MONTHYEARML11126A0842003-01-22022 January 2003 Drawing No. LR-M039A, Revision 3, Piping & Instrument Diagram Miscellaneous Liquid Radioactive Waste. Job Code 12501 Project stage: Other ML11126A0762003-01-22022 January 2003 Drawing No. LR-M047, Revision 1, Piping & Instrument Diagram Radwaste Drumming Station Project stage: Other ML11126A0552003-08-12012 August 2003 Drawing No. LR-M030B, Revision 1, Reactor Coolant System Instrumentation Project stage: Other ML11126A0862005-08-23023 August 2005 Drawing No. LR-M040D, Revision 2, Piping & Instrument Diagram Reactor Coolant Pump & Motor. Job Code 12501 Project stage: Other ML11126A0882008-01-12012 January 2008 Drawing No. LR-M041B, Revision 1, Piping & Instrument Diagram Primary Service Water System. Job Code 12501 Project stage: Other ML11126A0902008-01-15015 January 2008 Drawing No. LR-OS41A1, Revision 1, Operational Schematic Emergency Diesel Generator Systems Project stage: Other L-11-131, Drawing No. LR-OS041A2, Revision 1, Operational Schematic Emergency Diesel Generator Systems2008-01-15015 January 2008 Drawing No. LR-OS041A2, Revision 1, Operational Schematic Emergency Diesel Generator Systems Project stage: Other ML11126A0682008-05-0505 May 2008 Drawing No. LR-M-037E, Revision 28, Piping & Instrument Diagram Clean Liquid Radioactive Waste System Project stage: Other ML11126A0652008-08-0606 August 2008 Drawing No. LR-M036B, Revision 1, Piping & Instrument Diagram Component Cooling Water System Project stage: Other ML11126A0592008-10-0909 October 2008 Drawing No. LR-M033A, Revision 1, Piping & Instrument Diagram High Pressure Injection Project stage: Other ML11126A0702008-10-10010 October 2008 Drawing No. LR-M033C, Revision 1, Piping & Instrument Diagram Decay Heat Train 2 Project stage: Other ML11126A0632008-10-10010 October 2008 Drawing No. LR-M033B, Revision 1, Piping & Instrument Diagram Decay Heat Train 1 Project stage: Other ML11126A0742008-11-0606 November 2008 Drawing No. LR-M043, Revision 1, Piping & Instrument Diagram Auxiliary Building Chilled Water System Project stage: Other ML11126A0832008-12-18018 December 2008 Drawing No. LR-M038C, Revision 2, Piping & Instrument Diagram Gaseous Radioactive Waste System. Job Code 12501 Project stage: Other ML11126A0892009-04-0707 April 2009 Drawing No. LR-OS002, Revision 1, Operational Schematic Makeup and Purification System Project stage: Other ML11126A0712009-04-0707 April 2009 Drawing No. LR-M034, Revision 1, Piping & Instrument Diagram Emerg. Core Cooling System Ctmt. Spray & Core Flooding Systems Project stage: Other ML1025100842010-09-14014 September 2010 Y20100173 - Grays Engineering and Consulting, Inc. - Letter Aerotest Operations, Inc Project stage: Other ML1104500462011-02-17017 February 2011 Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station - Fire Protection Project stage: RAI L-11-037, Independent Spent Fuel Storage Installation - Changes, Tests, and Experiments2011-02-17017 February 2011 Independent Spent Fuel Storage Installation - Changes, Tests, and Experiments Project stage: Request ML11126A0792011-02-25025 February 2011 Drawing No. LR-M900A, Revision 0, Instrument Air System Piping Schematic Project stage: Other ML1104205972011-02-28028 February 2011 Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station - Section 2.4 Project stage: RAI ML1106801722011-03-17017 March 2011 Request for Additional Information on the Reactor Vessel Surveillance Aging Management Program, Time-Limited Aging Analyses for Neutron Embrittlement of the Rv and Internals, and Other TLAAs for the Review of the Davis-Besse Nuclear Power s Project stage: RAI L-11-078, Reply to Request for Additional Information for the Review of License Renewal Application (TAC ME4640) Amendment No. 12011-03-18018 March 2011 Reply to Request for Additional Information for the Review