March 28, 2006 Mr. Ronald A. Jones Vice President, Oconee Site Duke Energy Corporation 7800 Rochester Highway Seneca, SC 29679

SUBJECT:

SUMMARY

OF NOVEMBER 1, 2005, CONFERENCE CALL REGARDING THE FALL 2005 STEAM GENERATOR TUBE INSPECTIONS AT OCONEE NUCLEAR STATION, UNIT 2 (OCONEE 2) (TAC NO. MC8653)

Dear Mr. Jones:

On November 1, 2005, Nuclear Regulatory Commission (NRC) staff of the Steam Generator Tube Integrity and Chemical Engineering Branch, Division of Component Integrity, participated in a conference call with the licensee (Duke Energy Nuclear, LLC) to discuss the scope, results, and status of steam generator tube inspections being conducted at that time, at Oconee 2 (Fall 2005 Refueling Outage). Enclosed please find 1) the NRCs Conference Call Summary, 2) the NRCs Inspection Discussion Points, 3) the Examination Status Report, and 4) the Indication Orientation Maps.

Sincerely,

/RA/

Leonard N. Olshan, Sr. Project Manager Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-270

Enclosures:

1. NRCs Conference Call Summary
2. NRCs Inspection Discussion Points
3. Examination Status Report
4. Indication Orientation Maps cc w/encls: See next page

ML060550049 NRC-001 OFFICE NRR/LPL2-1/PM NRR/LPL2-1/PM NRR/LPL2-1/LA NRR/LPL2-1/BC NAME SLingam LOlshan MOBrien EMarinos DATE 3/21/06 3/21/06 3/16/06 3/28/06 Oconee Nuclear Station, Units 1, 2, and 3 cc:

Ms. Lisa F. Vaughn Mr. R. L. Gill, Jr.

Duke Energy Corporation Manager - Nuclear Regulatory 526 South Church Street Issues and Industry Affairs P. O. Box 1006 Duke Energy Corporation Mail Code = EC07H 526 S. Church St.

Charlotte, North Carolina 28201-1006 Mail Stop EC05P Charlotte, NC 28202 Manager, LIS NUS Corporation Division of Radiation Protection 2650 McCormick Dr., 3rd Floor NC Dept of Environment, Health, & Natural Clearwater, FL 34619-1035 Resources 3825 Barrett Dr.

Senior Resident Inspector Raleigh, NC 27609-7721 U.S. Nuclear Regulatory Commission 7812B Rochester Highway Mr. Peter R. Harden, IV Seneca, SC 29672 VP-Customer Relations and Sales Westinghouse Electric Company Mr. Henry Porter, Director 6000 Fairview Road Division of Radioactive Waste Management 12th Floor Bureau of Land and Waste Management Charlotte, NC 28210 Dept. of Health and Env. Control 2600 Bull St. Mr. Henry Barron Columbia, SC 29201-1708 Group Vice President, Nuclear Generation and Chief Nuclear Officer Mr. Michael A. Schoppman P.O. Box 1006-EC07H Framatome ANP Charlotte, NC 28201-1006 1911 North Ft. Myer Dr.

Suite 705 Rosslyn, VA 22209 Mr. B. G. Davenport Regulatory Compliance Manager Oconee Nuclear Site Duke Energy Corporation ON03RC 7800 Rochester Highway Seneca, SC 29672 Ms. Karen E. Long Assistant Attorney General NC Department of Justice P.O. Box 629 Raleigh, NC 27602