Letter Sequence Response to RAI |
---|
TAC:ME4640, Steam Generator Tube Integrity (Approved, Closed) |
Results
- Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval
Other: L-11-114, Drawing No. M-042B, Rev. 35, Sampling System Sh. 2 Local Grab Samples, L-11-131, Drawing No. LR-OS041A2, Revision 1, Operational Schematic Emergency Diesel Generator Systems., L-11-334, Reply to Request Additional Information for the Review of the License Renewal Application Amendment No. 21, L-12-337, Review of the Safety Evaluation Report with Open Items Related to the License Renewal, L-12-444, Submittal of Contractor Equivalent Margins Assessments for Reactor Vessel Welds (Nonproprietary Versions), L-12-456, Notification of Closure of Commitments Related to the Review of the License Renewal Application, L-13-257, Notification of Completion of a License Renewal Commitment Related to the Review of License Renewal Application TAC No. ME4640) and License Renewal Application Amendment No. 45), L-13-330, License Renewal Application Amendment No. 46 - Annual Update, L-13-341, Review of the Safety Evaluation Report Related to the License Renewal of Davis-Besse Nuclear Power Station, L-14-085, License Renewal Application (TAC No. ME4640) Amendment No. 48, L-14-206, License Renewal Application Amendment No. 50 - Annual Update, L-15-120, Notification of Completion of License Renewal Commitments Related to the Review of the Davis-Besse Nuclear Power Station, Unit No. 1, License Renewal Application and License Renewal Application Amendment No. 55, L-15-139, License Renewal Reactor Vessel Internals Inspection Plan, L-15-214, License Renewal Application Amendment No. 59 - Annual Update, L-15-309, License Renewal Application Amendment No. 60, L-15-310, C-CSS-099.20-069, Rev 0, Shield Building Laminar Cracking Limits., ML102450565, ML111050091, ML11110A089, ML11110A091, ML11110A092, ML11110A093, ML11110A094, ML11110A095, ML11110A105, ML11110A106, ML11110A107, ML11122A014, ML11126A017, ML11126A018, ML11126A019, ML11126A020, ML11126A021, ML11126A022, ML11126A023, ML11126A024, ML11126A025, ML11126A026, ML11126A032, ML11126A033, ML11126A034, ML11126A035, ML11126A036, ML11126A037, ML11126A038, ML11126A039, ML11126A040, ML11126A041, ML11126A042, ML11126A043... further results
|
MONTHYEARML11126A0882008-01-12012 January 2008 Drawing No. LR-M041B, Revision 1, Piping & Instrument Diagram Primary Service Water System. Job Code 12501 Project stage: Other ML11126A0902008-01-15015 January 2008 Drawing No. LR-OS41A1, Revision 1, Operational Schematic Emergency Diesel Generator Systems. Project stage: Other L-11-131, Drawing No. LR-OS041A2, Revision 1, Operational Schematic Emergency Diesel Generator Systems.2008-01-15015 January 2008 Drawing No. LR-OS041A2, Revision 1, Operational Schematic Emergency Diesel Generator Systems. Project stage: Other ML11126A0682008-05-0505 May 2008 Drawing No. LR-M-037E, Revision 28, Piping & Instrument Diagram Clean Liquid Radioactive Waste System. Project stage: Other ML11126A0652008-08-0606 August 2008 Drawing No. LR-M036B, Revision 1, Piping & Instrument Diagram Component Cooling Water System. Project stage: Other ML11126A0592008-10-0909 October 2008 Drawing No. LR-M033A, Revision 1, Piping & Instrument Diagram High Pressure Injection. Project stage: Other ML11126A0632008-10-10010 October 2008 Drawing No. LR-M033B, Revision 1, Piping & Instrument Diagram Decay Heat Train 1. Project stage: Other ML11126A0702008-10-10010 October 2008 Drawing No. LR-M033C, Revision 1, Piping & Instrument Diagram Decay Heat Train 2. Project stage: Other ML11126A0742008-11-0606 November 2008 Drawing No. LR-M043, Revision 1, Piping & Instrument Diagram Auxiliary Building Chilled Water System. Project stage: Other ML11126A0832008-12-18018 December 2008 Drawing No. LR-M038C, Revision 2, Piping & Instrument Diagram Gaseous Radioactive Waste System. Job Code 12501 Project stage: Other ML11126A0712009-04-0707 April 2009 Drawing No. LR-M034, Revision 1, Piping & Instrument Diagram Emerg. Core Cooling System Ctmt. Spray & Core Flooding Systems. Project stage: Other ML11126A0892009-04-0707 April 2009 Drawing No. LR-OS002, Revision 1, Operational Schematic Makeup and Purification System. Project stage: Other ML1024505652010-08-27027 August 2010 License Renewal Application and Ohio Coastal Management Program Consistency Certification Project stage: Other