of License Renewal Application (TAC ME4640) Amendment No. 1 Project stage: Response to RAI ML1107007322011-03-18018 March 2011 Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station-Section 2.2 & 2.3 Project stage: RAI ML11068A0002011-03-21021 March 2011 Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station - Section 4.7 (TAC Number ME4640) Project stage: RAI L-11-089, Reply to Request for Additional Information for the Review License Renewal Application2011-03-23023 March 2011 Reply to Request for Additional Information for the Review License Renewal Application Project stage: Response to RAI L-11-079, Reply to Request for Additional Information for the Review of the License Renewal Application2011-03-23023 March 2011 Reply to Request for Additional Information for the Review of the License Renewal Application Project stage: Response to RAI ML1108206242011-03-30030 March 2011 Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station-Section 2.1 (Tac No. ME4640) Project stage: RAI ML1109002952011-03-31031 March 2011 Safety Evaluation Report Related to the License Renewal of Salem Nuclear Generating Station Project stage: Approval ML1108204902011-04-0505 April 2011 Request for Additional Information for the Review of the Davis-Besse Nuclear Power Station - Batch 1 Project stage: RAI ML11110A0882011-04-15015 April 2011 Reply to Request for Additional Information for the Review of the License Renewal Application, Sections 2.2 & 2.3, License Renewal Application Amendment No. 3, and Revised License Renewal Project stage: Response to RAI L-11-114, Drawing No. M-042B, Rev. 35, Sampling System Sh. 2 Local Grab Samples2011-04-15015 April 2011 Drawing No. M-042B, Rev. 35, Sampling System Sh. 2 Local Grab Samples Project stage: Other L-11-107, Reply to Request for Additional Information on Reactor Vessel Surveillance Aging Management Program & Time-Limited Aging Analyses for Neutron Embrittlement for Review of License Renewal Application & License Renewal Application.2011-04-15015 April 2011 Reply to Request for Additional Information on Reactor Vessel Surveillance Aging Management Program & Time-Limited Aging Analyses for Neutron Embrittlement for Review of License Renewal Application & License Renewal Application. Project stage: Response to RAI ML11110A0892011-04-15015 April 2011 Drawing No. M-0060, Rev. 52, Auxiliary Feedwater System Project stage: Other ML11110A0912011-04-15015 April 2011 Drawing No. M-011, Rev. 61, Domestic Water System Project stage: Other ML11110A0922011-04-15015 April 2011 Drawing No. M-037C, Rev. 30, Clean Liquid Radioactive Waste System Project stage: Other ML11110A0932011-04-15015 April 2011 Drawing No. M-037D, Rev. 21, Clean Liquid Radioactive Waste System Project stage: Other ML11110A0942011-04-15015 April 2011 Drawing No. M-039A, Rev. 33, Miscellaneous Liquid Radioactive Waste Project stage: Other ML11110A0952011-04-15015 April 2011 Drawing No. M-039B, Rev. 18, Miscellaneous Liquid Radioactive Waste Project stage: Other ML11110A1052011-04-15015 April 2011 Drawing No. M-040A, Rev. 76, Reactor Coolant System Details Project stage: Other ML11110A1062011-04-15015 April 2011 Drawing No. M-042C, Rev. 33, Sampling System Sh. 3 Project stage: Other ML11110A1072011-04-15015 April 2011 Drawing No. M-045, Rev. 56, Chemical Addition Systems Project stage: Other ML1110500912011-04-19019 April 2011 Scoping and Screening Audit Report Regarding the Davis-Besse Nuclear Power Station License Renewal Application Project stage: Other L-11-115, Reply to Request for Additional Information for the Review of the License Renewal Application and License Renewal Application Amendment No. 42011-04-20020 April 2011 Reply to Request for Additional Information for the Review of the License Renewal Application and License Renewal Application Amendment No. 4 Project