ML20135C091

From kanterella
Revision as of 08:34, 20 June 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Proprietary Response to Questions 5-10 in NRC 841217 Evaluation of Spds,Finding Program Implementation Acceptable Contingent Upon Addressing Listed Concerns.Encl Withheld
ML20135C091
Person / Time
Site: Yankee Rowe
Issue date: 09/03/1985
From: Papanic G
YANKEE ATOMIC ELECTRIC CO.
To: Zwolinski J
Office of Nuclear Reactor Regulation
Shared Package
ML19269B666 List:
References
FYR-85-95, NUDOCS 8509110297
Download: ML20135C091 (1)


Text

-

YANKEE ATOMIC ELECTRIC COMPANY Te'""o"o (6 ") 8 ' -8 '00 TWX 710-380-7619 1671 Worcester Road, Framingham, Massachusetts 01701 2.C.2.1 d.,Qrg , FYR 85-95

~ . -

September 3, 1985 United States Nuclear Regulatory Commission Washington, DC 20555 Attention: Mr. John A. Zwolinski, Chief Operating Reactors Branch No. 5 Division of Licensing

References:

(a) License No. DPR-3 (Docket No. 50-29)

(b) USNRC Letter to YAEC, dated December 17, 1984 (c) YAEC Letter to USNRC, dated April 8, 1985

Subject:

Safety Parameter Display System

Dear Sir:

Reference (b) submitted the staff's evaluation of the Yankee Safety Parameter Display System (SPDS). This evaluation concluded that continued implamentation of our SPDS program was acceptable provided that certain concerns were addressed. Our response to the staff's Questions 1-4 is contained in Reference (c).

This letter provides our response to the remaining Questions 5-10 in Reference (b). Attachment (A) is a letter from Technology For Energy Corporation to Yankee providing answers to Questions 5, 6, 7, 8 and 10.

Attachment (B), containing two reports, answers Question 9.

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY (L h C. Papanic, Jr.

Senior Project Engineer - Licensing GP/dps

\

id] scSS I .

0 9tgo $ e ip F

l l