ML1104500462011-02-17017 February 2011 Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station - Fire Protection Project stage: RAI ML11126A0792011-02-25025 February 2011 Drawing No. LR-M900A, Revision 0, Instrument Air System Piping Schematic. Project stage: Other ML1104205972011-02-28028 February 2011 Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station - Section 2.4 Project stage: RAI ML1106801722011-03-17017 March 2011 Request for Additional Information on the Reactor Vessel Surveillance Aging Management Program, Time-Limited Aging Analyses for Neutron Embrittlement of the Rv and Internals, and Other TLAAs for the Review of the Davis-Besse Nuclear Power S Project stage: RAI ML1107007322011-03-18018 March 2011 Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station-Section 2.2 & 2.3 Project stage: RAI L-11-078, Reply to Request for Additional Information for the Review of License Renewal Application (TAC ME4640) Amendment No. 12011-03-18018 March 2011 Reply to Request for Additional Information for the Review of License Renewal Application (TAC ME4640) Amendment No. 1 Project stage: Response to RAI ML11068A0002011-03-21021 March 2011 Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station - Section 4.7 (TAC Number ME4640) Project stage: RAI L-11-079, Reply to Request for Additional Information for the Review of the License Renewal Application2011-03-23023 March 2011 Reply to Request for Additional Information for the Review of the License Renewal Application Project stage: Response to RAI L-11-089, Reply to Request for Additional Information for the Review License Renewal Application2011-03-23023 March 2011 Reply to Request for Additional Information for the Review License Renewal Application Project stage: Response to RAI ML1108206242011-03-30030 March 2011 Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station-Section 2.1 (Tac No. ME4640) Project stage: RAI ML1109002952011-03-31031 March 2011 Safety Evaluation Report Related to the License Renewal of Salem Nuclear Generating Station Project stage: Approval ML1108204902011-04-0505 April 2011 Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station - Batch 1 Project stage: RAI ML11110A0932011-04-15015 April 2011 Drawing No. M-037D, Rev. 21, Clean Liquid Radioactive Waste System Project stage: Other ML11110A1072011-04-15015 April 2011 Drawing No. M-045, Rev. 56, Chemical Addition Systems Project stage: Other ML11110A1062011-04-15015 April 2011 Drawing No. M-042C, Rev. 33, Sampling System Sh. 3 Project stage: Other ML11110A1052011-04-15015 April 2011 Drawing No. M-040A, Rev. 76, Reactor Coolant System Details Project stage: Other ML11110A0952011-04-15015 April 2011 Drawing No. M-039B, Rev. 18, Miscellaneous Liquid Radioactive Waste Project stage: Other ML11110A0942011-04-15015 April 2011 Drawing No. M-039A, Rev. 33, Miscellaneous Liquid Radioactive Waste Project stage: Other ML11110A0922011-04-15015 April 2011 Drawing No. M-037C, Rev. 30, Clean Liquid Radioactive Waste System Project stage: Other L-11-114, Drawing No. M-042B, Rev. 35, Sampling System Sh. 2 Local Grab Samples2011-04-15015 April 2011 Drawing No. M-042B, Rev. 35, Sampling System Sh. 2 Local Grab Samples Project stage: Other L-11-107, Reply to Request for Additional Information on Reactor Vessel Surveillance Aging Management Program & Time-Limited Aging Analyses for Neutron Embrittlement for Review of License Renewal Application & License Renewal Application...2011-04-15015 April 2011 Reply to Request for Additional Information on Reactor Vessel Surveillance Aging Management Program & Time-Limited Aging Analyses for Neutron Embrittlement for Review of License Renewal Application & License Renewal Application... Project stage: Response to RAI ML11110A0882011-04-15015 April 2011 Reply to Request for Additional Information for the Review of the License Renewal Application, Sections 2.2 & 2.3, License Renewal Application Amendment No. 3, and Revised License Renewal Project stage: Response to RAI ML11110A0912011-04-15015 April 2011 Drawing No. M-011, Rev. 61, Domestic Water System Project stage: Other ML11110A0892011-04-15015 April 2011 Drawing No. M-0060, Rev. 52, Auxiliary Feedwater System Project stage: Other ML1110500912011-04-19019 April 2011 Scoping and Screening Audit Report Regarding the Davis-Besse Nuclear Power Station License Renewal Application Project stage: Other L-11-115, Reply