stage: Response to RAI ML1109807182011-04-20020 April 2011 Request for Additional Information for the Review of the Davis-Bessie Nuclear Power Station - Batch 2 Project stage: RAI ML11126A0532011-04-29029 April 2011 Drawing No. LR-M029C, Revision 2, P & Id - HV & A/C Air Flow Diagram, Containment and Penetration Rooms, Sheet 2 Project stage: Other ML11126A0422011-04-29029 April 2011 Drawing No. LR-M019, Revison 1, Piping & Instrument Diagram, Nitrogen Supply System Project stage: Other ML11126A0432011-04-29029 April 2011 Drawing No. LR-M022A, Revision 1, Piping & Instrument Diagram, Main Turbine Gland Steam Seal & Drain System Project stage: Other ML11126A0442011-04-29029 April 2011 Drawing No. LR-M024G, Revision 1, Piping & Instrument Station, No. 1 Main and Auxiliary Turbine Driven Feed Pumps Project stage: Other ML11126A0382011-04-29029 April 2011 Drawing No. LR-M012E, Revision 1, Piping & Instrument Diagram Screen Wash and Cooling Tower Make-up System Project stage: Other 2011-02-17
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 October 9, 2013 Mr. Raymond A. Lieb, Site Vice President FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station Mail Stop A-DB-3080 5501 North State Route 2 Oak Harbor, OH 43449-9760
SUBJECT:
SCHEDULE REVISION FOR SAFETY REVIEW OF THE DAVIS-BESSE NUCLEAR POWER STATION, UNIT 1, LICENSE RENEWAL APPLICATION (TAG NO ME4640)
Dear Mr. Lieb:
By letter dated August 27, 2010, FirstEnergy Nuclear Operating Company (FENOC) submitted an application pursuant to Title 10 of the Code of Federal Regulations (1 0 CFR)
Part 51 and 10 CFR Part 54, to renew operating license NPF-003 for the Davis-Besse Nuclear Power Station, Unit 1 (Davis-Besse), for review by the U.S. Nuclear Regulatory Commission (NRC) staff. This letter is to inform you of a change in the safety review schedule for the Davis-Besse license renewal review.
Enclosed is the NRC staff's revised safety review schedule for the Davis-Besse license renewal application (LRA). The schedule has been updated to reflect changes in the ACRS second subcommittee meeting and the final ACRS full committee meeting on the SER and includes to-be-determined (TBD) milestones. By letter dated October 8, 2013, FENOC requested to postpone the schedule in order to allow sufficient time to adequately assess the new cracks that were identified as part of routine inspections at the concrete shield building. In addition, this would also allow the identification of the potential impacts, if any, to the LRA.
The NRC will continue to follow established review procedures and the enclosed schedule to complete the reviews required by 10 CFR Part 54. For questions on the revised safety schedule, please contact Mr. Juan Uribe, Project Manager for the Davis-Besse LRA safety review, by telephone at 301-415-3809 or by e-mail at juan.uribe@nrc.gov.
Docket No. 50-346
Enclosure:
Revised Safety Review Schedule cc w/encl: Listserv
. i~C 1
fi Ohn W Lubinsk~
Division of License Renewal Office of Nuclear Reactor Regulation
October 9, 2013 Mr. Raymond A. Lieb, Site Vice President FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station Mail Stop A-DB-3080 5501 North State Route 2 Oak Harbor, OH 43449-9760
SUBJECT:
SCHEDULE REVISION FOR SAFETY REVIEW OF THE DAVIS-BESSE NUCLEAR POWER STATION, UNIT 1, LICENSE RENEWAL APPLICATION (TAC NO ME4640)
Dear Mr. Lieb:
By letter dated August 27, 2010, FirstEnergy Nuclear Operating Company (FENOC) submitted an application pursuant to Title 10 of the Code of Federal Regulations (1 0 CFR)
Part 51 and 10 CFR Part 54, to renew operating license NPF-003 for the Davis-Besse Nuclear Power Station, Unit 1 (Davis-Besse), for review by the U.S. Nuclear Regulatory Commission (NRC) staff. This letter is to inform you of a change in the safety review schedule for the Davis-Besse license renewal review.
