LER 81-004/01T-0:on 810209,main Steam Radiation Monitor 111 Signal Fluctuated,Causing Multiple Half Scrams.Caused by Loose detector-to-cable Connector.Connector Tightened
ML18037A328
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 02/23/1981
From: HARRISON P
NIAGARA MOHAWK POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML17053C373 List:
References
LER-81-004-01T, LER-81-4-1T, NUDOCS 8103030757