to Request for Additional Information for the Review of the License Renewal Application and License Renewal Application Amendment No. 42011-04-20020 April 2011 Reply to Request for Additional Information for the Review of the License Renewal Application and License Renewal Application Amendment No. 4 Project stage: Response to RAI ML1109807182011-04-20020 April 2011 Request for Additional Information for the Review of the Davis-Bessie Nuclear Power Station - Batch 2 Project stage: RAI ML11126A0362011-04-29029 April 2011 Drawing No. LR-M017D, Revision 1 Piping & Instrument Diagram, Steam Blackout Diesel Generator. Project stage: Other ML11126A0352011-04-29029 April 2011 Drawing No. LR-M017C, Revision 2, Piping & Instrument Diagram, Fuel Oil. Project stage: Other ML11126A0342011-04-29029 April 2011 Drawing No. LR-M017B, Revision 1, Piping & Instrument Diagram, Diesel Generators Air Start. Project stage: Other ML11126A0332011-04-29029 April 2011 Drawing No. LR-M016B, Revision 1, Piping & Instrument Diagram Station Fire Protection System Project stage: Other ML11126A0322011-04-29029 April 2011 Drawing No. LR-M016A, Revision 1, Piping & Instrument Diagram Station Fire Protection System Project stage: Other ML11126A0262011-04-29029 April 2011 Drawing No. LR-M010C, Revision 1, Piping & Instrument Diagram Make-up Water Treatment System Project stage: Other ML11126A0252011-04-29029 April 2011 Drawing No. LR-M010A, Revision 1, Piping & Instrument Diagram Make-Up Water Treatment System Project stage: Other ML11126A0242011-04-29029 April 2011 Drawing No. LR-M009B, Revision 1, Piping & Instrument Diagram Cooling Water System Project stage: Other ML11126A0192011-04-29029 April 2011 Drawing No. LR-M003A, Revision 1, Piping & Instrument Diagram Main Steam and Reheat System. Sheet 1 Project stage: Other ML11126A0452011-04-29029 April 2011 Drawing No. LR-M024H, Revision 1, Piping & Instrument Diagram, No. 2 Main and Auxiliary Turbine Driven Feed Pumps. Project stage: Other 2011-02-25
[Table View] |
|
---|
Category:Letter type:L
MONTHYEARL-23-260, Corrections to the 2022 Combined Annual Radiological Environmental Operating Report and Radioactive Effluent Release Report for the Davis-Besse Nuclear Power Station2023-12-0707 December 2023 Corrections to the 2022 Combined Annual Radiological Environmental Operating Report and Radioactive Effluent Release Report for the Davis-Besse Nuclear Power Station L-23-243, Independent Spent Fuel Storage Installation - Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-12-0606 December 2023 Independent Spent Fuel Storage Installation - Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation L-23-215, Changes to Emergency Plan2023-10-19019 October 2023 Changes to Emergency Plan L-23-205, Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-09-12012 September 2023 Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-172, Quality Assurance Program Manual2023-08-31031 August 2023 Quality Assurance Program Manual L-23-188, Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-08-0707 August 2023 Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-175, Submittal of Fifth Ten Year Inservice Testing Program2023-08-0101 August 2023 Submittal of Fifth Ten Year Inservice Testing Program L-23-034, 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models2023-06-13013 June 2023 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models L-23-135, Response to Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations2023-05-31031 May 2023 Response to Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations L-23-065, Annual Financial Report2023-05-22022 May 2023 Annual Financial Report L-23-131, Readiness for Resumption of NRC Supplemental Inspection2023-05-12012 May 2023 Readiness for Resumption of NRC Supplemental Inspection L-23-101, Combined Annual Radiological Environmental Operating Report and Radioactive Effluent Release Report for the Davis-Besse Nuclear Power Station - 20222023-05-12012 May 2023 Combined Annual Radiological Environmental Operating Report and Radioactive Effluent Release Report for the Davis-Besse Nuclear Power Station - 2022 L-23-092, Occupational Radiation Exposure Report for Year 20222023-04-27027 April 2023 Occupational Radiation Exposure Report for Year 2022 L-23-061, Submittal of the Decommissioning Funding Status Reports2023-03-31031 March 2023 Submittal of the Decommissioning