05000263/LER-1992-012, Forwards LER 92-012-01 Initially Re Failure to Include Manual Valves in Section XI Testing.Results of Review & Other ASME Section XI Program Discrepancies,Noted in Insp Rept 50-263/92-10 Warranted Rev to LER

From kanterella
Jump to navigation Jump to search
Forwards LER 92-012-01 Initially Re Failure to Include Manual Valves in Section XI Testing.Results of Review & Other ASME Section XI Program Discrepancies,Noted in Insp Rept 50-263/92-10 Warranted Rev to LER
ML20127L376
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 11/19/1992
From: Parker T
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20127L381 List:
References
NUDOCS 9211240070
Download: ML20127L376 (1)


LER-2092-012, Forwards LER 92-012-01 Initially Re Failure to Include Manual Valves in Section XI Testing.Results of Review & Other ASME Section XI Program Discrepancies,Noted in Insp Rept 50-263/92-10 Warranted Rev to LER
Event date:
Report date:
2632092012R00 - NRC Website

text

- - - _ _ . . _ _ _ . _ - _ _ _ _

Northem States Power Company 414 Wicollet Mall Minneapolis, Minnesota 55401 1927 Telephone (612) 330 550G November 19, 1992 Report Required by 10 CFR Part 50, Section 50,73 U.S. Nuclear Regulatory Cammission Attn: Document Control Desk Washington, DC 20555 -

MONTICELLO NUCLEAR GENERATING PLANT Docket No. 50-263 License No. DPR-22 Failure to Include Manual Valves in Section XI Testinr. Caused by Interpretation of ASME ReautremenLg c

The supplemental Licensee Ev nt Report for this occurrence is attached. The original report for this event (Monticello Licensee Event Report 92-012 00, dated September 23, 1992) identified an action to be completed that involved a review of our ASME Section XI Inservice Testing Program to determine if thers were other

_ components that should have been included in the program but were not. The results of this review, as well as other ASME Section XI prograr discrepancies identified in NRC Inspection Report 50-263/92010, dat4:d September 30,199', were significant enough to warrant revision of the original event reporu.

Please contact us if you require further information.

4

%A iL/

Thomas Parker Manager Nuc1 car Support Services

, c: Regional Administrator - III NRC Sr Resident Inspector, NRC NRR Project Manager, NRC State of Minnesota, Attu: Kris Sanda Attachment 9211240070 921119 /

PDR ADOCK 05000263 /

S PDR f \

).

- _ - _ - _ - - - - - - _ - - - _ - - - - - --- - - -