Enclosed is the NRC staff's revised safety review schedule for the Davis-Besse license renewal application (LRA). The schedule has been updated to reflect changes in the ACRS second subcommittee meeting and the final ACRS full committee meeting on the SER and includes to-be-determined (TBD) milestones. By letter dated October 8, 2013, FENOC requested to postpone the schedule in order to allow sufficient time to adequately assess the new cracks that were identified as part of routine inspections at the concrete shield building. In addition, this would also allow the identification of the potential impacts, if any, to the LRA.
The NRC will continue to follow established review procedures and the enclosed schedule to complete the reviews required by 10 CFR Part 54. For questions on the revised safety schedule, please contact Mr. Juan Uribe, Project Manager for the Davis-Besse LRA safety review, by telephone at 301-415-3809 or by e-mail at juan.uribe@nrc.gov.
Docket No. 50-346
Enclosure:
Revised Safety Review Schedule cc w/encl: Listserv ADAMS Accession No.* ML13281A845 OFFICE PM:DLR/RPB BC:DLR/RPB1 NAME JUri be YDiaz DATE 10/9/13 10/9/13 Sincerely, IRA by Melanie Galloway for/
John W. Lubinski, Director Division of License Renewal Office of Nuclear Reactor Regulation LA: DLR/RPB2 D:DLR YEdmonds JLubinski 10/9/13 10/9/13
DAVIS-BESSE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION UPDATED SAFETY REVIEW SCHEDULE Milestones Schedule Date Receive license renewal application (LRA) 08/30/2010 Publish Federal Register Notice (FRN) -LRA receipt and 09/17/2010 availability Publish FRN -LRA acceptability and opportunity for hearing 10/20/2010 Public Meeting -license renewal process and environmental 11/04/2010 seeping Deadline for filing hearing requests and petitions for intervention 12/24/2010 Audit -seeping and screening methodology 01/24/2011 Audit -aging management programs (AMPs) 02/14/2011 Inspection -seeping, screening, and AMPs 04/2011 Safety Requests for Additional Information (RAis) -Issued 04/29/2011 Safety RAis -First Round Responses Received 05/30/2011 Issue draft supplemental environmental impact statement 10/2013 (SEIS)
Public Meeting-draft SEIS 11/2013 End of comment period for the draft SEIS 12/2013 Issue safety evaluation report (SER) with open items(s) 7/2012 Advisory Committee on Reactor Safeguards (ACRS) 09/19/2012 subcommittee meeting on SER with open item(s)
Issue SER 9/2013 ACRS second subcommittee meeting on SER TBD*
ACRS full committee meeting on SER TBD*
Issue final SEIS 6/2014 NRR Decision TBD*
Commission Decision (hearing pending)
TBD*
Actual Date 08/30/2010 09/20/2010 10/25/2010 11/04/2010 12/24/2010 01/24/2011 02/14/2011 04/25/2011 04/29/2011 05/30/2011 07/31/2012 09/19/2012 09/03/2013 ENCLOSURE
SUBJECT:
SCHEDULE REVISION FOR SAFETY REVIEW OF THE DAVIS-BESSE NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION (LRA)
(TAC NO ME4640)
DISTRIBUTION:
E-MAIL:
PUBLIC RidsNrrDir Resource RidsNrrDirRpb1 Resource RidsNrrDirRpb2 Resource RidsNrrDirRarb Resource RidsNrrDirRapb Resource RidsNrrDirRasb Resource RidsNrrDirRerb Resource RidsNrrDirRpob Resource RidsNrrDraApla Resource EKeegan SCuadrado JUri be YDiaz DWrona BHarris, OGC EBrown A Wang MMahoney DMclntyre, OPA VMitlyng,OPA TRiley,OCA EWilliamson, OGC RRihm, EDO JCameron, Rill