Funding Status Reports L-23-037, and Perry Nuclear Power Plant - Independent Spent Fuel Storage Installation Changes, Tests, and Experiments2023-03-29029 March 2023 and Perry Nuclear Power Plant - Independent Spent Fuel Storage Installation Changes, Tests, and Experiments L-23-066, Annual Notification of Property Insurance Coverage2023-03-21021 March 2023 Annual Notification of Property Insurance Coverage L-23-059, Response to Apparent Violation in NRC Inspection Report 05000346/2022091; EA 23-0022023-03-0909 March 2023 Response to Apparent Violation in NRC Inspection Report 05000346/2022091; EA 23-002 L-22-212, CFR 50.55a Request RP-5 Regarding Inservice Pump Testing2023-03-0606 March 2023 CFR 50.55a Request RP-5 Regarding Inservice Pump Testing L-23-048, Response to Request for Additional Information Regarding Technical Specification 5.6.6 Steam Generator Tube Inspection 180-Day Report2023-03-0101 March 2023 Response to Request for Additional Information Regarding Technical Specification 5.6.6 Steam Generator Tube Inspection 180-Day Report L-23-057, Energy Harbor Nuclear Corp Retrospective Premium Guarantee2023-02-20020 February 2023 Energy Harbor Nuclear Corp Retrospective Premium Guarantee L-22-253, Submittal of Pressure and Temperature Limits Report, Revision 52023-01-10010 January 2023 Submittal of Pressure and Temperature Limits Report, Revision 5 L-22-284, Request for Notice of Enforcement Discretion for Technical Specification 3.7.9, Ultimate Heat Sink (UHS)2022-12-28028 December 2022 Request for Notice of Enforcement Discretion for Technical Specification 3.7.9, Ultimate Heat Sink (UHS) L-22-211, Technical Specification 5.6.6 Steam Generator Tube Inspection 180-Day Report2022-09-29029 September 2022 Technical Specification 5.6.6 Steam Generator Tube Inspection 180-Day Report L-22-216, Submittal of Pressure and Temperature Limits Report. Revision 42022-09-27027 September 2022 Submittal of Pressure and Temperature Limits Report. Revision 4 L-22-213, Occupational Radiation Exposure Report for Year 2021 - Correction2022-09-23023 September 2022 Occupational Radiation Exposure Report for Year 2021 - Correction L-22-129, Submittal of the Updated Final Safety Analysis Report, Revision 342022-09-20020 September 2022 Submittal of the Updated Final Safety Analysis Report, Revision 34 L-22-194, Submittal of Supplemental Information for the Reanalysis for Protection Against Low Temperature Reactor Coolant System Overpressure Events2022-09-19019 September 2022 Submittal of Supplemental Information for the Reanalysis for Protection Against Low Temperature Reactor Coolant System Overpressure Events L-22-203, Submittal of Evacuation Time Estimates2022-09-12012 September 2022 Submittal of Evacuation Time Estimates L-22-050, Summary of Changes to the Energy Harbor Nuclear Corp. Quality Assurance Program Manual2022-08-0909 August 2022 Summary of Changes to the Energy Harbor Nuclear Corp. Quality Assurance Program Manual L-22-152, Response to Request for Additional Information Regarding a License Amendment Request That Revises the Davis-Besse Nuclear Power Station Emergency Plan2022-07-0505 July 2022 Response to Request for Additional Information Regarding a License Amendment Request That Revises the Davis-Besse Nuclear Power Station Emergency Plan L-22-068, Cycle 22 and Refueling Outage 22 Inservice Inspection Summary Report2022-06-30030 June 2022 Cycle 22 and Refueling Outage 22 Inservice Inspection Summary Report L-22-037, 2021 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models2022-06-30030 June 2022 2021 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models L-22-149, Post Accident Monitoring Report2022-06-23023 June 2022 Post Accident Monitoring Report L-22-153, Readiness for NRC Supplemental Inspection Required for a White Finding2022-06-22022 June 2022 Readiness for NRC Supplemental Inspection Required for a White Finding L-22-098, Withdrawal of Proposed Inservice Inspection Alternative RR-A22022-06-22022 June 2022 Withdrawal of Proposed Inservice Inspection Alternative RR-A2 L-22-136, Steam Generator Tube Circumferential Crack Report - Spring 2022 Refueling Outage2022-06-0707 June 2022 Steam Generator Tube Circumferential Crack Report - Spring 2022 Refueling Outage L-22-102, Report of Facility Changes, Tests, and Experiments2022-05-16016 May 2022 Report of Facility Changes, Tests, and Experiments