Final Deficiency Rept Re Cracked Welds in Containment Annular Steel End Connections.Initially Reported on 820910. Metallurgical Investigation Performed,Welding & Installation Procedure Revised & Cracked Connections Replaced
ML20069H068
Person / Time
Site: Seabrook  NextEra Energy icon.png
Issue date: 10/12/1982
From: Devincentis J
PUBLIC SERVICE CO. OF NEW HAMPSHIRE, YANKEE ATOMIC ELECTRIC CO.
To: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
10CFR-050.55E, 10CFR-50.55E, SBN-340, NUDOCS 8210190363