e Lw 580 Main Street, Bolton, Massachusetts 017401398 August 17, 1990 BYR-90-116
. United States Nuclear Regulatory Consnission
= Attention: Document Control Desk
'i Weshington,'DC 20555
.i References-(a) License No. DPR-3 (Docket No. 50-29)
Y l
Subject:
Augmented Pressurizer Vessel Exam
.g Dear Sirs l
Yankee performed an automated ultrasonic inspection of the pressurizer vessel cladding interface'at Yankee Nuclear Power Station (YNPS) during the 1990' refueling outage. This work was'a continuation of the surveillances begun.in 1965. TheEinspection utilized a 60' focused longitudinal wave transducer specifically designed to examine the vessel's inside diameter. The results of the inspection continue to indicate no evidence.of any cladding indication extending into the base material of the vessel.
Yankee intends to' periodically perform this inspection using the present or'~similar automated equipment. The Inservice Inspection Program for YNPS will'be modified:to' include a twice per ten-year interval inspection
(
requirement.
~l We trust that you will find this information satisfactory however, if you-have any-questions, please contact us.
~
1 b
Very truly yours, YANKEE ATOMIC CTRIC COMPANY R
Geor Papanic, Jr.
Senior Project' Engineer Licensing GP/tlp/WPP72/90 cc: USNRC Region I USNRC Resident Inspector, YNPS Mr.11. Kaplan, USNRC Region I t
i i
00103 9008290056-900017 S
l 0 O -
ADOCK 05000029 y; PDR.
PNV ts c,e