L-22-092, Combined Annual Radiological Environmental Operating Report and Radiological Effluent Release Report for the Davis-Besse Nuclear Power Station - 20212022-05-16016 May 2022 Combined Annual Radiological Environmental Operating Report and Radiological Effluent Release Report for the Davis-Besse Nuclear Power Station - 2021 L-22-124, Response to Request for Additional Information Regarding License Amendment Request to Revise the Design Basis for the Shield Building2022-05-12012 May 2022 Response to Request for Additional Information Regarding License Amendment Request to Revise the Design Basis for the Shield Building L-22-047, Unit No.1 - Core Operating Limits Report, Cycle 23, Revision O and Revision 12022-05-10010 May 2022 Unit No.1 - Core Operating Limits Report, Cycle 23, Revision O and Revision 1 L-22-127, Readiness for NRC Supplemental Inspection Required for a Greater than Green Finding2022-05-0606 May 2022 Readiness for NRC Supplemental Inspection Required for a Greater than Green Finding L-22-089, Occupational Radiation Exposure Report for Year 20212022-04-12012 April 2022 Occupational Radiation Exposure Report for Year 2021 L-22-056, Energy Harbor Nuclear Corp., Annual Notification of Property Insurance Coverage2022-03-22022 March 2022 Energy Harbor Nuclear Corp., Annual Notification of Property Insurance Coverage L-22-059, Response to Request for Additional Information on Proposed Inservice Test Alternative RP-32022-03-21021 March 2022 Response to Request for Additional Information on Proposed Inservice Test Alternative RP-3 L-22-074, Response to Regulatory Issue Summary 2022-01, Preparation and Scheduling of Operator Licensing Examinations2022-03-15015 March 2022 Response to Regulatory Issue Summary 2022-01, Preparation and Scheduling of Operator Licensing Examinations L-22-061, Ile Post Exam Letter L-22-0612022-02-24024 February 2022 Ile Post Exam Letter L-22-061 L-22-023, Retrospective Premium Guarantee2022-02-17017 February 2022 Retrospective Premium Guarantee L-21-266, Response to Request for Additional Information on Proposed Inservice Inspection Alternative RR-A22022-01-27027 January 2022 Response to Request for Additional Information on Proposed Inservice Inspection Alternative RR-A2 L-20-289, Emergency Plan Amendment Request2022-01-19019 January 2022 Emergency Plan Amendment Request L-21-290, Response to NRC Inspection Report 05000346/2021091, EA-21-1762021-12-21021 December 2021 Response to NRC Inspection Report 05000346/2021091, EA-21-176 2023-09-12
[Table view] |
Text
FENOC 0E-% 5501 North State Route 2 FirstEnergyNuclear Operating Company Oak Harbor,Ohio 43449 Barry S. Allen 419-321-7676 Vice President- Nuclear Fax. 419-321-7582 May 25, 2012 L-12-185 10 CFR 54 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001
SUBJECT:
Davis-Besse Nuclear Power Station, Unit No. 1 Docket No. 50-346, License Number NPF-3 Supplemental Reply to Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station, Unit No. 1, License Renewal Application (TAC No. ME4640) and License Renewal Application Amendment No. 26 By letter dated August 27, 2010 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML102450565), FirstEnergy Nuclear Operating Company (FENOC) submitted an application pursuant to Title 10 of the Code of Federal Regulations, Part 54 for renewal of Operating License NPF-3 for the Davis-Besse Nuclear Power Station, Unit No. 1 (DBNPS). By letter dated August 11, 2011 (ML11216A236), the Nuclear Regulatory Commission (NRC) issued request for additional information (RAI) 4.3.2.3.2 (Supplement), to complete its review of the License Renewal Application (LRA). By letter dated October 7, 2011 (ML11285A064),
FENOC responded to the RAI by providing a commitment to perform a fatigue evaluation of selected Class 1 valves and submit an amendment to the LRA.
The actions described in the commitment have been completed. The Attachment provides a supplemental response to NRC RAI 4.3.2.3.2 (Supplement), including a description of the Class 1 valve fatigue evaluations performed and results obtained. The NRC request is shown in bold text followed by the FENOC response.
The Enclosure provides Amendment No. 26 to the DBNPS LRA.
Davis-Besse Nuclear Power Station, Unit No. 1 L-1 2-185 Page 2 There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Mr. Clifford I. Custer, Fleet License Renewal Project Manager, at 724-682-7139.
