

a.

With any safety or regulating control rod not fully inserted and with less than the above reactivity equivalent available for trip insertion or the axial power shaping rods not within their with-drawal limits, immediately initiate and continue boration with one of the OPERABLE borated water sources of Specification 3.1.2.9 un-til the SHUTDOWN MARGIN required by Specification 3.1.1.1.1 is re-stored.

b.

With all safety or regulating control rods fully inserted and the reactor subtritical by less than the above reactivity equivalent, immediately initiate and continue boration with one of the OPERABLE borated water sources of Specification 3.1.2.9 until the SHUTDOWN MARGIN required by Specification 3.1.1.1.1 is restored.

SURVEILLANCE REQUIREMENTS 4.10.4.1 The position of each safety, regulating, and axial power shaping rod either partially or fully withdrawn shall be determined at least once per 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.

4.10.4.2 Each safety or regulating control rod not fully inserted shall be demonstrated capable of full insertion when tripped from at least the 50% withdrawn position within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to reducing the SHUTDOWN MAR-GIN to less than the limits of Specification 3.1.1.1.1.

4.10.4.3 The axial power shaping rods shall be demonstrated OPERABLE by moving each axial power shaping rod > 6.5% (indicated position) within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> prior to reducing the SHUTDOWN MARGIN to less than the limits of Specification 3.1.1.1.1 CRYSTAL RIVER - UNIT 3 3/4 10-4 l

l

3/4.1 REACTIVITY CONTROL SYSTEMS o

3/4.1.1 B0 RATION CONTROL SHUTDOWN MARGIN 3/4.1.1.1 SHUTDOWN MARGIN A sufficient SHUTDOWN MARGIN ensures that 1) the reactor can be made subcritical from all operating conditions, 2) the reactivity transients associated with postulated accident conditions are controllable within acceptable limits, and 3) the reactor will be maintained sufficiently subcritical to preclude inadvertent criticality in the shutdown condition.

During Modes 1 and 2 the SHUTDOWN MARGIN is known to be within limits if all control rods are OPERABLE and withdrawn to or beyond the insertion limits.

SHUTDOWN MARGIN requirements vary throughout core life as a function of fuel depletion, RCS baron concentration and RCS T The most restrictive condition for Modes 1, 2, and 3 occurs at E0L, win T at no load operating temperature, and is associated with a postubed steam line break accident and resulting uncontrolled RCS cooldown.

In the analysis of this accident a minimum SHUTD0WN MARGIN of 0.60% Ak/k is initially required to control the reactivity transient.

Accordingly, the SHUTDOWN MARGIN required is based upon this limiting condition and is consistent with FSAR safety analysis assumptions.

The most restrictive condition for MODES 4 and 5 occurs at BOL, and is associated with deboration due to inadvertent injection of sodium hydroxide. The higher requirement for these modes inSJre the accident will not result in criticality.

3/4.1.1.2 BORON DILUTION A minimum flow rate of at least 2700 GPM provides adequate mixing, prevents stratification and ensures that reactiivity changes will be gradual through the Reactor Coolant System in the core during baron concentration reductions in the Reactor Coolant System. A flow rate of at least 2700 GPM will circulate an equivalent Reactor Coolant System volume of 12.nn0 cubic feet in approximately 30 minutes. The reactivity change ran c;: sciated with boron concentration reduction will be within the capability for operator recognition and control.

3/4.1.1.3 MODERATOR TEMPERATURE C0 EFFICIENT The limitations on moderator temperature coefficient (MTC) are provided to ensure that the assumptions used in the accident and transit analyses remain valid through each fuel cycle. The surveillance requirement for measurment of the MTC each fuel cycle are adequate to confirm the MTC value since this coefficient changes slowly due principally to the reduction in RCS boron concentration associated with fuel burnup. The confirmation that the measured MTC value is within its limit provides assurance that the coefficient will be maintained within acceptable values throughout each fuel cycle.

CRYSTAL RIVER - UNIT 3 8 3/4 1-1

O O

REACTIVITY CONTROL SYSTEMS BASES 3/4.1.1.4 MINIMUM TEMPFRATURE FOR CRITICALITY This specification ensures that the reactor will not be made critical with the Reactor Coolant System average temperature less than 525 F.

