05000220/LER-1981-046-04, /04T-0:on 810922,review of 810813 & 14 ETS Semiannual Samples of Cladophora Showed Co-60 & Nb-95 at Level of 10 Times Control Value.Probably Caused by Liquid Effluent Discharge & Oct 1980 Chinese Weapons Test

From kanterella
(Redirected from ML20011A485)
Jump to navigation Jump to search
/04T-0:on 810922,review of 810813 & 14 ETS Semiannual Samples of Cladophora Showed Co-60 & Nb-95 at Level of 10 Times Control Value.Probably Caused by Liquid Effluent Discharge & Oct 1980 Chinese Weapons Test
ML20011A485
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 09/30/1981
From: Mclaughlin K
NIAGARA MOHAWK POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20011A481 List:
References
LER-81-046-04T, LER-81-46-4T, NUDOCS 8110130472
Download: ML20011A485 (1)


LER-1981-046, /04T-0:on 810922,review of 810813 & 14 ETS Semiannual Samples of Cladophora Showed Co-60 & Nb-95 at Level of 10 Times Control Value.Probably Caused by Liquid Effluent Discharge & Oct 1980 Chinese Weapons Test
Event date:
Report date:
2201981046R04 - NRC Website

text

_

(7 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT CR TYPE ALL REQUIRED INFORMATl!N) 1 6

L]

l o l i l I N I Y ! N ! 51 l P l 1 lh! 0 l 0 l-l 0 l0 l0 l0l0l-l0l0l@l4l1l1 l1 l1 lh!

l l@

7 8 9 LICENSEF CODE 14 16 LICENSE NUMBER 2h 2b LICENSE TYPE J 67 CAT ba i

CON'T i

a lolil

= LU@l o i s 10 10 10 I: !2 10 l@l 01912 l 2 l s l 1 i@l 0 l 9 l 3 l 0 l 8 l1 l@

j 7

8 60 61 DOCKET NUMBER 68 69 "T D A'.

74 7b REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h 1

Io l2l l On Aucust 13 and 14. Envi ronmenta1 Technical Specificatior semi-annual samples of I

l 0 l 3 ! l Cladophora, an algae were collected on the north shore of the James A. Fit: Patrick l

lojal l site.

The samples were found to contain Co-60 and Nb-95 in concentrations that were I

oisl l slightly higher than the Environmental Tech. Spec. reporting level of 10 times the

]

1O is l l contr31 value.

Sampics collected at the Nine 51ile Point site showed Nb-95 detected I

l o [ 7 ] [ nt exactly 10 times the control value.

The samples were recounted and the same resultsl I

l 0 ls l l were found.

Safety consequences were minimal.

I 7

8 9 8

SYSTEM

CAUSE

CAUSE

. COMPONENT CODE SUBCODE SUBCODE COMP.

VALVE CODE CODE SUBCODE Ioisl 1: I : lO LLj@ l x l@ l I l 21 : I : I: I: 18 L:J@ L1] @

7 8

9 10 11 12 13 18 19 20 SEGUENTI AL oCCU R R E NCE REPORT fiE VISION LE R RO EVENT YE AR REPORT NO.

CODE TYPE NO.

h REQPT l8 l} l l-l l 0l 4l 6l y

l0 l4 l W

l-l l0l U

_ 21 22 23 24 26 27 28 29 JU 31 32 ACTION. FUT w4E EFFECT SHUTDOWN ATTACHMENT NP R D-4 PRIME COJP.

COMPONENT TAKEN ACTION ON PLANT YETHOD HOURS SUBvlTTED FORM bub.

SUPPLIE H MANUFACTURER lX]Q]Xl@

l2l@

lZ l@

l 0l 0l 0l l

W@

l N ]@

lZ l@

l: l 9l 9l 9l 33 34 35 36 3

40 41 42 43 44 di CAUSE DESCRIPTION AND CORRECTIVE ACTIONS l i l o l l The most probabic source of Co-60 is the liquid effluent discharne from both th;.

I l i l ij l Nine blile Point Unit #1 and the Fi.: Patrick plants.

All discharnes have been well I

g ; within the allowable Technical Specification limits.

The most _ probable source of the l

[,,3l l Nb-95 is the Chinese Weapons Test of October,1980.

No specific corrective action is

(

g3 j4i ; contemplated by N51D-1 because liquid discharges have aircady been minimized.

l 7

8 9 G3 STNuS

% POWER OTHER ST ATUS ISCO RY DISCOVERY DESCRIPTION l~i 15 l lE lQ l 0 l 9 l 9 l@l NA j

l D l@l Contractor Notification l

ACTIVf T V CONTENT RELEASED OF RE LE ASE AVOUNT OF ACTIVITY LOC ATION OF RELE ASE li le I L:_] @ 12 l@l NA

_]

I NA I

7 8 9 10 11 44 45 80 PE RSONN, !xPOSURES NUYBE R TYPE @DESCRIP*ON lil71 l0 10 lo l@l l

NA ll

  • l

',.ERSONNJ'imunSDESCRiPTiON@

uveE R FTl 10 l0 10 l@l NA l

7 8 9 11 12 80 LOSS OF OR DAMAGE TO FACILITY TYFE

DESCRIPTION

L_l@l NA l

i 9 8 9 10 cis 7

ISSUED @ DESCRIPTION [N_j l

NA l

lllllllllllll 2 o

' 8110130472 810930

'8 68 80 DRADOCK05000agngg Kev p htetaunhlin PHONE; 34 3-2110, Ext. 1206 p