I declare under penalty of perjury that the foregoing is true and correct. Executed on May_2, 2012.
Sincerely, Barry S en
Attachment:
Supplemental Reply to Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station, Unit No. 1 (DBNPS), License Renewal Application, Section 4.3.2
Enclosure:
Amendment No. 26 to the DBNPS License Renewal Application cc: NRC DLR Project Manager NRC Region III Administrator cc: w/o Attachment or Enclosure NRC DLR Director NRR DORL Project Manager NRC Resident Inspector Utility Radiological Safety Board
Attachment L-12-185 Supplemental Reply to Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station, Unit No. 1 (DBNPS), License Renewal Application, Section 4.3.2 Page 1 of 3 Section 4.3.2 Question RAI 4.3.2.3.2 (Supplement)
Background:
By letter dated June 22, 2011, the applicant responded to RAI 4.1-1 regarding cumulative usage factor (CUF) or It fatigue analyses for Class 1 valves. In its response to RAI 4.1-1, Request 1, Part A, the applicant identified 12 large bore Class 1 valves (i.e., valves with nominal pipe sizes in excess of 4-inches) that should have received CUF or It fatigue analyses in accordance with the design codes (i.e., 1971 or more recent Editions of the ASME Code Section III, or the 1968 Edition of the Draft ASME Pump and Valve Code for Nuclear Power Plants).
The applicant provided Commitment No. 46 to complete the following, prior to April 22, 2015:
FENOC commits to perform a fatigue evaluation in accordance with the requirements of the ASME Code of record for the Davis-Besse Class 1 valves that are greater than 4 inches nominal pipe size. The applicable valve identification numbers are CF28, CF29, CF30, CF31, DH76, DH77, DH11, DH12, DHIA, DHIB, DH21, and DH23.
LRA Section 4.3.2.3.2, as amended by letter dated June 22, 2011, states that the fatigue analyses for these 12 referenced large bore Class I valves are as TLAAs and are dispositioned in accordance with Title 10 of the Code of Federal Regulations 54.21(c)(1)(iii), that the effects of fatigue on Class 1 valves greater than 4 inches diameter nominal pipe size will be managed for the period of extended operation by the Fatigue Monitoring Program. LRA Section 4.3.2.3.2 also states that the issue with the missing CUF or It calculations for the 12 referenced large bore Class 1 valves has been entered into the applicant's Corrective Actions Program.
Issue:
The information provided by the applicant in letter of June 22, 2011, did not provide information regarding whether the applicant had any ASME Code,Section III NB-3222.4(d) fatigue waiver assessments (or equivalent waiver assessments permitted by the 1968 Draft ASME Pump and Valve Code) for the 12 large bore Class 1 valves referenced in Commitment No. 46. Therefore, the
Attachment L-12-185 Page 2 of 3 staff requests additional information regarding whether fatigue calculations are required for these valves.
The staff is concerned that without the CUF or It analyses or an appropriate fatigue waiver or exemption for these 12 large bore Class 1 valves, the staff would not be able to evaluate whether the aging effects will be appropriately managed by the commitment.
Request:
Provide justification for not having the analyses for staff review as part of the LRA, or provide your appropriate fatigue waiver or fatigue exemption bases for not having such analyses.
RESPONSE RAI 4.3.2.3.2 (Supplement)
In response to RAI 4.3.2.3.2 (Supplement) submitted by letter dated October 7, 2011 (ML11285A064), FENOC provided the following commitment:
FENOC will perform a fatigue evaluation in accordance with the requirements of the ASME Code of record for the Davis-Besse Class 1 valves that are greater than 4 inches diameter nominal pipe size. The applicable valve identification numbers are CF28, CF29, CF30, CF31, DH76, DH77, DH11, DH12, DH1A, DH1B, DH21 and DH23. LRA Sections 4.3.2.3.2 and A.2.3.2.13, both titled "Class 1 Valves Fatigue," will be revised to include the results of the fatigue evaluations, and these changes will be submitted as an amendment to the Davis Besse LRA no later than May 31, 2012.
The actions described in the commitment have been completed. This supplemental response to RAI 4.3.2.3.2 (Supplement) addresses the fatigue evaluation results of the Davis-Besse Class 1 valves that are greater than 4 inches diameter nominal pipe size (valve identification numbers CF28, CF29, CF30, CF31, DH76, DH77, DH1 1, DH12, DHIA, DH1B, DH21 and DH23) and the associated changes to License Renewal Application (LRA) Sections 4.3.2.3.2 and A.2.3.2.13.