This limi-tation is required to ensure 1) the moderator temperature coefficient is within its analyzed temperature range, 2) the protective instrumentation is within its normal operating range, 3) the pressurizer is capable of being in an OPERABLE status with a steam bubble, and 4) the reactor pressure ves-sel is above its minimum RTNDT temperature.

3/4.1.2 BORATION SYSTEMS The boron injection system ensures that negative reactivity control is available during each mode of facility operation. The components required to perform this function include 1) borated water sources, 2) nakeup or DHR pumps, 3) separate flow paths, 4) boric acid pumps, 5) associated heat tracing systems, and 6) an emergency power supply from OPERABLE emergency busses.

With the RCS average temperature above 200 F, a minimum of two separate and redundant boron injection systems are provided to ensure single functional capability in the event an assumed failure renders one of the systems inoperable. Allowable out-of-service periods ensure that minor component repair or corrective action ney be completed without undue risk to overall facility safety from injection system failures during the repair period.

The boration capability of either system is sufficient to provide a SHUT-DOWN MARGIN from all operating conditions of 3.0% ok/k after xenon decay and cooldown to 200 F.

The maximum boration capability requirement occurs at E0L from full power equilibrium xenon conditions and requires either 6615 gallons of 11,600 ppm boron from the boric acid storage tanks or 45,421 gallons of 2270 ppm boron from the borated water storage tank.

The requirements for a minimum contained volume of 415,200 gallons of borated water in the borated water storage tank ensures the capability for borating the RCS to the desired level. The specified quantity of borated water is consistent with the ECCS requirements of Specification 3.5.4.

Therefore, the larger volume of borated water is specified.

With the RCS temperature below 200*F, one injection system is acceptable without single failure consideration on the basis of the stable reactivity condition of the reactor and the additional restrictions prohibiting CORE ALTERATIONS and positive reactivity change in the event the single injec-tion system becomes inoperable.

CRYSTAL RIVER - UNIT 3 B 3/4 1-2

9

~

REACTIVITY CONTROL SYSTEMS BASES 3/4.1.E BORAT10N SYSTEMS (Continued)

The boron capability required in Modes 4 and 5 is based on a potential moderator dilution accident and is sufficient to provide a SHUTDOWN MARGIN of 3.0% ak/k after xenon decay and and cooldown from 200*F to 140 F.

This condition requires either 300 gallons of 11,600 ppm boron from the boric acid storage system or 1608 gallons of 2270 ppm boron from the borated water storage tank. To envelop future cycle BWST contained borated water volume requirements, a minimum volume of 13,500 gallons is specified.

The contained water volume limits include allowance for water not available because of discharge line location and other physical characteristics. The limits on contained water volume and boron concentration ensure a pH value of between 7.2 and 11.0 of the solution sprayed within containment after a design basis accident. The pH band minimizes the evolution of iodine and minimizes the effect of chloride and caustic stress corrosion cracking on mechanical systems and components.

The OPERABILITY of one boron injection system during REFUELING ensures that this system is available for reactivity control while in MODE 6.

3/4.1.3 MOVABLE CONTROL ASSEMBLIES The specifications of this section (1) ensure that acceptable power distribution limits are maintained, (2) ensure that the minimum SHUTDOWN MARGIN is maintained, and (3) limit the potential effects of a rod ejection accident. OPERABILITY of the control rod position indicators is required to determine control rod positions and thereby ensure compliance with the control rod alignment and insertion limits.

The ACTION statements which permit limited variations from the basic requirements are accompanied by additional restrictions which ensure that

~

the original criteria are met. For example, misalignment of a safety or regulating rod requires a restriction in THERMAL POWER.

The reactivity worth of a misaligned rod is limited for the remainder of the fuel cycle to prevent exceeding the assumptions used in the safety analysis.

l The position of a rod declared inoperable due to misalignment should not be l

included in computing the average group position for determining the OPERABILITY of rods with lesser misalignments.

CRYSTAL RIVER - UNIT 3 B 3/4 1-3

,