Fatigue analyses were prepared for the subject Class 1 valves in accordance with paragraph NB-3550 of ASME Code Section III, 1974 Edition with Addenda through the Summer of 1976, and were reconciled to the valve construction code year. The cumulative usage factors (CUFs) calculated for the subject Class 1 valves are based on nuclear steam supply system design transients and, as shown in the table below, are less than 1.0. The number of occurrences of design transients is tracked by the Fatigue Monitoring Program to ensure that action is taken before the design cycles are reached.
Therefore, the effects of fatigue on Class 1 valves greater than 4 inches diameter
Attachment L-12-185 Page 3 of 3 nominal pipe size (NPS) will be managed for the period of extended operation by the Fatigue Monitoring Program in accordance with 10 CFR 54.21(c)(1)(iii).
Size Construction Maximum Valve ID (dia. NPS) Code Year CUF
& Type CF28 CF29 14 inch 1971 Core Flood -
w/Addenda thru core flood tank discharge line 0.02839 CF30 Winter 1972 stop check isolation valve CF31 DHI 1 12 inch 1968 Reactor Coolant System to Decay Heat- 0.14594 gate Draft Pump & containment isolation valve DH12 gValve DH21 8 inch 1971 Reactor Coolant System to Decay Heat -
w/Addenda thru containment isolation valve bypass line 0.02732 DH23 gate Winter 1972 isolation valve DH76 10 inch 1971 Low Pressure Injection to w/Addenda thru Reactor Coolant System - 0.14099 DH77 Winter 1972 stop check isolation valve DH1A 10 inch 1968 Low Pressure Injection -
gate Draft Pump & outside containment isolation valve 0.18261 DH1Bgt Valve LRA Sections 4.3.2.3.2 and A.2.3.2.13 are revised to include the results of the fatigue evaluations.
See the Enclosure to this letter for the revision to the DBNPS LRA.
Enclosure Davis-Besse Nuclear Power Station, Unit No. 1 (DBNPS)
Letter L-12-185 Amendment No. 26 to the DBNPS License Renewal Application Page 1 of 5 License Renewal Application Sections Affected Section 4.3.2.3.2 Section A.2.3.2.13 The Enclosure identifies the change to the License Renewal Application (LRA) by Affected LRA Section, LRA Page No., and Affected Paragraph and Sentence. The count for the affected paragraph, sentence, bullet, etc. starts at the beginning of the affected Section or at the top of the affected page, as appropriate. Below each section the reason for the change is identified, and the sentence affected is printed in italics with deleted text hined-ou and added text underlined.
Enclosure L-12-185 Page 2 of 5 Affected LRA Section LRA Page No. Affected Paragraph and Sentence 4.3.2.3.2 Pages 4.3-16 Entire Section and 4.3-17 In response to RAI 4.3.2.3.2 (Supplement), LRA Section 4.3.2.3.2, "Class 1 Valves Fatigue," previously revised by FENOC letter dated October 7, 2011 (ML1I1285A064), is replaced in its entirety, to read as follows:
4.3.2.3.2 Class 1 Valves Fatigue The ASME Code requires a fatigue evaluation for Class 1 valves greater than 4 inches diameter nominal pipe size or for valves less than or equal to 4 inches in nominal pipe size if specified by the owner's design specification. The Davis-Besse purchasing specifications did not require a fatigue analysis for Class 1 valves less than or equal to 4 inches in nominal pipe size. Therefore, only valves greater than 4 inches diameter nominal pipe size require a fatigue analysis. Piping and instrumentation diagrams (P&IDs) were reviewed to identify Class 1 valves of greater than 4 inches diameter nominal pipe size. There were 12 valves of greater than 4 inches diameter nominal pipe size that were identified as a result of this effort.
Fatigue analyses were prepared for the subject Class 1 valves in accordance with paragraph NB-3550 of ASME Code Section III, 1974 Edition with Addenda through the Summer of 1976 and were reconciled to the valve construction code year.
Since ASME Code fatigue analyses evaluate an explicit number and type of thermal and pressure transients that are postulated to envelope the number of occurrences possible during the design life of the plant, these fatigue analyses are time-limited aging analyses (TLAAs) and therefore, are required to be evaluated in accordance with 10 CFR 54.21(c)(1).
The cumulative usage factors calculated for the subject Class 1 valves are based on nuclear steam supply system design transients and, as shown in the table below, are less than 1.0. The number of occurrences of design transients is tracked by the Fatigue Monitoring Program to ensure that action is taken before the design cycles are reached. Therefore, the effects of fatigue on Class 1 valves greater than 4 inches diameter nominal pipe size (NPS) will be managed for the period of extended operation by the Fatigue Monitoring Program.
Enclosure L-12-185 Page 3 of 5 Size Construction Maximum Valve ID (dia. NPS) Code Year Description CUF
& Type CF28 CF29 14 inch 1971 Core Flood -
w/Addenda thru core flood tank discharge line 0.02839 CF30 Winter 1972 stop check isolation valve CF31 Draft1968 Reactor Coolant System to Decay Heat -
Valv containment isolation valve 0.14594 DH12 DH12 gate Valve DH21 8 inch 1971 Reactor Coolant System to Decay Heat -
w/Addenda thru containment isolation valve bypass line 0.02732 DH23 gate Winter 1972 isolation valve DH76 10 inch 1971 Low Pressure Injection to w/Addenda thru Reactor Coolant System - 0.14099 DH77 Winter 1972 stop check isolation valve DDrf1A 10 inch 1968 Low Pressure Injection -
DH-11B at gae Pump &
DraftValve outside containment isolation valve 0.18261 Disposition: 10 CFR 54.21(c)(1)(iii) The effects of fatigue on Class I valves greater than 4 inches diameter nominal pipe size will be managed for the period of extended operation by the Fatigue Monitoring Program.
Enclosure L-1 2-185 Page 4 of 5 Affected LRA Section LRA Paqe No. Affected Paragraph and Sentence A.2.3.2.13 Page A-41 Entire Section In response to RAI 4.3.2.3.2 (Supplement), LRA Section A.2.3.2.13, "Class 1 Valves Fatigue," previously revised by FENOC letter dated October 7, 2011 (ML1I1285A064), is replaced in its entirety, to read as follows:
A.2.3.2.13 Class 1 Valves Fatigue The ASME Code requires a fatigue evaluation for Class 1 valves greater than 4 inches diameter nominal pipe size or for valves less than or equal to 4 inches in nominal pipe size if specified by the owner's design specification. The Davis-Besse purchasing specifications did not require a fatigue analysis for Class 1 valves less than or equal to 4 inches in nominal pipe size. Therefore, only valves greater than 4 inches diameter nominal pipe size require a fatigue analysis. Piping and instrumentation diagrams (P&IDs) were reviewed to identify Class 1 valves of greater than 4 inches diameter nominal pipe size. There were 12 valves of greater than 4 inches diameter nominal pipe size that were identified as a result of this effort.
Fatigue analyses were prepared for the subject Class 1 valves in accordance with paragraph NB-3550 of ASME Code Section III, 1974 Edition with Addenda through the Summer of 1976 and were reconciled to the valve construction code year.
Since ASME Code fatigue analyses evaluate an explicit number and type of thermal and pressure transients that are postulated to envelope the number of occurrences possible during the design life of the plant, these fatigue analyses are time-limited aging analyses (TLAAs) and therefore, are required to be evaluated in accordance with 10 CFR 54.21(c)(1).
The cumulative usage factors calculated for the subject Class 1 valves are based on nuclear steam supply system design transients and, as shown in the table below, are less than 1.0. The number of occurrences of design transients is tracked by the Fatigue Monitoring Program to ensure that action is taken before the design cycles are reached. Therefore, the effects of fatigue on Class 1 valves greater than 4 inches diameter nominal pipe size (NPS) will be managed for the period of extended operation by the Fatigue Monitoring Program in accordance with 10 CFR 54.21 (c)(1)(iii).
Enclosure L-12-185 Page 5 of 5 size Construction Maximum Valve ID (dia. NPS) Code Year Description CUF
& Type CF28 CF29 14 inch 1971 Core Flood -
w/Addenda thru core flood tank discharge line 0.02839 CF30 Winter 1972 stop check isolation valve CF31 Draft1968 Reactor Coolant System to Decay Heat -
DH12 gaeValve Draft Pump & containment isolation valve 0.14594 DH1g DH21 8 inch 1971 Reactor Coolant System to Decay Heat -
w/Addenda thru containment isolation valve bypass line 0.02732 DH23 gate Winter 1972 isolation valve DH76 10 inch 1971 Low Pressure Injection to w/Addenda thru Reactor Coolant System - 0.14099 DH77 Winter 1972 stop check isolation valve DH1A 10 inch 1968 Low Pressure Injection -
DH-11B at Pump & III outside containment isolation valve DraftValve 0.18261 Dae